HomeMy WebLinkAboutE001 - LIGHTING FIXTURE SCHEDULE, LEGEND & INDEX OF DRAWINGSMOTORS, STARTERS, DISCONNECTS & CONTROLS LIGHTING FIXTURES LEGEND NORMAL/EMERGENCY CIRCUIT SCHEDULE GENERAL NOTES WP/GF J H1 a B1 b LIGHTING FIXTURE; CAPITAL LETTER DENOTES FIXTURE TYPE. LOWER CASE LETTER DENOTES SWITCHING ARRANGEMENT. EXIT LIGHTING FIXTURE. COORDINATE EXIT SIGN ARROWS WITH ARCHITECTURAL EGRESS PATHS - SEE ARCHITECTURAL DRAWINGS. ELECTRICAL CONNECTION REQUIRED. ~ 123 ROOM NUMBER. 2 DETAIL NOTE SYMBOL - APPLIES ONLY TO DETAIL ON WHICH NOTE IS SHOWN. 3 NOTE SYMBOL - APPLIES ONLY TO SHEET ON WHICH NOTE IS SHOWN. GROUND FAULT FEED THRU GFFT CIRCUIT CKT MOUNTING HEIGHT TO CENTERLINE OF ITEM UNLESS INDICATED OTHERWISE ON MH DRAWINGS. ABOVE FINISHED FLOOR - TO BOTTOM OF ITEM UNLESS INDICATED OTHERWISE ON DRAWINGS AFF EXISTING E SURFACE MOUNTED S EMERGENCY EM WEATHERPROOF WP NOT IN ELECTRICAL CONTRACT N.I.E.C. EQUIPMENT SUPPLIER E.S. GENERAL CONTRACTOR G.C. FIRE PROTECTION CONTRACTOR F.P.C. PLUMBING CONTRACTOR P.C. HVAC CONTRACTOR H.C. ELECTRICAL CONTRACTOR E.C. FOUR-WAY WALL SWITCH (46" M.H.). 4 THREE-WAY WALL SWITCH (46" M.H.). 3 SINGLE POLE WALL SWITCH (46" M.H.). MOTOR STARTER. DISCONNECT SWITCH. 20A-125V WEATHERPROOF DUPLEX RECEPTACLE, NEMA 5-20R, WITH GROUND FAULT CIRCUIT INTERRUPTER (18" M.H.), WITH TAYMAC #20310 STANDARD COVER, VERTICAL MOUNT. 20A-125V DUPLEX RECEPTACLE, NEMA 5-20R. (46" M.H.). 20A-125V DOUBLE DUPLEX RECEPTACLE. NEMA 5-20R, (18" M.H.) TWO-GANG ASSEMBLY. 20A-125V DUPLEX RECEPTACLE, NEMA 5-20R (18" M.H.). 20A-125V SINGLE RECEPTACLE, NEMA 5-20R (18" M.H.). JUNCTION BOX. WIRE & CONDUIT IN OR BELOW FLOOR SLAB OR BELOW GRADE. WIRE & CONDUIT IN WALL OR ABOVE CEILING. EACH ARROWHEAD REPRESENTS ONE COMPLETE CIRCUIT; CAPITAL LETTER DENOTES PANEL; NUMBER DENOTES CIRCUIT. A-1&2 LIGHTING FIXTURE ON NIGHT LIGHT OR EMERGENCY CIRCUIT. H1 B1 V VALVE SUPERVISORY SWITCH. W WATER FLOW SWITCH. S DUCT MOUNTED SMOKE DETECTOR (S/SUPPLY, R/RETURN). S/R H CEILING MOUNTED HEAT DETECTOR. S CEILING MOUNTED SMOKE DETECTOR. F FIRE ALARM SENDING STATION (46" M.H.). FIRE ALARM SIGNALING LIGHT (80" A.F.F.), (# WHEN SHOWN INDICATES CANDELA RATING OF STROBE. WHEN A # IS NOT SHOWN, THE STROBE SHALL BE RATED 15 CANDELA IN CORRIDORS AND 30 CANDELA FOR ALL OTHER LOCATIONS. L 15 BE RATED 15 CANDELA IN CORRIDORS AND 30 CANDELA FOR ALL OTHER LOCATIONS. CANDELA RATING OF STROBE. WHEN A # IS NOT SHOWN, THE STROBE SHALL F FIRE ALARM HORN & SIGNAL LIGHT (80" A.F.F.), (# WHEN SHOWN INDICATES 15 BUSHED CONDUIT OUT ABOVE ACCESSIBLE CEILING. "W" INDICATES 48" M.H., "P" INDICATES 48" M.H.). STUB AN EMPTY 3/4" W TELEPHONE OUTLET (18" M.H. EXCEPT WHEN SUBSCRIPT LETTER IS SHOWN, 48" M.H.). SINGLE GANG OUTLET BOX WITH BLANK COVERPLATE. STUB AN EMPTY 3/4" BUSHED CONDUIT OUT ABOVE ACCESSIBLE CEILING. DATA OUTLET (18"M.H. EXCEPT WHEN SUBSCRIPT "W" IS SHOWN, MOUNT AT CIRCUIT BREAKER PANEL, SURFACE MOUNTED. CIRCUIT BREAKER PANEL, FLUSH MOUNTED. ELECTRIC MOTOR. COMBINATION MOTOR STARTER AND DISCONNECT SWITCH. SCHEDULE NOTES: 1 2 3 4 PROVIDE MOUNTING AND DIRECTIONAL ARROWS PER PLAN. COORDINATE EGRESS PATH WITH ARCHITECTURAL DRAWINGS PRIOR TO ORDERING ANY FIXTURES. MOUNTING HEIGHT 24'-0". MOUNTING HEIGHT 12'-0". SEE ALSO "GALLEGOS" LIGHTING SHEETS FOR LIGHT FIXTURE SCHEDULES. SCHEDULE NOTES: 1 BUSSMANN POWER MODULE SWITCH. SIZE PER MANUFACTURER'S RECOMMENDATIONS. 2 FUSED DISCONNECT TO BE INSTALLED PER NEC-695 REQUIREMENTS. 3 CONTROL PANEL BY STAGE LIFT SUPPLIER. E.C. TO COORDINATE WITH SUPPLIER FOR ALL ELECTRICAL REQUIREMENTS PRIOR TO ROUGH-IN. PROVIDE (2) DEDICATED 120V, 20A CKTS TO MCP-1 AND MCP-2. SEE SINGLE-LINE DIAGRAM IN SHEET # TP1.0 FOR DETAILS. 4 CONTROL PANEL FOR RIGGING SYSTEM BY SYSTEM SUPPLIER. E.C. TO COORDINATE FOR ALL ELECTRICAL REQUIREMENTS WITH RIGGING SYSTEM SUPPLIER PRIOR TO ROUGH-IN. PROVIDE (10) 120V, 20A CIRCUITS PER MANUFACTURER'S REQUIREMENTS. SEE SINGLE-LINE DIAGRAM IN SHEET # TR1.0 FOR DETAILS. 5 WEATHER PROOF DISCONNECT REQUIRED. 6 EC SHALL WIRE FAN THROUGH LINE VOLTAGE THERMOSTAT. HC SHALL FURNISH THERMOSTAT TO E.C. A CONVEYANCE / CONDUIT INSTALLATION - SHALL MEET ALL ANSI/NFPA 70 (NATIONAL ELECTRICAL CODE) REQUIREMENTS. B ALL CONDUCTORS WILL BE COPPER IN CONDUIT. INSULATION SHALL BE RATED FOR 600V. C ALL WORK WILL BE DONE IN ACCORDANCE WITH THE NEC. D ALL 20 AMP. 120 VOLT POWER CIRCUITS SHALL CONSIST OF #12 AWG CONDUCTORS UNLESS INDICATED OTHERWISE. E CONDUITS OF DIFFERENT MATERIALS SHALL NOT BE MIXED INDISCRIMINATELY IN THE SAME SYSTEM. F MAINTAIN 16" SPACING BETWEEN RECEPTACLES AND OTHER RECESSED OUTLETS EVEN WHEN LOCATED ON OPPOSITE SIDES OF PARTITION TO ELIMINATE SOUND TRANSMISSION FROM ONE SPACE TO THE OTHER. CENTER DEVICES WHERE APPLICABLE IN EACH WALL SECTION. G NO SECTION OF A TELECOMMUNICATION CONDUIT SYSTEM SHALL BE LONGER THAN 100' OR CONTAIN MORE THAN TWO 90° BENDS, OR 180° TOTAL OF BENDS AND ELEVATION CHANGES, BETWEEN PULL POINTS OR PULL BOXES. FOR CONDUIT RUNS THAT TOTAL MORE THAN 100' IN LENGTH, INSERT PULL BOXES SO THAT NO SEGMENT EXCEEDS THE 100' LIMIT. H BENDS IN TELECOMMUNICATIONS CONDUITS SHALL BE LONG SWEEPS WITH A RADIUS OF 10 TIMES THE INSIDE DIAMETER OF THE CONDUIT. I ALL METALLIC RACEWAYS (I.E., CONDUITS AND CABLE TRAY SYSTEMS) SHALL BE CONNECTED TO THE EXPANDED BUILDING GROUND LOOP, DIRECTLY TO THE COMMUNICATIONS RESOURCE ROOMS BUSBAR OR VIA INTERCONNECTION OF CONVEYANCE ALREADY CONNECTED TO BUSBAR. J FIRE STOPPING OF CONVEYANCE MUST MEET ALL APPLICABLE BUILDING CODE REQUIREMENTS. K CONFIRM DATA AND COMMUNICATION DEVICE LOCATIONS WITH ARCHITECT PRIOR TO ROUGH-IN. L REFER TO ARCHITECTURAL SHEETS FOR EXACT LOCATION OF TACKBOARDS, MARKER BOARDS, CASEWORK, DESKS, ETC.- CONFIRM LOCATION OF ALL ELECTRICAL DEVICES WITH ARCHITECT PRIOR TO ROUGH-IN. M ALL EXIT SIGNAGE SHALL BE WIRED AHEAD OF LOCAL SWITCHING. N REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF LIGHTS, DIFFUSERS, ETC. O ALL THEATRICAL LIGHITNG REQUIREMENTS SHALL BE COORDINATED WITH THE THEATRICAL LIGHTING CONSULTANT PRIOR TO ANY WORK BEING PERFORMED. P VERIFY EXACT LOCATION OF ALL LIGHTING FIXTURES WITH MECHANICAL DUCTS AND SPRINKLER PIPES AND HEADS BEFORE ROUGH-IN TO PREVENT CONFLICTS. Q EXACT LOCATION OF ALL DEVICES SERVING EQUIPMENT TO BE VERIFIED AT SITE WITH ARCHITECTURAL DRAWINGS PRIOR TO ROUGH-IN. R ALL EMPTY CONDUITS SHALL BE INSTALLED WITH PULL WIRE PER SPECIFICATIONS. S ALL AUDIO / VIDEO DEVICES AND EQUIPMENT LOCATIONS AND REQUIREMENTS SHALL BE COORDINATED WITH THE AUDIO / VIDEO CONTRACTOR PRIOR TO ANY WORKING BEING PERFORMED. T ALL DEVICES INSTALLED IN / ON WALLS, SHALL BE DONE SO THAT THEY ARE AT EQUAL ELEVATIONS. (I.E. DEVICES INSTALLED AT 18" M.H. SHALL ALL BE AT 18" M.H., ALL DEVICES INSTALLED AT 46" M.H. SHALL BE INSTALLED AT 46" M.H.) MOTOR 120V-1PH CHARACTERISTICS NAMEPLATE CIRCUIT NO. NUMBER FLA 407/450 HP KVA OR MOTOR LOCATION - 208V-3PH 208V-1PH - MAGNETIC MANUAL NEMA SIZE LOCATION TYPE AC DRIVES (VFD) MOTOR O/L BUILT-IN 2-SPEED 2-WINDING MOTOR CONT. NEAR MOTOR SEE NOTE TYPE STARTER FURNISHED BY ROOM NUMBER SEE NOTE PANEL EQUIP. CONT. CENTER STARTER MANUAL DISC. SWITCH NEAR MOTOR OR BREAKER FEEDER SW. RECEPTACLE PANELBOARD PANEL EQUIP. CONT. CENTER MOTOR CONT. DISCONNECT MEANS LOCATION FURNISHED BY INTEGRAL WITH MOTOR NO. BY E.C. INTERLOCK WITH FURNISHED BY SEE NOTE EQUIPMENT STARTER MANUAL AT CONTROL GRD. SIZE WIRE SIZE CONDUCTORS NUMBER OF SEE NOTE SEE NOTE CONDUIT SIZE FEEDER FIXTURE SYMBOL CAT. NO. G.E. LAMP WATTS/LAMP INCAN. FLUOR. FIXTURE VOLTAGE H.I.D. QUANTITY LAMPS CS-CEIL. SURFACE BRONZE C--CHAIN MTD. STANDARD SEE NOTE ALUMINUM BLACK WHITE UC-UNDER CAB. TRIM COLOR WM-WALL MTD. SM-STEM MTD. R--RECESSED S--SURFACE MOUNTING SEE NOTE DEPTH LENGTH WIDTH DIAMETER OR SIZE (IN.) MANUFACTURER & CATALOG NO. OTHER ACCEPTABLE MANUCATURES MEDIA DIFFUSING X1 LED INCLUDED 120 DUAL-LITE # LES SERIES MCPHILBEN, SURE-LITE CLEAR MIRROR FACE W/RED STENCIL LETTERS 4 PER PLAN 14.38 9.88 1.38 1 X2 LED 7 INCLUDED 120 DUAL-LITE # LT SERIES MCPHILBEN, SURE-LITE PER PLAN 14.38 9.88 1.38 1 RTU-1 MDP3-4 ROOF TOP UNIT #1 RTU-2 MDP3-5 RTU-3 MDP3-6 425/450 RTU-4 MDP3-7 165/225 ROOF H-1A RP2-2 BOILER #1 18FLA HWP-1 - HOT WATER PUMP 1 1.5HP HWP-2 - HOT WATER PUMP 2 1.5HP CP-1 - H.W. COIL PUMP 1 3/4HP CP-2 - CP-3 - CP-4 - AC-1 (15A MOCP) AIR CONDITIONER 1 8.0FLA HC SEE MAIN SWBD. "MDP3" 3 12 12 .75 - - - - - AC-2 (15A MOCP) AIR CONDITIONER 2 8.0FLA - CU-1 (40A MOCP) CONDENSING UNIT 1 20FLA 5 CU-2 (40A MOCP) CONDENSING UNIT 2 20FLA EF-1 - EXHAUST FAN 1 (1/4HP) - EF-2 - EXHAUST FAN 2 (1/4HP) - EF-3 - EXHAUST FAN 3 (1/4HP) EC - EF-4 - EXHAUST FAN 4 (1/6HP) EC - EF-5 - EXHAUST FAN 5 (1/4HP) - ELEV ELEVATOR 30HP EC FP FIRE PUMP 30HP EC 1 2 SL STAGE LIFT 10HP 3 H-1B BOILER #2 18FLA 3/4HP 1HP 3/4HP HWP-3 HOT WATER PUMP 3 HWP-4 HOT WATER PUMP 4 7.5HP 7.5HP AC-3 AC-4 (45A MOCP) (45A MOCP) AIR CONDITIONER 3 AIR CONDITIONER 4 33.5FLA 33.5FLA CU-3 CU-4 CONDENSING UNIT 3 CONDENSING UNIT 4 19.3FLA 19.3FLA (40A MOCP) (40A MOCP) EF-6 EF-7 EXHAUST FAN 6 EXHAUST FAN 7 (1/4HP) (1/6HP) ROOF TOP UNIT #2 ROOF TOP UNIT #3 ROOF TOP UNIT #4 204/250 381/400 RP2-3 JP JOCKEY PUMP 3/4HP AV 20A-125V DUPLEX RECEPTACLE, NEMA 5-20R, WITH ISOLATED GROUND (18" M.H.). H1 1 250 T4 LAMP 120 GOTHAM # CQ11-250-W-6AR-WLP-STEM-DBL COOPER, KIRLIN H2 1 500 T4 LAMP 120 COOPER, KIRLIN H3 1 400 T4 LAMP 120 COOPER, KIRLIN A 1 400 HPS 120 LSI # HFR5400HPS-120-F 2 B 1 125 MH 120 LSI # HFSH3175MH-120-F 3 GOTHAM # CQ11-250-W-6AR-WLP-STEM-DBL GOTHAM # CQ11-250-W-6AR-WLP-STEM-DBL DP2-1 DP2-2 DP2-4 DP2-8 DP2-9 DP2-19 DP2-21 DP2-22 DP2-23 EP-34 EP-35 EP-36 EP-37 EP-38 EP-39 EP-40 EP-41 EP-42 C 1 100 MH 120 GOTHAM # LAH-100M-12FW-FFL-120 COOPER, KIRLIN WHITE FACE W/RED STENCIL LETTERS 4 GENERAL LEGEND NOTES: A B SEE A/V DRAWINGS FOR LEGEND ON A/V DEVICES. SEE THEATRICAL LIGHTING DRAWINGS FOR LEGEND ON THEATRICAL LIGHTING FIXTURES. HC HC HC HC HC HC HC HC HC HC HC HC HC HC HC HC HC HC HC HC HC HC HC HC EC EC PC PC HC HC HC HC EC EC EC EC EC EC EC EC EC EC EC EC EC EC EC EC EC EC HC HC HC HC HC EC EC EC EC HC HC HC HC HC HC HC HC HC HC HC HC HC HC HC HC EC EC EC EC EC EC EC EC EC EC EC EC EC ROOF ROOF ROOF MECHANICAL ROOM MECHANICAL ROOM MECHANICAL ROOM MECHANICAL ROOM MECHANICAL ROOM MECHANICAL ROOM SERVE RTU-1 COIL SERVE RTU-2 COIL SERVE RTU-3 COIL SERVE RTU-4 COIL PROJECTION ROOM PROJECTION ROOM A/V RACK SERVER ROOM ROOF ROOF ROOF ROOF ROOF ROOF ROOF ROOF ROOF ELEV. EQUIP. ROOM FIRE PUMP ROOM MECHANICAL ROOM JAN. CLOSET 109 6KW 6KW DWH1 DWH2 DOM. WATER HEATER 1 DOM. WATER HEATER 2 3 12 12 .75 3 12 12 .75 3 12 12 .75 3 12 12 .75 3 12 12 .75 2 6 8 1 2 6 8 1 3 10 10 .75 3 10 10 .75 3 8 10 .75 3 8 10 .75 5 5 5 2 12 12 .75 2 12 12 .75 2 12 12 .75 2 12 12 .75 2 12 12 .75 2 12 12 .75 2 12 12 .75 3 1 6 1.5 3 1 6 1.5 3 12 12 .75 3 8 10 1.5 3 10 10 .75 3 10 10 .75 6 6 6 6 H.W. COIL PUMP 2 H.W. COIL PUMP 3 H.W. COIL PUMP 4 Date: Scale Drawn By Checked By Project Number ARCHITECTURE PLANNING INTERIOR DESIGN STRUCTURAL ENGINEERING 424 East Fourth Street Cincinnati, w w w . c h a r c h Ohio i t e c t s . 45202 c o m tel: 513/241/4474 fax: 513/241/0081 ISSUANCES COMPUTER FILE 1400 West Dorothy Lane Dayton, Ohio 45409-1310 Tel: (937) 224-0861 Fax: (937) 224-5777 3417 South Sherman Drive Beech Grove, IN 46107 Tel: (317) 780-1555 Fax: (317) 780-6525 750 North Orleans, Suite 400 Chicago, IL 60610 Tel: (312) 944-8230 Fax: (312) 944-8297 117 East Washington Street, Suite 200 Indianapolis, IN 46204 Tel: (317) 637-2222 Fax: (317) 637-2260 1137 West Taylor St. Suite 316 Chicago, IL 60607 Tel: (312) 224-8460 Fax: (312) 224-8961 1025 N.Watery Ln. Brigham City, UT 84302 TEL: (453) 723-5000 FAX: (453) 538-5506 6622 Kingspointe Parkway Orlando, FL 33819 Tel: (407) 816-9400 Fax: (407) 816-9300 1 SCHEMATIC DESIGN 10.18.07 2 DESIGN DEVELOPMENT 01.18.08 3 CD 50% 03.14.08 4 PERMIT SET 04.25.08 5 ADDENDUM #2 05.16.08 No. Description Date 6 ADDENDUM #3 05.22.08 7 ADDENDUM #5 06.04.08 8 PERMIT SET 06.10.08 6/10/2008 1:00:11 PM C:\Drawings\2007-06019-Central-Local.rvt E001 LIGHTING FIXTURE SCHEDULE, LEGEND & INDEX OF DRAWINGS New Worship Center Checker Author 05-22-08 2007-06019 ELECTRICAL DRAWING INDEX SHEET DESCRIPTION E001 LIGHTING FIXTURE SCHEDULE, LEGEND & INDEX OF DRAWINGS E002 SITE LIGHTING AND UTILITY PLAN E003 ELECTRICAL DETAILS E100 GATHERING CENTER - DEMO E200 PIT LEVEL - LIGHTING PLAN E201 FIRST FLOOR - LIGHTING PLAN E202 BALCONY ONE - LIGHTING PLAN E203 BALCONY TWO - LIGHTING PLAN E205 CATWALK - NEW WORK - LIGHTING E206 ROOF LIGHTING E300 PIT LEVEL - POWER PLAN E301 FIRST FLOOR - POWER PLAN E301-A FIRST FLOOR - POWER PLAN - ALTERNATE E302 BALCONY ONE - POWER PLAN E302-A BALCONY ONE - POWER PLAN - ALTERNATE E303 BALCONY TWO - POWER PLAN E305 CATWALK-POWER PLAN E400 SINGLE-LINE DISTRIBUTION DIAGRAM E401 PANELBOARD SCHEDULES E402 PANELBOARD SCHEDULES E403 PANELBOARD SCHEDULES