Loading...
HomeMy WebLinkAboutE205 - CATWALK - NEW WORK - LIGHTINGJ J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J DN DN DN UP DN DN DN DN F.E.C. DN CP-1 CP-1 CP-1 CP-1 CP-1 CP-1 CP-1 CP-1 CP-1 CP-1 CW-8 CW-6 W-1 W-1 W-1 W-1 W-1 W-1 W-1 W-1 W-1 W-1 W-1 W-1 W-1 W-1 W-1 W-1 W-1 W-1 W-1 W-1 W-1 W-1 W-1 W-1 W-1 W-1 W-1 W-1 W-1 W-1 W-1 W-1 W-1 W-1 W-1 W-1 W-1 W-1 TL-1 W-1 TL-1 W-1 TL-1 TL-1 TL-1 TL-1 TL-1 TL-1 TL-1 TL-1 TL-1 TL-1 TL-1 TL-1 TL-1 TL-1 TL-1 TL-1 TL-1 TL-1 TL-1 TL-1 TL-1 TL-1 TL-1 TL-1 TL-1 TL-1 TL-1 TL-1 TL-1 TL-1 TL-1 TL-1 TL-1 TL-1 TL-1 TL-1 TL-1 TL-1 TL-1 TL-1 TL-1 W-1 TL-1 W-1 TL-1 TL-1 TL-1 TL-1 CP-1 CP-1 CP-1 CP-1 CP-1 CP-1 CP-1 CP-1 CP-1 CP-1 H-1 H-1 H-1 H-1 H-1 H-1 H-1 H-1 H-1 H-1 LP1 - 32 LP1 - 25 H-2 H-2 H-2 H-2 H-2 H-2 H-2 H-2 H-2 H-2 H-2 H-2 H-3 H-3 H-3 H-3 EP - 7 EP - 8 EP - 9 EP - 10 EP - 11 EP - 12 EP - 13 EP - 14 LP1 - 31 TH-1 TH-1 TH-1 TH-1 TH-1 TH-1 TH-1 TH-1 TH-1 TH-1 TH-1 TH-1 TH-1 TH-1 TH-1 TL-2 TH-1 TL-2 TH-1 TL-2 TL-2 TL-2 TL-2 TH-1 TL-2 TH-1 TL-2 TL-2 TH-1 TL-2 TL-2 TH-1 TL-2 TH-1 TL-2 TL-2 TL-2 TH-1 TL-2 TH-1 TL-2 TL-2 TH-1 TL-2 TH-1 TL-2 TH-1 TL-2 TL-2 TL-2 TL-2 TL-2 LP2 - 1 LP2 - 2 LP2 - 3 LP2 - 4 LP2 - 5 LP2 - 6 LP2 - 7 LP2 - 8 LP2 - 11 LP2 - 10 LP2 - 9 LP2 - 12 LP2 - 16 LP2 - 15 LP2 - 14 LP2 - 13 3 4 3 (TYP.) CATWALK-5 CATWALK-4 CATWALK-3 CATWALK-2 2 (TYP.) 3 (TYP.) 2 (TYP.) 4 4 4 4 2 (TYP.) 2 (TYP.) 2 (TYP.) 1 2 (TYP.) 2 (TYP.) 1 2 (TYP.) 1 2 (TYP.) 1 2 (TYP.) 1 CATWALK-1 1 2 (TYP.) 2 (TYP.) 3 (TYP.) 3 4 LP1 - 26 LP1 - 27 LP1 - 29 LP1 - 28 6 6 6 LP1 - 30 LP1 - 31 6 6 6 3 (TYP.) 5 5 8 7 10 9 X1 Date: Scale Drawn By Checked By Project Number ARCHITECTURE PLANNING INTERIOR DESIGN STRUCTURAL ENGINEERING 424 East Fourth Street Cincinnati, w w w . c h a r c h Ohio i t e c t s . 45202 c o m tel: 513/241/4474 fax: 513/241/0081 ISSUANCES COMPUTER FILE 1400 West Dorothy Lane Dayton, Ohio 45409-1310 Tel: (937) 224-0861 Fax: (937) 224-5777 3417 South Sherman Drive Beech Grove, IN 46107 Tel: (317) 780-1555 Fax: (317) 780-6525 750 North Orleans, Suite 400 Chicago, IL 60610 Tel: (312) 944-8230 Fax: (312) 944-8297 117 East Washington Street, Suite 200 Indianapolis, IN 46204 Tel: (317) 637-2222 Fax: (317) 637-2260 1137 West Taylor St. Suite 316 Chicago, IL 60607 Tel: (312) 224-8460 Fax: (312) 224-8961 1025 N.Watery Ln. Brigham City, UT 84302 TEL: (453) 723-5000 FAX: (453) 538-5506 6622 Kingspointe Parkway Orlando, FL 33819 Tel: (407) 816-9400 Fax: (407) 816-9300 1 SCHEMATIC DESIGN 10.18.07 2 DESIGN DEVELOPMENT 01.18.08 3 CD 50% 03.14.08 4 PERMIT SET 04.25.08 5 ADDENDUM #2 05.16.08 No. Description Date 6 ADDENDUM #3 05.22.08 7 ADDENDUM #5 06.04.08 8 PERMIT SET 06.10.08 1/8" = 1'-0" 6/10/2008 1:01:17 PM C:\Drawings\2007-06019-Central-Local.rvt E205 CATWALK - NEW WORK - LIGHTING New Worship Center Checker Author 05-22-08 2007-06019 GENERAL NOTES A REFER TO LIGHTING CONSULTANT DRAWINGS FOR EXACT LOCATIONS AND TYPES. B WIRE ALL "EXIT" LIGHT FIXTURES ON THIS LEVEL TO EMERGENCY CIRCUIT EP-24. WIRE THIS CIRCUIT AHEAD OF ANY LOCAL SWITCHES TO BE "ON" 24HRS. 1/8" = 1'-0" 1 LIGHTING - CATWALK - NEW WORK PLAN NOTES 1 PROVIDE J-BOX AT THE CENTER OF THE PIPE AND DISTRIBUTE BRANCH FEEDERS FOR FIXTURES FROM THIS JUNCTION BOX. COORDINATE WITH LIGHTING CONSULTANT/SYSTEM INTEGRATOR PRIOR TO ROUGH-IN. 2 CATWALK NON-DIMMING FIXTURE ARE FED FROM INTELLIGENT RACEWAY. 3 PROVIDE DEEP SINGLE-GANG BOX WITH DMX XLR5-IN AND XLR5-OUT 5-PIN CONNECTORS AND CABLES FOR EACH FIXTURE CP-1. COORDINATE LOCATION WITH SYSTEM INTEGRATOR. ALSO, PROVIDE ONE DEEP SINGLE-GANG BOX WITH "PATHPORT UNO" - DMX12/RJ45. PROVIDE .75" CONDUIT FROM BOX TO THE CONTROL EQUIPMENT RACK IN THE CATWALK. DATA CABLE BY OTHERS. COORDINATE WITH LIGHTING CONSULTANT/SYSTEM INTEGRATOR PRIOR TO ROUGH-IN. LIGHTING CONSULTANT: MICHAEL J. SCHRUPP XNTH GALLAGOS LIGHTING PHONE: 510-787-0338 E-MAIL: mschruppAx-nth.com SYSTEM INTEGRATOR: VINCENT LIGHTING WALT WEBER/MATT KLASMEIER PHONE: 859-535-2000 E-MAIL: wweber@vls.com/mklasmeier@vls.com OVERALL DATA CABLE LENGTH SHOULD NOT EXCEED 285'-0". 4 PROVIDE "ON AND OFF" TOGGLE SWITCH AT THE ENTRY POINTS TO THE CATWALK FOR CONTROL OF "W-1" FIXTURES. 5 THERE ARE 32 TYPE "TH-2" FIXTURES IN CATWALK #4 AND CATWALK #5. PROVIDE ONE (1) DIMMING CIRCUIT FOR EACH "TH-2" FIXTURE FROM DIMMING RACK DP #1 (OPTIO-9) IN CATWALK. COORDINATE WITH LIGHTING CONSULTANT/SYSTEM INTEGRATOR FOR THE TYPE OF OUTLET, MOUNTING ARRANGEMENTS AND OTHER ELECTRICAL REQUIREMENTS. 6 PROVIDE DEEP SINGLE GANG BOX WITH PATHPORT UNO AND .75" CONDUIT TO CONTROL EQUIPMENT RACK. CAT #5 CABLE BY OTHERS. OVERALL LENGTH SHOULD NOT EXCEED 285'-0". 7 PROVIDE SEVEN (7) PLUG BOXES WITH EACH PLUG BOX HAVING 3 CIRCUITS FOR TYPE "TH-2" FIXTURES IN CATWALK #5. 8 PROVIDE FIVE (5) PLUG BOXES WITH EACH PLUG BOX HAVING 3 CIRCUITS FOR TYPE "TH-2" FIXTURES IN CATWALK #4. 9 PROVIDE ONE (1) DEEP SINGLE GANG BOX WITH PATHPORT UNO _DMXS12/RJ45 FOR FIXTURE TYPE "TH-1" IN CATWALK #5. PROVIDE .75" CONDUIT FROM BOX TO CONTROL EQUIPMENT RACK IN CATWALK. COORDINATE WITH SYSTEM INTEGRATOR PRIOR TO ROUGH-IN. CATWALK #5 CABLE BY OTHERS. OVERALL LENGTH OF CABLE SHOULD NOT EXCEED 285'-0". 10 PROVIDE ONE (1) DEEP SINGLE GANG BOX WITH PATHPORT UNO _DMXS12/RJ45 FOR FIXTURE TYPE "TH-1" IN CATWALK #4. PROVIDE .75" CONDUIT FROM BOX TO CONTROL EQUIPMENT RACK IN CATWALK. COORDINATE WITH SYSTEM INTEGRATOR PRIOR TO ROUGH-IN. CATWALK #4 CABLE BY OTHERS. OVERALL LENGTH OF CABLE SHOULD NOT EXCEED 285'-0".