Loading...
HomeMy WebLinkAboutC700-Water Main PlanD Y H E.T . U. P . U. P . 84 0 84 1 84 2 838 825 826 827 828 829 830 824 825 825 826 826 827 827 828 828 829 829 830 830 8 3 1 829829 LOT 4 LOT 2 LOT 1 C.A. #1 VAR. D.U.&B.M.P.E.&L.M.A.E. 10 ' D . & U . E . 10 ' D . & U . E . 10 ' D . & U . E . 10 ' D . & U . E . 10 ' D . & U . E . 10 ' D . & U . E . 25' D.&U.E. 25' D.&U.E.68.90' 1 2 R/W 68.90' 1 2 R/W 50' T.P.E. 10 ' T . P . E . 10' T.P.E. 849 848 847 847 846 845 844 843 84 6 84 5 844 842 35 ' B . L . 35 ' B . L . 25' B.L. 25' B.L. 60 ' I . E . E . & D . E . & U . E . 60 ' I . E . E . & D . E . & U . E . 18 ' 18 ' 12 0 ' BUFFER EASEMENT 50' FROM TOP OF BANK OF CARMEL CREEK VAR. WATER QUALITY PRESERVATION EASEMENT 15' Electrical & Telecomm. Easement Instr. No. 2019025955 & Instr. No. 2019031338 Approx. Limit of W.R. Fertig Open Regulated Drain (75' from Top of Bank) Var. Width Drainage Access & Maintenance Easement Instr. No. 200300127290 20' Sewer Easement Instr. No. 8702420 15' Electrical & Telecomm. Easement Instr. No. 2019025955 & Instr. No. 2019031338 15' Electrical & Telecomm. Easement Instr. No. 2019025955 & Instr. No. 2019031338 South R/W 116th Street per INDOT Proj. No. STP-B886 (007) 10' T.P.E. VAR. WATER QUALITY PRESERVATION EASEMENT LOT 3 MONON FARMS CONDOMINIUMS Plat Cabinet 3, Slide 651 Inst. No. 200500039345 MONON FARMS CONDOMINIUMS Plat Cabinet 3, Slide 651 Inst. No. 200500039345 Monon Farms Lane E. 1 1 6 t h S t r e e t 20' 10' T.P.E.20' R 20'R 843 838 839 840 843 844 845 839 840 841 842 843 844 845 836 837 838 839 840 838 839 835 836 83 7 8 3 8 831 832 833 834 835 836 832 833 834 835 836 837 830831832833834835836837 832833834835836837838839840 837838839840841842843844 20' B.M.P.E. 10 ' D . & U . E . 10 ' D . & U . E . 50' T.P.E. 8" VALVE 45° BEND 45 ° B E N D HY D R A N T w/ V A L V E HY D R A N T w/ V A L V E 8" T A P P I N G T E E 54" DEPTH CROSSING 68" DEPTH CROSSING ±38 LF 1" COPPER WATER SERVICE ±38 LF 1" COPPER WATER SERVICE ±38 LF 1" COPPER WATER SERVICE ±48 LF 1" COPPER WATER SERVICE CONNECT TO EX. 8" WATER MAIN (Private) DRIVE DA T E MA R K RE V I S I O N S BY S & A JOB NO. SHEET NO. DRAWN BY:CHECKED BY: TH I S D R A W I N G I S N O T I N T E N D E D T O B E RE P R E S E N T E D A S A R E T R A C E M E N T O R OR I G I N A L B O U N D A R Y S U R V E Y , A R O U T E S U R V E Y O R A S U R V E Y O R LO C A T I O N R E P O R T . CE R T I F I E D : S T O E P P E L W E R T H A L W A Y S O N 79 6 5 E a s t 1 0 6 t h S t r e e t , F i s h e r s , I N 4 6 0 3 8 - 2 5 0 5 ph o n e : 3 1 7 . 8 4 9 . 5 9 3 5 f a x : 3 1 7 . 8 4 9 . 5 9 4 2 WA T E R M A I N P L A N C700 111895GBC PDR BKR CL A Y T O W N S H I P HA M I L T O N C O U N T Y , I N D I A N A Fi l e N a m e : S: \ 1 1 1 8 9 5 G B C \ D W G \ C 7 0 0 - W a t e r M a i n P l a n . d w g - C7 0 0 Mo d i f i e d / B y : Ju n e 2 6 , 2 0 2 5 9 : 4 6 : 3 6 A M / pr i c h a r d s Pl o t t e d / B y : Ju n e 2 6 , 2 0 2 5 1 1 : 2 6 : 4 2 A M / Pa u l R i c h a r d s 06 / 2 6 / 2 5 SW I N L E Y F O R E S T 12 2 5 E A S T 1 1 6 t h S T R E E T GRAPHIC SCALE 0' ( IN FEET ) 30'15'30' 1" = 30' BENCHMARK DATA ORIGINATING BENCHMARK: BENCHMARK ELEVATIONS FOR THIS PROJECT WERE DERIVED USING THE NATIONAL GEODETIC SURVEY ONLINE POSITIONING USER SERVICE (O.P.U.S) AND ARE REFERENCED TO THE NAVD '88 DATUM. SITE TBMs: TBM #1: A CUT SQUARE ON TOP OF THE CONCRETE CURB ON THE SOUTH SIDE OF 116th STREET, IMMEDIATELY EAST OF THE ENTRANCE TO THE GRAVEL DRIVE ON THE WEST SIDE OF THE SITE. EL: 832.38 (NAVD 88) TBM #2: A CUT "X" ON TOP OF THE CONCRETE TOP OF THE BRICK HEADWALL OVER CARMEL CREEK, AT THE NORTHWEST CORNER OF THE WALL. EL: 830.09 (NAVD 88) NOTES 1.THIS SURVEY REFLECTS ABOVE GROUND INDICATIONS OF UTILITIES AND INFORMATION AVAILABLE FROM UTILITY COMPANIES. THE SURVEYOR MAKES NO GUARANTEE THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. THE SURVEYOR FURTHER DOES NOT WARRANT THAT THE UNDERGROUND UTILITIES SHOWN ARE IN THE EXACT LOCATION INDICATED, ALTHOUGH HE DOES CERTIFY THAT THEY ARE LOCATED AS ACCURATELY AS POSSIBLE FROM THE INFORMATION AVAILABLE. THE SURVEYOR HAS NOT PHYSICALLY LOCATED THE UNDERGROUND UTILITIES. 2.CONTRACTOR SHALL VERIFY DEPTHS OF ALL EXISTING ONSITE UTILITIES PRIOR TO CONSTRUCTION TO CONFIRM THERE ARE NOT ANY CONFLICTS WITH OTHER UTILITIES, STORM SEWERS OR STREETS. CONFLICTS AFTER CONSTRUCTION BEGINS ARE SOLELY THE CONTRACTOR'S RESPONSIBILITY. 3.NO EARTH DISTURBING ACTIVITIES MAY TAKE PLACE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. 4.FOR INSTALLATION OF SANITARY AND WATER UNDER CITY STREETS AND COVER REQUIREMENTS, SEE THE TRENCH DETAIL ON SHEET C800. 5.ALL WATER MAIN SERVICE LINES TO TERMINATE 5 FEET BEHIND SIDEWALK AND MARKED WITH A 4" PVC PIPE WITH A PAINTED BLUE TOP. 6.POSI-CAPS OR EQUIVALENT ARE REQUIRED ON ALL WATER VALVE INSTALLATIONS AND MEGA LUGS MUST BE INSTALLED AT ALL MECHANICAL JOINTS. 7.ALL DUCTILE IRON WATER MAINS SHALL BE BEDDED IN SAND FROM THE BOTTOM OF THE TRENCH TO 12" ABOVE THE PIPE. 8.INSTALL WATER MAIN TRACER WIRE WITH ALL WATER MAINS LAID AND BLUE REFLECTOR TAPE MUST BE INSTALLED 12" TO 18" ABOVE ALL WATER MAINS LAID. 9.ALL WATER MAINS SHALL BE DUCTILE IRON AND INSTALLED PER THE CITY OF CARMEL SPECIFICATIONS. 10.FULL DEPTH GRANULAR BACKFILL PER CITY STANDARDS SHALL BE PLACED FOR ALL STREET CROSSINGS. 11.FIRE HYDRANT MARKERS TO BE INSTALLED IN THE STREET PAVEMENT PERPENDICULAR TO THE FIRE HYDRANT. 12.ONLY MUELLER HYDRANTS AND VALVES MAY BE USED. 13.SECTION 33121 FIRE HYDRANTS SHALL BE FULLY FUNCTIONAL TESTED AND APPROVED BY CARMEL WATER UTILITIES PRIOR TO ANY COMBUSTIBLE MATERIALS ARRIVING ON THE SITE. 14.SECTION 3310.1 REQUIRED FIRE DEPARTMENT VEHICLE ACCESS. APPROVED ASPHALT FIRE APPARATUS ACCESS ROADS SHALL BE PROVIDED TO AND THROUGH THE CONSTRUCTION SITE DURING CONSTRUCTION. FIRE APPARATUS ACCESS ROADS MUST BE CAPABLE OF SUPPORTING THE WEIGHT OF FIRE APPARATUS AND MAINTAINED CLEAR AT ALL TIMES. LEGEND EXISTING FEATURES WATER MAIN SEWER, SANITARY SEWER, STORM WATER, HYDRANT WATER, VALVE PROPOSED FEATURES WATER MAIN SEWER, STORM HYDRANT w/ 6" VALVE FITTING, TEE FITTING, HORIZONTAL BEND HYDRANT PAVEMENT MARKER DENOTES CONSTRUCTION LIMITS