Loading...
HomeMy WebLinkAboutC400-Street Plan & ProfilesD Y H E.T . U. P . 25' D.&U.E. 25' D.&U.E.68.90' 1 2 R/W 10 ' T . P . E . 10' T.P.E. 35 ' B . L . 25' B.L. 25' B.L. 2.23% 2-yr EL. 825.87 10-yr EL. 826.76 100-yr EL. 828.04 2' RIBBON CURB 2' RIBBON CURB 2' RIBBON CURB 2' RIBBON CURB 406 405 404403 402 407 409 1+50 830.63 2+00 831.16 2+50 832.18 2+75 832.74 3+00 833.30 3+25 833.86 3+50 834.42 3+75 834.97 4+00 835.51 4+25 836.02 4+50 836.52 4+75 837.01 5+00 837.50 5+25 837.99 5+75 839.02 6+25 840.54 6+75 842.62 7+00 843.71 0+30.57 GB 832.08 1+01.13 PVI 830.54 0+38.58 GB 831.92 2+00 PVI 831.16 0+63.63 BVC 831.23 1+20.42 LP 830.45 4+00 PVI 835.51 6+05.07 PVI 839.87 1+72.50 BVC 830.83 1+38.63 EVC 830.53 2+27.50 EVC 831.68 4+37.50 EVC 836.27 3+62.50 BVC 834.70 5+55.07 BVC 838.58 6+55.07 EVC 841.75 7+22.70 GB 844.70 60 ' I . E . E . & D . E . & U . E . 60 ' I . E . E . & D . E . & U . E . 18 ' 18 ' 12 0 ' Instr. No. 2019025955 & Instr. No. 201903133815' Electrical & Telecomm. Easement Instr. No. 2019025955 & Instr. No. 2019031338 408 0.88%-2.75% 1.97%4.36% MONON FARMS CONDOMINIUMS Plat Cabinet 3, Slide 651 Inst. No. 200500039345 Monon Farms Lane E. 1 1 6 t h S t r e e t 20' 10' T.P.E.20' R 20'R 20' B.M.P.E. 10 ' D . & U . E . (Private) DRIVE 1"=30' HORZ. 1"=5' VERT. DRIVE 820 830 840 850 820 830 840 850 GB - S T A . 0 + 2 3 . 0 5 83 2 . 2 3 GB - S T A . 0 + 3 0 . 5 7 83 2 . 0 8 GB - S T A . 0 + 3 8 . 5 8 83 1 . 9 2 GB - S T A . 7 + 2 2 . 7 0 84 4 . 7 0 GB - S T A . 7 + 4 2 . 7 1 84 5 . 4 0 0+00 83 2 . 6 +25 83 2 . 0 83 2 . 1 9 +50 83 1 . 1 83 1 . 6 0 +75 82 9 . 8 83 0 . 9 5 1+00 82 9 . 1 83 0 . 5 5 +25 82 9 . 3 83 0 . 4 5 +50 82 9 . 6 83 0 . 6 3 +75 83 0 . 3 83 0 . 8 5 2+00 83 0 . 9 83 1 . 1 6 +25 83 1 . 4 83 1 . 6 3 +50 83 2 . 1 83 2 . 1 8 +75 83 2 . 7 83 2 . 7 4 3+00 83 3 . 2 83 3 . 3 0 +25 83 3 . 7 83 3 . 8 6 +50 83 4 . 3 83 4 . 4 2 +75 83 4 . 8 83 4 . 9 7 4+00 83 5 . 2 83 5 . 5 1 +25 83 5 . 7 83 6 . 0 2 +50 83 6 . 2 83 6 . 5 2 +75 83 6 . 6 83 7 . 0 1 5+00 83 7 . 3 83 7 . 5 0 +25 83 7 . 8 83 7 . 9 9 +50 83 8 . 4 83 8 . 4 8 +75 83 9 . 0 83 9 . 0 2 6+00 83 9 . 8 83 9 . 7 1 +25 84 0 . 7 84 0 . 5 4 +50 84 1 . 4 84 1 . 5 3 +75 84 3 . 8 84 2 . 6 2 7+00 84 6 . 8 84 3 . 7 1 +25 84 9 . 2 84 4 . 7 8 +50 85 1 . 5 +75 85 3 . 1 BV C S : 0 + 6 3 . 6 3 BV C E : 8 3 1 . 2 3 EV C S : 1 + 3 8 . 6 3 EV C E : 8 3 0 . 5 3 LP STA: 1+20.42 LP EL: 830.45 PVI STA: 1+01.13 PVI EL: 830.20 AD: 3.63% K: 20.65 75.00' VC BV C S : 1 + 7 2 . 5 0 BV C E : 8 3 0 . 8 3 EV C S : 2 + 2 7 . 5 0 EV C E : 8 3 1 . 6 8 LP STA: 1+72.50 LP EL: 830.83 PVI STA: 2+00.00 PVI EL: 831.07 AD: 1.35% K: 40.73 55.00' VC BV C S : 5 + 5 5 . 0 7 BV C E : 8 3 8 . 5 8 EV C S : 6 + 5 5 . 0 7 EV C E : 8 4 1 . 7 5 LP STA: 5+55.07 LP EL: 838.58 PVI STA: 6+05.07 PVI EL: 839.57 AD: 2.40% K: 41.75 100.00' VC BV C S : 3 + 6 2 . 5 0 BV C E : 8 3 4 . 7 0 EV C S : 4 + 3 7 . 5 0 EV C E : 8 3 6 . 2 7 HP STA: 4+37.50 HP EL: 836.27 PVI STA: 4+00.00 PVI EL: 835.53 AD: -0.26% K: 283.25 75.00' VC -2.00%-2.00% -2.75% 0.88% 2.23% 1.97% 4.36% 3.51% EX. 8" PVC SDR-35 IE: 820.98 12" HP PIPE IE: 826.15 54 " 8" WATER IE: 826.32 EX. FIBER OPTIC, SIZE & DEPTH UNKNOWN PROPOSED GRADE EXISTING GRADE U.P. 831.95 E1 832.00 E5 831.90 E4 831.55 E2 831.50 E7 832.15E3 832.20E7 832.35E1 832.40E5 832.30E4 832.20E6 832.20E2 831.99 ME 832.08 ME 832.36ME 832.51ME 6' 8' 8' 6' 831.55 E3 831.60 E6 0. 0 0 % -1.62%-2.50% -1 . 2 5 % -1 . 2 5 % -6.67%0.00% 1. 2 5 % DA T E MA R K RE V I S I O N S BY S & A JOB NO. SHEET NO. DRAWN BY:CHECKED BY: TH I S D R A W I N G I S N O T I N T E N D E D T O B E RE P R E S E N T E D A S A R E T R A C E M E N T O R OR I G I N A L B O U N D A R Y S U R V E Y , A R O U T E S U R V E Y O R A S U R V E Y O R LO C A T I O N R E P O R T . CE R T I F I E D : S T O E P P E L W E R T H A L W A Y S O N 79 6 5 E a s t 1 0 6 t h S t r e e t , F i s h e r s , I N 4 6 0 3 8 - 2 5 0 5 ph o n e : 3 1 7 . 8 4 9 . 5 9 3 5 f a x : 3 1 7 . 8 4 9 . 5 9 4 2 ST R E E T P L A N & P R O F I L E C400 111895GBC PDR BKR CL A Y T O W N S H I P HA M I L T O N C O U N T Y , I N D I A N A Fi l e N a m e : S: \ 1 1 1 8 9 5 G B C \ D W G \ C 4 0 0 - S t r e e t P l a n & P r o f i l e s . d w g - C4 0 0 Mo d i f i e d / B y : Ju n e 2 6 , 2 0 2 5 9 : 2 4 : 0 8 A M / pr i c h a r d s Pl o t t e d / B y : Ju n e 2 6 , 2 0 2 5 1 1 : 2 5 : 0 3 A M / Pa u l R i c h a r d s 06 / 2 6 / 2 5 SW I N L E Y F O R E S T 12 2 5 E A S T 1 1 6 t h S T R E E T 20 ' R ±67 LF 12" WIDE (MIN.) PAVEMENT REPAIR FOR NEW CURB & GUTTER ±5 LF COMBINED CONC. CURB & GUTTER (OR TO NEAREST JOINT) ±4 LF COMBINED CONC. CURB & GUTTER (TO NEAREST JOINT) ±59 LF CLASS I DRIVE CONC. CURB & GUTTER GUTTER LINE MONOLITHIC CURB MONOLITHIC CURB EXISTING COMBINED CONC. CURB & GUTTER EXISTING COMBINED CONC. CURB & GUTTER GRAPHIC SCALE 0' ( IN FEET ) 30'15'30' 1" = 30' BENCHMARK DATA ORIGINATING BENCHMARK: BENCHMARK ELEVATIONS FOR THIS PROJECT WERE DERIVED USING THE NATIONAL GEODETIC SURVEY ONLINE POSITIONING USER SERVICE (O.P.U.S) AND ARE REFERENCED TO THE NAVD '88 DATUM. SITE TBMs: TBM #1: A CUT SQUARE ON TOP OF THE CONCRETE CURB ON THE SOUTH SIDE OF 116th STREET, IMMEDIATELY EAST OF THE ENTRANCE TO THE GRAVEL DRIVE ON THE WEST SIDE OF THE SITE. EL: 832.38 (NAVD 88) TBM #2: A CUT "X" ON TOP OF THE CONCRETE TOP OF THE BRICK HEADWALL OVER CARMEL CREEK, AT THE NORTHWEST CORNER OF THE WALL. EL: 830.09 (NAVD 88) NOTES 1.THIS SURVEY REFLECTS ABOVE GROUND INDICATIONS OF UTILITIES AND INFORMATION AVAILABLE FROM UTILITY COMPANIES. THE SURVEYOR MAKES NO GUARANTEE THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. THE SURVEYOR FURTHER DOES NOT WARRANT THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED, ALTHOUGH HE DOES CERTIFY THAT THEY ARE LOCATED AS ACCURATELY AS POSSIBLE FROM THE INFORMATION AVAILABLE. THE SURVEYOR HAS NOT PHYSICALLY LOCATED THE UNDERGROUND UTILITIES. 2.CONTRACTOR SHALL VERIFY DEPTHS OF ALL EXISTING ONSITE UTILITIES PRIOR TO CONSTRUCTION TO CONFIRM THERE ARE NOT ANY CONFLICTS WITH OTHER UTILITIES, STORM SEWERS OR STREETS. CONFLICTS AFTER CONSTRUCTION BEGINS ARE SOLELY THE CONTRACTOR'S RESPONSIBILITY. 3.FOR INSTALLATION OF STORM MAINS, WATER MAINS, SANITARY MAINS, WATER SERVICE LATERALS, SANITARY SERVICE LATERALS UNDER CITY STREETS, REGARDLESS OF THE JURISDICTION OF THE UTILITY, THE MINIMUM COVER FROM THE TOP OF THE INSTALLED PAVEMENT TO THE TOP OF THE INSTALLED PIPE SHALL BE THE PAVEMENT SECTION THICKNESS (ALL BITUMINOUS AND AGGREGATE MATERIAL ABOVE THE SUBGRADE) PLUS 1-0", BUT UNDER NO CIRCUMSTANCES SHALL THE COVER ALONG ANY PART OF THE PIPE FROM THE FINAL PAVEMENT ELEVATION TO THE TOP OF THE PIPE BE LESS THAN 2.5 FEET. 4.THERE SHALL BE NO MANHOLES OR WATER VALVES WITHIN THE STREET PAVEMENTS, CURBS, SIDEWALKS, OR ASPHALT PATHS. 5.NO EARTH DISTURBING ACTIVITY MAY TAKE PLACE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. 6.DAMAGE TO THE EXISTING RIGHT-OF-WAY SHALL BE RESTORED/REPAIRED TO THE SATISFACTION OF THE CITY AT THE COMPLETION OF THE PROJECT. THE CONTRACTOR IS ENCOURAGED TO INSPECT THE RIGHT-OF-WAY WITH THE CITY PRIOR TO THE START OF CONSTRUCTION TO DOCUMENT THE EXISTING CONDITION OF THE RIGHT-OF-WAY. 7.ALL PAVING WITHIN THE EXISTING AND PROPOSED RIGHT-OF-WAY SHALL CONFORM TO THE REQUIREMENTS OF THE DEPARTMENT OF ENGINEERING. LEGEND DENOTES CONSTRUCTION LIMITS ABBREVIATIONS BVCS BEGIN VERTICAL CURVE STATION BVCE BEGIN VERTICAL CURVE ELEVATION EVCS END VERTICAL CURVE STATION EVCE END VERTICAL CURVE ELEVATION AD GRADE CHANGE PVI POINT OF VERTICAL INTERSECTION VC VERTICAL CURVE K VERTICAL CURVE K-VALUE HP HIGH POINT LP LOW POINT GB GRADE BREAK 1 2 CURB RAMP COMPONENT SLOPE DATA TABLE RAMP No. WALK WIDTH RAMP LENGTH E1 E2 E3 E4 E5 E6 E7 U1 U2 U3 U4 1 8'6'832.35 832.20 832.15 832.30 832.40 832.20 832.20 2.50%1.62%1.25%0.00% 2 8'6'831.95 831.55 831.55 831.90 832.00 831.60 831.50 6.67%0.00%1.25%1.25% CLASS 1 DRIVE (RESIDENTIAL) 6" PCCP FOR APPROACHES CURB RAMP DETAIL SCALE: 1" = 10' 2 0 ' R ±4.5 LF ASPHALT PATH REPLACEMENT ±4.1 LF CONCRETE WALK REPLACEMENT (TO NEAREST JOINT)