Loading...
HomeMy WebLinkAboutA425MAIN ROOF 873' - 1 5/8" FIRST BALCONY 835' - 9 5/8" SECOND BALCONY 851' - 4 5/8" CATWALK 860' - 10 5/8" S FIRST BALCONY 33' - 2" SECOND BALCONY 48' - 9" CATWALK 58' - 3" MAIN ROOF 70' - 6" LEVEL-2 UPPER LEVEL 28' - 0" TYPE - C PREFINISHED ALUMINUM COPING; NO EXPOSED FASTENERS 2" RIGID INSULATION; BUILDING WRAP; 1/2" EXTERIOR GYPSUM SHEATHING & 6" STEEL STUDS @ 16" O.C.; 6" BATT INSULATION & VAPOR BARRIER; 5/8" TYPE 'X' GYPSUM SHEATHING TYPE - C FULLY ADHERED EPDM ROOF SYSTEM; 2 LAYERS OF 1.5" RIGID INSULATION ON STEEL DECK; ADDITIONAL TAPERED INSULATION AS REQUIRED TO MAINTAIN MINIMUM SLOPE 1/4" PER FT. REF. A251 FOR TAPERED INSULATION LOCATIONS CONTINUE ROOF MEMBRANE UP PARAPET WALL; TERMINATE BENEATH COPING STEEL ROOF STRUCTURE; SEE S-SERIES DRWGS. PERIMETER FIRE CONTAINMENT SYSTEM 2" RIGID INSULATION; BUILDING WRAP; 1/2" EXTERIOR GYPSUM SHEATHING & 6" STEEL STUDS @ 16" O.C. 6" STEEL STUDS @ 16" O.C. CLIPPED TO VERTICAL STRUCTURAL STEEL WITH 1/2" DENSDECK SHEATHING TYPE - C INTERIOR PARTITION; SEE SCHEDULE FOR TYPE FULLY ADHERED EPDM ROOF SYSTEM; 2 LAYERS OF 1.5" RIGID INSULATION ON STEEL DECK; ADDITIONAL TAPERED INSULATION AS REQUIRED TO MAINTAIN MINIMUM SLOPE 1/4" PER FT. REF. A251 FOR TAPERED INSULATION LOCATIONS CONTOL JOINT; REFER BUILDING ELEVATIONS INTERIOR PARTITION; SEE SCHEDULE FOR TYPE INTERIOR PARTITION; SEE SCHEDULE FOR TYPE CONCRETE FOUNDATION; SEE F-SERIES DRWGS. 6' - 9 5/8" A603 1 SIM. A602 15 A602 14 SIM. SIM. MAIN ROOF 873' - 1 5/8" FIRST BALCONY 835' - 9 5/8" SECOND BALCONY 851' - 4 5/8" CATWALK 860' - 10 5/8" T TYPE - C PREFINISHED ALUMINUM COPING; NO EXPOSED FASTENERS 2" RIGID INSULATION; BUILDING WRAP; 1/2" EXTERIOR GYPSUM SHEATHING & 6" STEEL STUDS @ 16" O.C.; 6" BATT INSULATION & VAPOR BARRIER; 5/8" TYPE 'X' GYPSUM SHEATHING TYPE - C FULLY ADHERED EPDM ROOF SYSTEM; 2 LAYERS OF 1.5" RIGID INSULATION ON STEEL DECK; ADDITIONAL TAPERED INSULATION AS REQUIRED TO MAINTAIN MINIMUM SLOPE 1/4" PER FT. REF. A251 FOR TAPERED INSULATION LOCATIONS CONTINUE ROOF MEMBRANE UP PARAPET WALL; TERMINATE BENEATH COPING STEEL ROOF STRUCTURE; SEE S-SERIES DRWGS. PERIMETER FIRE CONTAINMENT SYSTEM 2" RIGID INSULATION; BUILDING WRAP; 1/2" EXTERIOR GYPSUM SHEATHING & 6" STEEL STUDS @ 16" O.C. 6" STEEL STUDS @ 16" O.C. CLIPPED TO VERTICAL STRUCTURAL STEEL WITH 1/2" DENSDECK SHEATHING TYPE - C INTERIOR PARTITION; SEE SCHEDULE FOR TYPE FULLY ADHERED EPDM ROOF SYSTEM; 2 LAYERS OF 1.5" RIGID INSULATION ON STEEL DECK; ADDITIONAL TAPERED INSULATION AS REQUIRED TO MAINTAIN MINIMUM SLOPE 1/4" PER FT. REF. A251 FOR TAPERED INSULATION LOCATIONS INTERIOR PARTITION; SEE SCHEDULE FOR TYPE INTERIOR PARTITION; SEE SCHEDULE FOR TYPE 37' - 4" CONTOL JOINT; REFER BUILDING ELEVATIONS 6' - 9 5/8" A603 1 SIM. A602 15 SIM. A602 14 SIM. FIRST BALCONY 835' - 9 5/8" SECOND BALCONY 851' - 4 5/8" 2.1 2.2 TYPE - B CONTINUOUS ALUMINUM ROOF EDGE, NO EXPOSED FASTNERS 2" RIGID INSULATION; BUILDING WRAP; 1/2" EXTERIOR GYPSUM SHEATHING & 6" STEEL STUDS @ 16" O.C.; 6" BATT INSULATION & VAPOR BARRIER; 5/8" TYPE 'X' GYPSUM SHEATHING TYPE - B FULLY ADHERED EPDM ROOF SYSTEM; 2 LAYERS OF 1.5" RIGID INSULATION ON STEEL DECK; ADDITIONAL TAPERED INSULATION AS REQUIRED TO MAINTAIN MINIMUM SLOPE 1/4" PER FT. REF. A251 FOR TAPERED INSULATION LOCATIONS PERIMETER FIRE CONTAINMENT SYSTEM SUSPENDED ACOUSTIC CEILING; REFER TO SCHEDULE FOR TYPE 15' - 7" CONCRETE ON STEEL DECK ON STEEL STRUCTURE; REFER TO S-SERIES DRWGS. FULLY ADHERED EPDM ROOF SYSTEM; 2 LAYERS OF 1.5" RIGID INSULATION ON STEEL DECK; ADDITIONAL TAPERED INSULATION AS REQUIRED TO MAINTAIN MINIMUM SLOPE 1/4" PER FT. REF. A251 FOR TAPERED INSULATION LOCATIONS STEEL ROOF/FLOOR STRUCTURE; REFER TO S- SERIES DRWGS. A602 11 6" FIRST BALCONY 835' - 9 5/8" 2.1 2.2 EXISTING ROOF 2" RIGID INSULATION; BUILDING WRAP; 1/2" EXTERIOR GYPSUM SHEATHING & 6" STEEL STUDS @ 16" O.C. FULLY ADHERED EPDM ROOF SYSTEM; 2 LAYERS OF 1.5" RIGID INSULATION ON STEEL DECK; ADDITIONAL TAPERED INSULATION AS REQUIRED TO MAINTAIN MINIMUM SLOPE 1/4" PER FT. REF. A251 FOR TAPERED INSULATION LOCATIONS WALL BEYOND TYPE - C 202B SCHEDULED CEILING 6" 7' - 2" STEEL ROOF & FLOOR STRUCTURE; SEE S-SERIES DRWGS. A603 9 Date: Scale Drawn By Checked By Project Number ARCHITECTURE PLANNING INTERIOR DESIGN STRUCTURAL ENGINEERING 424 East Fourth Street Cincinnati, Ohio 45202 w w w . c h a r c h i t e c t s . c o m tel: 513/241/4474 fax: 513/241/0081 ISSUANCES COMPUTER FILE 1400 West Dorothy Lane Dayton, Ohio 45409-1310 Tel: (937) 224-0861 Fax: (937) 224-5777 3417 South Sherman Drive Beech Grove, IN 46107 Tel: (317) 780-1555 Fax: (317) 780-6525 750 North Orleans, Suite 400 Chicago, IL 60610 Tel: (312) 944-8230 Fax: (312) 944-8297 117 East Washington Street, Suite 200 Indianapolis, IN 46204 Tel: (317) 637-2222 Fax: (317) 637-2260 1137 West Taylor St. Suite 316 Chicago, IL 60607 Tel: (312) 224-8460 Fax: (312) 224-8961 1025 N.Watery Ln. Brigham City, UT 84302 TEL: (453) 723-5000 FAX: (453) 538-5506 6622 Kingspointe Parkway Orlando, FL 33819 Tel: (407) 816-9400 Fax: (407) 816-9300 900145 E T T E L C O T T A B J . M . A R C H I T E C T . . NO STATE OF I N D I A N A D E R E T S I G E R No. Description Date 1/2" = 1'-0" 6/13/2008 10:49:38 AM C:\!!!Bryan\Revit\NVCLC-bd.rvt A425 WALL SECTIONS NEW WORSHIP CENTER Checker Author 06-10-2008 535-3581 A425 1/2" = 1'-0" 1 WALL SECTION A425 1/2" = 1'-0" 2 WALL SECTION A425 1/2" = 1'-0" 3 WALL SECTION A425 1/2" = 1'-0" 4 WALL SECTION SECTION KEY NOTES TYPE-A1 FACE BRICK TYPE-A2 SPLIT FACED CONCRETE MASONRY UNITS TYPE-B CENTRIA EXPOSED FASTENER ECONOLAP 3/4" (HORIZONTAL) (BASIS OF DESIGN) TYPE-C WATER-DRAINAGE EXTERIOR INSULATION AND FINISH SYSTEM (EIFS) TYPE-D EXTERIOR ALUMINUM-FRAMED STOREFRONT SYSTEM EXTERIOR COLD FORMED METAL FRAMING GENERAL NOTES: 1. ALL LIGHT GAUGE FRAMING SHALL BE DESIGNED IN ACCORDANCE WITH THE AMERICAN IRON AND STEEL INSTITUTE, “SPECIFICATION FOR DESIGN OF COLD- FORMED STEEL STRUCTURAL MEMBERS” 2. CONTRACTOR SHALL SUBMIT DESIGN CALCULATIONS AND SHOP DRAWINGS, SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN INDIANA FOR ALL LIGHT GAUGE EXTERIOR COLD FORMED FRAMING SHOWING SIZE AND GAUGE OF ALL MEMBERS AND COMPLETE CONNECTION DESIGN. 3. ALL MEMBERS SHALL BE FORMED OF CORROSION- RESISTANT STEEL, CONFORMING TO THE REQUIREMENTS OF ASTM A653. 4. ALL STUDS SHALL BE HAVE A MINIMUM THICKNESS AND A MAXIMUM SPACING AS REQUIRED BY THE DESIGN, EXCEPT THAT THE THICKNESS SHALL NOT BE LESS THAN 18 GAUGE AND THE SPACING SHALL NOT EXCEED 16” ON CENTER. 5. ALL STRUCTURAL MEMBERS SHALL BE GALVANIZED MEETING ASTM A924 WITH A G60 COATING. 6. WELDS SHALL BE PERFORMED BY WELDERS QUALIFIED IN ACCORDANCE WITH SECTION 6.0 OF THE AMERICAN WELDING SOCIETY’S, “STRUCTURAL WELDING CODE-SHEET METAL”, (AWS D1.3) 7. STUDS, HEADERS, RUNNERS AND STRAPS SHALL HAVE A MINIMUM YIELD STRENGTH OF Fy = 33 ksi FOR 18 GAUGE MEMBERS AND THINNER AND Fy = 50 ksi FOR 16 GAUGE MEMBERS AND THICKER. 8. TORCH CUTTING OF HOLES OR MEMBERS IS NOT PERMITTED. GENERAL NOTES KEY NOTES 5 ADDENDUM # 2 05.16.08 9 ADDENDUM # 6 06.10.08 10 PERMIT SET 06.10.08