Loading...
HomeMy WebLinkAboutA101_Ground Floor PlanA. ALL DIMENSIONS ARE TAKEN TO FACE OF METAL STUD, FACE OF CONCRETE, FACE OF MASONRY, FACE OF EXISTING FINISHES, OR FROM CENTER LINE OF EXISTING COLUMNS UNLESS NOTED AS CLEAR (CLR.) CLEAR DIMENSIONS INDICATE FINISH SURFACE TO FINISH SURFACE SPANS BETWEEN WALLS OR FROM FINISH SURFACE OF WALL TO LATCH/HINGE OF ADJACENT DOOR. B. CONTRACTOR SHALL VERIFY THE EXISTING CONDITIONS AND PROMPTLY NOTIFY THE OWNER AND THE ARCHITECT OF ANY CONDITIONS THAT ARE IN CONFLICT WITH THE PROPOSED WORK OR ARE IN VARIANCE WITH THE CONSTRUCTION DOCUMENTS. C. CONTRACTOR SHALL PROTECT EXISTING MATERIALS, COMPONENTS, AND FEATURES DESIGNATED TO REMAIN, BE SALVAGED, AND/OR REUSED. (SEE DEMOLITION DRAWINGS.) D. CONTRACTOR SHALL COORDINATE WITH THE OWNER AND GOVERNING AUTHORITIES TO ESTABLISH CONSTRUCTION TRAFFIC ACCESS TO THE SITE AND DESIGNATED CONSTRUCTION ACCESS THROUGHOUT THE BUILDING. E. THESE DRAWINGS INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF ARCHITECTURAL DESIGN CONCEPT, THE DIMENSIONS OF THE BUILDING, AND THE MAJOR ARCHITECTURAL ELEMENTS. AS GRAPHIC DOCUMENTS THE DRAWINGS DO NOT INDICATE OR DESCRIBE THE WORK REQUIRED FOR THE FULL PERFORMANCE AND COMPLETION OF THE CONTRACT DOCUMENTS. ON THE BASIS OF THE GENERAL SCOPE INDICATED OR DESCRIBED THE CONTRACTOR SHALL STUDY THE DRAWINGS AND THEIR GENERAL INFERENCE TO FURNISH THE ITEMS REQUIRED FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK. F. ALL DESIGN TEAM DRAWINGS SHALL BE USED TO LOCATE BUILDING ELEMENTS. CONTACT THE ARCHITECT WITH CONFLICTS, DESCREPANCIES, AND OMISSIONS PRIOR TO COMMENCEMENT OF WORK. WRITTEN DOCUMENTATION SHALL BE PROVIDED BY CONTRACTOR REGARDING SUCH ITEMS. G. ALL IN-WALL BLOCKING IS TO BE FIRE TREATED AS REQUIRED BY CODE. H. CONTRACTOR TO ENSURE ALL WALLS TO MEET FIRE SAFETY REQUIREMENTS WHERE NECESSARY. I. ALL EXISTING COLUMNS, INTERIOR AND EXTERIOR WALLS, AND WINDOW WALLS TO BE DRYWALLED, TAPED, PAINTED, AND READY FOR NEW FINISH. GENERAL PLAN NOTES 3 4 5 BA A201 1 TENANT 110 RESTROOM 111 VESTIBULE 104 MECH 105 RESTROOM 103 RESTROOM 102 FEDEX 100 104 10 0 B A6-S A6-S A6-S 110B 3 40 ' - 0 3 / 1 6 " 15 ' - 5 1 / 4 " 6' - 1 1 / 4 " 1' - 1 1 9 / 1 6 " 6' - 0 1 / 1 6 " 4' - 0"1' - 6"4' - 0"8' - 1 7/8"6' - 4"8' - 2 1/8"4' - 0"1' - 6"4' - 0"8' - 6"6' - 4"6' - 7 1/2" 5' - 4 7/8"7' - 10 7/8"7' - 10 7/8"17' - 10 5/8"12' - 1 3/4"7' - 11 3/8" 10 5 10 3 10 2 11 1 10 0 A 10 1 11 0 A B3-S B3-S B3-S B3-SB3-S B3-S B3-S RB1 CPT1 PT1 ENTRY VESTIBULE 101 A101 2 6 1/4"6' - 4"6 1/4" A101 3 1 1 1 1 1 1 2 A3-S 4' M I N . SF1 SF1 SF2 SF1 SF1 SF2 4 4 5 5 3 3 7' - 4"7' - 4" FUTURE WORK B3-S B3-S 2 2 4' - 0"12' - 0"4' - 0"12' - 6 1/8"4' - 0"12' - 0"4' - 0" 41010 11 A A4102 1 RB1 FL2 WC1, PT1 RESTROOM 103 RB1 FL2 WC1, PT1 RESTROOM 102 VESTIBULE 104 TENANT 110 RB1 CPT1 PT1 FEDEX 100 RB1 PT1 MECH 105 110B 10 5 10 0 B 10 3 10 2 A410 5 A410 4Si m 1 Sim 4 3 3 Sim 2Si m 6 6 B3-S B3-S B3-S B3-S B3-S A3-S A6-S A6-S RB1 FL2 WC1, PT1 RESTROOM 111 A410 1 Sim 4Si m 3 Sim 2Si m 6 6 FUTURE WORK A. ALL WALLS ARE PAINT, U.N.O. B. LEVEL & FINISH OF GYP. BD. WALLS AND SOFFITS TO BE LEVEL 4 FINISH, U.N.O. C. ALL GYP. BOARD CEILINGS TO BE PAINTED, U.N.O. D. CARPET SEAMS TO BE LOCATED AT CENTERLINE OF DOOR IN CLOSED POSITION. E. ALIGN FLOORING TRANSITIONS WITH FINISH BASE EXCEPT AT DOORS, U.N.O. F. ALL TRANSITION/REDUCER STRIPS AND OTHER THRESHOLDS TO BE LOCATED AT CENTERLINE OF DOOR WHEN IN CLOSED POSITION G. ALL REQUIRED FLOORING PREPERATIONS SHALL BE BY FLOORING CONTRACTOR. H. PAINT ALL HOLLOW METAL DOOR FRAMES, U.N.O. I. SEAL AROUND ALL DOOR FRAMES AND CASEWORK WITH COLOR TO MATCH WALL. J. ALL PLASTIC LAMINATE ON VERTICAL SURFACES TO RUN VERTICALLY. K. PAINT STANDARDS: a. WALLS: EGG-SHELL b. CEILINGS: FLAT c. DOOR FRAMES/TRIM: SATIN L. ALL FINISH MATERIAL SAMPLES AND PRODUCT DATA ARE TO BE SUBMITTED TO ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION. GENERAL FINISH NOTES TYPICAL FINISHES (U.N.O.) BASE WALL ROOM NAME NUMBER NOTE: FINISHES INDICATED IN FINISH LEGEND BLOCKS ARE GENERAL OVERALL FINISHES FOR ROOM UNLESS OTHERWISE INDICATED BY NOTE, REMARK, DETAIL AND/OR ELEVATION. OFFICE 1234 CPT1 FINISH REMARKS RB1 IPT1 1,2,3 FLOOR ITEM FINISH HOLLOW METAL FRAMES PT1 ELECTRICAL DEVICES COLOR WHITE INTERIOR HOLLOW METAL DOORS PT1 FINISH LEGEND BLOCK SHEET NO SHEET REVISIONS OWNER NFI HARVEST MARKET 2140 E 116TH STREET CARMEL, IN 46032 GENERAL CONTRACTOR ALLEATO GROUP 8383 CRAIG STREET, SUITE 150 INDIANAPOLIS, IN 46250 P: 317.760.0088 W: ALLEATOGROUP.COM PROJECT ADDRESS PROJECT # DOCUMENT TYPE DATE TH E S E D R A W I N G S , S P E C I F I C A T I O N S A N D A L L C O P I E S T H E R E O F A R E A N D S H A L L R E M A I N T H E P R O P E R T Y O F D K G R , L L C . T H E Y S H A L L B E U S E D O N L Y W I T H R E S P E C T T O T H I S P R O J E C T A N D A R E N O T T O B E U S E D O N A N Y O T H E R P R O J E C T O R W O R K W I T H O U T P R I O R W R I T T E N P E R M I S S I O N F R O M D K G R , L L C. DR A W N B Y : CH E C K E D B Y : STRUCTURAL ENGINEER JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW INDIANAPOLIS, IN 46240 P: 317.617.4270 W: JPSCONSULTINGENGINEERS.COM MECHANICAL, ELECTRICAL AND PLUMBING ENGINEERS THE ENGINEERING COLLABORATIVE 2410 EXECUTIVE DRIVE, SUITE 100 INDIANAPOLIS, IN 46241 P: 317.636.3941 W: TEC-MEP.COM A101 GROUND FLOOR PLAN 2140 E 116TH STREET CARMEL, IN 46032 2025-012 PERMIT SET 01 APR 2025 Au t h o r Ch e c k e r NIEMANN FOODS - FEDEX SHELL PLAN NOTES 1CORNER GUARD CG1 2 DEMOLISH EXISTING DOOR AND INFILL WALL 3 4" CONCRETE STOOP, 4000 PSI W/BROOM FINISH, WITH FIBER MESH REINFORCING ON 4" COMPACTED CRUSHED STONE ON COMPACTED SUB-BASE 4 EXISTING CONCRETE FLOOR, PREPARE TO RECEIVE NEW TENANT FINISHES 5 NEW 5/8" GYPSUM BOARD FINISH AT EXISTING METAL STUD FRAMING, TYP. 6 WALL PROTECTION, WC1, TO 5' A.F.F., EXTEND MINIMUM 24" FROM EDGE OF UTILITY SINK. 7 ROOF TOP UNIT. REFER TO MECHANICAL DRAWINGS FOR TYPE AND EXACT SIZING. 8 EXISTING ROOF SYSTEM TO REMAIN 9 ROOF PENETRATION, EXTEND NEW FLASHING UP VENTSTACK 10 RELOCATE EXISTING U-BIKE RACKS, PATCH AND REPAIR LOCATIONS OF EXISTING SURFACE MOUNTING. 11 RELOCATE EXISTING FLAG POLE, NEW FOUNDATION, SIMILAR TO EXISTING. 3/16" = 1'-0" GROUND FLOOR PLAN1 1/2" = 1'-0" ENLARGED RESTROOM PLAN2 INTERIOR FINISH SELECTION SUMMARY NAME MANUFACTURER STYLE MODEL NUMBER COLOR MATERIAL COMMENTS CARPET CPT1 MANNINGTON RUFFIAN NA GRANITE ENTRY CARPET Carpet Tile - Monolithic Installation. CPT2 MANNINGTON FEX4T M38068-002A InfinityModular LW08 CARPET Carpet Tile, 24" sq. (Design 4.0) - Vertical Ashlar Orientation. CORNER GUARDS CG1 C/S GROUP TEXTURED LG-150 CLEAR VINYL 1-1/2" Low Profile, Mount Top @ 48" AFF Typ. WG1 WALLGUARD FLAT WALLGUARD 2120 IVORY VINYL 1-1/2" Low Profile, Mount Top @ 48" AFF Typ. HARD FLOORING FL1 ARMSTRONG STD. EXCELON IMPERIAL TEXTURE 51915 CHARCOAL VCT 12" x 12" - 1/8" (Back Rooms) FL2 MANNINGTON BIOSPEC FB INLAID SHEET -- STONE GRAY 10328 SHEET VINYL Sheet Vinyl (Back Rooms). TS1 MANNINGTON -- 152 BLACK TRANSITION STRIP Transition From Carpet To Resilient TS2 MANNINGTON -- 800 BLACK TRANSITION STRIP Transition From Carpet To Concrete PAINT PT1 SHERMAN WILLIAMS S24 SERIES - SCUFF TUFF SW7005 PURE WHITE Walls/ Hard Surface Clg. Eg-Shel Water-Based Enamel. PT2 SHERMAN WILLIAMS S24 SERIES - SCUFF TUFF SW7005 PURE WHITE Doors & Trim. Semi-Gloss Water Based Enamel. RESILIENT BASE RB1 MANNINGTON THERMOPLASTIC VINYL EDGE NIGHT BLACK 4" 4"H With Cove/ Toe, 1/8" Thk. WALL WC1 MARLITE TEXTURED P-100 WHITE Wainscot w/ Plastic Trim To Match FRP 1/2" = 1'-0" ENLARGED RESTROOM PLAN3 # DESCRIPTION DATE 2 BULLETIN 01 04/25/2025 4 CITY COMMENTS 05/22/2025