Loading...
HomeMy WebLinkAboutC602-Subsurface Drain PlanD Y H E.T . U. P . U. P . U. P . U. P . RW RW U. P . U. P . 84 0 84 1 84 2 838 825 826 827 828 829 830 824 825 825 826 826 827 827 828 828 829 829 830 830 8 3 1 829829 LOT 2 LOT 1 C.A. #1 VAR. D.U.&B.M.P.E.&L.M.A.E. 10 ' D . & U . E . 10 ' D . & U . E . 10 ' D . & U . E . 10 ' D . & U . E . 10 ' D . & U . E . 10 ' D . & U . E . 25' D.&U.E. 25' D.&U.E. 75 ' R a d . 68.90' 1 2 R/W 68.90' 1 2 R/W 50 ' 10 ' T . P . E . 10' T.P.E. 84 6 84 5 844 842 35 ' B . L . 25' B.L. 25' B.L. 401 400 406 405 404403 402 407 409 BUFFER EASEMENT 50' FROM TOP OF BANK OF CARMEL CREEK VAR. WATER QUALITY PRESERVATION EASEMENT 15' Electrical & Telecomm. Easement Instr. No. 2019025955 & Instr. No. 2019031338 Approx. Limit of W.R. Fertig Open Regulated Drain (75' from Top of Bank) Approx. Top of Bank W.R. Fertig Open Regulated Drain Var. Width Drainage Access & Maintenance Easement Instr. No. 200300127290 20' Sewer Easement Instr. No. 8702420 15' Electrical & Telecomm. Easement Instr. No. 2019025955 & Instr. No. 2019031338 15' Electrical & Telecomm. Easement Instr. No. 2019025955 & Instr. No. 2019031338 South R/W 116th Street per INDOT Proj. No. STP-B886 (007) 408 VAR. WATER QUALITY PRESERVATION EASEMENT LOT 3 DONNYBROOK ADDITION Plat Book 2, Pages 233-234 Roland W. Slagle, III et al Inst. No. 2020079971 Lot 5Lot 4Lot 3Lot 2Lot 1 DONNYBROOK ADDITION Plat Book 2, Pages 233-234 MONON FARMS CONDOMINIUMS Plat Cabinet 3, Slide 651 Inst. No. 200500039345 Monon Farms Lane E. 1 1 6 t h S t r e e t TBM #2 TBM #1 10' T.P.E. 843 838 839 840 843 844 845 839 840 841 842 843 844 845 836 837 838 839 840 838 839 835 836 83 7 8 3 8 831 832 833 834 835 836 832 833 834 835 836 837 830831832833834835836837 832833834835836837838839840 837838839840841842843844 20' B.M.P.E. 10 ' D . & U . E . 10 ' D . & U . E . 50' T.P.E. 95 LF 6" SSD 100 LF 6" SSD 26 LF 6" SSD 100 LF 6" SSD 11 LF 6" SSD 137 LF 6" SSD 37 LF 6" SSD RISER TC:836.8 RISER TC:837.5 RISER TC:841.2 RISER TC:834.1 RISER TC:833.3RISER TC:826.2 DA T E MA R K RE V I S I O N S BY S & A JOB NO. SHEET NO. DRAWN BY:CHECKED BY: TH I S D R A W I N G I S N O T I N T E N D E D T O B E RE P R E S E N T E D A S A R E T R A C E M E N T O R OR I G I N A L B O U N D A R Y S U R V E Y , A R O U T E S U R V E Y O R A S U R V E Y O R LO C A T I O N R E P O R T . CE R T I F I E D : S T O E P P E L W E R T H A L W A Y S O N 79 6 5 E a s t 1 0 6 t h S t r e e t , F i s h e r s , I N 4 6 0 3 8 - 2 5 0 5 ph o n e : 3 1 7 . 8 4 9 . 5 9 3 5 f a x : 3 1 7 . 8 4 9 . 5 9 4 2 SU B - S U R F A C E D R A I N P L A N C602 111895GBC PDR BKR CL A Y T O W N S H I P HA M I L T O N C O U N T Y , I N D I A N A Fi l e N a m e : S: \ 1 1 1 8 9 5 G B C \ D W G \ C 6 0 2 - S u b s u r f a c e D r a i n P l a n . d w g - C6 0 2 Mo d i f i e d / B y : Ju n e 2 6 , 2 0 2 5 9 : 3 6 : 4 9 A M / pr i c h a r d s Pl o t t e d / B y : Ju n e 2 6 , 2 0 2 5 1 1 : 2 6 : 3 4 A M / Pa u l R i c h a r d s 06 / 2 6 / 2 5 SW I N L E Y F O R E S T 12 2 5 E A S T 1 1 6 t h S T R E E T GRAPHIC SCALE 0' ( IN FEET ) 30'15'30' 1" = 30' NOTES 1.THIS SURVEY REFLECTS ABOVE GROUND INDICATIONS OF UTILITIES AND INFORMATION AVAILABLE FROM UTILITY COMPANIES. THE SURVEYOR MAKES NO GUARANTEE THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. THE SURVEYOR FURTHER DOES NOT WARRANT THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED, ALTHOUGH HE DOES CERTIFY THAT THEY ARE LOCATED AS ACCURATELY AS POSSIBLE FROM THE INFORMATION AVAILABLE. THE SURVEYOR HAS NOT PHYSICALLY LOCATED THE UNDERGROUND UTILITIES. 2.CONTRACTOR SHALL VERIFY DEPTHS OF ALL EXISTING ONSITE UTILITIES PRIOR TO CONSTRUCTION TO CONFIRM THERE ARE NOT ANY CONFLICTS WITH OTHER UTILITIES, STORM SEWERS OR STREETS. CONFLICTS AFTER CONSTRUCTION BEGINS ARE SOLELY THE CONTRACTOR'S RESPONSIBILITY. 3.ALL STORM STRUCTURES TO RECEIVE SOLID LID CASTINGS ARE TO BE CONSTRUCTED TO PROVIDE ONE 4" RISER RING NO MORE, NO LESS TO ACHIEVE PLAN RIM GRADE. 4.ALL YARD INLETS ARE TO BE CONSTRUCTED AT A TOLERANCE OF +0.00' TO -0.20' OF PLAN GRADE. 5.ALL STORM SEWER CASTINGS SHALL BE LABELED "DUMP NO WASTE-DRAINS TO WATERWAY" 6.ALL SSD'S (SUBSURFACE DRAINS) WILL NEED TO BE DOUBLE WALL SMOOTH BORE PERFORATED (HDPE) PIPE. 7.DEBRIS GUARDS ARE TO BE INSTALLED ON ALL OPEN ENDED INLETS. 8.FOR STORM STRUCTURE SIZING AND CASTING TABLE SEE DETAIL D-18 ON SHEET C80X. 9.ALL STORM SEWERS WITHIN PUBLIC RIGHT-OF-WAY SHALL BE RCP CLASS III. 10.FOR INSTALLATION OF STORM UNDER CITY STREETS AND COVER REQUIREMENTS, SEE SHEET C80X ON THE TRENCH DETAIL. 11.ALL TOP OF CASTING ELEVATIONS FOR STORM SEWERS SHALL BE CONSTRUCTED WITH A TOLERANCE OF 0.10 FT±. 12.THE CITY OF CARMEL WILL NOT MAINTAIN CURBSIDE SSDs OR STORM SEWER IN PRIVATE ALLEYS. 13.SEE DESIGN DEVELOPMENT DOCUMENTS FOR SSD CONFIGURATIONS WITHIN BMPs. LEGEND EXISTING FEATURES SEWER, SANITARY SEWER, STORM WATER FLOWLINE NORMAL WATER ELEVATION FLOODWAY FRINGE (PRE-PUBLISHED FLOOD LINE) PROPOSED FEATURES WATER MAIN w/ HYDRANT SEWER, STORM CONTOUR WATER FLOWLINE 6" SUB-SURFACE DRAIN (UNDER SWALE) DENOTES CONSTRUCTION LIMITS BENCHMARK DATA ORIGINATING BENCHMARK: BENCHMARK ELEVATIONS FOR THIS PROJECT WERE DERIVED USING THE NATIONAL GEODETIC SURVEY ONLINE POSITIONING USER SERVICE (O.P.U.S) AND ARE REFERENCED TO THE NAVD '88 DATUM. SITE TBMs: TBM #1: A CUT SQUARE ON TOP OF THE CONCRETE CURB ON THE SOUTH SIDE OF 116th STREET, IMMEDIATELY EAST OF THE ENTRANCE TO THE GRAVEL DRIVE ON THE WEST SIDE OF THE SITE. EL: 832.38 (NAVD 88) TBM #2: A CUT "X" ON TOP OF THE CONCRETE TOP OF THE BRICK HEADWALL OVER CARMEL CREEK, AT THE NORTHWEST CORNER OF THE WALL. EL: 830.09 (NAVD 88)