HomeMy WebLinkAboutA111_Reflected Ceiling PlanA. RUN ALL EXISTING AND NEW MC AND DATA CABLING IN HARD CONDUIT. B. SEE INTERIOR ELEVATIONS FOR MOUNTING HEIGHTS OF ALL WALL MOUNTED FIXTURES. C. PROVIDE OWNER WITH HVAC LAYOUT OF DIFFUSERS, BOXES, AND STATE LOCATIONS PRIOR TO INSTALLATION AS WELL AS A BALANACE REPORT AT CLOSE OF JOB. D. ALL GYPSUM BOARD CEILINGS TO HAVE VERTICAL FACES EXTENDED UP TO DECK ABOVE UNLESS NOTED OTHERWISE. E. ALL SUSPENDED OR WALL MOUNTED LIGHTING TO HAVE HEIGHTS REVIEWED WITH DESIGNER PRIOR TO INSTALLING ELECTRICAL CONNECTION POINT(S). F. EMERGENCY LIGHTING IS BY DESIGN BUILD CONTRACTOR AND SHOULD ADHERE TO ALL LIFE SAFETY CODES (NFPA 101 & IBC). PROVIDE EDGE-LIT ARCHITECTURAL EXIT SIGNS AND WALL MOUNT EGRESS EMERGENCY LIGHTS AS REQUIRED TO FULFILL EMERGENCY EGRESS REQUIREMENTS. G. ALL EXTERIOR EXITS ARE TO HAVE WET-LISTED COLD WEATHER (RATED) EMERGENCY EGRESS LIGHTING THAT COVERS AT MINIMUM 1 FOOTCANDLE AVERAGE 10' FROM ALL EGRESS DOOR THRESHOLDS, OR THAT WHICH IS GREATER WITHIN NFPA 101 AND/OR IBC LIFE SAFETY CODES. H. ELECTRICAL CONTRACTOR AND/OR DESIGN BUILD CONTRACTOR IS TO VERIFY THAT PROJECT CRITERIA MEETS INDIANA ASHRAEH 90.1 ENERGY CODES. DESIGN INTENT IS TO BE WITHIN WATTS PER SQUARE FOOT. PROVIDE ENERGEY MANAGEMENT CONTROLS, SUCH AS SENSOR CONTROLS (ULTRASONIC AND MOTION DETECTION) AND/OR RELAY TIME CLOCKS, AS REQUIRED BY CODE. I. DRAWINGS, SPECIFICATIONS, AND ENERGY CONTROL DEVICES ARE SHOWN WITH THE INTENT OF MEETING CURRENT STATE ENERGY CODES. SUBMITTINGPARTY IS TO ALERT DESIGNER AND OWNER OF ANY ADDITIONAL DEVICES OR LOAD CHANGES NECESSARY IN ORDER TO ADHERE TO THE CODE, PRIOR TO SUBMISSION OF COMCHECK. J. ALL LED FIXTURES WITHIN CONFERENC ROOMS ARE TO BE ON A DIMMER. ELECTRICAL CONTRACTOR RESPONSIBLE FOR VERIFYING LED DRIVER AND DIMMER(S) ARE COMPATIBLE TECHNOLOGY. GENERAL CEILING NOTES ELEVATION IDENTIFICATION 2'x2' OR 4'x4' SUSPENDED ACOUSTICAL CEILING EXPOSED EXISTING STRUCTURE 1i 1'-0" C1 TYPE:24" x 48" x 5/8" ACOUSTICAL PANEL CEILING WITH TEGULAR EDGE GRID:WHITE 15/16" GRID AND SUSPENSION SYSTEM MFG:ARMSTRONG (OR APPROVED EQUAL) MODEL:DUNE (OR APPROVED EQUAL) NOTE:LONG LEG CEILING ANGLE AT PERIMETER BULKHEAD, ALUMINUM FINISH, AS NEEDED C2 GYPSUM BOARD -PAINT FLAT CEILING WHITE UNLESS NOTED OTHERWISE L1 TYPE: TBD MFG: TBD MODEL: TBD *NOTE: ALL LIGHTS TO BE ICC RATED CEILING PLAN LEGEND CEILING TYPES LIGHT FIXTURE SCHEDULE 3 4 5 BA C1 9' - 0" C1 8' - 0" C1 8' - 0" C1 8' - 0" C1 10' - 0" C1 10' - 0" C1 10' - 0" C2 10' - 0" FEDEX 100 TENANT 110 RESTROOM 102 RESTROOM 103 MECH 105 VESTIBULE 104 RESTROOM 111 ENTRY VESTIBULE 101 FUTURE WORK 4 SHEET NO SHEET REVISIONS OWNER NFI HARVEST MARKET 2140 E 116TH STREET CARMEL, IN 46032 GENERAL CONTRACTOR ALLEATO GROUP 8383 CRAIG STREET, SUITE 150 INDIANAPOLIS, IN 46250 P: 317.760.0088 W: ALLEATOGROUP.COM PROJECT ADDRESS PROJECT # DOCUMENT TYPE DATE TH E S E D R A W I N G S , S P E C I F I C A T I O N S A N D A L L C O P I E S T H E R E O F A R E A N D S H A L L R E M A I N T H E P R O P E R T Y O F D K G R , L L C . T H E Y S H A L L B E U S E D O N L Y W I T H R E S P E C T T O T H I S P R O J E C T A N D A R E N O T T O B E U S E D O N A N Y O T H E R P R O J E C T O R W O R K W I T H O U T P R I O R W R I T T E N P E R M I S S I O N F R O M D K G R , L L C. DR A W N B Y : CH E C K E D B Y : STRUCTURAL ENGINEER JPS CONSULTING ENGINEERS 9365 COUNSELORS ROW INDIANAPOLIS, IN 46240 P: 317.617.4270 W: JPSCONSULTINGENGINEERS.COM MECHANICAL, ELECTRICAL AND PLUMBING ENGINEERS THE ENGINEERING COLLABORATIVE 2410 EXECUTIVE DRIVE, SUITE 100 INDIANAPOLIS, IN 46241 P: 317.636.3941 W: TEC-MEP.COM A111 REFLECTED CEILING PLAN 2140 E 116TH STREET CARMEL, IN 46032 2025-012 PERMIT SET 01 APR 2025 Au t h o r Ch e c k e r NIEMANN FOODS - FEDEX SHELL CEILING PLAN NOTES 3/16" = 1'-0" REFLECTED CEILING PLAN1 # DESCRIPTION DATE 4 CITY COMMENTS 05/22/2025