Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
CB27394-SITE-2
X-S4 MH: 20 X-S4 MH: 20 X-WM3 MH: 15 X-WM4 MH: 15 0.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.10.20.30.30.20.20.20.20.20.10.10.10.00.00.00.00.00.10.10.10.10.1 0.1 0.30.40.40.2 0.1 0.1 0.2 0.1 0.2 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.0 0.00.00.00.00.00.10.2 0.7 1.0 0.9 0.7 0.6 1.6 2.4 2.1 1.4 0.8 3.2 4.6 3.6 2.3 1.1 5.7 5.5 4.6 3.2 1.6 5.8 6.2 5.8 5.4 5.5 4.4 2.8 4.1 3.4 1.5 2.1 0.1 0.5 0.9 0.4 0.4 0.4 0.5 0.7 0.8 0.8 1.0 1.6 1.6 1.3 1.3 1.6 2.3 3.9 3.4 2.1 1.6 2.4 3.6 4.8 4.1 5.9 4.7 3.0 2.1 3.2 4.5 5.5 6.5 5.9 4.8 3.0 2.2 3.3 5.3 6.5 6.9 4.1 3.5 2.1 1.8 3.0 4.1 5.4 5.8 1.7 1.7 1.4 1.5 2.2 3.2 4.0 3.2 1.2 1.2 1.4 1.9 2.1 1.6 1.1 1.4 2.4 3.1 2.7 2.9 1.8 1.6 1.4 1.0 0.8 0.8 0.9 0.1 1.7 1.4 1.3 1.8 1.4 1.3 1.1 0.8 0.5 0.4 0.3 0.1 FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM W W W W W W W W W W W E(A)E(A)E(A)E(A)E(A)E(A)E(A)E(A)E(A)E(A)E(A)E(A) G G G E E E E E E E W E E E E E E 83'-5" Luminaire Schedule Symbol Qty Label Arrangement Lum. Lumens LLF Lum. Watts Description 1 X-WM3 Wall Mount 7547 0.900 54 VALS-09L-3W-50K7 1 X-WM4 Wall Mount 8098 0.900 54 VALS-09L-4M-50K7 2 X-S4 Single 16159 0.900 111 VALS-18L-4M-50K7 Calculation Summary Label CalcType Units Avg Max Min Avg/Min Max/Min _Property Line Illuminance Fc 0.03 0.4 0.0 N.A.N.A. Paved Area - Left Side Illuminance Fc 2.83 6.2 0.1 28.30 62.00 Paved Area - Right Side Illuminance Fc 2.40 6.9 0.1 24.00 69.00 All electrical work shall comply with National, State, and Local codes including and not limited to the National Electric Code, NFPA 101 Life Safety Code, ASHREA and /or IECC Energy Codes. The information contained in this document is proprietary to CBMC Lighting Solutions. This document is prepared for a specific site and incorporates calculations based on data available from the client at this time. By accepting and using this document, the recipient agrees to protect its contents from further dissemination, (other than that within the organization necessary to evaluate such specification) without the written permission of CBMC Lighting Solutions. the contents of this document are not to be reproduced or copied in whole or in part without the written permission of CBMC Lighting Solutions. copyright © 2018 CBMC Lighting Solutions all rights reserved.CB27394-SITE-2 5855 KOPETSKY DR. SUITE G. | INDIANAPOLIS, IN 46217 317-780-8350| WWW.CBMCINC.COM SITE LAYOUTSEE MORE This lighting pattern represents illumination levels calculated from laboratory data taken under controlled conditions in accordance with IESNA approved methods. Actual performance of any manufacturer's luminaire may vary due to variation in electrical voltage, tolerance in lamps and LED lumen package, location adjustments, and other variable field conditions. Contractor to check and verify all dimensions on site before commencing any work shown. Jacquie's Catering - Carmel Project No: Scale: Date: Drawn By: LP1Drawing No: SJM - 1" = 30' 3/13/25 LIGHTING NOTES: - Mounting Height = 20' - Poles 15' - Building Mounted - Light Loss Factor = 0.90 - Footcandle Values Calculated @ Grade - Reflectance Values - 80/50/20 (office spaces) 50/30/20 (warehouse areas) National Lighting Vendor: For pricing and technical assistance contact: Russ Miller of CBMC INC, tel# 317-697-7510, rmiller@cbmcinc.com