Loading...
HomeMy WebLinkAboutA601MAX. 12" O.C. EPDM MEMBRANE RIGID INSULATION SEALANT 3" MIN.* CONTINUOUS ALUMINUM FLASHING BONDING ADHESIVE FASTENING PLATE SPLICING CEMENT LAP SEALANT EPDM MEMBRANE ROOF STRUCTURE MECHANICAL EQUIPMENT CURB EQUIPMENT CURB CLAMPING RING EPDM MEMBRANE WATER CUT-OFF MASTIC RIGID INSULATION ROOF STRUCTURE ROOF DRAIN ROOF DRAIN 3" 8" 3" 6" MEMBRANE 2x6 NON-COMBUSTIBLE INSULATION SEALANT MEMBRANE FASTENER 8"x12"x WALL DEPTH STAINLESS STEEL SCUPPER SLEEVE EPDM NON-REINFORCED MEMBRANE RIGID SEALANT WALL SYSTEM WALL WOOD NAILER ROOF STRUCTURE MEMBRANE NON-REINFORCED CONTINUE 4" PAST SCUPPER OPENING EPDM PRIMARY SCUPPER SYSTEM S.S. PERIMETER FRONT FLANGE SEALANT 5" MIN. WATER CUT-OFF MASTIC TERMINATION BAR BONDING ADHESIVE LAP SEALANT EPDM MEMBRANE TERMINATION BAR ANCHOR ALUMINUM COUNTERFLASHING CONSECUTIVE LENGTHS OF TERMINATION BAR. ALLOW 1/4" MIN. TO 1/2" MAX. (6 TO 13 mm) SPACING BETWEEN (6 - 13 mm) 1/4" MIN. - 1/2" MAX. EXTERIOR WALL SYSTEM HORIZONTAL MEMBRANE TERMINATION FLASHING ANCHOR MIN. 3" (75 mm) SPLICING CEMENT LAP SEALANT WATER CUT-OFF MASTIC FLASHING UNCURED ELASTOFORM INSULATION RIGID EPDM MEMBRANE TREATED 2x6 WOOD NAILER ANY FLEXIBLE PENETRATION "GOOSENECK" ROOF STRUCTURE FLEXIBLE PIPE (CONDUIT) FLASHING RIGID INSULATION NOTES: 1. TEMPERATURE OF METAL COLLAR MUST NOT EXCEED 180 F (82 C). MIN. 3" (75 mm) HEAT RESISTANT SEALANT STAINLESS STEEL RAIN HOOD TREATED 2x6 WOOD NAILER EPDM MEMBRANE METAL COLLAR BOILER FLUE 1/2" MIN. 1" MIN. UNCURED ELASTOFORM FLASHING LAP SEALANT SPLICING CEMENT (25 mm) HOT PIPE FLASHING PRECAST CONCRETE PANEL TRANSITION BETWEEN VERTICAL ROOFING TERMINATION PER DETAIL 5/A2.42 HORIZONTAL ROOFING TERMINATION PER DETAIL 6/A2.42 ALUM. COUNTER FLASHING (NOT INDICATED) PRECAST PARAPET AND METAL STUD PARAPET EXPOSED PRECAST CONCRETE PANEL PER DETAIL 11/A2.42 COPING TERMINATION TO ALIGN WITH FLASHING AT COPING TERMINATION (DETAIL 11/A2.42) PARAPET ROOFING TRANSITION LAP SEALANT ADHESIVE BONDING SURE-SEAL MEMBRANE EPDM ROOF TIGHT SEALED WATER- FLASHING TO BE METAL COUNTER- MEMBER STRUCTURAL ERECTED AROUND WOODEN CURB, WELDED PLATE, WATERTIGHT STRUCTURAL STEEL MEMBER TERMINATION ACCEPTABLE SEALANT WITH IN-SEAM MAX. 12" O.C. FASTENING PLATE SEAM ADHESIVE BONDING NAILER WOOD TREATED RIGID INSULATION MEMBRANE EPDM ROOF STEEL COLUMN PENETRATION (@ SCREEN WALL) NON-STAINING PRESSURE-SENSITIVE TAPE SEALANT WELD TUBING WRAP SQUARE MIN. 1-1/2" (40 TO 50 mm) FASTENER AND FASTENING PLATE, MAX. 12" O.C. 12" (300 mm) MAX. ACCEPTABLE INSULATION 6" WIDE REINFORCED MEMBRANE CUT-EDGE SEALANT 1-1/2" TO 2" 1" (25 mm) MIN. (APPROX.) REINFORCED MEMBRANE SQUARE TUBING WRAP OVERLAP ENTIRE WIDTH OF WELD WRAP AROUND PIPE FASTENING PLATES SQUARE TUBING BELOW PIPE WRAP FLANGE WELD MIN. 1-1/2" ALUMINUM COLLAR AND COLLAR STRAP NOT SHOWN NOTE: ALUM. COLLAR TUBE STEEL PIPE PENETRATION @ SCREEN WALL 4" MIN. CONTINOUS SEALANT COPING CONTINUED UP WALL ANCHOR COPING TO WALL SYSTEM TYPICAL ALUMINUM COPING TERMINATION AT WALL SYSTEM MIN. 4" CONTINUOUS WOOD BLOCKING CONTINOUS SEALANT CONTINOUS COUNTER FLASHING ANCHORDED TO WALL SYSTEM ROOFING MASTIC STAINLESS STEEL CLAMPING RING EPDM MEMBRANE APPROX. 1/2" WATER CUT-OFF MASTIC PRE-MOLDED PIPE SEAL RIGID INSULATION IN-SEAM SPLICING SEALANT CEMENT 1/2" TO 6-1/2" LAP SEALANT 1/2" (13 mm) VENT PIPE FLASHING WATER CUT-OFF MASTIC ROOF STRUCTURE TERMINATION BAR BONDING ADHESIVE LAP SEALANT EPDM MEMBRANE TERMINATION BAR FASTENER VERTICAL MEMBRANE TERMINATION Date: Scale Drawn By Checked By Project Number ARCHITECTURE PLANNING INTERIOR DESIGN STRUCTURAL ENGINEERING 424 East Fourth Street Cincinnati, Ohio 45202 w w w . c h a r c h i t e c t s . c o m tel: 513/241/4474 fax: 513/241/0081 ISSUANCES COMPUTER FILE 1400 West Dorothy Lane Dayton, Ohio 45409-1310 Tel: (937) 224-0861 Fax: (937) 224-5777 3417 South Sherman Drive Beech Grove, IN 46107 Tel: (317) 780-1555 Fax: (317) 780-6525 750 North Orleans, Suite 400 Chicago, IL 60610 Tel: (312) 944-8230 Fax: (312) 944-8297 117 East Washington Street, Suite 200 Indianapolis, IN 46204 Tel: (317) 637-2222 Fax: (317) 637-2260 1137 West Taylor St. Suite 316 Chicago, IL 60607 Tel: (312) 224-8460 Fax: (312) 224-8961 1025 N.Watery Ln. Brigham City, UT 84302 TEL: (453) 723-5000 FAX: (453) 538-5506 6622 Kingspointe Parkway Orlando, FL 33819 Tel: (407) 816-9400 Fax: (407) 816-9300 900145 E T T E L C O T T A B J . M . A R C H I T E C T . . NO STATE OF I N D I A N A D E R E T S I G E R No. Description Date 1 : 6 6/13/2008 11:09:22 AM C:\!!!Bryan\Revit\NVCLC-bd.rvt A601 ROOF DETAILS NEW WORSHIP CENTER Checker Author 06-10-2008 535-3581 A601 1 : 6 1 ROOF DETAIL-EQUIPMENT CURB A601 1 : 6 2 ROOF DETAIL-ROOF DRAIN A601 1 : 6 3 ROOF DETAIL-PRIMARY SCUPPER A601 1 : 6 5 ROOF DETAIL-HORIZONTAL MEMBRANE TERMINATION A601 1 : 6 6 ROOF DETAIL-FLEXPIPE FLASHING A601 1 : 6 7 ROOF DETAIL-HOTPIPE FLASHING A601 1 : 6 8 ROOF DETAIL-PARAPET ROOFING TRANSITION A601 1 : 6 9 ROOF DETAIL-STEEL COLUMN PENETRATION A601 1 : 6 10 ROOF DETAIL-TUBE STEEL PIPE PENETRATION A601 1 : 6 11 ROOF DETAIL-TYPICAL ALUMINUM COPING TERMINATION AT WALL A601 1 : 6 13 ROOF DETAIL-VENT PIPE FLASHING A601 1 : 6 14 ROOF DETAIL-VERTICAL TERMINATION BAR 4 PERMIT SET 04.25.08 5 ADDENDUM #2 05.16.08 9 ADDENDUM # 6 06.10.08 10 PERMIT SET 06.10.08