HomeMy WebLinkAboutC600-Storm Sewer Plan & ProfilesS S D S U. P . U. P . U. P . S RW S RW U. P . U. P . 825 826 827 828 829 830 824 825 825 826 826 827 827 828 828 829 829 830 830 8 3 1 829829 LOT 2 LOT 1 C.A. #1 VAR. D.U.&B.M.P.E.&L.M.A.E. 10 ' D . & U . E . 10 ' D . & U . E . 10 ' D . & U . E . 25' D.&U.E. 75 ' R a d . 68.90' 1 2 R/W 68.90' 1 2 R/W 50 ' SSD OUTLET INV. 827.50 (SEE DETAIL) 10' T.P.E. 102 L F S W A L E 1. 0 0 % 25' B.L. 8' SPILLWAY @ 828.04' DRY BASIN 2-yr EL. 825.87 10-yr EL. 826.76 100-yr EL. 828.04 13 6 L F 1 2 " 2 . 2 1 % 38 LF 18" 0.57% 71 LF 12" 0.31%140 LF 15" 3.40%160 LF 12" 1.94% 2' RIBBON CURB 2' RIBBON CURB 401 400 404403 402 407 60 ' I . E . E . & D . E . & U . E . 18 ' 18 ' BUFFER EASEMENT 50' FROM TOP OF BANK OF CARMEL CREEK VAR. WATER QUALITY PRESERVATION EASEMENT 15' Electrical & Telecomm. Easement Instr. No. 2019025955 & Instr. No. 2019031338 Approx. Limit of W.R. Fertig Open Regulated Drain (75' from Top of Bank) Approx. Top of Bank W.R. Fertig Open Regulated Drain Var. Width Drainage Access & Maintenance Easement Instr. No. 200300127290 20' Sewer Easement Instr. No. 8702420 15' Electrical & Telecomm. Easement Instr. No. 2019025955 & Instr. No. 2019031338 South R/W 116th Street per INDOT Proj. No. STP-B886 (007) 4' BERM @ 830' 4' BERM @ 830' 16 LF SWALE 1.02%58 LF SWALE 1.00% 408 34 LF SWALE 2.92% 16 LF SWALE 3.18% DONNYBROOK ADDITION Plat Book 2, Pages 233-234 Roland W. Slagle, III et al Inst. No. 2020079971 Lot 3Lot 2Lot 1 MONON FARMS CONDOMINIUMS Plat Cabinet 3, Slide 651 Inst. No. 200500039345 Monon Farms Lane E. 1 1 6 t h S t r e e t - 1 . 0 0 % - 1 . 0 0 % - 1 . 0 0 % TBM #2 TBM #1 20' R 20'R 94 LF SWALE 4.04% 99 LF SWALE 2.83% 10 LF SWALE 1.00%838 839 840 836 837 838 839 840 835 836 83 7 8 3 8 831 832 833 834 835 836 832 833 834 835 836 837 830831832833834835836837 832833834835836837838839840 20' B.M.P.E. 5. 1 6 % 5. 2 9 % FLOODPLAIN COMPENSATORY STORAGE AREA (Private) DRIVE 1"=30' HORZ. 1"=5' VERT. STRM_01 805 810 820 830 805 810 820 830 CO N C R E T E E N D S E C T I O N # 4 0 0 ST A : 0 + 0 0 136 LF 2.21% 1 2 " R C P C L A S S I I I 817.65 814.65 OU T L E T C O N T R O L # 4 0 1 IN L E T T Y P E E ST A : 1 + 3 6 TC : 8 2 7 . 9 5 EX. 12" PVC SDR-26 IE: 806.83± 6" SSD IE: 821.50 PROPOSED GRADE EXISTING GRADE 1"=30' HORZ. 1"=5' VERT. STRM_03 820 830 820 830 YA R D I N L E T # 4 0 8 NY L O P L A S T B A S I N 1 8 ' ' ST A : 0 + 7 1 TC : 8 2 8 . 7 0 EN D S E C T I O N # 4 0 7 ST A : 0 + 0 0 ME T A L E N D S E C T I O N # 4 0 7 ST A : 0 + 0 0 YA R D I N L E T # 4 0 8 NY L O P L A S T B A S I N 1 8 ' ' ST A : 0 + 7 1 TC : 8 2 8 . 7 0 71 LF 0.31% 12" HP PIPE US IE: 826.22 DS IE: 826.00 8" WATER IE: 823.83 68 " 18 " 6" SSD IE: 826.22 PROPOSED GRADE DR I V E (P R I V A T E ) EXISTING GRADE 1"=30' HORZ. 1"=5' VERT. STRM_02 820 830 840 820 830 840WA T E R Q U A L I T Y # 4 0 3 CS - 4 ST A : 0 + 3 8 TC : 8 2 9 . 5 0 YA R D I N L E T # 4 0 4 NY L O P L A S T B A S I N 1 8 ' ' ST A : 1 + 7 8 TC : 8 3 4 . 0 0 140 LF 3.40 % 1 5 " H P P I P E 830.00 825.24 38 LF 0.57% 18" HP PIPE 825.14824.92 ME T A L E N D S E C T I O N # 4 0 2 ST A : 0 + 0 0 160 LF 1.94% 12" HP PIPE US IE: 833.20 DS IE: 830.10 6" SSD IE: 827.00 6" SSD IE: 831.50 PROPOSED GRADE EXISTING GRADE DA T E MA R K RE V I S I O N S BY S & A JOB NO. SHEET NO. DRAWN BY:CHECKED BY: TH I S D R A W I N G I S N O T I N T E N D E D T O B E RE P R E S E N T E D A S A R E T R A C E M E N T O R OR I G I N A L B O U N D A R Y S U R V E Y , A R O U T E S U R V E Y O R A S U R V E Y O R LO C A T I O N R E P O R T . CE R T I F I E D : S T O E P P E L W E R T H A L W A Y S O N 79 6 5 E a s t 1 0 6 t h S t r e e t , F i s h e r s , I N 4 6 0 3 8 - 2 5 0 5 ph o n e : 3 1 7 . 8 4 9 . 5 9 3 5 f a x : 3 1 7 . 8 4 9 . 5 9 4 2 ST O R M S E W E R P L A N & P R O F I L E S C600 111895GBC PDR BKR CL A Y T O W N S H I P HA M I L T O N C O U N T Y , I N D I A N A Fi l e N a m e : S: \ 1 1 1 8 9 5 G B C \ D W G \ C 6 0 0 - S t o r m S e w e r P l a n & P r o f i l e s . d w g - C6 0 0 Mo d i f i e d / B y : Ju n e 2 6 , 2 0 2 5 9 : 3 5 : 3 4 A M / pr i c h a r d s Pl o t t e d / B y : Ju n e 2 6 , 2 0 2 5 1 1 : 2 5 : 3 6 A M / Pa u l R i c h a r d s 06 / 2 6 / 2 5 SW I N L E Y F O R E S T 12 2 5 E A S T 1 1 6 t h S T R E E T GRAPHIC SCALE 0' ( IN FEET ) 30'15'30' 1" = 30' MA T C H L I N E " A " - S E E S H E E T C 6 0 1 MA T C H L I N E " A " - S E E S H E E T C 6 0 1 MA T C H L I N E " B " SE E S H E E T C 6 0 1 BENCHMARK DATA ORIGINATING BENCHMARK: BENCHMARK ELEVATIONS FOR THIS PROJECT WERE DERIVED USING THE NATIONAL GEODETIC SURVEY ONLINE POSITIONING USER SERVICE (O.P.U.S) AND ARE REFERENCED TO THE NAVD '88 DATUM. SITE TBMs: TBM #1: A CUT SQUARE ON TOP OF THE CONCRETE CURB ON THE SOUTH SIDE OF 116th STREET, IMMEDIATELY EAST OF THE ENTRANCE TO THE GRAVEL DRIVE ON THE WEST SIDE OF THE SITE. EL: 832.38 (NAVD 88) TBM #2: A CUT "X" ON TOP OF THE CONCRETE TOP OF THE BRICK HEADWALL OVER CARMEL CREEK, AT THE NORTHWEST CORNER OF THE WALL. EL: 830.09 (NAVD 88) NOTES 1.THIS SURVEY REFLECTS ABOVE GROUND INDICATIONS OF UTILITIES AND INFORMATION AVAILABLE FROM UTILITY COMPANIES. THE SURVEYOR MAKES NO GUARANTEE THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. THE SURVEYOR FURTHER DOES NOT WARRANT THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED, ALTHOUGH HE DOES CERTIFY THAT THEY ARE LOCATED AS ACCURATELY AS POSSIBLE FROM THE INFORMATION AVAILABLE. THE SURVEYOR HAS NOT PHYSICALLY LOCATED THE UNDERGROUND UTILITIES. 2.CONTRACTOR SHALL VERIFY DEPTHS OF ALL EXISTING ONSITE UTILITIES PRIOR TO CONSTRUCTION TO CONFIRM THERE ARE NOT ANY CONFLICTS WITH OTHER UTILITIES, STORM SEWERS OR STREETS. CONFLICTS AFTER CONSTRUCTION BEGINS ARE SOLELY THE CONTRACTOR'S RESPONSIBILITY. 3.ALL STORM STRUCTURES TO RECEIVE SOLID LID CASTINGS ARE TO BE CONSTRUCTED TO PROVIDE ONE 4" RISER RING NO MORE, NO LESS TO ACHIEVE PLAN RIM GRADE. 4.ALL YARD INLETS ARE TO BE CONSTRUCTED AT A TOLERANCE OF +0.00' TO -0.20' OF PLAN GRADE. 5.ALL STORM SEWER CASTINGS SHALL BE LABELED "DUMP NO WASTE-DRAINS TO WATERWAY" 6.ALL SSD'S (SUBSURFACE DRAINS) WILL NEED TO BE DOUBLE WALL SMOOTH BORE PERFORATED (HDPE) PIPE. 7.DEBRIS GUARDS ARE TO BE INSTALLED ON ALL OPEN ENDED INLETS. 8.FOR STORM STRUCTURE SIZING AND CASTING TABLE SEE STANDARD PLAN D-18 ON SHEET C801A. 9.ALL STORM SEWERS WITHIN PUBLIC RIGHT-OF-WAY SHALL BE RCP CLASS III. 10.FOR INSTALLATION OF STORM UNDER CITY STREETS AND COVER REQUIREMENTS, SEE STANDARD DRAWING 10-31 ON SHEET C801A. 11.ALL TOP OF CASTING ELEVATIONS FOR STORM SEWERS SHALL BE CONSTRUCTED WITH A TOLERANCE OF 0.10 FT±. 12.STORM SEWERS FOR THIS DEVELOPMENT WILL BE PUBLIC. 13.MINIMUM COVER FOR PIPE CROSSINGS OF CITY STREETS: THE MINIMUM COVER FROM THE TOP OF THE INSTALLED PAVEMENT TO THE TOP OF THE INSTALLED PIPE SHALL BE THE PAVEMENT SECTION, THICKNESS (ALL BITUMINOUS AND AGGREGATE MATERIAL ABOVE THE SUBGRADE) PLUS 1'-0", BUT UNDER NO CIRCUMSTANCES SHALL THE COVER ALONG ANY PART OF THE PIPE FROM THE FINAL PAVEMENT ELEVATION TO THE TOP OF THE PIPE BE LESS THAN 2.5 FEET. 14.THE STORM SEWER SYSTEM SHALL BE CONSTRUCTED PER DESIGN SPECIFIED AND AS APPROVED BY THE CITY OF CARMEL ON THE FINAL APPROVED CONSTRUCTION PLANS. DESIGN SPECIFIED AND AS APPROVED BY THE CITY OF CARMEL ON THE FINAL APPROVED CONSTRUCTION PLANS. DEVIATIONS FROM THE APPROVED DESIGN SHALL ONLY BE PERMITTED DUE TO SPECIAL CIRCUMSTANCES OR DIFFICULTY DURING CONSTRUCTION AND WILL REQUIRE PRIOR FIELD APPROVAL FROM A DESIGNATED REPRESENTATIVE OF THE CITY OR CARMEL IN ADDITION TO SUPPLEMENTAL APPROVAL BY THE DESIGN ENGINEER. AN EXPLANATION OF ANY SUCH DEVIATION SHALL BE INCLUDED AS A REQUIREMENT ON AS-BUILT/RECORD DRAWINGS SUBMITTED FOR RELEASE OF PERFORMANCE GUARANTEES. APPROVED DESIGN SLOPES IDENTIFIED AS GENERATING VELOCITIES OF 2.5 FPS OR LESS AND 10 FPS OR GREATER (AT FULL FLOW CAPACITY) SHALL REQUIRE AS-BUILT CERTIFICATION AT THE TIME OF CONSTRUCTION, PRIOR TO BACKFILLING THE PIPE. THE CONTRACTOR IS INSTRUCTED TO AS-BUILT EACH SECTION OF STORM PIPE AS IT IS BEING INSTALLED TO ENSURE COMPLIANCE WITH THE DESIGN PLANS, AND AS APPROVED BY THE CITY OF CARMEL. LEGEND EXISTING FEATURES WATER MAIN SEWER, SANITARY SEWER, STORM CONTOUR WATER FLOWLINE NORMAL WATER ELEVATION FLOODWAY FRINGE (PRE-PUBLISHED FLOOD LINE) PROPOSED FEATURES WATER MAIN w/ HYDRANT SEWER, STORM CONTOUR NORMAL WATER ELEVATION WATER FLOWLINE 6" SUB-SURFACE DRAIN (UNDER SWALE) DENOTES FULL DEPTH GRANULAR BACKFILL DENOTES CONSTRUCTION LIMITS