HomeMy WebLinkAboutE205 - CATWALK - NEW WORK - LIGHTINGJ
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J J J J J
J J J J J J J J J J
J J J J
J J J J J J J J J J J J J J J
J J J
J J
DN
DN
DN
UP
DN
DN
DN DN
F.E.C.
DN
CP-1
CP-1
CP-1
CP-1
CP-1
CP-1
CP-1
CP-1
CP-1
CP-1
CW-8
CW-6
W-1
W-1
W-1
W-1
W-1
W-1
W-1
W-1
W-1 W-1
W-1
W-1
W-1
W-1
W-1
W-1
W-1
W-1
W-1
W-1
W-1
W-1 W-1
W-1
W-1
W-1
W-1
W-1
W-1
W-1 W-1
W-1
W-1
W-1 W-1
W-1
W-1
W-1
TL-1
W-1
TL-1
W-1
TL-1
TL-1 TL-1
TL-1
TL-1
TL-1
TL-1
TL-1
TL-1
TL-1
TL-1
TL-1 TL-1
TL-1
TL-1
TL-1
TL-1
TL-1
TL-1
TL-1
TL-1
TL-1
TL-1
TL-1
TL-1
TL-1
TL-1
TL-1
TL-1
TL-1
TL-1
TL-1
TL-1 TL-1
TL-1
TL-1
TL-1
TL-1
TL-1
TL-1
TL-1
W-1
TL-1
W-1
TL-1
TL-1
TL-1
TL-1
CP-1
CP-1
CP-1
CP-1
CP-1
CP-1
CP-1
CP-1
CP-1
CP-1
H-1
H-1
H-1
H-1
H-1
H-1
H-1
H-1
H-1
H-1
LP1 - 32
LP1 - 25
H-2
H-2
H-2
H-2
H-2
H-2
H-2
H-2
H-2
H-2
H-2 H-2
H-3 H-3 H-3
H-3
EP - 7
EP - 8
EP - 9
EP - 10
EP - 11
EP - 12
EP - 13
EP - 14
LP1 - 31
TH-1
TH-1
TH-1
TH-1
TH-1
TH-1
TH-1
TH-1
TH-1
TH-1
TH-1
TH-1
TH-1
TH-1
TH-1
TL-2 TH-1 TL-2 TH-1 TL-2
TL-2 TL-2 TL-2
TH-1 TL-2 TH-1
TL-2
TL-2 TH-1
TL-2
TL-2 TH-1 TL-2 TH-1 TL-2
TL-2
TL-2
TH-1 TL-2 TH-1 TL-2 TL-2 TH-1 TL-2 TH-1 TL-2 TH-1
TL-2 TL-2 TL-2 TL-2 TL-2
LP2 - 1
LP2 - 2
LP2 - 3
LP2 - 4
LP2 - 5
LP2 - 6
LP2 - 7
LP2 - 8
LP2 - 11 LP2 - 10 LP2 - 9
LP2 - 12
LP2 - 16 LP2 - 15 LP2 - 14 LP2 - 13
3
4
3 (TYP.)
CATWALK-5
CATWALK-4
CATWALK-3
CATWALK-2
2 (TYP.)
3 (TYP.)
2 (TYP.)
4 4
4 4
2 (TYP.) 2 (TYP.) 2 (TYP.)
1 2 (TYP.)
2 (TYP.) 1 2 (TYP.) 1 2 (TYP.) 1 2 (TYP.)
1
CATWALK-1
1 2 (TYP.)
2 (TYP.)
3 (TYP.)
3
4
LP1 - 26
LP1 - 27
LP1 - 29
LP1 - 28
6
6
6
LP1 - 30
LP1 - 31
6 6
6
3 (TYP.)
5
5
8
7
10
9
X1
Date: Scale
Drawn By
Checked By
Project
Number
ARCHITECTURE
PLANNING
INTERIOR DESIGN
STRUCTURAL ENGINEERING
424 East Fourth
Street
Cincinnati, w w w . c h a r c h Ohio i t e c t s . 45202 c o m
tel: 513/241/4474 fax: 513/241/0081
ISSUANCES
COMPUTER FILE
1400 West Dorothy Lane
Dayton, Ohio 45409-1310
Tel: (937) 224-0861
Fax: (937) 224-5777
3417 South Sherman Drive
Beech Grove, IN 46107
Tel: (317) 780-1555
Fax: (317) 780-6525
750 North Orleans, Suite 400
Chicago, IL 60610
Tel: (312) 944-8230
Fax: (312) 944-8297
117 East Washington
Street, Suite 200
Indianapolis, IN 46204
Tel: (317) 637-2222
Fax: (317) 637-2260
1137 West Taylor St.
Suite 316
Chicago, IL 60607
Tel: (312) 224-8460
Fax: (312) 224-8961
1025 N.Watery Ln.
Brigham City, UT 84302
TEL: (453) 723-5000
FAX: (453) 538-5506
6622 Kingspointe
Parkway
Orlando, FL 33819
Tel: (407) 816-9400
Fax: (407) 816-9300
1 SCHEMATIC DESIGN 10.18.07
2 DESIGN DEVELOPMENT 01.18.08
3 CD 50% 03.14.08
4 PERMIT SET 04.25.08
5 ADDENDUM #2 05.16.08
No. Description Date
6 ADDENDUM #3 05.22.08
7 ADDENDUM #5 06.04.08
8 PERMIT SET 06.10.08
1/8" = 1'-0"
6/10/2008 1:01:17 PM
C:\Drawings\2007-06019-Central-Local.rvt
E205
CATWALK - NEW
WORK - LIGHTING
New Worship
Center
Checker
Author
05-22-08
2007-06019
GENERAL NOTES
A REFER TO LIGHTING CONSULTANT DRAWINGS FOR EXACT LOCATIONS AND
TYPES.
B WIRE ALL "EXIT" LIGHT FIXTURES ON THIS LEVEL TO EMERGENCY CIRCUIT EP-24.
WIRE THIS CIRCUIT AHEAD OF ANY LOCAL SWITCHES TO BE "ON" 24HRS.
1/8" = 1'-0"
1
LIGHTING - CATWALK - NEW WORK
PLAN NOTES
1 PROVIDE J-BOX AT THE CENTER OF THE PIPE AND DISTRIBUTE BRANCH FEEDERS
FOR FIXTURES FROM THIS JUNCTION BOX. COORDINATE WITH LIGHTING
CONSULTANT/SYSTEM INTEGRATOR PRIOR TO ROUGH-IN.
2 CATWALK NON-DIMMING FIXTURE ARE FED FROM INTELLIGENT RACEWAY.
3 PROVIDE DEEP SINGLE-GANG BOX WITH DMX XLR5-IN AND XLR5-OUT 5-PIN
CONNECTORS AND CABLES FOR EACH FIXTURE CP-1. COORDINATE LOCATION WITH
SYSTEM INTEGRATOR. ALSO, PROVIDE ONE DEEP SINGLE-GANG BOX WITH
"PATHPORT UNO" - DMX12/RJ45. PROVIDE .75" CONDUIT FROM BOX TO THE CONTROL
EQUIPMENT RACK IN THE CATWALK. DATA CABLE BY OTHERS. COORDINATE WITH
LIGHTING CONSULTANT/SYSTEM INTEGRATOR PRIOR TO ROUGH-IN.
LIGHTING CONSULTANT: MICHAEL J. SCHRUPP
XNTH GALLAGOS LIGHTING
PHONE: 510-787-0338
E-MAIL: mschruppAx-nth.com
SYSTEM INTEGRATOR: VINCENT LIGHTING
WALT WEBER/MATT KLASMEIER
PHONE: 859-535-2000
E-MAIL: wweber@vls.com/mklasmeier@vls.com
OVERALL DATA CABLE LENGTH SHOULD NOT EXCEED 285'-0".
4 PROVIDE "ON AND OFF" TOGGLE SWITCH AT THE ENTRY POINTS TO THE CATWALK
FOR CONTROL OF "W-1" FIXTURES.
5 THERE ARE 32 TYPE "TH-2" FIXTURES IN CATWALK #4 AND CATWALK #5. PROVIDE
ONE (1) DIMMING CIRCUIT FOR EACH "TH-2" FIXTURE FROM DIMMING RACK DP #1
(OPTIO-9) IN CATWALK. COORDINATE WITH LIGHTING CONSULTANT/SYSTEM
INTEGRATOR FOR THE TYPE OF OUTLET, MOUNTING ARRANGEMENTS AND OTHER
ELECTRICAL REQUIREMENTS.
6 PROVIDE DEEP SINGLE GANG BOX WITH PATHPORT UNO AND .75" CONDUIT TO
CONTROL EQUIPMENT RACK. CAT #5 CABLE BY OTHERS. OVERALL LENGTH SHOULD
NOT EXCEED 285'-0".
7 PROVIDE SEVEN (7) PLUG BOXES WITH EACH PLUG BOX HAVING 3 CIRCUITS FOR
TYPE "TH-2" FIXTURES IN CATWALK #5.
8 PROVIDE FIVE (5) PLUG BOXES WITH EACH PLUG BOX HAVING 3 CIRCUITS FOR TYPE
"TH-2" FIXTURES IN CATWALK #4.
9 PROVIDE ONE (1) DEEP SINGLE GANG BOX WITH PATHPORT UNO _DMXS12/RJ45 FOR
FIXTURE TYPE "TH-1" IN CATWALK #5. PROVIDE .75" CONDUIT FROM BOX TO CONTROL
EQUIPMENT RACK IN CATWALK. COORDINATE WITH SYSTEM INTEGRATOR PRIOR TO
ROUGH-IN. CATWALK #5 CABLE BY OTHERS. OVERALL LENGTH OF CABLE SHOULD
NOT EXCEED 285'-0".
10 PROVIDE ONE (1) DEEP SINGLE GANG BOX WITH PATHPORT UNO _DMXS12/RJ45 FOR
FIXTURE TYPE "TH-1" IN CATWALK #4. PROVIDE .75" CONDUIT FROM BOX TO CONTROL
EQUIPMENT RACK IN CATWALK. COORDINATE WITH SYSTEM INTEGRATOR PRIOR TO
ROUGH-IN. CATWALK #4 CABLE BY OTHERS. OVERALL LENGTH OF CABLE SHOULD
NOT EXCEED 285'-0".