Loading...
HomeMy WebLinkAboutA702TYPE A1 (U.N.O.) ONE LAYER OF 5/8" GYPSUM WALLBOARD ON EACH SIDE OF 3-5/8" 20 GA. METAL STUDS @ 16" O.C. WITH 3" SOUND ATTENUATION BLANKETS IN STUD SPACE. EXTEND STUDS, BOARD, AND BLANKETS FULL HEIGHT TO DECK ABOVE. TYPE A2 ONE LAYER OF 5/8" GYPSUM WALLBOARD ON EACH SIDE OF 3-5/8" 20 GA. METAL STUDS @ 16" O.C. WITH 3" SOUND ATTENUATION BLANKETS IN STUD SAPCE. EXTEND STUDS, BOARD, AND SOUND BLANKETS TO 6" ABOVE FACE OF CEILING. PROVIDE BRACING AT TOP OF WALL AS REUIRED, BUT NOT LESS THAN 8'-0" O.C. TYPE A3 ONE LAYER OF 5/8" GYPSUM WALLBOARD ON ROOM SIDE OF 3-5/8" 20 GA. METAL STUDS @ 16" O.C. WITH 3" SOUND ATTENUATION BLANKET IN STUD SPACE. EXTEND STUDS, BOARD AND SOUND BLANKETS FULL HEIGHT TO DECK ABOVE. TYPE A4 ONE LAYER OF 5/8" GYPSUM WALLBOARD ON ROOM SIDE OF 3-5/8" 20 GA. METAL STUDS @ 16" O.C. WITH 3" SOUND ATTENUATION BLANKETS IN STUD SAPCE. EXTEND STUDS, BOARD, AND SOUND BLANKETS TO 6" ABOVE FACE OF CEILING. BRACE TOP OF WALL AS REQUIRED, BUT NOT LESS THAN 8'-0" O.C. TYPE A5 SAME AS TYPE A2 EXCEPT PROVIDE NO SOUND ATTENUATION BLANKETS. TYPE B1 ONE LAYER OF 5/8" GYPSUM WALLBOARD ON EACH SIDE OF 6" 20 GA. METAL STUDS @ 16" O.C. WITH 3" SOUND ATTENUATION BLANKETS IN STUD SPACE. EXTEND STUDS, BOARD, AND BLANKETS FULL HEIGHT TO DECK ABOVE. TYPE B2 ONE LAYER OF 5/8" GYPSUM WALLBOARD ON EACH SIDE OF 6" 20 GA. METAL STUDS @ 16" O.C. WITH 3" SOUND ATTENUATION BLANKETS IN STUD SPACE. EXTEND STUDS, BOARD, AND SOUND BLANKETS TO 6" ABOVE FACE OF CEILING. PROVIDE BRACING AT TOP OF WALL AS REUIRED, BUT NOT LESS THAN 8'-0" O.C. NOTES: 1. ALL INTERIOR PARTITIONS SHOWN ON PLANS ARE TO BE PARTITION TYPE A1, UNLESS NOTED OTHERWISE. 2. ALL PARTITIONS, STUDS, BOARD, SOUND ATTENUATION BLANKETS, MASONRY, etc.. TO EXTEND FROM TOP OF FLOOR SLAB TIGHT TO UNDERSIDE OF STRUCTURE ABOVE, UNLESS NOTED OTHERWISE. 3. ALL INTERIOR METAL STUD PARTITIONS ARE TO HAVE A 2 1/2" DEEP TOP TRACK FOR DEFLECTION COMPENSATION. HOLD GYPSUM WALLBOARD AND STEEL VERTICAL STUDS 1/2" FROM BOTTOM OF STRUCTURE ABOVE. DO NOT SCREW- ATTACH STEEL VERTICAL STUDS OR GYPSUM WALLBOARD TO TOP DEFLECTION TRACK. 6" 6" 6" 5/8" 3 5/8" 5/8" 5/8" 3 5/8" 5/8" 3 5/8" 5/8" 4 7/8" 4 1/4" 4 7/8" 3 5/8" 5/8" 4 1/4" 3 5/8" 5/8" 4 1/4" 5/8" 5/8" 3 5/8" 1" 3 5/8" 5/8" 5/8" 10 3/4" TYPE G1 TWO LAYER OF 5/8" GYPSUM WALLBOARD ON FINISH SIDE OF TWO BACK TO BACK 3-5/8" 20 GA. METAL STUDS WITH 1" AIR GAP @ 16" O.C. WITH 3" SOUND ATTENUATION BLANKETS IN STUD SPACE. EXTEND STUDS, BOARD, AND BLANKETS FULL HEIGHT TO DECK ABOVE. 7 1/4" 6 5/8" 5/8" 6" 5/8" 6" 5/8" 1" 6" 1/2" 7 1/2" TYPE F3 1 HOUR SHAFT WALL UL # U415 1 LAYER OF 1/2" TYPE "X" GYPSUM WALLBOARD ON ONE SIDE OF 6" 2O GA. METAL CH STUD AT 16" O.C. MAX., AND ONE LAYER OF 1" TYPE "X" GYPSUM LINER PANEL INSERTED WITHIN "H" PORTION OF "CH" STUD, AND 6" SOUND ATTENUATION BLANKETS IN STUD SPACE. EXTEND STUDS, BOARD, AND SOUND BLANKETS FULL HEIGHT TO DECK ABOVE. 5/8" 6" 5/8" 7 1/4" TYPE F2 1 HOUR RATED WALL UL# U419 PROVIDE TYPE "X" GYPSUM WALLBOARD FOR 1 HR UL RATING ON EACH SIDE OF 6" 20 GA. METAL STUDS @ 16" O.C. WITH 6" SOUND ATTENUATION BLANKETS IN STUD SPACE. EXTEND STUDS, BOARD, AND BLANKETS FULL HEIGHT TO DECK ABOVE. 5/8" 3 5/8" 5/8" 4 7/8" TYPE F1 1 HOUR RATED WALL UL# U419 PROVIDE TYPE "X" GYPSUM WALLBOARD FOR 1 HR UL RATING ON EACH SIDE OF 3 5/8" 20 GA. METAL STUDS @ 16" O.C. WITH 6" SOUND ATTENUATION BLANKETS IN STUD SPACE. EXTEND STUDS, BOARD, AND BLANKETS FULL HEIGHT TO DECK ABOVE. TYPE F4 1 HOUR SHAFT WALL UL # U415 1 LAYER OF 1/2" TYPE "X" GYPSUM WALLBOARD ON ONE SIDE OF 4" 2O GA. METAL CH STUD AT 16" O.C. MAX., AND ONE LAYER OF 1" TYPE "X" GYPSUM LINER PANEL INSERTED WITHIN "H" PORTION OF "CH" STUD, AND 6" SOUND ATTENUATION BLANKETS IN STUD SPACE. EXTEND STUDS, BOARD, AND SOUND BLANKETS FULL HEIGHT TO DECK ABOVE. 1" 3" 1/2" 4 1/2" 2 1/2" 5/8" 3 1/8" TYPE C1 ONE LAYER OF 5/8" GYPSUM WALLBOARD ON ROOM SIDE OF 2 1/2" 20 GA. METAL STUDS @ 16" O.C. WITH 2" SOUND ATTENUATION BLANKET IN STUD SPACE. EXTEND STUDS, BOARD AND SOUND BLANKETS FULL HEIGHT TO DECK ABOVE. TYPE D1 ONE LAYER OF 5/8" GYPSUM WALLBOARD ON ROOM SIDE OF 1 5/8" 20 GA. METAL STUDS TO EXISTING WALL OR COLUMNS @ 16" O.C. EXTEND STUDS, BOARD, AND SOUND BLANKETS TO 6" ABOVE FACE OF CEILING. 1 5/8" 5/8" 2 1/4" 6" 7/8" 5/8" 1 1/2" TYPE E1 ONE LAYER OF 5/8" GYPSUM WALLBOARD ON ROOM SIDE OF 1 5/8" 20 GA. METAL STUDS TO EXISTING WALL OR COLUMNS @ 16" O.C. EXTEND STUDS, BOARD, AND SOUND BLANKETS TO 6" ABOVE FACE OF CEILING. TYPE A6 SAME AS TYPE A3 EXCEPT PROVIDE NO SOUND ATTENUATION BLANKETS AND EXTEND STUDS AND BOARD TO DECK STAIR STRINGER OR LANDING ABOVE. 3 5/8" 5/8" 4 1/4" 1" 6" 1/2" 7 1/2" TYPE F6 2 HOUR RATED WALL UL # U495 2 LAYERS OF 5/8" TYPE "X" GYPSUM WALLBOARD ON EACH SIDE OF 3 5/8" 2O GA. METAL CH STUD AT 16" O.C. MAX., AND 3 5/8" SOUND ATTENUATION BLANKETS IN STUD SPACE. EXTEND STUDS, BOARD, AND SOUND BLANKETS FULL HEIGHT TO DECK ABOVE. TYPE F7 2 HOUR RATED WALL UL # U495 2 LAYERS OF 5/8" TYPE "X" GYPSUM WALLBOARD ON EACH SIDE OF 6" 2O GA. METAL CH STUD AT 16" O.C. MAX., AND 6" SOUND ATTENUATION BLANKETS IN STUD SPACE. EXTEND STUDS, BOARD, AND SOUND BLANKETS FULL HEIGHT TO DECK ABOVE. 1" 3" 1/2" 4 1/2" 8" 4" 8" 4" REFER TO REFLECTED CEILING PLAN HANGER WIRE AS SPECIFIED FOR SUSPENDED CEILING GRID SYSTEM; SECURE TO STRUCTURE ABOVE ARMSTRONG AXIUM PERIMETER TRIM ASSEMBLY CEILING ASSEMBLY AS INDICATED ON R.C.P. CEILING ASSEMBLY AS INDICATED ON R.C.P. REFER TO REFLECTED CEILING PLAN ARMSTRONG AXIUM PERIMETER TRIM ASSEMBLY CEILING ASSEMBLY AS INDICATED ON R.C.P. CEILING ASSEMBLY AS INDICATED ON R.C.P. FINISHED FLOOR UNDERSIDE OF STRUCTURE ABOVE REFER TO 0' - 11 1/2" R.C.P. REFER TO 1' - 11 1/2" R.C.P. FINISHED FLOOR AS SCHEDULED 5/8" TYPE 'X' GYPSUM WALLBOARD ON 3-5/8" 20GA MTL STUDS. CONTINUE WALLBOARD TO 6" ABOVE CEILING GRID. UNLESS SHOWN OTHERWISE 6" CEILING SYSTEM AS INDICATED ON REFLECTED CEILING PLAN PROVIDE 3 5/8" 20GA MTL STUD DIAGONAL BRACING AT 4'-0" O.C. SECURE TO STRUCTURE ABOVE UNDERSIDE OF DECK ABOVE METAL RUNNER CHANNEL CEILING SYSTEM AS INDICATED ON REFLECTED CEILING PLAN PROVIDE BOX-BEAM WELDED STUD CONSTRUCTION THROUGHOUT BULKHEAD 6" 6" 1' - 2" 1' - 4" 1' - 0" REFER TO R.C.P. REFER TO R.C.P. REFER TO R.C.P. SUSPENDED ACOUSTICAL CEILING GRID SYSTEM PER R.C.P. HANGER WIRE AS SPECIFIED FOR SUPENDED CEILING SYSTEM; SECURE TO STRUTURE ABOVE WELDED BOX-BEAM CONSTRUCTION AS REQUIRED PROVIDE 3-5/8" 20GA METAL STUD DIAGONAL BRACING AT 4'-0" OC SECURE TO STRUCTURE ABOVE 5/8" GYPSUM WALLBOARD ON BOTH SIDES OF 3-5/8" 20GA METAL STUDS AT 16" OC WITH SOUND ATTENUATION BLANKET. WALLBOARD SHALL CONTINUE TO 6" ABOVE CEILING SYSTEM AS SHOWN UNDERSIDE OF DECK/SLAB/ STRUCTURE ABOVE METAL RUNNER CHANNEL BOLTED TO STRUCTURE ABOVE LINE OF FINISHED FLOOR VARIES; 1' - 3"REFER TO RCP VARIES; 1' REFER - 1"TO RCP PARTITION AS SCHEDULED 5/8" GYPSUM WALLBOARD ON 3 5/8" 20GA METAL STUDS. CONTINUE WALLBOARD TO 6" ABOVE CEILING GRID. PAINT AS INDICATED PER FINISH SCHEDULE CEILING SYSTEM PER R.C.P. UNDERSIDE OF STRUCTURE ABOVE PROVIDE 3 5/8" 20GA MTL STUD DIAGONAL BRACING AT 4'-0" O.C. SECURE TO STRUCTURE ABOVE METAL RUNNER CHANNEL MASON INDUSTRIES TYPE WHR-4D NEOPRENE ISOLATOR (OWNER'S STRUCTURAL ENGINEER TO DETERMINE LOAD REQUIREMENTS MIN. 1" CLEAR MAINTAIN MINIMUM 18" AIR SPACE STRUCTURAL FRAMING AS REQUIRED (OWNER'S STRUCTURAL ENGINEER TO DETERMINE LOAD REQUIREMENTS TWO (2) LAYERS 5/8" THICK GYPSUM BOARD BACKED WITH 3-1/2" UNFACED FIBERGLASS INSULATION CONTINUOUS BEAD OF NON-HARDENING ACOUSTICAL SEALANT (ALL EDGES) 6" 1' - 2" 1' - 0" REFER TO R.C.P. REFER TO R.C.P. WELDED BOX-BEAM CONSTRUCTION AS REQUIRED PROVIDE 3-5/8" 20GA METAL STUD DIAGONAL BRACING AT 4'-0" OC SECURE TO STRUCTURE ABOVE 5/8" GYPSUM WALLBOARD ON BOTH SIDES OF 3-5/8" 20GA METAL STUDS AT 16" OC WITH SOUND ATTENUATION BLANKET. WALLBOARD SHALL CONTINUE TO 6" ABOVE CEILING SYSTEM AND TO UNDERSIDE OF DECK AS SHOWN UNDERSIDE OF DECK/SLAB/ STRUCTURE ABOVE METAL RUNNER CHANNEL BOLTED TO STRUCTURE ABOVE LINE OF FINISHED FLOOR HANGER WIRE AS SPECIFIED FOR SUPENDED CEILING SYSTEM; SECURE TO STRUTURE ABOVE VARIES; 1' - 3"REFER TO RCP VARIES; 1' REFER - 1"TO RCP PARTITION AS SCHEDULED 5/8" GYPSUM WALLBOARD ON 3 5/8" 20GA METAL STUDS. CONTINUE WALLBOARD TO 6" ABOVE CEILING GRID AND TO STRUCTURE ABOVE AS SHOWN. PAINT AS INDICATED PER FINISH SCHEDULE UNDERSIDE OF STRUCTURE ABOVE PROVIDE 3 5/8" 20GA MTL STUD DIAGONAL BRACING AT 4'-0" O.C. SECURE TO STRUCTURE ABOVE METAL RUNNER CHANNEL FINISH FLOOR 6" 6" 1' - 2" 1' - 4" 1' - 0" REFER TO R.C.P. REFER TO R.C.P. REFER TO R.C.P. SUSPENDED ACOUSTICAL CEILING GRID SYSTEM PER R.C.P. HANGER WIRE AS SPECIFIED FOR SUPENDED CEILING SYSTEM; SECURE TO STRUTURE ABOVE WELDED BOX-BEAM CONSTRUCTION AS REQUIRED PROVIDE 3-5/8" 20GA METAL STUD DIAGONAL BRACING AT 4'-0" OC SECURE TO STRUCTURE ABOVE 3-5/8" 20GA METAL STUDS AT 16" OC WITH SOUND ATTENUATION BLANKET UNDERSIDE OF DECK/SLAB/ STRUCTURE ABOVE METAL RUNNER CHANNEL BOLTED TO STRUCTURE ABOVE LINE OF FINISHED FLOOR VARIES 0' - 11" 5/8" GYPSUM BOARD ON BOTH SIDES OF SOFFIT. BOARD SHALL CONTINUE TO 6" ABOVE CEILING SYSTEM AS SHOWN 8 3/4" 9" PLATFORM FLOOR: 1/2" PAINTED PLYRON OVER 1" T&G PLYWOOD ADHERED TO CONC. DECK EXP. BOLT 2X FRAMING STAINED HARDWOOD PAINT-OUT BLACK 1/2" STAINED PLYWOOD VENEER (1/4" BLACK REVEALS AT 48" O.C.) FASTENED TO 1/2" FRT PLYWOOD WITH EXPOSED BLACK PAN-HEAD SCEWS OVER 1 5/8 METAL STUDS AT 16" O.C. FOUNDATION WALL 4" RUBBER BASE CARPETED CONC. FLOOR CURVED FACE PAINTED METAL CLIP ANGLE PAINTED WELDED WIRE FABRIC W/TOP AND BOTTOM EDGE BAND 2" SLAB OVERLAP 6" X 3'-2" PRECAST PLANK (3'-6" @ FRONT ROW) 8" @ LOWER BALCONY 1' - 3" @ UPPER BALCONY CAULK CURVED FACE PAINTED 1" C-SHAPE EDGE BAND PAINTED 1" C- SHAPE EDGE BAND 3/4" PAINTED MDF ON FRONT FACE AND PANEL ENDS 7/8" HAT CHANNEL GRID @ 2'-0" MAX SPACING 3" MAINTAIN 3" PERIMETER BETWEEN EDGE AND HAT CHANNEL GRID 1 5/8" SCHEDULED PARTITION 3/4" PAINTED MDF ON FRONT FACE AND PANEL ENDS 7/8" HAT CHANNEL GRID ON NON-CONT. FRT WD. BLOCKING @ 2'-0" MAX SPACING 3" MAINTAIN 3" PERIMETER BETWEEN EDGE AND HAT CHANNEL GRID 3 1/8" PAINTED BLACK FULL PERIMETER FUTURE ACOUSTIC PANEL ON "2" CLIPS SCHEDULED PARTITION 3/4" PAINTED MDF ON FRONT FACE AND PANEL ENDS 7/8" HAT CHANNEL GRID ON NON-CONT. FRT WD. BLOCKING @ 2'-0" MAX SPACING MAINTAIN 3" PERIMETER BETWEEN EDGE AND HAT CHANNEL GRID PAINTED BLACK FULL PERIMETER FUTURE ACOUSTIC PANEL ON "2" CLIPS SCHEDULED PARTITION 3/4" PAINTED MDF ON FRONT FACE AND PANEL ENDS 7/8" HAT CHANNEL GRID @ 2'-0" MAX SPACING 3" 3 1/8" 3'-0" 9" 1'-6" 1'-0" 2'-6" 7'-6" DIAGONAL BRACING @ MAX. 4'-0" O.C. 3 5/8" MTL. STUDS @ 16" O.C. SUSPENDED FROM BEAM ABOVE SUSPENDED CEILING ABOVE SERVICE AREA 5/8" GYPSUM BOARD (CURVED PLANE) 5/8" GYPSUM BOARD CORNER BEAD (TYP.) 5/8" GYPSUM BOARD (CURVED PLANE) 3 5/8" MTL. STUD OUTRIGGERS @ 16" O.C. LIGHT FIXTURE 1/2" THREADED ROD WITH BRUSHED ALUM. SLEEVE, TYP. OF 4. ANCHORED TO STEEL FRAMED STRUCTURE ABOVE EXISTING FINISHED CEILING 2"x8" STEEL TUBE, ROLLED OR FACETED TO NEST WITHIN CURVED, HUNG SOFFIT Date: Scale Drawn By Checked By Project Number ARCHITECTURE PLANNING INTERIOR DESIGN STRUCTURAL ENGINEERING 424 East Fourth Street Cincinnati, Ohio 45202 w w w . c h a r c h i t e c t s . c o m tel: 513/241/4474 fax: 513/241/0081 ISSUANCES COMPUTER FILE 1400 West Dorothy Lane Dayton, Ohio 45409-1310 Tel: (937) 224-0861 Fax: (937) 224-5777 3417 South Sherman Drive Beech Grove, IN 46107 Tel: (317) 780-1555 Fax: (317) 780-6525 750 North Orleans, Suite 400 Chicago, IL 60610 Tel: (312) 944-8230 Fax: (312) 944-8297 117 East Washington Street, Suite 200 Indianapolis, IN 46204 Tel: (317) 637-2222 Fax: (317) 637-2260 1137 West Taylor St. Suite 316 Chicago, IL 60607 Tel: (312) 224-8460 Fax: (312) 224-8961 1025 N.Watery Ln. Brigham City, UT 84302 TEL: (453) 723-5000 FAX: (453) 538-5506 6622 Kingspointe Parkway Orlando, FL 33819 Tel: (407) 816-9400 Fax: (407) 816-9300 900145 E T T E L C O T T A B J . M . A R C H I T E C T . . NO STATE OF I N D I A N A D E R E T S I G E R No. Description Date As indicated 6/13/2008 11:11:20 AM C:\!!!Bryan\Revit\NVCLC-bd.rvt A702 PARTITION SCHEDULE, PARTITION DETAILS, RCP DETAILS NEW WORSHIP CENTER Checker KJ 06-10-2008 535-3581 3 CD 50% 03.14.08 PARTITION SCHEDULE 4 PERMIT SET 04.25.08 A702 1" = 1'-0" 1 DTL-CEILING CLOUD DETAIL A702 1" = 1'-0" 2 DTL-CORRIDOR CEILING TRANSITION A702 1" = 1'-0" 3 DTL-TYP. BULKHEAD DETAIL A702 1" = 1'-0" 4 DTL-TYP. SOFFIT DETAIL A702 1" = 1'-0" 7 DTL-SOUND ISOLATING CEILING ASSEMBLY A702 1" = 1'-0" 5 DTL BULKHEAD - EXPOSED STRUCT A702 1" = 1'-0" 6 DTL SOFFIT-EXPOSED STRUCT A702 1" = 1'-0" 8 DTL-SOFFIT DETAIL 5 ADDENDUM #2 05.16.08 2 A702 1" = 1'-0" 9 DTL-SECTION-STAGE A702 1 1/2" = 1'-0" 10 DTL- PRECAST CONCRETE PLANK INFILL DETAIL A702 1 1/2" = 1'-0" 11 DTL- AUDITORIUM SIDE WALL DETAIL A702 1 1/2" = 1'-0" 12 DTL- AUDITORIUM SIDE WALL DETAIL 2 A702 1 1/2" = 1'-0" 13 DTL- AUDITORIUM SIDE WALL DETAIL 3 A702 1 1/2" = 1'-0" 14 SOFFIT DETAIL AT CAPSTONE 6 ADDENDUM #3 05.23.08 10 PERMIT SET 06.10.08