Loading...
HomeMy WebLinkAboutE201 - FIRST FLOOR - LIGHTING PLANOS J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J DN DN UP UP UP DN UP UP UP F.E.C. F.E.C. F.E.C. F.E.C. DN UP W-2 W-2 W-2 W-2 W-2 CW-1 CW-1 CW-8 CW-8 CW-8 CC-1 CC-1 CC-1 CC-1 CC-1 CC-1 CC-1 CC-1 CC-1 CC-1 CC-1 CC-1 CC-1 CC-1 CC-1 CC-1 CC-1 CC-1 CC-1 CC-1 CC-1 CC-1 CC-1 CC-1 CC-1 CC-1 ML-2 CW-4 CW-4 CW-4 CW-4 CW-4 ML-2 RF-1 RF-1 RF-1 DI-2 DI-2 DI-2 DI-2 DF-2 CC-3 CC-3 CC-3 CW-6 CW-6 CW-6 CW-6 CC-3 CC-3 CC-3 CC-3 CC-3 CW-7 CW-7 CW-7 CW-7 CW-5 CW-5 RF-1 RF-1 CW-1 CW-1 CW-8 CC-3 DF-2 DI-2 DI-2 RF-1 DF-2 DF-2 DF-2 DF-2 DI-2 DI-2 DI-2 DI-2 DI-2 CW-8 CW-8 CW-4 CW-4 W-2 W-2 W-2 W-2 CC-1 CC-1 CC-1 CC-1 W-2 W-2 W-2 W-2 W-2 DF-6 CW-4 CW-4 CW-4 CW-4 CW-4 CW-4 CW-4 DP2 - 23 DP2 - 21 W-3 W-3 LP1 - 16 LP1 - 17 LP1 - 18 LP1 - 19 DP2 - 22 DP2 - 18 EP - 6 DP2 - 20 LP1 - 21 DP2 - 19 ML-2 ML-2 LP1 - 34 LP1 - 34 EP - 3 LP2 - 17 W-2 W-2 W-2 W-2 W-2 W-2 EP - 15 4 (TYP.) 4 (TYP.) 4 (TYP.) 4 (TYP.) 4 (TYP.) 4 (TYP.) ML-3 (4 CKTS.) ML-3 (4 CKTS.) ML-3 (4 CKTS.) ML-3 (4 CKTS.) ML-3 (4 CKTS.) DP3 - 1 DP3 - 2 DP3 - 3 DP3 - 4 DP3 - 5 DP3 - 6 DP3 - 7 DP3 - 8 DP3 - 9 DP3 - 10 DP3 - 11 DP3 - 12 DP3 - 13 DP3 - 14 DP3 - 15 DP3 - 16 DP3 - 17 DP3 - 18 DP3 - 19 DP3 - 20 LP2 - 19 TL-3 TL-3 TL-3 TL-3 TL-3 TL-3 TL-3 TL-3 TL-3 TL-3 TL-3 TL-3 TL-3 TH-2 TH-2 1 1 TH-2 TH-2 1 1 TH-2 1 TH-2 1 TH-2 1 TH-2 1 8 3 3 3 2 2 2 3 DP2 - 14 DP2 - 13 DP2 - 12 DP2 - 11 DP2 - 10 DP2 - 15 DP2 - 16 DP2 - 17 LOWER BALCONY PIPE (TYP.) UPPER BALCONY PIPE (TYP.) X1 X1 X1 X1 X1 X1 X1 X1 EP - 4 X1 5 6 6 6 6 6 6 6 6 2 119 117 120 S-11 S-12 118 116 115 107 106 102 110 112 113 111 105 108 109 101 124 S-13 S-14 104 C-101 103 7 (TYP.) 8 8 8 4 4 4 4 4 4 EP - 19 EP - 20 X1 X1 X1 X1 X1 9 9 9 9 9 9 9 9 9 9 Date: Scale Drawn By Checked By Project Number ARCHITECTURE PLANNING INTERIOR DESIGN STRUCTURAL ENGINEERING 424 East Fourth Street Cincinnati, w w w . c h a r c h Ohio i t e c t s . 45202 c o m tel: 513/241/4474 fax: 513/241/0081 ISSUANCES COMPUTER FILE 1400 West Dorothy Lane Dayton, Ohio 45409-1310 Tel: (937) 224-0861 Fax: (937) 224-5777 3417 South Sherman Drive Beech Grove, IN 46107 Tel: (317) 780-1555 Fax: (317) 780-6525 750 North Orleans, Suite 400 Chicago, IL 60610 Tel: (312) 944-8230 Fax: (312) 944-8297 117 East Washington Street, Suite 200 Indianapolis, IN 46204 Tel: (317) 637-2222 Fax: (317) 637-2260 1137 West Taylor St. Suite 316 Chicago, IL 60607 Tel: (312) 224-8460 Fax: (312) 224-8961 1025 N.Watery Ln. Brigham City, UT 84302 TEL: (453) 723-5000 FAX: (453) 538-5506 6622 Kingspointe Parkway Orlando, FL 33819 Tel: (407) 816-9400 Fax: (407) 816-9300 1 SCHEMATIC DESIGN 10.18.07 2 DESIGN DEVELOPMENT 01.18.08 3 CD 50% 03.14.08 4 PERMIT SET 04.25.08 5 ADDENDUM #2 05.16.08 No. Description Date 6 ADDENDUM #3 05.22.08 7 ADDENDUM #5 06.04.08 8 PERMIT SET 06.10.08 1/8" = 1'-0" 6/10/2008 1:00:41 PM C:\Drawings\2007-06019-Central-Local.rvt E201 FIRST FLOOR - LIGHTING PLAN New Worship Center Checker Author 05-22-08 2007-06019 GENERAL NOTES A REFER TO LIGHTING CONSULTANT DRAWINGS FOR EXACT LOCATIONS AND TYPES. B WIRE ALL "EXIT" LIGHT FIXTURES ON THIS LEVEL TO EMERGENCY CIRCUIT EP-5. WIRE THIS CIRCUIT AHEAD OF ANY LOCAL SWITCHES TO BE "ON" 24HRS. 1/8" = 1'-0" 1 LIGHTING - LEVEL-1 - NEW WORK NOTES 1 PROVIDE ONE DIMMING CIRCUIT FOR EACH FIXTURE TYPE "TH2" FROM DIMMING RACK DP#2 (OPTIO-9) IN CATWALK. COORDINATE WITH LIGHTING CONSULTANT/SYSTEM INTEGRATOR FOR THE TYPE OF OUTLET AND MOUNTING ARRANGEMENTS. 2 FIXTURE "TH-2" MOUNTS TO LOWER BALCONY PIPE. 3 FIXTURE "TH-2" MOUNTS TO UPPER BALCONY PIPE. 4 LIGHTING FIXTURES SHALL BE WIRED AHEAD OF LOCAL SWITCHING FOR 24 HOUR OPERATION. 5 PROVIDE ONE DEEP SINGLE GANG BOX WITH PATHPORT UNO AND .75" CONDUIT TO THE CONTROL EQUIPMENT RACK IN THE BOOTH. CAT #5 CABLE BY OTHERS. OVERALL LENGTH SHOULD NOT EXCEED 285'-0". COORDINATE LOCATION OF THIS BOX WITH LIGHTING CONSULTANT / SYSTEM INTEGRATOR PRIOR TO ROUGH-IN. 6 PROVIDE SINGLE CIRCUIT PLUG BOX FOR TYPE "TH-2" FIXTURES IN FIRST AND SECOND BALCONY RAILS. 7 NOTE OMITTED. 8 THESE DIMMER CIRCUITS TO BE SWITCHED AND FED FROM PANEL "EP" IN CASE OF FAILURE OF NORMAL POWER THRU UC700 (UL1008) TRANSFER CABINET. COORDINATE WITH SYSTEM INTEGRATOR FOR REQUIREMENTS PRIOR TO ROUGH-IN. SEE ALSO SHEET E001 FOR NORMAL EMERGENCY CIRCUIT SCHEDULE. 9 PROVIDE WIREMOLD FLOOR BOX - 880 OMNIBOX (880M1) - WITH FLANGE (817B) AND COVER PLATE (829CK) FOR AISLE LIGHTING. COORDINATE COLOR / FINISH WITH ARCHITECT PRIOR TO ORDER. PROVIDE ALL NECESSARY ACCESSORIES AND FITTINGS TO MAKE A COMPLETE SYSTEM. 101 ENTRANCE LOBBY 102 VESTIBULE 103 WORSHIP CENTER 104 SOUND BOOTH 105 CHAIR STORAGE/CATERING 106 VESTIBULE 107 VESTIBULE 108 MEN'S RESTROOM 109 JANITOR ROOM 110 WOMEN'S RESTROOM 111 WOMEN'S RESTROOM 112 VESTIBULE 113 VESTIBULE 115 STORAGE 116 WORKSHOP 117 SIDE PLATFORM 118 DELIVERY 119 PLATFORM 120 SIDE PLATFORM 124 JANITOR C-101 CORRIDOR S-11 STAIR-1 S-12 STAIR-2 S-13 STAIR-3 S-14 STAIR-4 ROOM INDEX