HomeMy WebLinkAboutA510P.LAM FINISH UNDERSIDE
OF TOE KICK
4"
3"
BASE AS SCHEDULED
NON-COMBUSTIBLE
WOOD BLOCKING
FINISHED FLOOR
PROVIDE NON-COM. WOOD
BLOCKING AS REQUIRED IN STUD
TO SUPPORT BASE CABINET. TYP.
PLASTIC LAMINATE BASE
CABINET AND ADJUSTABLE
SHELF; SHELF STANDARDS,
RECESSED FOR FLUSH
INTERIORS
SOLID SURFACE
COUNTERTOP WITH 3/4"
BACK AND SIDE SPLASH
2' - 10"
2' - 1"
9B.1
9B.2
9D.1 9D.2
CABINET DOOR
SCRIBE #2
CABINET DOOR
SCRIBE #2
CABINET DOOR
LIGHT VALANCE
WALL
CABINET DOOR
SCRIBE #2
WALL
CABINET DOOR
SCRIBE #2
CABINET PULL-
AFIX CABINET
PULL ABOVE
CABINET BOTTOM
A5.10
9B.1
A5.10
9B.2
SCRIBE #1
CABINET BODY
ALIGN
ALIGN
*NOTE: WHERE BASE AND WALL CABINETS APPEAR
WITHOUT DOORS, SCRIBE AND FILLER DETAIL
WILL BE REVIEWED IN SHOP DRAWING PHASE.
ALL SPECIAL CONDITIONS WILL BE ASSESSED
IN SHOP DRAWING SUBMITTALS.
CABINET BODY
ALIGN
ALIGN
SCRIBE #1
CABINET DOOR
CABINET BODY
ALIGN
ALIGN
CABINET BODY
FASTENER TO BE
CONCEALED
*NOTE: VALANCE TO BE CONTINUOUS ACROSS
FRONT AND SIDES OF WALL CABINETS WHICH
ARE EXPOSED, WITH MINIMAL SEAMS.
WHERE SEAMS ARE NECESSARY,
PLACE SEAM ALIGNING WITH CABINET BODY JOINT.
SCRIBE #1
CABINET BODY
ALIGN
ALIGN
CABINET BODY
ALIGN
ALIGN
SCRIBE #1
CABINET DOOR
CABINET BODY
ALIGN
ALIGN
FILLER PANEL TO BE FLUSH
WITH CABINET BODY FACE
SCRIBE TO BE FLUSH WITH
FACE OF CABINET DOOR
*NOTE: WHERE WALL CABINETS
DO NOT ABUT A SOFFIT,
FILLER IS TO RUN CONTINUOUSLY
ACROSS THE TOP OF THE
CABINET TO BACK WALL.
SOFFIT
TYPICAL WALL
CABINET
ALIGN
FILLER PANEL TO BE FLUSH
WITH CABINET BODY FACE
SCRIBE TO BE FLUSH WITH
FACE OF CABINET DOOR
SILENCER
COUNTER SINK
HARDWARE
BASE AS SCHEDULED
TYPICAL BASE
CABINET
*NOTE: THESE DRAWINGS ARE MEANT
TO EXPRESS INTENT OF
CASEWORK APPEARANCE ONLY
3' - 0"
2' - 1"
4"
2' - 0" 2' - 6"
1' - 0"
1' - 1 1/2" ±
P.LAM FINISH UNDERSIDE
OF TOE KICK
4"
3"
BASE AS SCHEDULED
NON-COMBUSTIBLE
WOOD BLOCKING
FINISHED FLOOR
PROVIDE NON-COM. WOOD
BLOCKING AS REQUIRED IN STUD
TO SUPPORT BASE CABINET. TYP.
PLASTIC LAMINATE BASE CABINET,
NO DRAWERS OR SHELVES AT SINK
CABINETS
PLASTIC LAMINATE
COUNTERTOP WITH 3/4" BACK
AND SIDE SPLASH
1 1/2"
1"
6"
PROVIDE NON-COM. WOOD
BLOCKING AS REQUIRED IN STUD
TO SUPPORT WALL CABINET. TYP.
PLASTIC LAMINATE WALL CABINET
BODY WITH ADJUSTABLE
SHELVES; SHELF STANDARDS,
RECESSED FOR FLUSH INTERIORS
AT 5/8" INCREMENTS.
CONSTRUCTION TO HAVE
CONCEALED FASTENERS
ALL SCHEDULED PARTITIONS
ASSEMBLIES ARE TO EXTEND
FROM TOP OF FLOOR SLAB TO
UNDERSIDE OF DECK ABOVE.
UNLESS NOTED OTHERWISE;
BRACE AS REQUIRED TO
SECURE TO STRUCTURE ABOVE
UNDERSIDE OF STRUCTURE
ABOVE;V.I.F.
CEILING SYSTEM PER REFLECTED
CEILING PLAN
FIRST FLOOR
817' - 7 5/8"
PIT LEVEL
808' - 7 5/8"
W3
12' - 9"
1' - 6" 3' - 6" 2' - 6" 2' - 6" 2' - 6" 1 1/2"
3' - 0"
3 1/2"
2' - 0" 2' - 6"
LEVEL-0 PIT LEVEL
6' - 0"
LEVEL-1
15' - 0"
1
A510
FIRST FLOOR
817' - 7 5/8"
PIT LEVEL
808' - 7 5/8"
H1.5
FIELD VERIFY WALL = 5' - 7 7/8"
3' - 0" 2' - 0" 2' - 6"
1
A510
1_1
2"
2'-0" U.N.O.
2'-6" 2'-4"
3" 1'-8
_1
4"
8" 1'-8
_1
2"
45°
6
_1
2"
PROVIDE NON-COM
WOOD BLOCKING IN
STUD SPACE TO FOR
INSTALLATION OF
FUTURE SYSTEM
FURNITURE BINS
BRACE AS REQUIRED.
SECURE TO
STRUCTURE ABOVE.
PLASTIC LAMINATE COUNTERTOP
PLASTIC LAMINATE
ATTACHMENT
BLOCKING. 1x3
PLASTIC LAMINATE
CONT. WALL CLEAT.
LEG SUPPORT AT 48"
O.C. SPACING: 3/4"
PLYWOOD IN P. LAM FINISH
RESILIENT BASE
SCRIBE TIGHT TO
WALL AND PROVIDE
CONT. CAULK JOINT.
1_1
2"
3'-6" U.N.O.
2'-6"
3" 3'-2
_1
4"
8" 1'-8
_1
2"
45°
3'-0"
4"
1'-6_1
2"
3
_1
4"
PROVIDE NON-COM WOOD
BLOCKING IN STUD SPACE TO
FOR INSTALLATION OF FUTURE
SYSTEM FURNITURE BINS
PLASTIC LAMINATE COUNTERTOP
PLASTIC LAMINATE ATTACHMENT
BLOCKING. 1x3 PLASTIC
LAMINATE CONT. WALL CLEAT.
LEG SUPPORT AT 48" O.C. SPACING:
3/4" PLYWOOD IN P. LAM FINISH
RESILIENT BASE
SCRIBE TIGHT TO WALL AND
PROVIDE CONT. CAULK JOINT.
SLOPED FLOOR
RESILIENT BASE
PLASTIC LAMINATE SCREEN
CABLE MANAGEMENT TROUGH
CABLE MANAGEMENT SLOT
OPENINGS ACROSS ENTIRE LENGTH
OF COUNTER.. MAXIMIZE WIDTHS A
HARDWOOD CAP AND TRIM, STAINDED
Date: Scale
Drawn By
Checked By
Project
Number
ARCHITECTURE
PLANNING
INTERIOR DESIGN
STRUCTURAL ENGINEERING
424 East Fourth Street
Cincinnati, Ohio 45202
w w w . c h a r c h i t e c t s . c o m
tel: 513/241/4474 fax: 513/241/0081
ISSUANCES
COMPUTER FILE
1400 West Dorothy Lane
Dayton, Ohio 45409-1310
Tel: (937) 224-0861
Fax: (937) 224-5777
3417 South Sherman Drive
Beech Grove, IN 46107
Tel: (317) 780-1555
Fax: (317) 780-6525
750 North Orleans, Suite 400
Chicago, IL 60610
Tel: (312) 944-8230
Fax: (312) 944-8297
117 East Washington
Street, Suite 200
Indianapolis, IN 46204
Tel: (317) 637-2222
Fax: (317) 637-2260
1137 West Taylor St.
Suite 316
Chicago, IL 60607
Tel: (312) 224-8460
Fax: (312) 224-8961
1025 N.Watery Ln.
Brigham City, UT 84302
TEL: (453) 723-5000
FAX: (453) 538-5506
6622 Kingspointe
Parkway
Orlando, FL 33819
Tel: (407) 816-9400
Fax: (407) 816-9300
900145
E
T
T
E
L
C
O
T
T
A
B
J
.
M
.
A
R
C
H
I
T
E
C
T
. .
NO
STATE OF
I
N
D
I
A
N
A
D
E
R
E
T
S
I
G
E
R
No. Description Date
As indicated
6/13/2008 11:03:01 AM
C:\!!!Bryan\Revit\NVCLC-bd.rvt
A510
CASEWORK
SECTIONS
NEW WORSHIP
CENTER
Checker
Author
06-10-2008
535-3581
A510 1" = 1'-0"
4 CW-BASE CABINET
A510 3" = 1'-0"
5 CW-TYPICAL CW DETAILS
A510 1" = 1'-0"
1 CW-TYP. BASE/WALL CAB. W/ SINK
1. PROVIDE ROUNDED 2" RADIUS OUTSIDE
CORNERS AT ALL COUNTERTOPS
2 CONTRACTOR TO PROVIDE SOLID WOOD BLOCKING
IN STUD SPACE AND PROVIDE ANCHOR THROUGH
GYPSUM WALLBOARD AND WOOD BLOCKING.
PLASTIC ANCHORS AND INSERTS TO BE AVOIDED.
3. PROVIDE PLASTIC LAMINATE TOE KICK AT ALL
CASEWORK WHERE APPLICABLE.
4. ALL MILLWORK, INCLUDING BACK PANELS, ARE TO BE
CONSTRUCTED OF 3/4" PLASTIC LAMINATE MATERIAL
AS INDICATED IN SECTIONS; UNLESS NOTED
OTHERWISE.
5. FASTENERS FOR KNEE BRACE SUPPORTS ARE TO BE
FINISHED CHROME HEADED SCREWS.
6. DRAWER CONSTRUCTION, MATERIALS AND JOINERY IS
TO BE PREMIUM GRADE PER AWI STANDARDS
7. ALL SURFACES, INCLUDING THOUSE CONCEALED
AFTER INSTALLATION ARE TO BE FINISHED PER
SPECIFICATION. MIN BACKER BK-20.
8. ALL CABINETS WITH DOORS TO RECEIVE LOCKS ARE
TO RECEIVE CYLINDER LOCKS AT EACH DOOR LEAF.
9. EXPOSED WALL CLEATS ARE TO BE PAINTED FINISH.
AT WORK SURFACES PROVIDE BEVELED CUT AND
HOLD BACK MIN. 4" FROM LEADING EDGE OF WORK
SURFACE.
10. 1" OVERHANG - TYPICAL AT COUNTERS WITH END
BASE CABINETS. UNLESS NOTED OTHERWISE.
11. SCRIBES AT CABINET BODY IS TO BE FLUSH WITH
BODY. SCRIBES/FILLERS AT DOORS AND DRAWER
FRONTS ARE TO BE FLUSH WITH DOOR OR DRAWER
FRONTS
12. DRAWERS ARE TO BE FULL DEPTH OF COUNTER;
UNLESS NOTED OTHERWISE.
13. CABINET INTERIORS ARE TO BE PER SPECIFICATION;
HPDL GP-28 (VERTICAL GRADE LAMINATE).
GENERAL CASEWORK NOTES
A510 1/2" = 1'-0"
6 CASEWORK ELEVATION-GREEN ROOM
A510 1/2" = 1'-0"
7 CASEWORK ELEVATION-STO. 012
4 PERMIT SET 04.25.08
A510 1" = 1'-0"
2 CW-OFFICE COUNTERTOP
A510 1" = 1'-0"
3 CW-SOUND BOOTH COUNTERTOP
6 ADDENDUM #3 05.23.08
10 PERMIT SET 06.10.08