STAIR-1
S-01
CONF. RM.
003
STO. RM.
001
SERVER ROOM
002
WOMEN'S C.R.
019
BLUE SKY RM.
005
OFFICE
006
OFFICE
007
OFFICE
008
OFFICE
009 OFFICE
010 OFFICE
011
WORK
STATIONS
015 WORK RM.
016
WAIT/LOBBY
014
RECE.
013
GREEN ROOM
021
VIDEO
CONTROL
022
MECH. ROOM
020
FIRE PUMP
ROOM
034
TRAP ROOM
033 AUDIO
CONTROL
026
VIDEO EDIT
027
RECORDING
STUDIO
029
DRUM
031
VOICE
030
VESTIBULE
C008
OFFICE
004
CORR.
C-001
C.R. WAITING
AREA
017
MEN'S C.R.
018
GREEN RM.
ENTRY
021A
CORR.
C-007
CORR.
C-005
VEST.
025
CORR.
C-009
STAIR-3
S-03
3.1
NUMBER OF CALCULATED OCCUPANTS
PATH OF EGRESS
RECESSED FEC
HANDICAPPED ENTRY
1 HOUR RATED WALL
2 HOUR RATED WALL
APPLIED FIREPROOFING MATERIAL ON STEEL STRUCTURE IN
SHADED AREA
UL#X772 (1 HR. FIRE RATING FOR WIDE FLANGE COLUMNS)
UL#X771 (1 HR. FIRE RATING FOR TUBE COLUMNS)
UL#N782 (1 HR. FIRE RATING FOR BEAMS & MISC. STEEL)
100
BD
C2 CB
1 3 5
H3
2.3 4
X9
X2
X3
X6
X7
X8
H2
4.6
H4
P
4.3
H5
4.8
M
L
C
L4
Q
S
ND
U
H1.5
1.5
H3.2
X
2.0
3.8
H1
0.8 2.6 3.6
Y2
G
Z
L2
L3
P12
P15
X10
X4
X5
X1
0.4 2.4 2.8 3.3 4.4
Y
E F
B
Z2
Z3
Z1
Z4
P4 P5
P3
P2
P6 P7
P10
N1
N2
N3
M1
M2
M3
N
1.3 2.1
W
W3
W2
W1
P8
P9
2.2 4.2
N4
4.1
P1
T4
T1
T2
T3
T5
S1
S2
S3
S4
S5
WORKSHOP
116
STORAGE
115
SIDE
PLATFORM
117
DELIVERY
118
STAIR-1
S-11
CHAIR
STORAGE/
CATERING
105
VEST.
107
CORR.
C-101
SOUND BOOTH
104
VESTIBULE
102
VEST.
112
VEST.
113
VESTIBULE
106
J
J1
J2
1 (1100)
6 (2) 4 (97)
5 (2)
4 (162)
2 (325) 2 (525)
3 (96)
2 (346)
6 (2)
5 (3) 2 (105)
7 (1)
6 (3)
7 (7)
4 (284)
7 (1)
TWO HOUR SEPARATION
BETWEEN EXISTING ASSEMBLY
USE AND NEW A-3 ASSEMBLY USE
PLATFORM
119
LEVEL-1
103
3.1
6/12/2008 4:30:15 PM
Date: Scale
Drawn By
Checked By
Project
Number
ARCHITECTURE
PLANNING
INTERIOR DESIGN
STRUCTURAL ENGINEERING
424 East Fourth Street
Cincinnati, Ohio 45202
w w w . c h a r c h i t e c t s . c o m
tel: 513/241/4474 fax: 513/241/0081
ISSUANCES
COMPUTER FILE
1400 West Dorothy Lane
Dayton, Ohio 45409-1310
Tel: (937) 224-0861
Fax: (937) 224-5777
3417 South Sherman Drive
Beech Grove, IN 46107
Tel: (317) 780-1555
Fax: (317) 780-6525
750 North Orleans, Suite 400
Chicago, IL 60610
Tel: (312) 944-8230
Fax: (312) 944-8297
117 East Washington
Street, Suite 200
Indianapolis, IN 46204
Tel: (317) 637-2222
Fax: (317) 637-2260
1137 West Taylor St.
Suite 316
Chicago, IL 60607
Tel: (312) 224-8460
Fax: (312) 224-8961
1025 N.Watery Ln.
Brigham City, UT 84302
TEL: (453) 723-5000
FAX: (453) 538-5506
6622 Kingspointe
Parkway
Orlando, FL 33819
Tel: (407) 816-9400
Fax: (407) 816-9300
900145
E
T
T
E
L
C
O
T
T
A
B
J
.
M
.
A
R
C
H
I
T
E
C
T
. .
NO
STATE OF
I
N
D
I
A
N
A
D
E
R
E
T
S
I
G
E
R
No. Description Date
As indicated
6/12/2008 4:30:19 PM
C:\!!!Bryan\Revit\NVCLC-bd.rvt
A001
LIFE SAFETY PIT
LEVEL AND MAIN
LEVEL
NEW WORSHIP
CENTER
Checker
Author
06-10-2008
535-3581
A. APPLICABLE CODES
1. INDIANA BUILDING CODE - 2003 (REFERENCES IBC 2000)
B. BUILDING CLASSIFICATIONS
1. USE GROUP: (IBC 303.1) - ASSEMBLY GROUP, A-3
2. SEPARATION OF OCCUPANCIES: (IBC T302.3.3) - 2 HOURS BETWEEN NEW A-3, ASSEMBLY AND EXISTING A-3, ASSEMBLY
3. CONSTRUCTION CLASSIFICATION: (IBC 603) - 2B, NON-COMBUSTIBLE, UNPROTECTED
C. HEIGHT AND AREA LIMITATIONS
1. ALLOWABLE HEIGHT: (IBC T503) - 2 STORIES/55'-0"
2. HEIGHT MODIFICATIONS: (IBC 504.2) - +2 STORIES/55'-0"
+1 STORY/20'-0" (WITH AUTOMATIC SPRINKLERS)
+3 STORIES/75'-0"
3. ALLOWABLE AREA: (IBC T503) - 9,500 GSF/STORY
4. AREA MODIFICATIONS (IBC 506) - +9,500 GSF ALLOWABLE AREA
+23,000 GSF (WITH AUTOMATIC SPRINKLERS)
+46,000 GSF/STORY
5. a. ACTUAL HEIGHT: 2 STORIES/65'-4"
b. ACTUAL GSF: 25,600 SF MAIN LEVEL/ 13,200 SF PIT LEVEL
D. FIRE RESISTANT RATINGS
1. STRUCTURAL FRAMING INCLUDING COLUMNS, GIRDERS, TRUSSES
SUPPORTING MORE THAN 1 FLOOR - 0 HR. (T601)
SUPPORTING ROOF ONLY - 0 HR. (T601)
2. EXTERIOR WALLS (LOADBEARING) - 0 HR. (T601)
(NONLOADBEARING) - 0 HR. (T601)
3. INTERIOR WALLS (LOADBEARING) - 0 HR. (T601)
(NONLOADBEARING) - 0 HR. (T601)
4. FLOORS - 0 HR. (T601)
5. ROOF - 0 HR. (T601)
6. SHAFTS/ELEVATOR HOISTWAY - 1 HR.< 4 STORIES (707.4)
(INCLUDING STRUCTURE)
UL NUMBERS FOR APPLIED FIREPROOFING
UL#X772 (1 HR. FIRE RATING FOR WIDE FLANGE COLUMNS)
UL#X771 (1 HR. FIRE RATING FOR TUBE COLUMNS)
UL#N782 (1 HR. FIRE RATING FOR BEAMS & MISC. STEEL)
- CLOSE OFF BOTTOM OF SHAFTS TO MAINTAIN SAME RATING AS WALLS
AND SUPPORTING STRUCTURE
7. CORRIDORS - 0 HR. (T1004.3.2.1)
8. EXIT PASSAGEWAY - 1 HR. (1005.3.3.2)
9. PERIMETER FIRE SEPARATION - 10" GAP MAXIMUM, UL #CW-D-2001
- 2.5" GAP MAXIMUM, UL #CW-S-1001
CALCULATION OF OCCUPANT LOAD DETERMINED PER OBC 1003.2.2.2 (THE NUMBER IN "()" IDENTIFIES THE NUMBER OF OCCUPANTS):
ACTUAL FIXED SEATING LAYOUT
ROOM AREA (NET S.F.) DIVIDED BY 5 (ASSEMBLY STANDING)
ROOM AREA (NET S.F.) DIVIDED BY 7 (ASSEMBLY CHAIRS)
ROOM AREA (NET S.F.) DIVIDED BY 15 (ASSEMBLY WITH TABLES AND CHAIRS AND STAGES/PLATFORM AREAS)
ROOM AREA (GROSS S.F.) DIVIDED BY 100 (BUSINESS AREA)
ROOM AREA (GROSS S.F.) DIVIDED BY 200 (KITCHEN)
ROOM AREA (GROSS S.F.) DIVIDED BY 300 (STORAGE AREA/MECHANICAL AREA)
A001 1/16" = 1'-0"
2 LIFE SAFETY LEVEL-0 PIT LEVEL
1
2
3
4
5
6
7
E. MEANS OF EGRESS
1. OCCUPANT LOAD:
PIT LEVEL - 110 OCCUPANTS (IBC T1003.2.2.2)
MAIN LEVEL - 3,061 OCCUPANTS (IBC T1003.2.2.2)
FIRST BALCONY - 543 OCCUPANTS (IBC T1003.2.2.2)
SECOND BALCONY - 400 OCCUPANTS (IBC T1003.2.2.2)
TOTAL - 4,114 OCCUPANTS
2. CAPACITY OF COMPONENTS:
a. NUMBER OF PEOPLE PER STAIR: 543 PEOPLE (FIRST BALCONY OCCUPANTS)/ 3 STAIRS = 181 PEOPLE / STAIR
b. REQUIRED WIDTH OF STAIR (44" MIN REQUIRED - IBC 1003.3.3.1): .2" x 181 (FIRST BALCONY OCCUPANTS) = 37"
c. REQUIRED WIDTH OF DOORS (32" MIN REQUIRED - IBC 1003.3.1.1):
.15" x 1,396 (NEW WORSHIP CENTER OCCUPANTS) = 210" (16 DOORS X 36" WIDE = 576" OUT OF WORSHIP CENTER)
.15" x 1,665 (EXISTING SANCTUARY OCCUPANTS) = 250"
.15" x 4,114 (TOTAL MAIN LEVEL OCCUPANTS) = 618" (19 DOORS X 36" WIDE = 684" OUT OF BUILDING)
3. LENGTH OF EXIT ACCESS TRAVEL: 250 L.F.. (IBC T1004.2.4) - FULLY SPRINKLERED
4. COMMON PATH OF TRAVEL: 75'-0" MAX. (IBC 1004.2.5) - FULLY SPRINKLERED
5. DEAD END LENGTH: 20'-0" MAX. (IBC 1004.3.2.3) - FULLY SPRINKLERED
F. PLUMBING FIXTURES REQUIREMENTS (IBC T2902.1)
1. OCCUPANT LOAD (NEW WORSHIP CENTER & EXISTING MAIN LEVEL):
2,057 MALE OCCUPANTS
2,057 FEMALE OCCUPANTS
1. WATER CLOSETS:
2,057/150 = 14 WATER CLOSETS, MALE (14 WATER CLOSETS PROVIDED)
2,057/75 = 28 WATER CLOSETS, FEMALE (28 WATER CLOSETS PROVIDED)
2. LAVATORIES:
4,114/200 = 21 LAVATORIES (28 LAVATORIES PROVIDED)
3. DRINKING FOUNTAINS:
4,114/1000 = 5 DRINKING FOUNTAINS (6 DRINKING FOUNTAINS PROVIDED)
4 PERMIT SET 04.25.08
A001 1/16" = 1'-0"
1 LIFE SAFETY LEVEL-1 MAIN LEVEL
5 ADDENDUM #2 05.16.08
6 ADDENDUM #3 05.23.08
10 PERMIT SET 06.10.08