Loading...
HomeMy WebLinkAboutA50821 EQUAL SPACES 42" HIGH TELESCOPING SAFETY POST WITH EYEHOOK 3'-0" X 8'-0 ROOF HATCH WITH 1" FIBERGLASS INSULATION IN COVER, COMBINATION LOCK STRIKE AND PADLOCK HASP AND SPRING LATCH WITH INSIDE-OUTSIDE HANDLES CURB WITH INTEGRAL CAPFLASHING AND POSIFLASH PAINTED ALTERNATING TREAD DEVICE EXISTING PARTITION EXISTING STEEL BEAM GASKET AT PERIMETER EDGE OF ROOF HATCH BRACKET ALTERNATING TREAD DEVICE OFF OF EXISTING BEAM CLIP ANGLE AND EXP. BOLT TO FLOOR, EACH SIDE PIT ROOF 824' - 7 5/8" J 6' - 9" V.I.F. CONTINUOUS PRE-FINISHED ALUMINUM DRIP EDGE FULLY ADHERED EPDM ROOF SYSTEM; 2 LAYERS OF 1.5" RIGID INSULATION ON STEEL DECK; ADDITIONAL TAPERED INSULATION AS REQUIRED TO MAINTAIN MINIMUM SLOPE 1/4" PER FT. REF. A251 FOR TAPERED INSULATION LOCATIONS CONTINUE ROOF MEMBRANE UP PARAPET WALL; TERMINATE BENEATH DRIP EDGE 2" RIGID INSULATION; BUILDING WRAP; 1/2" EXTERIOR GYPSUM SHEATHING & 6" STEEL STUDS @ 16" O.C.; 6" BATT INSULATION & VAPOR BARRIER; 5/8" TYPE 'X' GYPSUM SHEATHING FULLY ADHERED EPDM ROOF SYSTEM; 2 LAYERS OF 1.5" RIGID INSULATION ON STEEL DECK; ADDITIONAL TAPERED INSULATION AS REQUIRED TO MAINTAIN MINIMUM SLOPE 1/4" PER FT. REF. A251 FOR TAPERED INSULATION LOCATIONS 8" R 1' - 1" CONSTRUCT LADDER RAILS FROM 3/8" X3" BAR STOCK. SPACE SIDES 24"APART. NOTE: ALL STEEL FOR LADDER, INCLUDING BRACKETS AND FASTENERSTO BE HOT DIPPED GALVANIZED STEEL 3/4" DIA. RUNGS AT 12" O.C. TYP. MOUNTING BRACKETS WITH 3/4" EXP BOLTS INTO EXTERIOR WALL AT 4'-0" O.C. TYP. BRACKETS TO BE MADE FROM 3/8" X3" BAR STOCK. PROVIDE NON-COMB. CONTINUOUS WD BLOCKING AS REQUIRED FOR BRACKET ATTACHEMENTS Date: Scale Drawn By Checked By Project Number ARCHITECTURE PLANNING INTERIOR DESIGN STRUCTURAL ENGINEERING 424 East Fourth Street Cincinnati, Ohio 45202 w w w . c h a r c h i t e c t s . c o m tel: 513/241/4474 fax: 513/241/0081 ISSUANCES COMPUTER FILE 1400 West Dorothy Lane Dayton, Ohio 45409-1310 Tel: (937) 224-0861 Fax: (937) 224-5777 3417 South Sherman Drive Beech Grove, IN 46107 Tel: (317) 780-1555 Fax: (317) 780-6525 750 North Orleans, Suite 400 Chicago, IL 60610 Tel: (312) 944-8230 Fax: (312) 944-8297 117 East Washington Street, Suite 200 Indianapolis, IN 46204 Tel: (317) 637-2222 Fax: (317) 637-2260 1137 West Taylor St. Suite 316 Chicago, IL 60607 Tel: (312) 224-8460 Fax: (312) 224-8961 1025 N.Watery Ln. Brigham City, UT 84302 TEL: (453) 723-5000 FAX: (453) 538-5506 6622 Kingspointe Parkway Orlando, FL 33819 Tel: (407) 816-9400 Fax: (407) 816-9300 900145 E T T E L C O T T A B J . M . A R C H I T E C T . . NO STATE OF I N D I A N A D E R E T S I G E R No. Description Date As indicated 6/13/2008 11:02:32 AM C:\!!!Bryan\Revit\NVCLC-bd.rvt A508 STAIR DETAILS NEW WORSHIP CENTER Checker Author 06-10-2008 535-3581 A508 3/4" = 1'-0" 4 ALTERNATING TREAD DEVICE 4 PERMIT SET 04.25.08 A508 1/2" = 1'-0" 1 PIT ROOF ACCESS LADDER 7 ADDENDUM #4 05.30.08 9 ADDENDUM # 6 06.10.08 10 PERMIT SET 06.10.08