Loading...
HomeMy WebLinkAboutA212.1 - EXISTING BUILDING ELEVATIONS - BLDG 121ST FLOOR EL: 0' -0" 2ND FLOOR EL: 8' -0" TRUSS BEARING EL: 17' -5" 1 33 2 2 2 2 8 8 1ST FLOOR EL: 0' -0" 2ND FLOOR EL: 8' -0" TRUSS BEARING EL: 17' -5" 1 2 2 2 2 2 2 1 4 5 7 7 7 7 7 7 33333 1 2 2 4 5 7 7 3 3 2 2 6 6 6 6 6 6 6 6 8 1ST FLOOR EL: 0' -0" 2ND FLOOR EL: 8' -0" TRUSS BEARING EL: 17' -5" 1 2 2 22 2 2 1 5 7 7 7 7 7 7 33333 1 2 2 5 7 7 3 3 2 2 6 6 6 6 6 6 6 6 8 1ST FLOOR EL: 0' -0" 2ND FLOOR EL: 8' -0" TRUSS BEARING EL: 17' -5" 1 33 2 2 2 2 8 8 GENERAL DEMOLITION NOTES 1. CONTRACTOR SHALL FIELD-VERIFY ALL EXISTING CONDITIONS, DIMENSIONS, AND ARRANGEMENTS. 2. CONTRACTOR IS RESPONSIBLE FOR PROTECTION OF ALL EXISTING SURFACES, MATERIALS, AND COMPONENTS TO REMAIN OR BE RELOCATED. DAMAGE TO THESE RESULTING FROM PERFORMANCE OF WORK SHALL BE REPAIRED BY CONTRACTOR TO SATISFACTION OF OWNER AND ARCHITECT AT NO ADDITIONAL EXPENSE TO OWNER. 3. CONTRACTOR SHALL PROVIDE TEMPORARY DUST PROTECTION AS REQUIRED TO PREVENT CONSTRUCTION DEBRIS AND DUST FROM MIGRATING OUT OF PROJECT AREA. OWNER/ARCHITECT SHALL CONFIRM ALL DUST PREVENTION MEASURES/LOCATIONS AND SHALL DETERMINE CHANGES TO THESE MEASURES. 4. ALL EXISTING EQUIPMENT AND FIXTURES SHALL REMAIN PROPERTY OF OWNER. ALL REUSABLE ITEMS SALVAGED DURING DEMOLITION OPERATIONS SHALL BE RETAINED FOR OWNER'S INSPECTION. ONLY ITEMS SO INSPECTED AND REJECTED BY OWNER SHALL BE DISPOSED. ALL OTHER SUCH ITEMS SHALL BE TURNED OVER TO OWNER FOR DISPOSITION. 5. ALL EXISTING SURFACES LOCATED ADJACENT TO, OR EXPOSED BY DEMOLITION WORK AND SCHEDULED TO RECEIVE NEW CONSTRUCTION SHALL BE PATCHED AND REPAIRED AS REQUIRED TO CLEANLY RECEIVE NEW WORK. 6. ALL EXISTING SURFACES LOCATED ADJACENT TO, OR EXPOSED BY DEMOLITION WORK AND SCHEDULED TO REMAIN EXPOSED AFTER COMPLETION OF NEW CONST. SHALL BE REPAIRED AND PATCHED AS REQUIRED TO RECEIVE NEW FINISHES. 7. OWNER WILL BE RESPONSIBLE FOR REMOVAL/REARRANGEMENT OF ALL EXISTING LOOSE FURNISHINGS DURING CONSTRUCTION, UNLESS NOTED OTHERWISE. 8. REFER TO MECH./ELEC. DRAWINGS FOR ADDITIONAL PATCHING AND PREPARATION WORK RELATED TO M.E.P. DEMOLITION ITEMS. 9. EXISTING SLEEVES, HOLES, AND OTHER PENETRATIONS TO BE SEALED PRIOR TO NEW CONSTRUCTION. NEW DAMAGE OF EXISTING BUILDING STRUCTURE ABOVE GRADE EXPOSED BY DEMOLITION AND REMOVAL OF PIPING, APPURTENANCES, EQUIPMENT SHALL BE PATCHED AND REPAIRED AS PART OF THE WORK. MAINTAIN FIRE RATINGS OF ALL AND ADJACENT CONSTRUCTION AFFECTED. 10. CAP ALL PIPING TO REMAIN OR ABANDONED IN ACCORDANCE WITH REQUIREMENTS OF AUTHORITY HAVING JURISDICTION AND IN ACCORDANCE WITH ALL LOCAL AND STATE PLUMBING AND HEALTH CODES. UTILIZE ONLY PRE-MANUFACTURED AND APPROVED FITTINGS TO CAP EXISTING PIPING. 11. COORDINATE ALL DEMOLITION WITH PROJECT SEQUENCING AS DIRECTED BY GENERAL CONTRACTOR OR CONSTRUCTION MANAGER. 12. CONTRACTOR TO COORDINATE WITH CONSTRUCTION MANAGER TO PROVIDE ANY REQUIRED TEMPORARY PATHS OF EGRESS AS REQUIRED PER CODE. MATERIAL COLOR SCHEME LAP SIDING TRIM, FACIA, GUTTER AND DOWNSPOUTS FACEBRICK NOTE: ALL EXPOSED VENTS, CAPS, AND ELECTRICAL EQUIPMENT HOUSING TO BE PREPPED AND PAINTED TO MATCH ADJACENT FEILD COLOR. ELEVATION DEMO NOTES 1 2 3 REMOVE EFFLORESCENCE AND STAINING OF FACEBRICK AROUND THE ENTIRE BUILDING. CONTRACTOR TO PREP EXISTING FACE BRICK AS REQUIRED TO RECEIVE NEW STAIN COLOR. CLEAN AND PREP ALL EXTERIOR WINDOWS TO RECEIVE NEW SEALANT AS REQUIRED. REMOVE LOWER ELBOW AT ALL DOWNSPOUTS AROUND THE BUILDING. PREP ALL GUTTERS, DRIP EDGES, DOWNSPOUTS, AND ELBOWS TO BE PAINTED. REMOVE AND REPLACE SPLASH BLOCKS AT ALL DOWNSPOUTS. REMOVE ALL EXTERIOR RAILINGS AT BUILDING ENTRIES, TYPCIAL. PREP AREA TO RECIEVE NEW BUILDINGS.SEE CIVIL DRAWINGS FOR MORE INFORMATION. REMOVE ALL DOOR, FRAME ACCESSORIES, AND THRESHOLD OF EXTERIOR BUILDING ENTRIES. REMOVE ANY AND ALL ROTTEN OR STRUCTURALLY COMPROMISED FRAMING @ OPENINGS. PREP OPENING FOR TO RECEIVE NEW DOOR, FRAME, AND THRESHOLD. REFER TO STRUCTURAL DRAWINGS FOR STRUCTURAL REQUIREMENTS INCLUDING SHORING. REMOVE ALL EXTERIOR LIGHT FIXTURES AROUND THE BUILDING. PREP AREAS TO RECEIVE NEW LIGHT FIXTURE. SEE ELECTRICAL DRAWINGS FOR MORE INFORMATION. REMOVE ALL PATIO / BALCONY DOOR, FRAME, THRESHOLD AND ACCESSORIES AS REQUIRED. REMOVE ADJACENT WOOD FRAMING AND PREP OPENING TO REVEIVE NEW DOOR AND FRAMING AS REQUIRED. REFER TO STRUCTURAL DRAWINGS FOR STRUCTURAL REQUIREMENTS, INCLUDING SHORING. OWNER TO CONFIRM EXTENTS OF LOCATIONS. PRESERVE AND PROTECT, EXISTING ROOF TO REMAIN AS IS. 4 5 6 7 8 PR O J E C T DR A W I N G T I T L E SE A L SH E E T PR O J E C T I N F O RE V I S I O N S ARCHITECT GC/CM CLIENT 22028 MAY 2, 2025 50% CD SET A212.1 EX I S T I N G B U I L D I N G EL E V A T I O N S - B L D G 1 2 BU C K I N G H A M A T GR A M E R C Y - A R E A B SCALE: 1/8" = 1'-0"4 SIDE ELEVATION SCALE: 1/8" = 1'-0"1 FRONT ELEVATION SCALE: 1/8" = 1'-0"2 BACK ELEVATION SCALE: 1/8" = 1'-0"3 SIDE ELEVATION #DESCRIPTION DATE