HomeMy WebLinkAboutE301-A - FIRST FLOOR - POWER PLAN - ALTERNATES J J J J F F J J S F F L L L L L F F F F J J J J F L L L F F L L F F F F F F F F F H H H V V V W SC SC SC SC SC SC SC SC SC SC SC J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J J F F F L F L L F L DN UP UP DN UP UP UP F.E.C. F.E.C. F.E.C. F.E.C. DN UP GF GF AV AV AV AV AV AV TL1 AV TL1 CAM 6 6 6 TL1 AV CAM CAM CAM CAM 6 6 6 AV AV TL1 TL1 AV AV TL1 110 110 110 110 110 110 R WP/GF GF GF GF GF GF AV AV AV AV CAM AV CAM AV AV CAM AV RPAV1 - 34 RPAV1 - 37 F E1 B K L C1 L E1 G E1 G E1 RPAV1 - 12 RPAV1 - 13 G E1 G E1 RPAV1 - 14 RPAV1 - 15 B F E1 G H J E1 RPAV1 - 16 RPAV1 - 17 RPAV1 - 18 RPAV1 - 19 G E1 G E1 G E1 G E1 RPAV1 - 20,22 VDB RPAV1 - 21,23 RPAV1 - 24,26 E E E L E1 A C C1 A C1 C PRJ PRJ RPAV5-1-5 RPAV5-6-10 RPAV5-11-15 RPAV5-16-20 RPAV5-21-25 RPAV5 - 28 RPAV5 - 27 RPAV5 - 26 RPAV5 - 29 RPAV5 - 30 S5 AV S5 AV RPAV6 - 2 S5 AV S5 AV S5 AV RPAV6 - 1 A A A A A C1 FB1 AV RPAV6 - 6 FB1 AV RPAV6 - 7 FB1 AV RPAV6 - 8 FB1 AV RPAV6 - 9 N C1 N C1 N C1 N C1 RPAV6 - 10,12 AV C C1 RPAV6 - 11,13 AV C C1 RPAV6 - 15,17 AV C C1 RPAV6 - 14,16 C C1 AV S4 S4 S4 S4 RPAV1 - 10 AV 6 RPAV1 - 25 RPAV1 - 11 AV A A RPAV1 - 29 RP2 - 15 RP2 - 16 RP2 - 17 RP2 - 18 RP2 - 19 RP2 - 20 RP2 - 21 RP2 - 22 RP2 - 23 RP2 - 24 RP2 - 25 RP2 - 26 RP2 - 27 RAP REMOTE ANNUNCIATOR PANEL RPAV1 - 39,41 AV 4 4 4 RPAV1 - 40,42 AV 4 RPAV1 - 40,42 6 EF-1 RP5 - 10 6 EF-1 RP5 - 9 CP-1 10 - <unnamed> CP-2 10 RP1 - 39 UH-1 11 RP1 - 40 EF-5 6 MDP3 - 14 MDP3 - 15 RP2 - 2 RP2 - 28 RP2 - 3 6 9 9 RTU-4 RTU-3 A A A A A A C1 C1 A A A A 1 1 1 PRJ 3 6 3 3 2 5 5 EF-6 12 12 13 13 13 S-11 118 S-12 117 120 116 115 106 107 102 110 112 113 111 105 108 101 124 S-13 S-14 104 C-101 103 14 14 14 14 CPB H C1 A H1 A H1 A H1 A H1 A H1 A H1 A H1 A H1 A H1 A H1 A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A A 15 15 GF GF GF RP4 - 18,20,22 RP2 - 1 7 8 109 16 16 16 16 16 17 18 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 S8 RP5 - 17 RP5 - 16 RP4 - 21,23,25 11 UH-3 UH-3 11 DWH-2 Date: Scale Drawn By Checked By Project Number ARCHITECTURE PLANNING INTERIOR DESIGN STRUCTURAL ENGINEERING 424 East Fourth Street Cincinnati, w w w . c h a r c h Ohio i t e c t s . 45202 c o m tel: 513/241/4474 fax: 513/241/0081 ISSUANCES COMPUTER FILE 1400 West Dorothy Lane Dayton, Ohio 45409-1310 Tel: (937) 224-0861 Fax: (937) 224-5777 3417 South Sherman Drive Beech Grove, IN 46107 Tel: (317) 780-1555 Fax: (317) 780-6525 750 North Orleans, Suite 400 Chicago, IL 60610 Tel: (312) 944-8230 Fax: (312) 944-8297 117 East Washington Street, Suite 200 Indianapolis, IN 46204 Tel: (317) 637-2222 Fax: (317) 637-2260 1137 West Taylor St. Suite 316 Chicago, IL 60607 Tel: (312) 224-8460 Fax: (312) 224-8961 1025 N.Watery Ln. Brigham City, UT 84302 TEL: (453) 723-5000 FAX: (453) 538-5506 6622 Kingspointe Parkway Orlando, FL 33819 Tel: (407) 816-9400 Fax: (407) 816-9300 1 SCHEMATIC DESIGN 10.18.07 2 DESIGN DEVELOPMENT 01.18.08 3 CD 50% 03.14.08 4 PERMIT SET 04.25.08 5 ADDENDUM #2 05.16.08 No. Description Date 6 ADDENDUM #3 05.22.08 7 ADDENDUM #5 06.04.08 8 PERMIT SET 06.10.08 1/8" = 1'-0" 6/10/2008 1:02:43 PM C:\Drawings\2007-06019-Central-Local.rvt E301-A FIRST FLOOR - POWER PLAN - ALTERNATE New Worship Center Checker Author 05-22-08 2007-06019 1/8" = 1'-0" 1 POWER & SYSTEMS - LEVEL-1 - NEW WORK - ALTERNATE GENERAL NOTES A E.C. TO COORDINATE WITH A/V DRAWINGS: AV201, AV211, AV202, AV212, AV203, AV213, AV204, AV205, AV215, AV251, AV252, AV253, AV301, AV302 FOR BOX TYPE, MOUNTING HEIGHT, EXACT LOCATION FOR A/V DEVICES AND A/V EQUIPMENT AND ANY ADDITIONAL ELECTRICAL REQUIREMENTS PRIOR TO ROUGH-IN. A/V CONSULTANT: CRAIG COMPTON PRO-SOUND PH: 407-816-9400 E-MAIL: CCOMPTON@PROSOUND.NET PLAN NOTES A/V CONDUIT NOTES A (1) 3/4"C. B (3) 1"C. C (1) 1"C. D (1) 2"C. E (1) 1-1/2"C. F (3) 1-1/2"C. G (2) 1"C. H (2) 2"C. J (2) 4"C. K (3) 4"C. L (3) 2"C. M (1) 1/2"C. N (2) 1-1/4"C. O (2) 1-1/2"C. A1 TO VBB. B1 TO A/V RACKS 023. C1 TO A/V RACKS AT STAGE LOCATION. D1 TO SBB. E1 TO A/V RACKS 023 COMPUTER FLOOR. F1 TO VDB-501. G1 TO ADB-501. H1 TO CPB. 101 ENTRANCE LOBBY 102 VESTIBULE 103 WORSHIP CENTER 104 SOUND BOOTH 105 CHAIR STORAGE/CATERING 106 VESTIBULE 107 VESTIBULE 108 MEN'S RESTROOM 109 JANITOR ROOM 110 WOMEN'S RESTROOM 111 WOMEN'S RESTROOM 112 VESTIBULE 113 VESTIBULE 115 STORAGE 116 WORKSHOP 117 SIDE PLATFORM 118 DELIVERY 119 PLATFORM 120 SIDE PLATFORM 124 JANITOR C-101 CORRIDOR S-11 STAIR-1 S-12 STAIR-2 S-13 STAIR-3 S-14 STAIR-4 ROOM INDEX 1 PROVIDE RECEPTACLE WITH NEMA CONFIGURATION - 6-20R. COORDINATE EXACT REQUIREMENTS WITH A/V CONSULTANT PRIOR TO ROUGH-IN. 2 CABLE TRAY - 24" WIDTH x 4" DEPTH - CABLOFIL OR EQUAL. COORDINATE MOUNTING HEIGHT AND OTHER REQUIREMENTS WITH A/V CONSULTANT PRIOR TO ROUGH-IN. 3 WIREMOLD TRENCH DUCT - 12" WIDTH x 4" DEPTH. LID TO BE CUSTOM MADE. COORDINATE WITH ARCHITECT / A/V CONSULTANT FOR REQUIREMENTS. 4 PROVIDE SINGLE GANG BOX WITH 3/4" CONDUIT TO "CONTROL EQUIPMENT RACK" IN BOOTH. PROVIDE BLANK COVERPLATE. DATA OUTLET AND CABLING BY OTHERS. COORDINATE EXACT LOCATION AND MOUNTING HEIGHT WITH LIGHTING CONSULTANT / SYSTEM INTEGRATOR PRIOR TO ROUGH-IN. 5 PROVIDE DUCT MOUNTED SMOKE DETECTORS ON THE RETURN DUCT FOR ROOFTOP UNITS AND INTERFACE WITH FACP TO SHUT-DOWN UNITS UPON ALARM. COORDINATE LOCATION WITH HVAC DRAWINGS. 6 EXHAUST FAN. PROVIDE ELECTRICAL ROUGH-IN AND FINAL CONNECTIONS. COORDINATE LOCATION, CONTROL, AND OTHER ELECTRICAL REQUIREMENTS WITH HVAC DRAWINGS WITH HVAC DRAWINGS. 7 ELECTRICAL WATER HEATER. PROVIDE FUSED DISCONNECT. PROVIDE ELECTRICAL ROUGH-IN AND FINAL CONNECTIONS PER REQUIREMENTS. COORDINATE LOCATION WITH PLUMBING DRAWINGS. 8 DEDICATED OUTLET WITH 120V, 20A CIRCUIT FOR RECIRCULATING PUMP FOR WATER HEATER. COORDINATE LOCATION WITH PLUMBING DRAWINGS. 9 PROVIDE GFI/WP RECEPTACLE AND VAPORPROOF APPLETON LIGHT FIXTURE FOR ROOFTOP UNITS. COORDINATE LOCATION WITH UNIT. PROVIDE WEATHERPROOF LIGHT SWITCH FOR LIGHT FIXTURE. 10 COIL PUMP. PROVIDE COMBINATION STARTER AND SIZE PER REQUIREMENTS. COORDINATE OTHER ELECTRICAL REQUIREMENTS WITH HVAC DRAWINGS. 11 UNIT HEATER. PROVIDE ELECTRICAL ROUGH-IN AND FINAL CONNECTIONS. COORDINATE LOCATION, MOUNTING HEIGHT, AND OTHER ELECTRICAL REQUIREMENTS WITH HVAC DRAWINGS. 12 CIRCUIT # RPAV6-2 FEEDS POWER OUTLETS IN THESE BOXES. 13 CIRCUIT # RPAV6-1 FEEDS POWER OUTLETS IN THESE BOXES. 14 PROVIDE SINGLE GANG BOX WITH 3/4" CONDUIT TO THE SERVER ROOM. PROVIDE A BLANK COVER PLATE. RJ45 OUTLET AND CAT5 CABLING BY OTHERS. OVERALL LENGTH SHOULD NOT EXCEED 285'. 15 PROVIDE FUSED DISCONNECT TYPE NEMA 3R FOR ROOF TOP UNIT AND WIRE PER REQUIREMENTS. 16 CONDUITS FROM MAIN LEVEL, BOOTH, 1ST BALCONY, AND 2ND BALCONY ARE TO BE ROUTED THRU THE CHASE SPACE AVAILABLE AT THE BACK OF THE NEW WORSHIP CENTER NEAR THE REST ROOMS, STAIRS, ETC., DOWN BELOW THE UNDERFLOOR DUCT WORK BELOW THE SEATING IN THE MAIN LEVEL TO THE STAGE RACK LOCATION, RACK LOCATION IN THE PIT LEVEL, ELECTRICAL PANELS, SWITCHBOARD "MDP3", ETC. E.C. TO COORDINATE WITH PLUMBING AND HVAC CONTRACTORS PRIOR TO INSTALLING THE CONDUITS TO PREVENT CONFLICTS BETWEEN THE TRADES. 17 PROVIDE (3) SPARE 3" CONDUITS FROM GATHERING CENTER TO THE STAGE RACK LOCATION FOR FUTURE A/V REQUIREMENTS. COORDINATE WITH A/V CONSULTANT. 18 STAGE RIGGING SYSTEM - PROVIDE REQUIREMENTS PER PANEL SCHEDULE "RP3". COORDINATE ALL REQUIREMENTS WITH SHEETS TR1.0 AND TR2.0 PRIOR TO ROUGH-IN.