Loading...
HomeMy WebLinkAboutC304B-SWPPP - DetailsDA T E MA R K RE V I S I O N S BY S & A JOB NO. SHEET NO. DRAWN BY:CHECKED BY: TH I S D R A W I N G I S N O T I N T E N D E D T O B E RE P R E S E N T E D A S A R E T R A C E M E N T O R OR I G I N A L B O U N D A R Y S U R V E Y , A R O U T E S U R V E Y O R A S U R V E Y O R LO C A T I O N R E P O R T . CE R T I F I E D : S T O E P P E L W E R T H A L W A Y S O N 79 6 5 E a s t 1 0 6 t h S t r e e t , F i s h e r s , I N 4 6 0 3 8 - 2 5 0 5 ph o n e : 3 1 7 . 8 4 9 . 5 9 3 5 f a x : 3 1 7 . 8 4 9 . 5 9 4 2 SW P P P - S P E C I F I C A T I O N S & D E T A I L S C304B 111895GBC PDR BKR CL A Y T O W N S H I P HA M I L T O N C O U N T Y , I N D I A N A Fi l e N a m e : S: \ 1 1 1 8 9 5 G B C \ D W G \ C 3 0 4 - S W P P P - D e t a i l s . d w g - C3 0 4 B Mo d i f i e d / B y : Ju n e 9 , 2 0 2 5 1 : 5 0 : 5 9 P M / pr i c h a r d s Pl o t t e d / B y : Ju n e 2 6 , 2 0 2 5 1 1 : 2 4 : 4 5 A M / Pa u l R i c h a r d s 06 / 2 6 / 2 5 SW I N L E Y F O R E S T 12 2 5 E A S T 1 1 6 t h S T R E E T THIS SHEET TO BE USED FOR EROSION CONTROL ONLY. PERSON RESPONSIBLE FOR EROSION CONTROL MARK GRADISON - SWINLEY FOREST, LLC 6330 EAST 75th STREET, SUITE 156 INDIANAPOLIS, INDIANA 46250 PHONE:(317) 506-1037 EMAIL:mgradison@gradison.net REAR CURB GUARD FLAP WITH MAGNETIC TIE-DOWNS STANDARD 2" OVERFLOW AREA LIFT HANDLES 11 GAUGE STEEL SUSPENSION SYSTEM STAINLESS STEEL CLAMPING BAND 2-PLY REPLACEABLE SEDIMENT BAGS WITH GEOTEXTILE FILTER FABRIC TYPICAL CURB BOX INLET FILTER TYPICAL FLAT / RECTANGULAR / ROLLED CURB INLET FILTER TYPICAL ROUND INLET FILTER TYPICAL INSTALLATION INSTALLATION 1.REMOVE GRATE. 2.DROP FLEXSTORM INLET FILTER ONTO LOAD BEARING LIP OF CASTING OR CONCRETE STRUCTURE. 3.REPLACE GRATE. IPP FLeXstorm INLET FILTER SPECIFICATIONS MATERIAL PROPERTY TEST METHOD VALUE (min ave) INNER FILTER BAG SPECS (2 ft³ min vol)NON-WOVEN WOVEN MONO GRAB TANSILE ASTM D 4632 100 lbs.200 lbs. PUNCTURE STRENGTH ASTM D 4833 65 lbs.90 lbs. TRAPEZOIDAL TEAR ASTM D 4533 45 lbs.75 lbs. UV RESISTANCE ASTM D 4355 70% at 500 hrs 90% APP OPEN SIZE (AOS)ASTM D 4751 70 sieve (0.212mm)40 seive (0.425mm) PERMITTIVITY ASTM D 4491 2.0 / sec.2.1 / sec. WATER FLOW RATE ASTM D 4491 145 gpm / sqft 145 gpm / sqft POLYESTER OUTER REINFORCEMENT BAG SPECIFICATIONS WEIGHT ASTM D 3776 4.55 oz / sqyd ± 15% THICKNESS ASTM D 1777 0.040 ± 0.005 FRAME CONSTRUCTION A36 STRUCTURAL STEEL; 11 GAUGE; ZINC PLATED ASTM A 576 TENSILE STRENGTH > 58,000 psi; YIELD STRENGTH > 36,000 psi CURB INLET SEDIMENT CONTROL DEVICE OR ACCEPTABLE DEVICE BY CITY OF CARMEL WITH IN PUBLIC RIGHT OF WAY NOT-TO-SCALE FILTER FABRIC YARD INLET CASTING #4 GAUGE WIRE (TYP.) SILT PROTECTION FOR DITCH GRATE CASTINGS (NEENAH R-4342) DROP INLET PROTECTION BASKET DETAIL NOT-TO-SCALE MAINTENANCE 1.INSPECT THE DROP INLET PROTECTION AFTER EACH STORM EVENT, AND MAKE NEEDED REPAIRS IMMEDIATELY. 2.REMOVE SEDIMENT FROM THE POOL AREA TO ENSURE ADEQUATE RUNOFF STORAGE FOR THE NEXT RAIN. 3.WHEN THE CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED, REMOVE ALL BARRELS, CONSTRUCTION MATERIAL, AND SEDIMENT AND DISPOSE OF PROPERLY, GRADE THE DISTURBED AREA TO THE ELEVATION OF THE TOP OF THE INLET AND STABILIZE. NOTES: 1.IT IS THE INTENT OF THIS DEVICE TO DETAIN WATER FOR THE PURPOSE OF ALLOWING SUSPENDED SOLIDS IN THE WATER TO SETTLE OUT BEFORE THE WATER ENTERS THE STORM STRUCTURE. SOME FILTERING WILL OCCUR AS WATER PASSES THROUGH THE DEVICE. 2.THE BOTTOM OF THIS DEVICE IS TO SEAL AGAINST THE FLAT OUTER PART OF THE CASTING. THE OVERALL DIMENSION OF THE BASKET SHALL BE NO SMALLER THAN THE WATER INLET PERFORATIONS IN THE CASTING AND NO LARGER THAN THE OUTER DIMENSIONS OF THE CASTING. THE HEIGHT SHALL BE 15". 3.THE BASKET FRAME SHALL BE WELDED WIRE MESH ROLLED OR BENT AND WELDED TO ITSELF TO FIT THE CASTING. THE WIRE SIZE SHALL BE NO SMALLER THAN .149" DIA. AND OPENINGS NO LARGER THAN 18 SQ. IN. IT IS IMPORTANT THAT THE BOTTOM OF THE WIRE FRAME BE SMOOTH SO AS NOT TO ALLOW ANY LEAKAGE BETWEEN THE BASKET AND CASTING. THE TOP OF THE BASKET SHALL BE OPEN TO PREVENT FLOODING DURING HEAVY STORM EVENTS. 4.FABRIC SHALL BE WOVEN POLYPROPYLENE ALLOWING 15 - 25 GAL./MIN./SQ. IN. IF NON-WOVEN FABRIC IS USED, THE MAINTENANCE INTERVALS SHOULD BE INCREASED TO REPLACE SILT LADEN FABRIC. THE FABRIC SHALL BE ATTACHED TO THE FRAME AND FOLDED UNDER THE BOTTOM TO HELP SEAL AGAINST THE CASTING. 5.THIS DEVICE SHOULD BE USED IN CONJUNCTION WITH OTHER BEST MANAGEMENT PRACTICES TO MAXIMIZE THE EFFICIENCY OF THE EROSION CONTROL PLAN. 6.SUPPLIERS FOR THIS PRODUCT INCLUDE: LAKESIDE SUPPLY (317) 281-2661 TURFGRASS INC.(317) 894-3276 5'-0" 1' - 0 " ( M I N . ) ROCK ABUTMENT SPILLWAY CREST ELEV. ROCK APRON FILTER FABRIC 1' - 6 " ( M I N . ) 1'-0" (MIN.) UPSTREAM GRAVEL FACING 5'-0" (MIN.) 2' - 0 " #8 STONE FACING 1 ' - 0 " ( M I N . ) 6" RIP-RAP 5'-0 " FL O W SEE SHEET C301A FOR SPILLWAY ELEV. ROCK HORSE SHOE DAM DETAIL NOT TO SCALE TOP VIEW 300 275 250 225 200 175 150 125 100 75 50 25 0 4:1 3:1 2:1 1:1 LO W F L O W CH A N N E L ME D / H I G H F L O W CH A N N E L A N D SH O R E L I N E DC C B C B B C A B A SLOPE GRADIENT SL O P E L E N G T H ( F T . ) 6' 3' 3' 6' 3' 1.5' 3' 4' 2' 4' 2' 3' 1.5' 4' 2' 20"3' 1 STAPLE PER SQ. YD. 11 2 STAPLES PER SQ. YD. 2 STAPLES PER SQ. YD. 312 STAPLES PER SQ. YD. A B C D STAPLE PATTERNS APPLY TO ALL NORTH AMERICAN GREEN EROSION CONTROL BLANKETS. STAPLE PATTERNS WILL VARY DEPENDING UPON SLOPE LENGTH, SLOPE GRADE, SOIL TYPE, AND AVERAGE ANNUAL RAINFALL. EROSION CONTROL BLANKET STAPLE PATTERN GUIDE NOT TO SCALE PLASTIC WASHERS ON TIES (TYP.) CURB INLET PROTECTION MAT RUNOFF NOTES: 1.INSPECT AND REPAIR AS NEEDED, AND REMOVE ANY ACCUMULATED SEDIMENTS AFTER EVERY STORM. 2.THE MAT IS DESIGNED TO BE ATTACHED OVER THE TOP OF THE CURB INLET GRATE WITH PLASTIC CABLE TIES (75# STRENGTH MIN.). THE OVERALL DIMENSION OF THE MAT SHALL ALLOW FOR 2" BEYOND THE WATER INLET PERFORATIONS IN THE CASTING. THE EXCEPTION TO THIS WOULD BE ALONG THE TOP WHERE THE GRATE SHALL BE EXPOSED TO ALLOW OVERFLOW DURING HEAVY STORM EVENTS. THE COMPOSITE CURB INLET PROTECTION MAT SHALL BE A MACHINE-PRODUCED MAT OF 100% COCONUT FIBER MATRIX INCORPORATED INTO A PERMANENT THREE-DIMENSIONAL MATTING. THERE SHALL BE 2 LAYERS OF MATRIX EVENLY DISTRIBUTED ACROSS THE ENTIRE WIDTH OF THE MATTING. THERE SHALL BE 4 LAYERS OF SUPER HEAVY DUTY UV STABILIZED POLYPROPYLENE NET WITH 0.5"X0.5" OPENINGS AND 2 LAYERS ULTRA HEAVY DUTY UV STABILIZED DRAMATICALLY CORRUGATED(CRIMPED) INTERMEDIATE POLYPROPYLENE NETTING WITH 0.5"X0.5" OPENINGS. THE MAT SHALL BE STITCHED WITH UV STABILIZED POLYPROPYLENE AT 1.50" SPACING. THIS DEVICE SHOULD BE USED IN CONJUNCTION WITH OTHER BMP'S TO MAXIMIZE THE EFFICIENCY OF THE EROSION CONTROL PLAN. 3.THE MATS ARE TO BE CHECKED EVERY TWO WEEKS AND AFTER EVERY STORM EVENT FOR MAINTENANCE AND/OR REPAIR AND REPLACEMENT. CURB INLET PROTECTION DETAIL NOT-TO-SCALE SILT FENCE INSTALLATION GUIDELINES SPECIFICATIONS FOR INSTALLING THE SILT FENCE SHOULD BE IN CONFORMANCE WITH THE FOLLOWING. MATERIALS 1.SYNTHETIC FILTER FABRIC SHALL BE A PERVIOUS SHEET OF PROPYLENE, NYLON. POLYESTER OR ETHYLENE YARN AND SHALL BE CERTIFIED BY THE MANUFACTURER OR SUPPLIER AS CONFORMING TO THE FOLLOWING REQUIREMENTS: SYNTHETIC FILTER FABRIC SHALL CONTAIN ULTRAVIOLET RAY INHIBITORS AND STABILIZERS TO PROVIDE A MINIMUM OF 6 MONTHS OF EXPECTED USABLE CONSTRUCTION LIFE. 2.BURLAP SHALL BE 10 OUNCES PER SQUARE YARD FABRIC. 3.POSTS FOR SILT FENCES SHALL BE EITHER 4 in (10 cm) DIAMETER WOOD OR 1.33 lbs / ft (2 kg/m) STEEL WITH A MINIMUM LENGTH OF 5 ft (1.5 m). STEEL POSTS SHALL HAVE PROJECTIONS FOR FASTENING WIRE TO THEM. 4.STAKES FOR FILTER BARRIERS SHALL BE 1 x 2 in (2.5 x 5 cm) WOOD OR EQUIVALENT METAL WITH A MINIMUM LENGTH OF 3 ft (0.9 m). 5.WIRE FENCE REINFORCEMENT FOR SILT FENCES USING STANDARD STRENGTH FILTER CLOTH SHALL BE A MINIMUM OF 3 ft (0.9 m) IN HEIGHT, A MINIMUM OF 14 GAUGE AND SHALL HAVE A MAXIMUM MESH SPACING OF 6 in (15 cm). FILTER BARRIER 1.THIS SEDIMENT BARRIER MAY BE CONSTRUCTED USING BURLAP OR STANDARD STRENGTH SYNTHETIC FILTER FABRIC. IT IS DESIGNED FOR LOW OR MODERATE FLOWS. 2.THE HEIGHT OF A FILTER BARRIER SHALL BE A MINIMUM OF 15 in (381 mm) AND SHALL NOT EXCEED 18 in (457 mm). 3.BURLAP OR STANDARD STRENGTH SYNTHETIC FILTER FABRIC SHALL BE PURCHASED IN A CONTINUOUS ROLL AND CUT TO THE LENGTH OF THE BARRIER TO AVOID THE USE OF JOINTS. 4.THE STAKES SHALL BE SPACED A MAXIMUM OF 3 ft (0.9 m) APART AT THE BARRIER LOCATION AND DRIVEN SECURELY INTO THE GROUND - A MINIMUM OF 8 in (203 mm). 5.A TRENCH SHALL BE EXCAVATED APPROXIMATELY 4 in (102 mm) WIDE AND 4 in (102 mm) DEEP ALONG THE LINE OF STAKES AND UPSLOPE FROM THE BARRIER. 6.THE FILTER MATERIAL SHALL BE STAPLED TO THE WOODEN STAKES, AND 8 in (203 mm) OF THE FABRIC SHALL BE EXTENDED INTO THE TRENCH. HEAVY DUTY WIRE STAPLES AT LEAST 1/2 in (13 mm) LONG SHALL BE USED. FILTER MATERIAL SHALL NOT BE STAPLED TO EXISTING TREES. 7.THE TRENCH SHALL BE BACKFILLED AND THE SOIL COMPACTED OVER THE FILTER MATERIAL. 8.IF A FILTER BARRIER IS TO BE CONSTRUCTED ACROSS A DITCH LINE OR SWALE, THE BARRIER SHALL BE OF SUFFICIENT LENGTH TO ELIMINATE END FLOW, AND THE PLAN CONFIGURATION SHALL RESEMBLE AN ARC OR HORSESHOE WITH THE ENDS ORIENTED UPSLOPE. 9.FILTER BARRIERS SHALL BE REMOVED WHEN THEY HAVE SERVED THEIR USEFUL PURPOSE, BUT NOT BEFORE THE UPSLOPE AREA HAS BEEN PERMANENTLY STABILIZED. SILT FENCE 1.THIS SEDIMENT BARRIER UTILIZES STANDARD STRENGTH OR EXTRA STRENGTH SYNTHETIC FILTER FABRICS. IT IS DESIGNED FOR SITUATIONS IN WHICH ONLY SHEET OR OVERLAND FLOWS ARE EXPECTED. 2.THE HEIGHT OF A SILT FENCE SHALL NOT EXCEED 3 ft (0.9 m); (HIGHER FENCES MAY IMPOUND VOLUMES OF WATER SUFFICIENT TO CAUSE FAILURE OF THE STRUCTURE). 3.THE FILTER FABRIC SHALL BE PURCHASED IN A CONTINUOUS ROLL OUT TO THE LENGTH OF THE BARRIER TO AVOID THE USE OF JOINTS. WHEN JOINTS ARE NECESSARY, FILTER CLOTH SHALL BE SPLICED TOGETHER ONLY AT A SUPPORT POST, WITH A MINIMUM 6 in (152 mm) OVERLAP, AND SECURELY SEALED. 4.POSTS SHALL BE SPACED A MAXIMUM OF 10 ft (3 m) APART AT THE BARRIER LOCATION AND DRIVEN SECURELY INTO THE GROUND (MINIMUM OF 12 in (305 mm). WHEN EXTRA STRENGTH FABRIC IS USED WITHOUT THE WIRE SUPPORT FENCE, POST SPACING SHALL NOT EXCEED 6 ft (1.85 m). 5.A TRENCH SHALL BE EXCAVATED APPROXIMATELY 4 in (102 mm) WIDE AND 8 in (203 mm) DEEP ALONG THE LINE OF POSTS AND UPSLOPE FROM THE BARRIER. 6.WHEN STANDARD STRENGTH FILTER FABRIC IS USED, A WIRE MESH SUPPORT FENCE SHALL BE FASTENED SECURELY TO THE UPSLOPE SIDE OF THE POSTS USING HEAVY DUTY WIRE STAPLES AT LEAST 1 in (25 mm) LONG, TIE WIRES OR HOG RINGS. THE WIRE SHALL EXTEND INTO THE TRENCH A MINIMUM OF 2 in (51 mm) AND SHALL NOT EXTEND MORE THAN 3 ft (0.9 m) ABOVE THE ORIGINAL GROUND SURFACE. 7.THE STANDARD STRENGTH FILTER FABRIC SHALL BE STAPLED OR WIRED TO THE FENCE, AND 8 in (203 mm) OF THE FABRIC SHALL BE EXTENDED INTO THE TRENCH. THE FABRIC SHALL NOT EXTEND MORE THAN 3 ft (0.9 m) ABOVE THE ORIGINAL GROUND SURFACE. 8.WHEN EXTRA STRENGTH FILTER FABRIC AND CLOSER POST SPACING ARE USED, THE WIRE MESH SUPPORT FENCE MAY BE ELIMINATED. IN SUCH CASES THE FILTER FABRIC IS STAPLED OR WIRED DIRECTLY TO THE POSTS. 9.THE TRENCH SHALL BE BACKFILLED AND THE SOIL COMPACTED OVER THE FILTER FABRIC. 10.SILT FENCES SHALL BE REMOVED WHEN THEY HAVE SERVED THEIR USEFUL PURPOSE, BUT NOT BEFORE THE UPSLOPE AREA HAS BEEN PERMANENTLY STABILIZED. INSTALL PARALLEL TO THE CONTOUR OF THE LAND AND WITH NO MORE THAN 0.25 acre (0.1 hectare) DRAINAGE AREA PER 100 ft (30 m) OF FENCE. EXTEND ENDS UPSLOPE ENOUGH TO ALLOW WATER TO POND BEHIND THE FENCE. FENCE POSTS BURIED A MINIMUM OF 15 in (381 mm). EXCAVATE A TRENCH 4 in (102 mm) WIDE AND 8 in (203 mm) DEEP. INSTALL FENCE WITH STAKES ON THE DOWN SLOPE SIDE. BURY 12 in (305 mm) OF FABRIC IN THE TRENCH, EXTENDING THE BOTTOM 4 in (102 mm) TOWARD THE UPSLOPE SIDE. BACKFILL TRENCH WITH SOIL MATERIAL, AND COMPACT. JOIN SILT FENCE SECTIONS BY OVERLAPPING SECTIONS AND NAILING WITH LATH TO THE NEAREST POST. INSPECT TWICE A WEEK AND AFTER EACH STORM EVENT, REPAIRING AS NEEDED AND REMOVING SEDIMENT DEPOSITS WHEN THEY REACH ONE-HALF THE FENCE HEIGHT. SPECIFICATIONS MINIMUMS FOR SILT FENCE FABRIC PHYSICAL PROPERTY WOVEN FABRIC NON-WOVEN FABRIC FILTERING EFFICIENCY 85%85% TENSILE STRENGTH AT 20% ELONGATION: STANDARD STRENGTH 30 lbs / linear in 50 lbs / linear in EXTRA STRENGTH 50 lbs / linear in 75 lbs / linear in SLURRY FLOW RATE 0.3 gal / min / sqft 4.5 gal / min / sqft WATER FLOW RATE 15 gal / min / sqft 220 gal / min / sqft UV RESISTANCE 70%85%