HomeMy WebLinkAboutA111DN GENERAL DEMOLITION NOTES A. REFER TO MECHANICAL, ELECTICAL, PLUMBING & SITE DEMOLITION DRAWINGS FOR ADDITIONAL DEMOLITION ITEMS B. CONTRACTOR RESPONSIBLE FOR FIELD VERIFYING EXISTING CONDITIONS PRIOR TO REMOVAL WORK. C. CONTRACTOR RESPONSIBLE FOR REPAIR OF ANY DAMAGE TO EXISTING SURFACE, EQUIPMENT, ETC. IN AREAS TO REMAIN. THIS INCLUDES TRAVEL ROUTE FOR MATERIAL AND WORKMAN MOVEMENT, AND SURFACES DISTURBED BY TEMPORARY PARTITIONS. ALL AREAS TO BE DEMOLISHED OR DISTURBED BY ANY DEMOLITION ARE TO BE PATCHED TO MATCH EXISTING ADJACENT AND PREPARED FOR NEW FINISH. IN ALL AREAS OUTSIDE LIMITS OF WORK NEW FINISH IS TO BE COMPLETED TO MATCH EXISTING ADJACENT SURFACE. D. ALL REMOVAL WORK TO BE COORDINATED WITH NEW WORK TO ENSURE PROPER LIMITS AND SCOPE. E. CONTRACTOR RESPONSIBLE FOR PATCHING/REPAIR TO FLOORS, WALLS, ETC. UPON REMOVAL OF ANY FIXTURES, MECHANICAL EQUIPMENT, WALLS, ETC. F. CONTRACTOR RESPONSIBLE FOR COORDINATING WITH OWNER ANY CONFLICTS BETWEEN CONSTRUCTION HOURS AND CHURCH SERVICES AND ACTIVITIES. G. CONTRACTOR RESPONSIBLE FOR MINIMIZING CONSTRUCTION AREAS EXPOSED TO AND CHURCH SERVICES AND ACTIVITIES. IF AN AREA IS EXPOSED TO AN OCCUPIED AREA, THE CONTRACTOR SHALL PROVIDE A SECURE, DUST TIGHT TEMPORARY PARTITION SEPARATING CONSTRUCTION AREAS FROM OCCUPIED SPACE. H. CONTRACTOR RESPONSIBLE FOR MAINTAINING EXISTING FIRE RATINGS AND PATHS OF EGRESS FROM EXISTING BUILDING. I. CONTRACTOR RESPONSIBLE FOR SECURING OPENINGS TO THE EXTERIOR CAUSED BY DEMOLITION OF THE EXISTING BUILDING. J. EXISTING SANCTUARY DEMOLITION WORK TO BE COORDINATED W/ PHASE II OF PROJECT K. SALVAGE ALL FIRE EXTINGUISHERS AND TURN OVER TO CONSTRUCTION MANAGER. A3 A5 A6 A7 A8 A9 A10 A11 A12 AD AE AF AG HH AJ AK AL S101F 4.2 A1 A2 5 10 10 2 10 1 11 1 10 10 10 10 11 10 11 4 10 2 2 4 8 8 9 5 2 2 3 2 3 6 2 3 2 3 6 5 2 2 4 10 4 8 10 2 2 10 10 6 7 12 LIMITS OF FULL DEMOLITION PHASE I SEAL WITH WEATHER-TIGHT PROTECTION DURING WORK NO WORK LIMITS OF NEW WORK AND SELECTIVE DEMOLITION PHASE II SEE GEN. NOTE J. 5 15 15 8 8 LIMITS OF FULL DEMOLITION PHASE I SEAL WITH WEATHER-TIGHT PROTECTION DURING WORK 13 13 13 13 14 13 16 16 16 LIMITS OF NEW WORK AND SELECTIVE DEMOLITION PHASE II SEE GEN. NOTE J. FIRST FLOOR 817' - 7 5/8" LEVEL-2 UPPER LEVEL 830' - 7 5/8" A12 A11 A10 A9 A8 A7 3 A6 A5 A4 A3 4.8 4.3 4.2 3.8 2.2 2.1 1.3 A2 A1 4 5 4 1 1 8 8 8 8 6 6 2 2 5 3 5 2 7 FIRST FLOOR 817' - 7 5/8" LEVEL-2 UPPER LEVEL 830' - 7 5/8" AE AD AB AA A 2 2 5 9 5 1 FIRST FLOOR 817' - 7 5/8" LEVEL-2 UPPER LEVEL 830' - 7 5/8" A AA AB AD AE MAIN ROOF 873' - 1 5/8" 2 5 2 9 5 1 Date: Scale Drawn By Checked By Project Number ARCHITECTURE PLANNING INTERIOR DESIGN STRUCTURAL ENGINEERING 424 East Fourth Street Cincinnati, Ohio 45202 w w w . c h a r c h i t e c t s . c o m tel: 513/241/4474 fax: 513/241/0081 ISSUANCES COMPUTER FILE 1400 West Dorothy Lane Dayton, Ohio 45409-1310 Tel: (937) 224-0861 Fax: (937) 224-5777 3417 South Sherman Drive Beech Grove, IN 46107 Tel: (317) 780-1555 Fax: (317) 780-6525 750 North Orleans, Suite 400 Chicago, IL 60610 Tel: (312) 944-8230 Fax: (312) 944-8297 117 East Washington Street, Suite 200 Indianapolis, IN 46204 Tel: (317) 637-2222 Fax: (317) 637-2260 1137 West Taylor St. Suite 316 Chicago, IL 60607 Tel: (312) 224-8460 Fax: (312) 224-8961 1025 N.Watery Ln. Brigham City, UT 84302 TEL: (453) 723-5000 FAX: (453) 538-5506 6622 Kingspointe Parkway Orlando, FL 33819 Tel: (407) 816-9400 Fax: (407) 816-9300 900145 E T T E L C O T T A B J . M . A R C H I T E C T . . NO STATE OF I N D I A N A D E R E T S I G E R No. Description Date As indicated 6/12/2008 4:32:16 PM C:\!!!Bryan\Revit\NVCLC-bd.rvt A111 MAIN LEVEL FLOOR PLAN AND ELEVATIONS DEMOLITION NEW WORSHIP CENTER Checker Author 06-10-2008 535-3581 3 CD 50% 03.14.08 4 PERMIT SET 04.25.08 DEMOLITION PLAN KEYNOTES REMOVE EXISTING BLDG INCLUDING EXTERIOR WALLS, ROOF, FOUNDATIONS, WALKS, CEILINGS, INTERIOR WALLS, MECHANICAL, ELECTRICAL, PLUMBING, OR ANY OTHER BUILDINGS ITEMS UNLESS OTHERWISE NOTED REMOVE GYPSUM BOARD/ METAL STUD WALL IN AREA NOTED BY DASHED LINES. VERIFY EQUIPMENT TO BE RELOCATED OR DEMOLISHED IN DASHED AREAS. REMOVE GLAZING, WOOD FRAME REMOVE BRICK AND CMU WALL IN AREA NOTED BY DASHED LINES. VERIFY EQUIPMENT TO BE RELOCATED OR DEMOLISHED IN DASHED AREAS. PROVIDE NEW STEEL LINTEL WITH 8" BEARING AT EACH END NEEDLING AND SHORING AS REQUIRED TO STABILIZE ANY REMAINING MASONRY ABOVE. REMOVE PLATFORM, STEPS AND FRAMEWORK REMOVE PROJECTION SCREEN. SALVAGE FOR OWNER REUSE. REMOVE HANGING CROSS. SALVAGE FOR OWNER REUSE. REMOVE STAIRS. REMOVE EXISTING BAPTISMAL FONT & DISCONNET ANY ELECTRICAL OR PLUMBING CONNECTIONS. SALVAGE FOR OWNER REUSE IN NEW BUILDING. REMOVE EXISTING DOOR, FRAME, AND SIDELIGHT. EXISTING STRUCTURE TO REMAIN. REMOVE EXISTING FLOOR FINISHES. SAWCUT TO REMOVE PORTION OF SLAB ON GRADE AND PARTIALLY EXCAVATE AS NECESSARY FOR REPLACEMENT OF NEW FOOTINGS FOR NEW INTERIOR COLUMNS. SEE STRUCTURAL DWGS. REMOVE CONC. AND MASONRY. ALSO REMOVE ANY FOUNDATION TO ALLOW FOR NEW WORK. EXISTING PROJECTORS TO BE RELOCATED BY OWNER AT START OF PHASE II. REMOVE CONC. STAIR, FOUNDATION, AND WALKWAYS. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 ELEVATION KEY NOTES: REMOVE THIS PORTION OF EXISTING IN ITS ENTIRETY INCLUDING ALL EXTERIOR WALLS, ROOF, FOUNDATIONS, PARTITIONS, ALL MEP EQUIPMENT. THIS PORTION OF THE EXISTING BUILDING TO REMAIN EXCEPT WHERE SELECTIVE DEMOLITION IS INDICATED. REMOVE NORTH WALL OF STAIRS. REMOVE COPING. COORDINATE REMOVAL WITH NEW COPING FOLLOWING INSTALLATION OF EIFS ON THIS WALL. REMOVE FACE BRICK, MASONRY ACCENT BANDS, AND ALL MASONRY TIES AND ANCHORS. COORDINATE REMOVAL WITH NEW EIFS INSTALLATION ON THIS EXISTING NORTH WALL. REMOVE DOWNSPOUT. REMOVE PORTION OF RAILING TO ACCOMMODATE NEW WORK. REMOVE PORTION OF BRICK AND CMU WALL IN THIS AREA. PROVIDE NEW STEEL LINTEL WITH MIN. 8” BEARING ON EACH END AND NEEDLING AND SHORING AS REQUIRED TO STABALIZE WALL ABOVE. REMOVE STOREFRONT AND GLAZING SYSTEM. 1 2 3 4 5 6 7 8 9 A111 3/32" = 1'-0" 1 DEMO-LEVEL-1 MAIN LEVEL A111 3/32" = 1'-0" 2 DEMO-NORTH BUILDING ELEVATION A111 3/32" = 1'-0" 3 DEMO ELEVATION-EAST A111 3/32" = 1'-0" 4 DEMO ELEVATION-WEST 5 ADDENDUM #2 05.16.08 10 PERMIT SET 06.10.08