HomeMy WebLinkAboutA427MAIN ROOF 873' - 1 5/8" T O MASONRY 841' - 9 5/8" FIRST BALCONY 835' - 9 5/8" SECOND BALCONY 851' - 4 5/8" CATWALK 860' - 10 5/8" P12 FIRST BALCONY 33' - 2" SECOND BALCONY 48' - 9" CATWALK 58' - 3" MAIN ROOF 70' - 6" 15' - 7" 21' - 9" 37' - 4" 1' - 5 7/8" PREFINISHED METAL COPING TYPE B FULLY ADHERED EPDM ROOF SYSTEM; 2 LAYERS OF 1.5" RIGID INSULATION ON STEEL DECK; ADDITIONAL TAPERED INSULATION AS REQUIRED TO MAINTAIN MINIMUM SLOPE 1/4" PER FT. REF. A251 FOR TAPERED INSULATION LOCATIONS CONTINUE ROOF MEMBRANE UP PARAPET WALL, TERMINATE BENEATH COPING 2" RIGID INSULATION; BUILDING WRAP; 1/2" EXTERIOR GYPSUM SHEATHING & 6" STEEL STUDS @ 16" O.C.; 1/2" DENSDECK EXTERIOR SHEATHING & ROOF MEMBRANE PERIMETER FIRE CONTAINMENT SYSTEM STEEL ROOF STRUCTURE; SEE S-SERIES DRWGS. FULLY ADHERED EPDM ROOF SYSTEM; 2 LAYERS OF 1.5" RIGID INSULATION ON STEEL DECK; ADDITIONAL TAPERED INSULATION AS REQUIRED TO MAINTAIN MINIMUM SLOPE 1/4" PER FT. REF. A251 FOR TAPERED INSULATION LOCATIONS CONCRETE SLAB ON STEEL DECK; REFER TO S-SERIES DRWGS. STEEL FLOOR STRUCTURE; REFER TO S-SERIES DRWGS. CONCRETE SLAB ON STEEL DECK; REFER TO S-SERIES DRWGS. STEEL FLOOR STRUCTURE; REFER TO S-SERIES DRWGS. TYPE B PERIMETER FIRE CONTAINMENT SYSTEM PERIMETER FIRE CONTAINMENT SYSTEM INTERIOR PARTITION; REFER TO SCHEDULE FOR TYPE 2" RIGID INSULATION; BUILDING WRAP; 1/2" EXTERIOR GYPSUM SHEATHING & 6" STEEL STUDS @ 16" O.C.; 6" BATT INSULATION & VAPOR BARRIER; 5/8" TYPE 'X' GYPSUM SHEATHING 2" RIGID INSULATION; BUILDING WRAP; 1/2" EXTERIOR GYPSUM SHEATHING & 6" STEEL STUDS @ 16" O.C.; 6" BATT INSULATION & VAPOR BARRIER; 5/8" TYPE 'X' GYPSUM SHEATHING A602 16 SIM. A602 SIM. 13 SIM. FIRST FLOOR 817' - 7 5/8" LEVEL-2 UPPER LEVEL 830' - 7 5/8" FIRST BALCONY 835' - 9 5/8" PIT ROOF 824' - 7 5/8" N 6' - 0 3/8" 3 5/8" 7' - 4 3/8" 3 5/8" 8' - 9 VARIES 11/16" 18' - 2" 14' - 0" PRECAST CONCRETE BAND TYPE - A-2 PREFINISHED ALUMINUM COPING; NO EXPOSED FASTENERS CONCRETE SLAB ON GRADE WITH VAPOR BARRIER ON COMPACTED GRANULAR BASE 2" RIGID PERIMETER FOUNDATION INSULATION; 24" HORIZ., & VERT. TO TOP OF FOOTING 2" RIGID INSULATION; BUILDING WRAP; 1/2" EXTERIOR GYPSUM SHEATHING & 6" STEEL STUDS @ 16" O.C.; 6" BATT INSULATION & VAPOR BARRIER; 5/8" TYPE 'X' GYPSUM SHEATHING FULLY ADHERED EPDM ROOF SYSTEM; 2 LAYERS OF 1.5" RIGID INSULATION ON STEEL DECK; ADDITIONAL TAPERED INSULATION AS REQUIRED TO MAINTAIN MINIMUM SLOPE 1/4" PER FT. REF. A251 FOR TAPERED INSULATION LOCATIONS CONTINUE ROOF MEMBRANE UP PARAPET WALL TERMINATE BENEATH COPING STEEL ROOF STRUCTURE; SEE PERIMETER FIRE S-SERIES DRWGS. CONTAINMENT SYSTEM 2" RIGID INSULATION; BUILDING WRAP; 1/2" EXTERIOR GYPSUM SHEATHING & 6" STEEL STUDS @ 16" O.C. FINISHED GRADE; REFER TO C-SERIES DRWGS. CONCRETE FOUNDATION; REFER TO F-SERIES DRWGS. TYPE - A-2 SUSPENDED ACOUSTIC CEILING; REFER TO SCHEDULE FOR TYPE A602 7 SIM. A602 6 SIM. A602 8 SIM. FIRST FLOOR 817' - 7 5/8" PIT LEVEL 808' - 7 5/8" PIT ROOF 824' - 7 5/8" J 028 W4 W4 RECORDING STUDIO 029 AUDIO CONTROL 026 CONTINUOUS PRE-FINISHED ALUMINUM DRIP EDGE FULLY ADHERED EPDM ROOF SYSTEM; 2 LAYERS OF 1.5" RIGID INSULATION ON CONCRETE AND STEEL DECK; ADDITIONAL TAPERED INSULATION AS REQUIRED TO MAINTAIN MINIMUM SLOPE 1/4" PER FT. REF. A251 FOR TAPERED INSULATION LOCATIONS CONTINUE ROOF MEMBRANE UP PARAPET WALL; TERMINATE BENEATH DRIP EDGE 2" RIGID INSULATION; BUILDING WRAP; 1/2" EXTERIOR GYPSUM SHEATHING & 6" STEEL STUDS @ 16" O.C.; 6" BATT INSULATION & VAPOR BARRIER; 5/8" TYPE 'X' GYPSUM SHEATHING INTERIOR PARTITION; SEE SCHEDULE FOR TYPE FULLY ADHERED EPDM ROOF SYSTEM; 2 LAYERS OF 1.5" RIGID INSULATION ON STEEL DECK; ADDITIONAL TAPERED INSULATION AS REQUIRED TO MAINTAIN MINIMUM SLOPE 1/4" PER FT. REF. A251 FOR TAPERED INSULATION LOCATIONS INTERIOR PARTITION; SEE SCHEDULE FOR TYPE SCHEDULED CEILING SCHEDULED CEILING 9' - 0" 7' - 0" 6' - VARIES 11 1/4" Date: Scale Drawn By Checked By Project Number ARCHITECTURE PLANNING INTERIOR DESIGN STRUCTURAL ENGINEERING 424 East Fourth Street Cincinnati, Ohio 45202 w w w . c h a r c h i t e c t s . c o m tel: 513/241/4474 fax: 513/241/0081 ISSUANCES COMPUTER FILE 1400 West Dorothy Lane Dayton, Ohio 45409-1310 Tel: (937) 224-0861 Fax: (937) 224-5777 3417 South Sherman Drive Beech Grove, IN 46107 Tel: (317) 780-1555 Fax: (317) 780-6525 750 North Orleans, Suite 400 Chicago, IL 60610 Tel: (312) 944-8230 Fax: (312) 944-8297 117 East Washington Street, Suite 200 Indianapolis, IN 46204 Tel: (317) 637-2222 Fax: (317) 637-2260 1137 West Taylor St. Suite 316 Chicago, IL 60607 Tel: (312) 224-8460 Fax: (312) 224-8961 1025 N.Watery Ln. Brigham City, UT 84302 TEL: (453) 723-5000 FAX: (453) 538-5506 6622 Kingspointe Parkway Orlando, FL 33819 Tel: (407) 816-9400 Fax: (407) 816-9300 900145 E T T E L C O T T A B J . M . A R C H I T E C T . . NO STATE OF I N D I A N A D E R E T S I G E R No. Description Date 1/2" = 1'-0" 6/13/2008 10:52:20 AM C:\!!!Bryan\Revit\NVCLC-bd.rvt A427 WALL SECTIONS NEW WORSHIP CENTER Checker Author 06-10-2008 535-3581 A427 1/2" = 1'-0" 1 WALL SECTION A427 1/2" = 1'-0" 2 WALL SECTION SECTION KEY NOTES TYPE-A1 FACE BRICK TYPE-A2 SPLIT FACED CONCRETE MASONRY UNITS TYPE-B CENTRIA EXPOSED FASTENER ECONOLAP 3/4" (HORIZONTAL) (BASIS OF DESIGN) TYPE-C WATER-DRAINAGE EXTERIOR INSULATION AND FINISH SYSTEM (EIFS) TYPE-D EXTERIOR ALUMINUM-FRAMED STOREFRONT SYSTEM EXTERIOR COLD FORMED METAL FRAMING GENERAL NOTES: 1. ALL LIGHT GAUGE FRAMING SHALL BE DESIGNED IN ACCORDANCE WITH THE AMERICAN IRON AND STEEL INSTITUTE, “SPECIFICATION FOR DESIGN OF COLD- FORMED STEEL STRUCTURAL MEMBERS” 2. CONTRACTOR SHALL SUBMIT DESIGN CALCULATIONS AND SHOP DRAWINGS, SEALED BY A PROFESSIONAL ENGINEER REGISTERED IN INDIANA FOR ALL LIGHT GAUGE EXTERIOR COLD FORMED FRAMING SHOWING SIZE AND GAUGE OF ALL MEMBERS AND COMPLETE CONNECTION DESIGN. 3. ALL MEMBERS SHALL BE FORMED OF CORROSION- RESISTANT STEEL, CONFORMING TO THE REQUIREMENTS OF ASTM A653. 4. ALL STUDS SHALL BE HAVE A MINIMUM THICKNESS AND A MAXIMUM SPACING AS REQUIRED BY THE DESIGN, EXCEPT THAT THE THICKNESS SHALL NOT BE LESS THAN 18 GAUGE AND THE SPACING SHALL NOT EXCEED 16” ON CENTER. 5. ALL STRUCTURAL MEMBERS SHALL BE GALVANIZED MEETING ASTM A924 WITH A G60 COATING. 6. WELDS SHALL BE PERFORMED BY WELDERS QUALIFIED IN ACCORDANCE WITH SECTION 6.0 OF THE AMERICAN WELDING SOCIETY’S, “STRUCTURAL WELDING CODE-SHEET METAL”, (AWS D1.3) 7. STUDS, HEADERS, RUNNERS AND STRAPS SHALL HAVE A MINIMUM YIELD STRENGTH OF Fy = 33 ksi FOR 18 GAUGE MEMBERS AND THINNER AND Fy = 50 ksi FOR 16 GAUGE MEMBERS AND THICKER. 8. TORCH CUTTING OF HOLES OR MEMBERS IS NOT PERMITTED. GENERAL NOTES 1/2" = 1'-0" KEY NOTES A427 3 WALL SECTION 5 ADDENDUM # 2 05.16.08 9 ADDENDUM # 6 06.10.08 10 PERMIT SET 06.10.08