HomeMy WebLinkAboutA702TYPE A1 (U.N.O.)
ONE LAYER OF 5/8"
GYPSUM WALLBOARD ON
EACH SIDE OF 3-5/8" 20 GA.
METAL STUDS @ 16" O.C.
WITH 3" SOUND
ATTENUATION BLANKETS
IN STUD SPACE. EXTEND
STUDS, BOARD, AND
BLANKETS FULL HEIGHT
TO DECK ABOVE.
TYPE A2
ONE LAYER OF 5/8" GYPSUM
WALLBOARD ON EACH SIDE
OF 3-5/8" 20 GA. METAL
STUDS @ 16" O.C. WITH 3"
SOUND ATTENUATION
BLANKETS IN STUD SAPCE.
EXTEND STUDS, BOARD, AND
SOUND BLANKETS TO 6"
ABOVE FACE OF CEILING.
PROVIDE BRACING AT TOP OF
WALL AS REUIRED, BUT NOT
LESS THAN 8'-0" O.C.
TYPE A3
ONE LAYER OF 5/8" GYPSUM
WALLBOARD ON ROOM SIDE
OF 3-5/8" 20 GA. METAL
STUDS @ 16" O.C. WITH 3"
SOUND ATTENUATION
BLANKET IN STUD SPACE.
EXTEND STUDS, BOARD AND
SOUND BLANKETS FULL
HEIGHT TO DECK ABOVE.
TYPE A4
ONE LAYER OF 5/8"
GYPSUM WALLBOARD ON
ROOM SIDE OF 3-5/8" 20
GA. METAL STUDS @ 16"
O.C. WITH 3" SOUND
ATTENUATION BLANKETS
IN STUD SAPCE. EXTEND
STUDS, BOARD, AND
SOUND BLANKETS TO 6"
ABOVE FACE OF CEILING.
BRACE TOP OF WALL AS
REQUIRED, BUT NOT LESS
THAN 8'-0" O.C.
TYPE A5
SAME AS TYPE A2 EXCEPT
PROVIDE NO SOUND
ATTENUATION BLANKETS.
TYPE B1
ONE LAYER OF 5/8"
GYPSUM WALLBOARD ON
EACH SIDE OF 6" 20 GA.
METAL STUDS @ 16" O.C.
WITH 3" SOUND
ATTENUATION BLANKETS
IN STUD SPACE. EXTEND
STUDS, BOARD, AND
BLANKETS FULL HEIGHT
TO DECK ABOVE.
TYPE B2
ONE LAYER OF 5/8"
GYPSUM WALLBOARD ON
EACH SIDE OF 6" 20 GA.
METAL STUDS @ 16" O.C.
WITH 3" SOUND
ATTENUATION BLANKETS IN
STUD SPACE. EXTEND
STUDS, BOARD, AND
SOUND BLANKETS TO 6"
ABOVE FACE OF CEILING.
PROVIDE BRACING AT TOP
OF WALL AS REUIRED, BUT
NOT LESS THAN 8'-0" O.C.
NOTES:
1. ALL INTERIOR PARTITIONS SHOWN ON
PLANS ARE TO BE PARTITION TYPE A1,
UNLESS NOTED OTHERWISE.
2. ALL PARTITIONS, STUDS, BOARD,
SOUND ATTENUATION BLANKETS,
MASONRY, etc.. TO EXTEND FROM TOP
OF FLOOR SLAB TIGHT TO UNDERSIDE
OF STRUCTURE ABOVE, UNLESS
NOTED OTHERWISE.
3. ALL INTERIOR METAL STUD
PARTITIONS ARE TO HAVE A 2 1/2"
DEEP TOP TRACK FOR DEFLECTION
COMPENSATION. HOLD GYPSUM
WALLBOARD AND STEEL VERTICAL
STUDS 1/2" FROM BOTTOM OF
STRUCTURE ABOVE. DO NOT SCREW-
ATTACH STEEL VERTICAL STUDS OR
GYPSUM WALLBOARD TO TOP
DEFLECTION TRACK.
6"
6"
6"
5/8" 3 5/8" 5/8"
5/8" 3 5/8" 5/8"
3 5/8" 5/8"
4 7/8" 4 1/4"
4 7/8"
3 5/8" 5/8"
4 1/4"
3 5/8" 5/8"
4 1/4"
5/8"
5/8"
3 5/8" 1" 3 5/8"
5/8"
5/8"
10 3/4"
TYPE G1
TWO LAYER OF 5/8"
GYPSUM WALLBOARD ON
FINISH SIDE OF TWO BACK
TO BACK 3-5/8" 20 GA.
METAL STUDS WITH 1" AIR
GAP @ 16" O.C. WITH 3"
SOUND ATTENUATION
BLANKETS IN STUD
SPACE. EXTEND STUDS,
BOARD, AND BLANKETS
FULL HEIGHT TO DECK
ABOVE.
7 1/4" 6 5/8"
5/8" 6" 5/8" 6" 5/8" 1" 6" 1/2"
7 1/2"
TYPE F3
1 HOUR SHAFT WALL
UL # U415
1 LAYER OF 1/2" TYPE "X"
GYPSUM WALLBOARD ON
ONE SIDE OF 6" 2O GA.
METAL CH STUD AT 16" O.C.
MAX., AND ONE LAYER OF
1" TYPE "X" GYPSUM LINER
PANEL INSERTED WITHIN
"H" PORTION OF "CH" STUD,
AND 6" SOUND
ATTENUATION BLANKETS IN
STUD SPACE. EXTEND
STUDS, BOARD, AND
SOUND BLANKETS FULL
HEIGHT TO DECK ABOVE.
5/8" 6" 5/8"
7 1/4"
TYPE F2
1 HOUR RATED WALL
UL# U419
PROVIDE TYPE "X" GYPSUM
WALLBOARD FOR 1 HR UL
RATING ON EACH SIDE OF
6" 20 GA. METAL STUDS @
16" O.C. WITH 6" SOUND
ATTENUATION BLANKETS IN
STUD SPACE. EXTEND
STUDS, BOARD, AND
BLANKETS FULL HEIGHT TO
DECK ABOVE.
5/8" 3 5/8" 5/8"
4 7/8"
TYPE F1
1 HOUR RATED WALL
UL# U419
PROVIDE TYPE "X" GYPSUM
WALLBOARD FOR 1 HR UL
RATING ON EACH SIDE OF 3
5/8" 20 GA. METAL STUDS @
16" O.C. WITH 6" SOUND
ATTENUATION BLANKETS IN
STUD SPACE. EXTEND
STUDS, BOARD, AND
BLANKETS FULL HEIGHT TO
DECK ABOVE.
TYPE F4
1 HOUR SHAFT WALL
UL # U415
1 LAYER OF 1/2" TYPE "X"
GYPSUM WALLBOARD ON
ONE SIDE OF 4" 2O GA.
METAL CH STUD AT 16" O.C.
MAX., AND ONE LAYER OF
1" TYPE "X" GYPSUM LINER
PANEL INSERTED WITHIN
"H" PORTION OF "CH" STUD,
AND 6" SOUND
ATTENUATION BLANKETS IN
STUD SPACE. EXTEND
STUDS, BOARD, AND
SOUND BLANKETS FULL
HEIGHT TO DECK ABOVE.
1" 3" 1/2"
4 1/2"
2 1/2" 5/8"
3 1/8"
TYPE C1
ONE LAYER OF 5/8" GYPSUM
WALLBOARD ON ROOM
SIDE OF 2 1/2" 20 GA.
METAL STUDS @ 16" O.C.
WITH 2" SOUND
ATTENUATION BLANKET IN
STUD SPACE. EXTEND
STUDS, BOARD AND SOUND
BLANKETS FULL HEIGHT TO
DECK ABOVE.
TYPE D1
ONE LAYER OF 5/8" GYPSUM
WALLBOARD ON ROOM SIDE
OF 1 5/8" 20 GA. METAL
STUDS TO EXISTING WALL OR
COLUMNS @ 16" O.C. EXTEND
STUDS, BOARD, AND SOUND
BLANKETS TO 6" ABOVE
FACE OF CEILING.
1 5/8" 5/8"
2 1/4"
6"
7/8" 5/8"
1 1/2"
TYPE E1
ONE LAYER OF 5/8"
GYPSUM WALLBOARD ON
ROOM SIDE OF 1 5/8" 20 GA.
METAL STUDS TO EXISTING
WALL OR COLUMNS @ 16"
O.C. EXTEND STUDS,
BOARD, AND SOUND
BLANKETS TO 6" ABOVE
FACE OF CEILING.
TYPE A6
SAME AS TYPE A3 EXCEPT
PROVIDE NO SOUND
ATTENUATION BLANKETS
AND EXTEND STUDS AND
BOARD TO DECK STAIR
STRINGER OR LANDING
ABOVE.
3 5/8" 5/8"
4 1/4"
1" 6" 1/2"
7 1/2"
TYPE F6
2 HOUR RATED WALL
UL # U495
2 LAYERS OF 5/8" TYPE "X"
GYPSUM WALLBOARD ON
EACH SIDE OF 3 5/8" 2O
GA. METAL CH STUD AT 16"
O.C. MAX., AND 3 5/8"
SOUND ATTENUATION
BLANKETS IN STUD SPACE.
EXTEND STUDS, BOARD,
AND SOUND BLANKETS
FULL HEIGHT TO DECK
ABOVE.
TYPE F7
2 HOUR RATED WALL
UL # U495
2 LAYERS OF 5/8" TYPE "X"
GYPSUM WALLBOARD ON
EACH SIDE OF 6" 2O GA.
METAL CH STUD AT 16"
O.C. MAX., AND 6" SOUND
ATTENUATION BLANKETS
IN STUD SPACE. EXTEND
STUDS, BOARD, AND
SOUND BLANKETS FULL
HEIGHT TO DECK ABOVE.
1" 3" 1/2"
4 1/2"
8"
4"
8"
4"
REFER TO REFLECTED
CEILING PLAN
HANGER WIRE AS
SPECIFIED FOR
SUSPENDED CEILING
GRID SYSTEM; SECURE
TO STRUCTURE ABOVE
ARMSTRONG AXIUM
PERIMETER TRIM ASSEMBLY
CEILING ASSEMBLY AS
INDICATED ON R.C.P.
CEILING ASSEMBLY AS
INDICATED ON R.C.P.
REFER TO REFLECTED
CEILING PLAN
ARMSTRONG AXIUM
PERIMETER TRIM ASSEMBLY
CEILING ASSEMBLY AS
INDICATED ON R.C.P.
CEILING ASSEMBLY AS
INDICATED ON R.C.P.
FINISHED FLOOR
UNDERSIDE OF
STRUCTURE ABOVE
REFER TO 0' - 11 1/2" R.C.P.
REFER TO 1' - 11 1/2" R.C.P.
FINISHED FLOOR AS
SCHEDULED
5/8" TYPE 'X' GYPSUM
WALLBOARD ON 3-5/8" 20GA
MTL STUDS. CONTINUE
WALLBOARD TO 6" ABOVE
CEILING GRID. UNLESS
SHOWN OTHERWISE
6"
CEILING SYSTEM AS
INDICATED ON REFLECTED
CEILING PLAN
PROVIDE 3 5/8" 20GA MTL
STUD DIAGONAL BRACING AT
4'-0" O.C. SECURE TO
STRUCTURE ABOVE
UNDERSIDE OF DECK ABOVE METAL RUNNER CHANNEL
CEILING SYSTEM AS
INDICATED ON REFLECTED
CEILING PLAN
PROVIDE BOX-BEAM WELDED
STUD CONSTRUCTION
THROUGHOUT BULKHEAD
6"
6"
1' - 2"
1' - 4"
1' - 0"
REFER TO R.C.P.
REFER TO R.C.P.
REFER TO R.C.P.
SUSPENDED ACOUSTICAL
CEILING GRID SYSTEM PER
R.C.P.
HANGER WIRE AS SPECIFIED
FOR SUPENDED CEILING
SYSTEM; SECURE TO
STRUTURE ABOVE
WELDED BOX-BEAM
CONSTRUCTION AS REQUIRED
PROVIDE 3-5/8" 20GA METAL
STUD DIAGONAL BRACING
AT 4'-0" OC SECURE TO
STRUCTURE ABOVE
5/8" GYPSUM WALLBOARD ON
BOTH SIDES OF 3-5/8" 20GA
METAL STUDS AT 16" OC WITH
SOUND ATTENUATION
BLANKET. WALLBOARD SHALL
CONTINUE TO 6" ABOVE
CEILING SYSTEM AS SHOWN
UNDERSIDE OF DECK/SLAB/
STRUCTURE ABOVE
METAL RUNNER CHANNEL
BOLTED TO STRUCTURE
ABOVE
LINE OF FINISHED FLOOR
VARIES; 1' - 3"REFER
TO RCP
VARIES; 1' REFER - 1"TO RCP
PARTITION AS
SCHEDULED
5/8" GYPSUM WALLBOARD ON 3 5/8"
20GA METAL STUDS. CONTINUE
WALLBOARD TO 6" ABOVE CEILING
GRID. PAINT AS INDICATED PER
FINISH SCHEDULE
CEILING SYSTEM PER
R.C.P.
UNDERSIDE OF STRUCTURE
ABOVE
PROVIDE 3 5/8" 20GA MTL STUD
DIAGONAL BRACING AT 4'-0" O.C.
SECURE TO STRUCTURE ABOVE
METAL
RUNNER
CHANNEL
MASON INDUSTRIES TYPE WHR-4D
NEOPRENE ISOLATOR (OWNER'S
STRUCTURAL ENGINEER TO DETERMINE
LOAD REQUIREMENTS
MIN. 1" CLEAR
MAINTAIN MINIMUM
18" AIR SPACE
STRUCTURAL FRAMING AS REQUIRED (OWNER'S
STRUCTURAL ENGINEER TO DETERMINE LOAD
REQUIREMENTS
TWO (2) LAYERS 5/8" THICK GYPSUM BOARD BACKED
WITH 3-1/2" UNFACED FIBERGLASS INSULATION
CONTINUOUS BEAD OF
NON-HARDENING ACOUSTICAL
SEALANT (ALL EDGES)
6"
1' - 2"
1' - 0"
REFER TO R.C.P.
REFER TO R.C.P.
WELDED BOX-BEAM
CONSTRUCTION AS REQUIRED
PROVIDE 3-5/8" 20GA METAL
STUD DIAGONAL BRACING
AT 4'-0" OC SECURE TO
STRUCTURE ABOVE
5/8" GYPSUM WALLBOARD ON
BOTH SIDES OF 3-5/8" 20GA
METAL STUDS AT 16" OC WITH
SOUND ATTENUATION BLANKET.
WALLBOARD SHALL CONTINUE
TO 6" ABOVE CEILING SYSTEM
AND TO UNDERSIDE OF DECK AS
SHOWN
UNDERSIDE OF DECK/SLAB/
STRUCTURE ABOVE
METAL RUNNER CHANNEL
BOLTED TO STRUCTURE
ABOVE
LINE OF FINISHED FLOOR
HANGER WIRE AS SPECIFIED
FOR SUPENDED CEILING
SYSTEM; SECURE TO
STRUTURE ABOVE
VARIES; 1' - 3"REFER
TO RCP
VARIES; 1' REFER - 1"TO RCP
PARTITION AS
SCHEDULED
5/8" GYPSUM WALLBOARD ON 3 5/8"
20GA METAL STUDS. CONTINUE
WALLBOARD TO 6" ABOVE CEILING
GRID AND TO STRUCTURE ABOVE
AS SHOWN. PAINT AS INDICATED
PER FINISH SCHEDULE
UNDERSIDE OF STRUCTURE
ABOVE
PROVIDE 3 5/8" 20GA MTL STUD
DIAGONAL BRACING AT 4'-0" O.C.
SECURE TO STRUCTURE ABOVE
METAL
RUNNER
CHANNEL
FINISH FLOOR
6"
6"
1' - 2"
1' - 4"
1' - 0"
REFER TO R.C.P.
REFER TO R.C.P.
REFER TO R.C.P.
SUSPENDED ACOUSTICAL
CEILING GRID SYSTEM PER
R.C.P.
HANGER WIRE AS SPECIFIED
FOR SUPENDED CEILING
SYSTEM; SECURE TO
STRUTURE ABOVE
WELDED BOX-BEAM
CONSTRUCTION AS REQUIRED
PROVIDE 3-5/8" 20GA METAL
STUD DIAGONAL BRACING
AT 4'-0" OC SECURE TO
STRUCTURE ABOVE
3-5/8" 20GA METAL STUDS AT 16"
OC WITH SOUND ATTENUATION
BLANKET
UNDERSIDE OF DECK/SLAB/
STRUCTURE ABOVE
METAL RUNNER CHANNEL
BOLTED TO STRUCTURE
ABOVE
LINE OF FINISHED FLOOR
VARIES 0' - 11"
5/8" GYPSUM BOARD ON BOTH
SIDES OF SOFFIT. BOARD
SHALL CONTINUE TO 6" ABOVE
CEILING SYSTEM AS SHOWN
8 3/4"
9"
PLATFORM FLOOR:
1/2" PAINTED PLYRON
OVER 1" T&G
PLYWOOD ADHERED
TO CONC. DECK
EXP. BOLT
2X FRAMING
STAINED
HARDWOOD
PAINT-OUT BLACK
1/2" STAINED PLYWOOD
VENEER (1/4" BLACK REVEALS
AT 48" O.C.) FASTENED TO 1/2"
FRT PLYWOOD WITH EXPOSED
BLACK PAN-HEAD SCEWS OVER
1 5/8 METAL STUDS AT 16" O.C.
FOUNDATION WALL
4" RUBBER BASE
CARPETED CONC. FLOOR
CURVED FACE
PAINTED METAL
CLIP ANGLE
PAINTED WELDED WIRE
FABRIC W/TOP AND BOTTOM EDGE
BAND
2" SLAB OVERLAP
6" X 3'-2" PRECAST PLANK
(3'-6" @ FRONT ROW)
8" @ LOWER BALCONY 1' - 3" @ UPPER BALCONY
CAULK
CURVED
FACE
PAINTED 1" C-SHAPE EDGE BAND
PAINTED 1" C-
SHAPE EDGE BAND
3/4" PAINTED MDF
ON FRONT FACE
AND PANEL ENDS
7/8" HAT CHANNEL
GRID @
2'-0" MAX SPACING
3"
MAINTAIN 3"
PERIMETER BETWEEN
EDGE AND HAT CHANNEL
GRID
1 5/8"
SCHEDULED PARTITION
3/4" PAINTED MDF
ON FRONT FACE
AND PANEL ENDS
7/8" HAT CHANNEL
GRID ON NON-CONT.
FRT WD. BLOCKING @
2'-0" MAX SPACING
3"
MAINTAIN 3"
PERIMETER BETWEEN
EDGE AND HAT CHANNEL
GRID
3 1/8"
PAINTED BLACK
FULL PERIMETER
FUTURE ACOUSTIC PANEL
ON "2" CLIPS
SCHEDULED PARTITION 3/4" PAINTED MDF
ON FRONT FACE
AND PANEL ENDS
7/8" HAT CHANNEL
GRID ON NON-CONT.
FRT WD. BLOCKING @
2'-0" MAX SPACING
MAINTAIN 3"
PERIMETER BETWEEN
EDGE AND HAT CHANNEL
GRID
PAINTED BLACK
FULL PERIMETER
FUTURE ACOUSTIC PANEL
ON "2" CLIPS
SCHEDULED PARTITION
3/4" PAINTED MDF
ON FRONT FACE
AND PANEL ENDS
7/8" HAT CHANNEL
GRID @ 2'-0" MAX
SPACING
3"
3 1/8"
3'-0"
9"
1'-6"
1'-0"
2'-6"
7'-6"
DIAGONAL BRACING
@ MAX. 4'-0" O.C.
3 5/8" MTL. STUDS
@ 16" O.C.
SUSPENDED FROM
BEAM ABOVE
SUSPENDED CEILING
ABOVE SERVICE AREA
5/8" GYPSUM BOARD
(CURVED PLANE)
5/8" GYPSUM BOARD CORNER BEAD (TYP.)
5/8" GYPSUM BOARD
(CURVED PLANE)
3 5/8" MTL. STUD
OUTRIGGERS @ 16" O.C.
LIGHT FIXTURE
1/2" THREADED ROD
WITH BRUSHED ALUM.
SLEEVE, TYP. OF 4.
ANCHORED TO STEEL
FRAMED STRUCTURE
ABOVE EXISTING
FINISHED CEILING
2"x8" STEEL TUBE, ROLLED
OR FACETED TO NEST
WITHIN CURVED, HUNG SOFFIT
Date: Scale
Drawn By
Checked By
Project
Number
ARCHITECTURE
PLANNING
INTERIOR DESIGN
STRUCTURAL ENGINEERING
424 East Fourth Street
Cincinnati, Ohio 45202
w w w . c h a r c h i t e c t s . c o m
tel: 513/241/4474 fax: 513/241/0081
ISSUANCES
COMPUTER FILE
1400 West Dorothy Lane
Dayton, Ohio 45409-1310
Tel: (937) 224-0861
Fax: (937) 224-5777
3417 South Sherman Drive
Beech Grove, IN 46107
Tel: (317) 780-1555
Fax: (317) 780-6525
750 North Orleans, Suite 400
Chicago, IL 60610
Tel: (312) 944-8230
Fax: (312) 944-8297
117 East Washington
Street, Suite 200
Indianapolis, IN 46204
Tel: (317) 637-2222
Fax: (317) 637-2260
1137 West Taylor St.
Suite 316
Chicago, IL 60607
Tel: (312) 224-8460
Fax: (312) 224-8961
1025 N.Watery Ln.
Brigham City, UT 84302
TEL: (453) 723-5000
FAX: (453) 538-5506
6622 Kingspointe
Parkway
Orlando, FL 33819
Tel: (407) 816-9400
Fax: (407) 816-9300
900145
E
T
T
E
L
C
O
T
T
A
B
J
.
M
.
A
R
C
H
I
T
E
C
T
. .
NO
STATE OF
I
N
D
I
A
N
A
D
E
R
E
T
S
I
G
E
R
No. Description Date
As indicated
6/13/2008 11:11:20 AM
C:\!!!Bryan\Revit\NVCLC-bd.rvt
A702
PARTITION
SCHEDULE,
PARTITION DETAILS,
RCP DETAILS
NEW WORSHIP
CENTER
Checker
KJ
06-10-2008
535-3581
3 CD 50% 03.14.08
PARTITION SCHEDULE
4 PERMIT SET 04.25.08
A702 1" = 1'-0"
1 DTL-CEILING CLOUD DETAIL
A702 1" = 1'-0"
2 DTL-CORRIDOR CEILING TRANSITION
A702 1" = 1'-0"
3 DTL-TYP. BULKHEAD DETAIL
A702 1" = 1'-0"
4 DTL-TYP. SOFFIT DETAIL
A702 1" = 1'-0"
7 DTL-SOUND ISOLATING CEILING ASSEMBLY
A702 1" = 1'-0"
5 DTL BULKHEAD - EXPOSED STRUCT
A702 1" = 1'-0"
6 DTL SOFFIT-EXPOSED STRUCT
A702 1" = 1'-0"
8 DTL-SOFFIT DETAIL
5 ADDENDUM #2 05.16.08
2
A702 1" = 1'-0"
9 DTL-SECTION-STAGE
A702 1 1/2" = 1'-0"
10 DTL- PRECAST CONCRETE PLANK INFILL DETAIL
A702 1 1/2" = 1'-0"
11 DTL- AUDITORIUM SIDE WALL DETAIL
A702 1 1/2" = 1'-0"
12 DTL- AUDITORIUM SIDE WALL DETAIL 2
A702 1 1/2" = 1'-0"
13 DTL- AUDITORIUM SIDE WALL DETAIL 3
A702 1 1/2" = 1'-0"
14 SOFFIT DETAIL AT CAPSTONE
6 ADDENDUM #3 05.23.08
10 PERMIT SET 06.10.08