Loading...
HomeMy WebLinkAboutC100-Existing Conditions & Demo PlansD Y H U. P . U. P . U. P . RW RW U. P . U. P . 75 ' R a d . 68.90' 1 2 R/W 68.90' 1 2 R/W 15' Electrical & Telecomm. Easement Instr. No. 2019025955 & Instr. No. 2019031338 Approx. Limit of W.R. Fertig Open Regulated Drain (75' from Top of Bank) Approx. Top of Bank W.R. Fertig Open Regulated Drain Var. Width Drainage Access & Maintenance Easement Instr. No. 200300127290 20' Sewer Easement Instr. No. 8702420 15' Electrical & Telecomm. Easement Instr. No. 2019025955 & Instr. No. 2019031338 South R/W 116th Street per INDOT Proj. No. STP-B886 (007) DONNYBROOK ADDITION Plat Book 2, Pages 233-234 Roland W. Slagle, III et al Inst. No. 2020079971 Lot 3Lot 2Lot 1 MONON FARMS CONDOMINIUMS Plat Cabinet 3, Slide 651 Inst. No. 200500039345 Monon Farms Lane E. 1 1 6 t h S t r e e t TBM #1 TBM #2 EXISTING STONE DRIVE TO BE REMOVED CLEAR AND GRUB VEGETATION CLEAR AND GRUB VEGETATION ONLY AS REQUIRED FOR GRADING / CONSTRUCTION TREE TO BE REMOVED CLEAR AND GRUB VEGETATION ONLY AS REQUIRED FOR STORM / SANITARY SEWER CONSTRUCTION CLEAR AND GRUB VEGETATION ONLY AS REQUIRED FOR SANITARY SEWER CONSTRUCTION EXISTING CONCRETE DRIVE APPROACH TO BE REMOVED APPROXIMATE LIMITS OF ASPHALT / CONCRETE SIDEWALK & CONC. CURB & GUTTER TO BE REMOVED. SEE SHEET C600 FOR LIMITS OF NEW WORK. INDICATED TREES TO BE PROTECTED FOR THE DURATION OF CONSTRUCTION. CONTRACTOR TO COORDINATE WITH OWNER / ENGINEER TO VERIFY LOCATION OF ALL TREES TO BE PROTECTED PRIOR TO START OF CONSTRUCTION ACTIVITIES. INDICATED TREES TO BE PROTECTED FOR THE DURATION OF CONSTRUCTION. CONTRACTOR TO COORDINATE WITH OWNER / ENGINEER TO VERIFY LOCATION OF ALL TREES TO BE PROTECTED PRIOR TO START OF CONSTRUCTION ACTIVITIES. DA T E MA R K RE V I S I O N S BY S & A JOB NO. SHEET NO. DRAWN BY:CHECKED BY: TH I S D R A W I N G I S N O T I N T E N D E D T O B E RE P R E S E N T E D A S A R E T R A C E M E N T O R OR I G I N A L B O U N D A R Y S U R V E Y , A R O U T E S U R V E Y O R A S U R V E Y O R LO C A T I O N R E P O R T . CE R T I F I E D : S T O E P P E L W E R T H A L W A Y S O N 79 6 5 E a s t 1 0 6 t h S t r e e t , F i s h e r s , I N 4 6 0 3 8 - 2 5 0 5 ph o n e : 3 1 7 . 8 4 9 . 5 9 3 5 f a x : 3 1 7 . 8 4 9 . 5 9 4 2 EX I S T I N G C O N D I T I O N S / D E M O P L A N S C100 111895GBC PDR BKR CL A Y T O W N S H I P HA M I L T O N C O U N T Y , I N D I A N A Fi l e N a m e : S: \ 1 1 1 8 9 5 G B C \ D W G \ C 1 0 0 - E x i s t i n g C o n d i t i o n s & D e m o P l a n s . d w g - C1 0 0 Mo d i f i e d / B y : Ju n e 2 6 , 2 0 2 5 1 1 : 1 1 : 5 9 A M / pr i c h a r d s Pl o t t e d / B y : Ju n e 2 6 , 2 0 2 5 1 1 : 2 2 : 2 4 A M / Pa u l R i c h a r d s 06 / 2 6 / 2 5 SW I N L E Y F O R E S T 12 2 5 E A S T 1 1 6 t h S T R E E T MA T C H L I N E " A " - S E E S H E E T C 1 0 1 MA T C H L I N E " A " - S E E S H E E T C 1 0 1 GRAPHIC SCALE 0' ( IN FEET ) 30'15'30' 1" = 30' BENCHMARK DATA ORIGINATING BENCHMARK: BENCHMARK ELEVATIONS FOR THIS PROJECT WERE DERIVED USING THE NATIONAL GEODETIC SURVEY ONLINE POSITIONING USER SERVICE (O.P.U.S) AND ARE REFERENCED TO THE NAVD '88 DATUM. SITE TBMs: TBM #1: A CUT SQUARE ON TOP OF THE CONCRETE CURB ON THE SOUTH SIDE OF 116th STREET, IMMEDIATELY EAST OF THE ENTRANCE TO THE GRAVEL DRIVE ON THE WEST SIDE OF THE SITE. EL: 832.38 (NAVD 88) TBM #2: A CUT "X" ON TOP OF THE CONCRETE TOP OF THE BRICK HEADWALL OVER CARMEL CREEK, AT THE NORTHWEST CORNER OF THE WALL. EL: 830.09 (NAVD 88) NOTES 1.THIS SURVEY REFLECTS ABOVE GROUND INDICATIONS OF UTILITIES AND INFORMATION AVAILABLE FROM UTILITY COMPANIES. THE SURVEYOR MAKES NO GUARANTEE THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. THE SURVEYOR FURTHER DOES NOT WARRANT THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED, ALTHOUGH HE DOES CERTIFY THAT THEY ARE LOCATED AS ACCURATELY AS POSSIBLE FROM THE INFORMATION AVAILABLE. THE SURVEYOR HAS NOT PHYSICALLY LOCATED THE UNDERGROUND UTILITIES. 2.CONTRACTOR SHALL VERIFY DEPTHS OF ALL EXISTING ONSITE UTILITIES PRIOR TO CONSTRUCTION TO CONFIRM THERE ARE NOT ANY CONFLICTS WITH OTHER UTILITIES, STORM SEWERS OR STREETS. CONFLICTS AFTER CONSTRUCTION BEGINS ARE SOLELY THE CONTRACTOR'S RESPONSIBILITY. 3.STORM WATER CONTROLS SHOWN ON THE INITIAL SWPPP (C300) SHOULD BE INSTALLED AS SOON AS PRACTICAL. 4.IF IT WILL BE NECESSARY TO RELOCATE EXISTING UTILITIES, THE EXPENSE OF SUCH RELOCATION SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. ALL UTILITY POLES SHALL BE LOCATED WITHIN ONE FOOT OF THE PROPOSED RIGHT-OF-WAY. LEGEND EXISTING FEATURES ELECTRIC LINE, UNDERGROUND FIBER OPTIC LINE GAS MAIN ELECTRIC LINE, OVERHEAD TELEPHONE LINE WATER MAIN SEWER, SANITARY SEWER, STORM CONTOUR FENCE LINE WATER FLOWLINE NORMAL WATER ELEVATION FLOODWAY FRINGE (PRE-PUBLISHED FLOOD LINE) TREE LINE MAILBOX UTILITY POLE GUY ANCHOR TELECOM, FIBER OPTIC HANDHOLE ELECTRICAL, ACCESS COVER WATER, HYDRANT WATER, VALVE RISER GATE POST SIGN RIGHT-OF-WAY MARKER TREE PROPOSED FEATURES DENOTES CONSTRUCTION LIMITS DENOTES TREE PROTECTION FENCE LOCATION(S)