HomeMy WebLinkAboutC100-Existing Conditions & Demo PlansD
Y
H
U.
P
.
U.
P
.
U.
P
.
RW
RW
U.
P
.
U.
P
.
75
'
R
a
d
.
68.90' 1 2 R/W
68.90' 1 2 R/W
15' Electrical & Telecomm. Easement
Instr. No. 2019025955 &
Instr. No. 2019031338
Approx. Limit of
W.R. Fertig Open
Regulated Drain
(75' from Top of Bank)
Approx. Top of Bank
W.R. Fertig Open
Regulated Drain
Var. Width Drainage Access
& Maintenance Easement
Instr. No. 200300127290
20' Sewer Easement
Instr. No. 8702420
15' Electrical &
Telecomm. Easement
Instr. No. 2019025955 &
Instr. No. 2019031338
South R/W 116th Street
per INDOT Proj. No.
STP-B886 (007)
DONNYBROOK ADDITION
Plat Book 2, Pages 233-234
Roland W. Slagle, III et al
Inst. No. 2020079971
Lot 3Lot 2Lot 1
MONON FARMS CONDOMINIUMS
Plat Cabinet 3, Slide 651
Inst. No. 200500039345
Monon Farms Lane
E.
1
1
6
t
h
S
t
r
e
e
t
TBM #1
TBM #2
EXISTING STONE DRIVE
TO BE REMOVED
CLEAR AND GRUB
VEGETATION
CLEAR AND GRUB
VEGETATION ONLY AS
REQUIRED FOR GRADING /
CONSTRUCTION
TREE TO BE REMOVED
CLEAR AND GRUB
VEGETATION ONLY AS
REQUIRED FOR STORM /
SANITARY SEWER
CONSTRUCTION
CLEAR AND GRUB
VEGETATION ONLY AS
REQUIRED FOR SANITARY
SEWER CONSTRUCTION
EXISTING CONCRETE DRIVE
APPROACH TO BE REMOVED
APPROXIMATE LIMITS OF
ASPHALT / CONCRETE SIDEWALK
& CONC. CURB & GUTTER TO BE
REMOVED. SEE SHEET C600 FOR
LIMITS OF NEW WORK.
INDICATED TREES TO BE PROTECTED FOR THE
DURATION OF CONSTRUCTION. CONTRACTOR
TO COORDINATE WITH OWNER / ENGINEER TO
VERIFY LOCATION OF ALL TREES TO BE PROTECTED
PRIOR TO START OF CONSTRUCTION ACTIVITIES.
INDICATED TREES TO BE PROTECTED FOR THE
DURATION OF CONSTRUCTION. CONTRACTOR
TO COORDINATE WITH OWNER / ENGINEER TO
VERIFY LOCATION OF ALL TREES TO BE PROTECTED
PRIOR TO START OF CONSTRUCTION ACTIVITIES.
DA
T
E
MA
R
K
RE
V
I
S
I
O
N
S
BY
S & A JOB NO.
SHEET NO.
DRAWN BY:CHECKED BY:
TH
I
S
D
R
A
W
I
N
G
I
S
N
O
T
I
N
T
E
N
D
E
D
T
O
B
E
RE
P
R
E
S
E
N
T
E
D
A
S
A
R
E
T
R
A
C
E
M
E
N
T
O
R
OR
I
G
I
N
A
L
B
O
U
N
D
A
R
Y
S
U
R
V
E
Y
,
A
R
O
U
T
E
S
U
R
V
E
Y
O
R
A
S
U
R
V
E
Y
O
R
LO
C
A
T
I
O
N
R
E
P
O
R
T
.
CE
R
T
I
F
I
E
D
:
S
T
O
E
P
P
E
L
W
E
R
T
H
A
L
W
A
Y
S
O
N
79
6
5
E
a
s
t
1
0
6
t
h
S
t
r
e
e
t
,
F
i
s
h
e
r
s
,
I
N
4
6
0
3
8
-
2
5
0
5
ph
o
n
e
:
3
1
7
.
8
4
9
.
5
9
3
5
f
a
x
:
3
1
7
.
8
4
9
.
5
9
4
2
EX
I
S
T
I
N
G
C
O
N
D
I
T
I
O
N
S
/
D
E
M
O
P
L
A
N
S
C100
111895GBC
PDR BKR
CL
A
Y
T
O
W
N
S
H
I
P
HA
M
I
L
T
O
N
C
O
U
N
T
Y
,
I
N
D
I
A
N
A
Fi
l
e
N
a
m
e
:
S:
\
1
1
1
8
9
5
G
B
C
\
D
W
G
\
C
1
0
0
-
E
x
i
s
t
i
n
g
C
o
n
d
i
t
i
o
n
s
&
D
e
m
o
P
l
a
n
s
.
d
w
g
-
C1
0
0
Mo
d
i
f
i
e
d
/
B
y
:
Ju
n
e
2
6
,
2
0
2
5
1
1
:
1
1
:
5
9
A
M
/
pr
i
c
h
a
r
d
s
Pl
o
t
t
e
d
/
B
y
:
Ju
n
e
2
6
,
2
0
2
5
1
1
:
2
2
:
2
4
A
M
/
Pa
u
l
R
i
c
h
a
r
d
s
06
/
2
6
/
2
5
SW
I
N
L
E
Y
F
O
R
E
S
T
12
2
5
E
A
S
T
1
1
6
t
h
S
T
R
E
E
T
MA
T
C
H
L
I
N
E
"
A
"
-
S
E
E
S
H
E
E
T
C
1
0
1
MA
T
C
H
L
I
N
E
"
A
"
-
S
E
E
S
H
E
E
T
C
1
0
1
GRAPHIC SCALE
0'
( IN FEET )
30'15'30'
1" = 30'
BENCHMARK DATA
ORIGINATING BENCHMARK:
BENCHMARK ELEVATIONS FOR THIS PROJECT WERE DERIVED USING THE
NATIONAL GEODETIC SURVEY ONLINE POSITIONING USER SERVICE
(O.P.U.S) AND ARE REFERENCED TO THE NAVD '88 DATUM.
SITE TBMs:
TBM #1: A CUT SQUARE ON TOP OF THE CONCRETE CURB ON THE SOUTH
SIDE OF 116th STREET, IMMEDIATELY EAST OF THE ENTRANCE TO THE
GRAVEL DRIVE ON THE WEST SIDE OF THE SITE.
EL: 832.38 (NAVD 88)
TBM #2: A CUT "X" ON TOP OF THE CONCRETE TOP OF THE BRICK
HEADWALL OVER CARMEL CREEK, AT THE NORTHWEST CORNER OF THE
WALL.
EL: 830.09 (NAVD 88)
NOTES
1.THIS SURVEY REFLECTS ABOVE GROUND INDICATIONS OF UTILITIES
AND INFORMATION AVAILABLE FROM UTILITY COMPANIES. THE
SURVEYOR MAKES NO GUARANTEE THAT THE UNDERGROUND
UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA,
EITHER IN SERVICE OR ABANDONED. THE SURVEYOR FURTHER DOES
NOT WARRANT THAT THE UNDERGROUND UTILITIES SHOWN ARE IN
THE EXACT LOCATION INDICATED, ALTHOUGH HE DOES CERTIFY
THAT THEY ARE LOCATED AS ACCURATELY AS POSSIBLE FROM THE
INFORMATION AVAILABLE. THE SURVEYOR HAS NOT PHYSICALLY
LOCATED THE UNDERGROUND UTILITIES.
2.CONTRACTOR SHALL VERIFY DEPTHS OF ALL EXISTING ONSITE
UTILITIES PRIOR TO CONSTRUCTION TO CONFIRM THERE ARE NOT
ANY CONFLICTS WITH OTHER UTILITIES, STORM SEWERS OR STREETS.
CONFLICTS AFTER CONSTRUCTION BEGINS ARE SOLELY THE
CONTRACTOR'S RESPONSIBILITY.
3.STORM WATER CONTROLS SHOWN ON THE INITIAL SWPPP (C300)
SHOULD BE INSTALLED AS SOON AS PRACTICAL.
4.IF IT WILL BE NECESSARY TO RELOCATE EXISTING UTILITIES, THE
EXPENSE OF SUCH RELOCATION SHALL BE THE RESPONSIBILITY OF
THE DEVELOPER. ALL UTILITY POLES SHALL BE LOCATED WITHIN
ONE FOOT OF THE PROPOSED RIGHT-OF-WAY.
LEGEND
EXISTING FEATURES
ELECTRIC LINE, UNDERGROUND
FIBER OPTIC LINE
GAS MAIN
ELECTRIC LINE, OVERHEAD
TELEPHONE LINE
WATER MAIN
SEWER, SANITARY
SEWER, STORM
CONTOUR
FENCE LINE
WATER FLOWLINE
NORMAL WATER ELEVATION
FLOODWAY FRINGE (PRE-PUBLISHED FLOOD LINE)
TREE LINE
MAILBOX
UTILITY POLE
GUY ANCHOR
TELECOM, FIBER OPTIC HANDHOLE
ELECTRICAL, ACCESS COVER
WATER, HYDRANT
WATER, VALVE
RISER
GATE POST
SIGN
RIGHT-OF-WAY MARKER
TREE
PROPOSED FEATURES
DENOTES CONSTRUCTION LIMITS
DENOTES TREE PROTECTION FENCE LOCATION(S)