HomeMy WebLinkAboutA002DN
UP
DN
UP
DN
DN
UP DN
DN
UP
F.E.C.
F.E.C.
F.E.C.
F.E.C.
F.E.C.
F.E.C.
DN
F.E.C.
UP
F.E.C.
F.E.C.
DN
F.E.C.
DN
UP
DN
DN
DN DN
F.E.C.
F.E.C.
DN
DN
UP
DN
DN DN
F.E.C.
1 3 5
H3
2.3 4
X9
X2
X3
X6
X7
X8
H2
4.6
H4
P
H5
L
L
C
L4
S
T
ND
U
H1.5
1.5
H3.2
X
2.0
3.8
H1
2.6 3.6
3.6
0.8
Y2
G
Z
L2
L3
P12
P15
X10
X4
X5
X1
0.4 2.4 2.8 3.3 4.4
Y
E F
B
Z2
Z3
Z1
Z4
P4 P5
P3
P2
P6 P7
P10
2.1
W
W3
W2
W1
P8
P9
2.2
4.2
4.1
T4
T1
T2
T3
T5
S1
S2
S3
S4
S5
MEZZANINE
204
CRYING ROOM
202
MACHINE RM.
203
VEST.
201
BALCONY-1
200
STAIR-3
S-23
STAIR-4
S-24
J
J1
J2
1 (530)
7 (1)
4 (12)
3.1
NUMBER OF CALCULATED OCCUPANTS
PATH OF EGRESS
RECESSED FEC
HANDICAPPED ENTRY
1 HOUR RATED WALL
2 HOUR RATED WALL
APPLIED FIREPROOFING MATERIAL ON STEEL STRUCTURE IN
SHADED AREA
UL#X772 (1 HR. FIRE RATING FOR WIDE FLANGE COLUMNS)
UL#X771 (1 HR. FIRE RATING FOR TUBE COLUMNS)
UL#N782 (1 HR. FIRE RATING FOR BEAMS & MISC. STEEL)
100
1 3 5
H3
4
4
2.3
2.3
H2
4.6
H4
P
H5
L
L4
S
H1.5
1.5 2.0
H1
0.8
Y2
G
L2
L3
P12
P15
0.4 2.4 3.3 4.4
Y
E F
B
P4 P5
P3
P2
P6 P7
P10
W
W3
W2
W1
P8
P9
4.1
T4
T1
T2
T3
T5
S1
S2
S3
S4
S5
SECOND
BALCONY
300
STAIR-4
S-34
STAIR-3
S-33
J
J1
J2
1 (400)
ELEVATOR
VEST.
301
3.1
1 2.3 3 4 5
H2
4.6
P
L
L4
S
T
U
1.5
X
2.0
H1
0.8 2.6 3.6
Y2
L2
L3
P12
P15
0.4 2.4 2.8 3.3 4.4
Y
E F
B
P4 P5
P3
P2
P6 P7
P10
2.1
W
W3
W2
W1
P8
P9
2.2
P1
T4
T1
T2
T3
T5
S1
S2
S3
S4
S5
J
J1
J2
ELEV. VEST.
401
3.1
6/12/2008 4:31:39 PM
Date: Scale
Drawn By
Checked By
Project
Number
ARCHITECTURE
PLANNING
INTERIOR DESIGN
STRUCTURAL ENGINEERING
424 East Fourth Street
Cincinnati, Ohio 45202
w w w . c h a r c h i t e c t s . c o m
tel: 513/241/4474 fax: 513/241/0081
ISSUANCES
COMPUTER FILE
1400 West Dorothy Lane
Dayton, Ohio 45409-1310
Tel: (937) 224-0861
Fax: (937) 224-5777
3417 South Sherman Drive
Beech Grove, IN 46107
Tel: (317) 780-1555
Fax: (317) 780-6525
750 North Orleans, Suite 400
Chicago, IL 60610
Tel: (312) 944-8230
Fax: (312) 944-8297
117 East Washington
Street, Suite 200
Indianapolis, IN 46204
Tel: (317) 637-2222
Fax: (317) 637-2260
1137 West Taylor St.
Suite 316
Chicago, IL 60607
Tel: (312) 224-8460
Fax: (312) 224-8961
1025 N.Watery Ln.
Brigham City, UT 84302
TEL: (453) 723-5000
FAX: (453) 538-5506
6622 Kingspointe
Parkway
Orlando, FL 33819
Tel: (407) 816-9400
Fax: (407) 816-9300
900145
E
T
T
E
L
C
O
T
T
A
B
J
.
M
.
A
R
C
H
I
T
E
C
T
. .
NO
STATE OF
I
N
D
I
A
N
A
D
E
R
E
T
S
I
G
E
R
No. Description Date
As indicated
6/12/2008 4:31:42 PM
C:\!!!Bryan\Revit\NVCLC-bd.rvt
A002
LIFE SAFETY FIRST
BALCONY, SECOND
BALCONY AND
CATWALK
NEW WORSHIP
CENTER
Checker
KJ
06-10-2008
535-3581
A002 1/16" = 1'-0"
1 LIFE SAFETY FIRST BALCONY
CALCULATION OF OCCUPANT LOAD DETERMINED PER OBC 1003.2.2.2 (THE NUMBER IN "()" IDENTIFIES THE NUMBER OF OCCUPANTS):
ACTUAL FIXED SEATING LAYOUT
ROOM AREA (NET S.F.) DIVIDED BY 5 (ASSEMBLY STANDING)
ROOM AREA (NET S.F.) DIVIDED BY 7 (ASSEMBLY CHAIRS)
ROOM AREA (NET S.F.) DIVIDED BY 15 (ASSEMBLY WITH TABLES AND CHAIRS AND STAGES/PLATFORM AREAS)
ROOM AREA (GROSS S.F.) DIVIDED BY 100 (BUSINESS AREA)
ROOM AREA (GROSS S.F.) DIVIDED BY 200 (KITCHEN)
ROOM AREA (GROSS S.F.) DIVIDED BY 300 (STORAGE AREA)
1
2
3
4
5
6
7
A002 1/16" = 1'-0"
2 LIFE SAFETY SECOND BALCONY
A002 1/16" = 1'-0"
3 LIFE SAFETY CATWALK
4 PERMIT SET 04.25.08
5 ADDENDUM #2 05.16.08
6 ADDENDUM #3 05.23.08
10 PERMIT SET 06.10.08