Loading...
HomeMy WebLinkAboutC300B-SWPPP - Initial PlansE.T . U. P . EAC U. P . U. P . U. P . U. P . U. P . U. P . 15' Electrical & Telecomm. Easement Instr. No. 2019025955 & Instr. No. 2019031338 Lot 5Lot 4 Lot 6 Lot 7 DONNYBROOK ADDITION Plat Book 2, Pages 233-234 DONNYBROOK ADDITION Plat Book 2, Pages 233-234 Lo t 1 9 Lo t 2 0 Lo t 2 1 Lo t 2 2 DO N N Y B R O O K W O O D S Pl a t B o o k 2 , P a g e s 2 3 3 - 2 3 4 MONON FARMS CONDOMINIUMS Plat Cabinet 3, Slide 651 Inst. No. 200500039345 DA T E MA R K RE V I S I O N S BY S & A JOB NO. SHEET NO. DRAWN BY:CHECKED BY: TH I S D R A W I N G I S N O T I N T E N D E D T O B E RE P R E S E N T E D A S A R E T R A C E M E N T O R OR I G I N A L B O U N D A R Y S U R V E Y , A R O U T E S U R V E Y O R A S U R V E Y O R LO C A T I O N R E P O R T . CE R T I F I E D : S T O E P P E L W E R T H A L W A Y S O N 79 6 5 E a s t 1 0 6 t h S t r e e t , F i s h e r s , I N 4 6 0 3 8 - 2 5 0 5 ph o n e : 3 1 7 . 8 4 9 . 5 9 3 5 f a x : 3 1 7 . 8 4 9 . 5 9 4 2 SW P P P - I N I T I A L P L A N S C300B 111895GBC PDR BKR CL A Y T O W N S H I P HA M I L T O N C O U N T Y , I N D I A N A Fi l e N a m e : S: \ 1 1 1 8 9 5 G B C \ D W G \ C 3 0 0 - S W P P P - I n i t i a l P l a n s . d w g - C3 0 0 B Mo d i f i e d / B y : Ju n e 2 6 , 2 0 2 5 9 : 5 1 : 4 0 A M / pr i c h a r d s Pl o t t e d / B y : Ju n e 2 6 , 2 0 2 5 1 1 : 2 2 : 1 5 A M / Pa u l R i c h a r d s 06 / 2 6 / 2 5 SW I N L E Y F O R E S T 12 2 5 E A S T 1 1 6 t h S T R E E T MA T C H L I N E " A " - S E E S H E E T C 3 0 0 A MA T C H L I N E " A " - S E E S H E E T C 3 0 0 A GRAPHIC SCALE 0' ( IN FEET ) 30'15'30' 1" = 30' GRAPHIC SCALE 0' ( IN FEET ) 30'15'30' 1" = 30' THIS SHEET TO BE USED FOR EROSION CONTROL ONLY. NOTES 1.ANY ADDITIONAL EROSION CONTROL MEASURES MAY BE REQUIRED IN THE FIELD BY THE INSPECTOR. 2.IF SITE REMAINS INACTIVE FOR A PERIOD OF 2 WEEKS, THEN STABILIZATION IS REQUIRED TO TAKE PLACE IN THE FORM OF TEMPORARY SEEDING, MULCH, OR SPRAY ON POLYMER. 3.CONTRACTOR TO STAY WITHIN CONSTRUCTION LIMITS TO MAINTAIN VEGETATIVE BUFFER AREAS. 4.NO EARTH DISTURBING ACTIVITIES MAY TAKE PLACE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. 5.ANY DISCHARGE OF CONTAMINATED WATER DUE TO DEWATERING SHALL OUTLET THROUGH EXISTING VEGETATION OR FILTER BAGS THAT WILL NOT ADVERSELY IMPACT STORM WATER QUALITY. PERSON RESPONSIBLE FOR EROSION CONTROL TIM BARR - GRADISON LAND DEVELOPMENT 6330 EAST 75th STREET, SUITE 156 INDIANAPOLIS, INDIANA 46250 PHONE:(317) 538-1941 EMAIL:tbarr@gradison.net BENCHMARK DATA ORIGINATING BENCHMARK: BENCHMARK ELEVATIONS FOR THIS PROJECT WERE DERIVED USING THE NATIONAL GEODETIC SURVEY ONLINE POSITIONING USER SERVICE (O.P.U.S) AND ARE REFERENCED TO THE NAVD '88 DATUM. SITE TBMs: TBM #1: A CUT SQUARE ON TOP OF THE CONCRETE CURB ON THE SOUTH SIDE OF 116th STREET, IMMEDIATELY EAST OF THE ENTRANCE TO THE GRAVEL DRIVE ON THE WEST SIDE OF THE SITE. EL: 832.38 (NAVD 88) TBM #2: A CUT "X" ON TOP OF THE CONCRETE TOP OF THE BRICK HEADWALL OVER CARMEL CREEK, AT THE NORTHWEST CORNER OF THE WALL. EL: 830.09 (NAVD 88) LEGEND FLOODWAY FRINGE (PRE-PUBLISHED FLOOD LINE) DENOTES CONSTRUCTION LIMITS DENOTES SILT FENCE DENOTES TREE PROTECTION FENCE LOCATION(S) TEMPORARY BELOW GRADE "DROP INLET PROTECTION BASKET" LOCATION(S) WHERE STORMWATER ENTERS / DISCHARGES FROM SITE