HomeMy WebLinkAboutC101-Existing Conditions & Demo PlansE.T
.
U.
P
.
EAC
U.
P
.
U.
P
.
U.
P
.
U.
P
.
U.
P
.
U.
P
.
84
3
.
5
7
2I
N
P
V
C
V
R
T
15' Electrical & Telecomm. Easement
Instr. No. 2019025955 &
Instr. No. 2019031338
Lot 5Lot 4 Lot 6 Lot 7
DONNYBROOK ADDITION
Plat Book 2, Pages 233-234
DONNYBROOK ADDITION
Plat Book 2, Pages 233-234
Lo
t
1
9
Lo
t
2
0
Lo
t
2
1
Lo
t
2
2
DO
N
N
Y
B
R
O
O
K
W
O
O
D
S
Pl
a
t
B
o
o
k
2
,
P
a
g
e
s
2
3
3
-
2
3
4
MONON FARMS CONDOMINIUMS
Plat Cabinet 3, Slide 651
Inst. No. 200500039345
VEGETATION ONLY AS
REQUIRED FOR GRADING /
CLEAR AND GRUB
VEGETATION ONLY AS
REQUIRED FOR SANITARY
SEWER CONSTRUCTION
DA
T
E
MA
R
K
RE
V
I
S
I
O
N
S
BY
S & A JOB NO.
SHEET NO.
DRAWN BY:CHECKED BY:
TH
I
S
D
R
A
W
I
N
G
I
S
N
O
T
I
N
T
E
N
D
E
D
T
O
B
E
RE
P
R
E
S
E
N
T
E
D
A
S
A
R
E
T
R
A
C
E
M
E
N
T
O
R
OR
I
G
I
N
A
L
B
O
U
N
D
A
R
Y
S
U
R
V
E
Y
,
A
R
O
U
T
E
S
U
R
V
E
Y
O
R
A
S
U
R
V
E
Y
O
R
LO
C
A
T
I
O
N
R
E
P
O
R
T
.
CE
R
T
I
F
I
E
D
:
S
T
O
E
P
P
E
L
W
E
R
T
H
A
L
W
A
Y
S
O
N
79
6
5
E
a
s
t
1
0
6
t
h
S
t
r
e
e
t
,
F
i
s
h
e
r
s
,
I
N
4
6
0
3
8
-
2
5
0
5
ph
o
n
e
:
3
1
7
.
8
4
9
.
5
9
3
5
f
a
x
:
3
1
7
.
8
4
9
.
5
9
4
2
EX
I
S
T
I
N
G
C
O
N
D
I
T
I
O
N
S
/
D
E
M
O
P
L
A
N
S
C101
111895GBC
PDR BKR
CL
A
Y
T
O
W
N
S
H
I
P
HA
M
I
L
T
O
N
C
O
U
N
T
Y
,
I
N
D
I
A
N
A
Fi
l
e
N
a
m
e
:
S:
\
1
1
1
8
9
5
G
B
C
\
D
W
G
\
C
1
0
0
-
E
x
i
s
t
i
n
g
C
o
n
d
i
t
i
o
n
s
&
D
e
m
o
P
l
a
n
s
.
d
w
g
-
C1
0
1
Mo
d
i
f
i
e
d
/
B
y
:
Ju
n
e
2
6
,
2
0
2
5
1
1
:
1
1
:
5
9
A
M
/
pr
i
c
h
a
r
d
s
Pl
o
t
t
e
d
/
B
y
:
Ju
n
e
2
6
,
2
0
2
5
1
1
:
2
2
:
2
7
A
M
/
Pa
u
l
R
i
c
h
a
r
d
s
06
/
2
6
/
2
5
SW
I
N
L
E
Y
F
O
R
E
S
T
12
2
5
E
A
S
T
1
1
6
t
h
S
T
R
E
E
T
MA
T
C
H
L
I
N
E
"
A
"
-
S
E
E
S
H
E
E
T
C
1
0
0
MA
T
C
H
L
I
N
E
"
A
"
-
S
E
E
S
H
E
E
T
C
1
0
0
GRAPHIC SCALE
0'
( IN FEET )
30'15'30'
1" = 30'
BENCHMARK DATA
ORIGINATING BENCHMARK:
BENCHMARK ELEVATIONS FOR THIS PROJECT WERE DERIVED USING THE
NATIONAL GEODETIC SURVEY ONLINE POSITIONING USER SERVICE
(O.P.U.S) AND ARE REFERENCED TO THE NAVD '88 DATUM.
SITE TBMs:
TBM #1: A CUT SQUARE ON TOP OF THE CONCRETE CURB ON THE SOUTH
SIDE OF 116th STREET, IMMEDIATELY EAST OF THE ENTRANCE TO THE
GRAVEL DRIVE ON THE WEST SIDE OF THE SITE.
EL: 832.38 (NAVD 88)
TBM #2: A CUT "X" ON TOP OF THE CONCRETE TOP OF THE BRICK
HEADWALL OVER CARMEL CREEK, AT THE NORTHWEST CORNER OF THE
WALL.
EL: 830.09 (NAVD 88)
NOTES
1.THIS SURVEY REFLECTS ABOVE GROUND INDICATIONS OF UTILITIES
AND INFORMATION AVAILABLE FROM UTILITY COMPANIES. THE
SURVEYOR MAKES NO GUARANTEE THAT THE UNDERGROUND
UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA,
EITHER IN SERVICE OR ABANDONED. THE SURVEYOR FURTHER DOES
NOT WARRANT THAT THE UNDERGROUND UTILITIES SHOWN ARE IN
THE EXACT LOCATION INDICATED, ALTHOUGH HE DOES CERTIFY
THAT THEY ARE LOCATED AS ACCURATELY AS POSSIBLE FROM THE
INFORMATION AVAILABLE. THE SURVEYOR HAS NOT PHYSICALLY
LOCATED THE UNDERGROUND UTILITIES.
2.CONTRACTOR SHALL VERIFY DEPTHS OF ALL EXISTING ONSITE
UTILITIES PRIOR TO CONSTRUCTION TO CONFIRM THERE ARE NOT
ANY CONFLICTS WITH OTHER UTILITIES, STORM SEWERS OR STREETS.
CONFLICTS AFTER CONSTRUCTION BEGINS ARE SOLELY THE
CONTRACTOR'S RESPONSIBILITY.
3.STORM WATER CONTROLS SHOWN ON THE INITIAL SWPPP (C300)
SHOULD BE INSTALLED AS SOON AS PRACTICAL.
4.IF IT WILL BE NECESSARY TO RELOCATE EXISTING UTILITIES, THE
EXPENSE OF SUCH RELOCATION SHALL BE THE RESPONSIBILITY OF
THE DEVELOPER. ALL UTILITY POLES SHALL BE LOCATED WITHIN
ONE FOOT OF THE PROPOSED RIGHT-OF-WAY.
LEGEND
EXISTING FEATURES
ELECTRIC LINE, UNDERGROUND
FIBER OPTIC LINE
GAS MAIN
ELECTRIC LINE, OVERHEAD
TELEPHONE LINE
WATER MAIN
SEWER, SANITARY
SEWER, STORM
CONTOUR
FENCE LINE
WATER FLOWLINE
NORMAL WATER ELEVATION
FLOODWAY FRINGE (PRE-PUBLISHED FLOOD LINE)
TREE LINE
MAILBOX
UTILITY POLE
GUY ANCHOR
TELECOM, FIBER OPTIC HANDHOLE
ELECTRICAL, ACCESS COVER
WATER, HYDRANT
WATER, VALVE
RISER
GATE POST
SIGN
RIGHT-OF-WAY MARKER
TREE
PROPOSED FEATURES
DENOTES CONSTRUCTION LIMITS
DENOTES TREE PROTECTION FENCE LOCATION(S)