HomeMy WebLinkAboutA001UP UP UP F.E.C. F.E.C. F.E.C. DN UP F.E.C. DN DN DN UP UP UP DN UP DN DN UP F.E.C. F.E.C. F.E.C. F.E.C. F.E.C. DN F.E.C. DN UP DN 1 3 5 H3 2.3 4 X9 X2 X3 X6 X7 X8 H2 4.6 4.6 M ND H1.5 1.5 1.5 H3.2 X 2.0 3.8 H1 0.8 2.6 3.6 Y2 G X10 X4 X5 X1 0.4 2.4 2.8 3.3 4.4 Y E F P9 4.1 J J1 J2 7 (12) 5 (98) STAIR-1 S-01 CONF. RM. 003 STO. RM. 001 SERVER ROOM 002 WOMEN'S C.R. 019 BLUE SKY RM. 005 OFFICE 006 OFFICE 007 OFFICE 008 OFFICE 009 OFFICE 010 OFFICE 011 WORK STATIONS 015 WORK RM. 016 WAIT/LOBBY 014 RECE. 013 GREEN ROOM 021 VIDEO CONTROL 022 MECH. ROOM 020 FIRE PUMP ROOM 034 TRAP ROOM 033 AUDIO CONTROL 026 VIDEO EDIT 027 RECORDING STUDIO 029 DRUM 031 VOICE 030 VESTIBULE C008 OFFICE 004 CORR. C-001 C.R. WAITING AREA 017 MEN'S C.R. 018 GREEN RM. ENTRY 021A CORR. C-007 CORR. C-005 VEST. 025 CORR. C-009 STAIR-3 S-03 3.1 NUMBER OF CALCULATED OCCUPANTS PATH OF EGRESS RECESSED FEC HANDICAPPED ENTRY 1 HOUR RATED WALL 2 HOUR RATED WALL APPLIED FIREPROOFING MATERIAL ON STEEL STRUCTURE IN SHADED AREA UL#X772 (1 HR. FIRE RATING FOR WIDE FLANGE COLUMNS) UL#X771 (1 HR. FIRE RATING FOR TUBE COLUMNS) UL#N782 (1 HR. FIRE RATING FOR BEAMS & MISC. STEEL) 100 BD C2 CB 1 3 5 H3 2.3 4 X9 X2 X3 X6 X7 X8 H2 4.6 H4 P 4.3 H5 4.8 M L C L4 Q S ND U H1.5 1.5 H3.2 X 2.0 3.8 H1 0.8 2.6 3.6 Y2 G Z L2 L3 P12 P15 X10 X4 X5 X1 0.4 2.4 2.8 3.3 4.4 Y E F B Z2 Z3 Z1 Z4 P4 P5 P3 P2 P6 P7 P10 N1 N2 N3 M1 M2 M3 N 1.3 2.1 W W3 W2 W1 P8 P9 2.2 4.2 N4 4.1 P1 T4 T1 T2 T3 T5 S1 S2 S3 S4 S5 WORKSHOP 116 STORAGE 115 SIDE PLATFORM 117 DELIVERY 118 STAIR-1 S-11 CHAIR STORAGE/ CATERING 105 VEST. 107 CORR. C-101 SOUND BOOTH 104 VESTIBULE 102 VEST. 112 VEST. 113 VESTIBULE 106 J J1 J2 1 (1100) 6 (2) 4 (97) 5 (2) 4 (162) 2 (325) 2 (525) 3 (96) 2 (346) 6 (2) 5 (3) 2 (105) 7 (1) 6 (3) 7 (7) 4 (284) 7 (1) TWO HOUR SEPARATION BETWEEN EXISTING ASSEMBLY USE AND NEW A-3 ASSEMBLY USE PLATFORM 119 LEVEL-1 103 3.1 6/12/2008 4:30:15 PM Date: Scale Drawn By Checked By Project Number ARCHITECTURE PLANNING INTERIOR DESIGN STRUCTURAL ENGINEERING 424 East Fourth Street Cincinnati, Ohio 45202 w w w . c h a r c h i t e c t s . c o m tel: 513/241/4474 fax: 513/241/0081 ISSUANCES COMPUTER FILE 1400 West Dorothy Lane Dayton, Ohio 45409-1310 Tel: (937) 224-0861 Fax: (937) 224-5777 3417 South Sherman Drive Beech Grove, IN 46107 Tel: (317) 780-1555 Fax: (317) 780-6525 750 North Orleans, Suite 400 Chicago, IL 60610 Tel: (312) 944-8230 Fax: (312) 944-8297 117 East Washington Street, Suite 200 Indianapolis, IN 46204 Tel: (317) 637-2222 Fax: (317) 637-2260 1137 West Taylor St. Suite 316 Chicago, IL 60607 Tel: (312) 224-8460 Fax: (312) 224-8961 1025 N.Watery Ln. Brigham City, UT 84302 TEL: (453) 723-5000 FAX: (453) 538-5506 6622 Kingspointe Parkway Orlando, FL 33819 Tel: (407) 816-9400 Fax: (407) 816-9300 900145 E T T E L C O T T A B J . M . A R C H I T E C T . . NO STATE OF I N D I A N A D E R E T S I G E R No. Description Date As indicated 6/12/2008 4:30:19 PM C:\!!!Bryan\Revit\NVCLC-bd.rvt A001 LIFE SAFETY PIT LEVEL AND MAIN LEVEL NEW WORSHIP CENTER Checker Author 06-10-2008 535-3581 A. APPLICABLE CODES 1. INDIANA BUILDING CODE - 2003 (REFERENCES IBC 2000) B. BUILDING CLASSIFICATIONS 1. USE GROUP: (IBC 303.1) - ASSEMBLY GROUP, A-3 2. SEPARATION OF OCCUPANCIES: (IBC T302.3.3) - 2 HOURS BETWEEN NEW A-3, ASSEMBLY AND EXISTING A-3, ASSEMBLY 3. CONSTRUCTION CLASSIFICATION: (IBC 603) - 2B, NON-COMBUSTIBLE, UNPROTECTED C. HEIGHT AND AREA LIMITATIONS 1. ALLOWABLE HEIGHT: (IBC T503) - 2 STORIES/55'-0" 2. HEIGHT MODIFICATIONS: (IBC 504.2) - +2 STORIES/55'-0" +1 STORY/20'-0" (WITH AUTOMATIC SPRINKLERS) +3 STORIES/75'-0" 3. ALLOWABLE AREA: (IBC T503) - 9,500 GSF/STORY 4. AREA MODIFICATIONS (IBC 506) - +9,500 GSF ALLOWABLE AREA +23,000 GSF (WITH AUTOMATIC SPRINKLERS) +46,000 GSF/STORY 5. a. ACTUAL HEIGHT: 2 STORIES/65'-4" b. ACTUAL GSF: 25,600 SF MAIN LEVEL/ 13,200 SF PIT LEVEL D. FIRE RESISTANT RATINGS 1. STRUCTURAL FRAMING INCLUDING COLUMNS, GIRDERS, TRUSSES SUPPORTING MORE THAN 1 FLOOR - 0 HR. (T601) SUPPORTING ROOF ONLY - 0 HR. (T601) 2. EXTERIOR WALLS (LOADBEARING) - 0 HR. (T601) (NONLOADBEARING) - 0 HR. (T601) 3. INTERIOR WALLS (LOADBEARING) - 0 HR. (T601) (NONLOADBEARING) - 0 HR. (T601) 4. FLOORS - 0 HR. (T601) 5. ROOF - 0 HR. (T601) 6. SHAFTS/ELEVATOR HOISTWAY - 1 HR.< 4 STORIES (707.4) (INCLUDING STRUCTURE) UL NUMBERS FOR APPLIED FIREPROOFING UL#X772 (1 HR. FIRE RATING FOR WIDE FLANGE COLUMNS) UL#X771 (1 HR. FIRE RATING FOR TUBE COLUMNS) UL#N782 (1 HR. FIRE RATING FOR BEAMS & MISC. STEEL) - CLOSE OFF BOTTOM OF SHAFTS TO MAINTAIN SAME RATING AS WALLS AND SUPPORTING STRUCTURE 7. CORRIDORS - 0 HR. (T1004.3.2.1) 8. EXIT PASSAGEWAY - 1 HR. (1005.3.3.2) 9. PERIMETER FIRE SEPARATION - 10" GAP MAXIMUM, UL #CW-D-2001 - 2.5" GAP MAXIMUM, UL #CW-S-1001 CALCULATION OF OCCUPANT LOAD DETERMINED PER OBC 1003.2.2.2 (THE NUMBER IN "()" IDENTIFIES THE NUMBER OF OCCUPANTS): ACTUAL FIXED SEATING LAYOUT ROOM AREA (NET S.F.) DIVIDED BY 5 (ASSEMBLY STANDING) ROOM AREA (NET S.F.) DIVIDED BY 7 (ASSEMBLY CHAIRS) ROOM AREA (NET S.F.) DIVIDED BY 15 (ASSEMBLY WITH TABLES AND CHAIRS AND STAGES/PLATFORM AREAS) ROOM AREA (GROSS S.F.) DIVIDED BY 100 (BUSINESS AREA) ROOM AREA (GROSS S.F.) DIVIDED BY 200 (KITCHEN) ROOM AREA (GROSS S.F.) DIVIDED BY 300 (STORAGE AREA/MECHANICAL AREA) A001 1/16" = 1'-0" 2 LIFE SAFETY LEVEL-0 PIT LEVEL 1 2 3 4 5 6 7 E. MEANS OF EGRESS 1. OCCUPANT LOAD: PIT LEVEL - 110 OCCUPANTS (IBC T1003.2.2.2) MAIN LEVEL - 3,061 OCCUPANTS (IBC T1003.2.2.2) FIRST BALCONY - 543 OCCUPANTS (IBC T1003.2.2.2) SECOND BALCONY - 400 OCCUPANTS (IBC T1003.2.2.2) TOTAL - 4,114 OCCUPANTS 2. CAPACITY OF COMPONENTS: a. NUMBER OF PEOPLE PER STAIR: 543 PEOPLE (FIRST BALCONY OCCUPANTS)/ 3 STAIRS = 181 PEOPLE / STAIR b. REQUIRED WIDTH OF STAIR (44" MIN REQUIRED - IBC 1003.3.3.1): .2" x 181 (FIRST BALCONY OCCUPANTS) = 37" c. REQUIRED WIDTH OF DOORS (32" MIN REQUIRED - IBC 1003.3.1.1): .15" x 1,396 (NEW WORSHIP CENTER OCCUPANTS) = 210" (16 DOORS X 36" WIDE = 576" OUT OF WORSHIP CENTER) .15" x 1,665 (EXISTING SANCTUARY OCCUPANTS) = 250" .15" x 4,114 (TOTAL MAIN LEVEL OCCUPANTS) = 618" (19 DOORS X 36" WIDE = 684" OUT OF BUILDING) 3. LENGTH OF EXIT ACCESS TRAVEL: 250 L.F.. (IBC T1004.2.4) - FULLY SPRINKLERED 4. COMMON PATH OF TRAVEL: 75'-0" MAX. (IBC 1004.2.5) - FULLY SPRINKLERED 5. DEAD END LENGTH: 20'-0" MAX. (IBC 1004.3.2.3) - FULLY SPRINKLERED F. PLUMBING FIXTURES REQUIREMENTS (IBC T2902.1) 1. OCCUPANT LOAD (NEW WORSHIP CENTER & EXISTING MAIN LEVEL): 2,057 MALE OCCUPANTS 2,057 FEMALE OCCUPANTS 1. WATER CLOSETS: 2,057/150 = 14 WATER CLOSETS, MALE (14 WATER CLOSETS PROVIDED) 2,057/75 = 28 WATER CLOSETS, FEMALE (28 WATER CLOSETS PROVIDED) 2. LAVATORIES: 4,114/200 = 21 LAVATORIES (28 LAVATORIES PROVIDED) 3. DRINKING FOUNTAINS: 4,114/1000 = 5 DRINKING FOUNTAINS (6 DRINKING FOUNTAINS PROVIDED) 4 PERMIT SET 04.25.08 A001 1/16" = 1'-0" 1 LIFE SAFETY LEVEL-1 MAIN LEVEL 5 ADDENDUM #2 05.16.08 6 ADDENDUM #3 05.23.08 10 PERMIT SET 06.10.08