HomeMy WebLinkAboutE301-A - FIRST FLOOR - POWER PLAN - ALTERNATES
J
J
J
J
F
F
J
J
S
F
F
L
L
L
L
L
F
F
F
F
J
J
J
J
F
L
L
L
F
F
L
L
F
F
F
F
F
F
F
F
F
H H H
V V
V
W
SC SC SC
SC SC SC
SC
SC
SC
SC
SC
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
F
F F
L F
L
L
F
L
DN
UP
UP
DN
UP
UP
UP
F.E.C.
F.E.C.
F.E.C.
F.E.C.
DN
UP
GF
GF
AV
AV
AV
AV
AV
AV
TL1
AV
TL1
CAM
6
6
6
TL1
AV
CAM CAM
CAM
CAM
6
6
6
AV
AV
TL1
TL1
AV
AV
TL1
110 110
110
110
110
110
R
WP/GF
GF
GF
GF
GF
GF
AV
AV AV
AV
CAM
AV
CAM
AV
AV
CAM
AV
RPAV1 - 34
RPAV1 - 37
F E1
B
K L C1
L E1
G E1
G E1
RPAV1 - 12
RPAV1 - 13
G E1
G E1
RPAV1 - 14
RPAV1 - 15
B
F E1
G H J E1
RPAV1 - 16
RPAV1 - 17 RPAV1 - 18
RPAV1 - 19
G E1 G E1
G E1 G E1
RPAV1 - 20,22
VDB
RPAV1 - 21,23 RPAV1 - 24,26
E E E L E1
A
C C1
A
C1 C
PRJ PRJ
RPAV5-1-5
RPAV5-6-10
RPAV5-11-15
RPAV5-16-20
RPAV5-21-25
RPAV5 - 28
RPAV5 - 27
RPAV5 - 26
RPAV5 - 29 RPAV5 - 30
S5
AV
S5
AV
RPAV6 - 2
S5
AV
S5
AV
S5
AV
RPAV6 - 1
A
A
A
A
A C1
FB1
AV
RPAV6 - 6
FB1
AV
RPAV6 - 7
FB1
AV
RPAV6 - 8 FB1
AV
RPAV6 - 9
N C1
N C1 N C1
N C1
RPAV6 - 10,12
AV
C C1
RPAV6 - 11,13
AV
C C1
RPAV6 - 15,17
AV
C C1
RPAV6 - 14,16
C C1 AV
S4
S4
S4
S4
RPAV1 - 10
AV
6
RPAV1 - 25
RPAV1 - 11
AV
A A
RPAV1 - 29
RP2 - 15
RP2 - 16
RP2 - 17
RP2 - 18
RP2 - 19
RP2 - 20
RP2 - 21
RP2 - 22
RP2 - 23
RP2 - 24
RP2 - 25
RP2 - 26
RP2 - 27
RAP
REMOTE
ANNUNCIATOR
PANEL
RPAV1 - 39,41
AV
4
4 4
RPAV1 - 40,42
AV
4
RPAV1 - 40,42
6
EF-1
RP5 - 10
6
EF-1
RP5 - 9
CP-1
10
- <unnamed>
CP-2
10
RP1 - 39
UH-1
11
RP1 - 40
EF-5
6
MDP3 - 14
MDP3 - 15
RP2 - 2
RP2 - 28 RP2 - 3
6
9
9
RTU-4
RTU-3
A A
A A
A
A C1
C1 A
A
A
A
1 1 1
PRJ
3
6
3
3
2
5
5
EF-6
12
12
13
13
13
S-11
118
S-12
117 120
116
115
106
107
102
110
112
113
111
105
108
101
124
S-13
S-14
104
C-101
103
14 14
14
14
CPB
H C1
A H1
A H1
A H1
A H1
A H1
A H1
A H1
A H1
A H1
A H1
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A
A A
A
A
A
A
A
A
A
A
A A
A
A
A
A
A
A
A
A A A
A
A
A
A
15
15
GF
GF
GF
RP4 - 18,20,22
RP2 - 1
7
8
109
16
16
16
16
16
17
18
S8
S8
S8
S8
S8
S8
S8
S8
S8
S8
S8
S8
S8
S8
S8
S8
S8
S8
S8
S8
S8
S8
S8
S8
S8
S8
S8
S8
S8
S8
S8
S8
S8 S8
S8
S8
S8
S8
S8
S8
S8
S8
S8
S8
S8
S8
S8
S8
S8
S8
S8
S8
S8
S8
S8
RP5 - 17
RP5 - 16
RP4 - 21,23,25
11
UH-3
UH-3
11
DWH-2
Date: Scale
Drawn By
Checked By
Project
Number
ARCHITECTURE
PLANNING
INTERIOR DESIGN
STRUCTURAL ENGINEERING
424 East Fourth
Street
Cincinnati, w w w . c h a r c h Ohio i t e c t s . 45202 c o m
tel: 513/241/4474 fax: 513/241/0081
ISSUANCES
COMPUTER FILE
1400 West Dorothy Lane
Dayton, Ohio 45409-1310
Tel: (937) 224-0861
Fax: (937) 224-5777
3417 South Sherman Drive
Beech Grove, IN 46107
Tel: (317) 780-1555
Fax: (317) 780-6525
750 North Orleans, Suite 400
Chicago, IL 60610
Tel: (312) 944-8230
Fax: (312) 944-8297
117 East Washington
Street, Suite 200
Indianapolis, IN 46204
Tel: (317) 637-2222
Fax: (317) 637-2260
1137 West Taylor St.
Suite 316
Chicago, IL 60607
Tel: (312) 224-8460
Fax: (312) 224-8961
1025 N.Watery Ln.
Brigham City, UT 84302
TEL: (453) 723-5000
FAX: (453) 538-5506
6622 Kingspointe
Parkway
Orlando, FL 33819
Tel: (407) 816-9400
Fax: (407) 816-9300
1 SCHEMATIC DESIGN 10.18.07
2 DESIGN DEVELOPMENT 01.18.08
3 CD 50% 03.14.08
4 PERMIT SET 04.25.08
5 ADDENDUM #2 05.16.08
No. Description Date
6 ADDENDUM #3 05.22.08
7 ADDENDUM #5 06.04.08
8 PERMIT SET 06.10.08
1/8" = 1'-0"
6/10/2008 1:02:43 PM
C:\Drawings\2007-06019-Central-Local.rvt
E301-A
FIRST FLOOR -
POWER PLAN -
ALTERNATE
New Worship
Center
Checker
Author
05-22-08
2007-06019
1/8" = 1'-0"
1
POWER & SYSTEMS - LEVEL-1 - NEW
WORK - ALTERNATE
GENERAL NOTES
A E.C. TO COORDINATE WITH A/V DRAWINGS:
AV201, AV211, AV202, AV212, AV203, AV213, AV204, AV205, AV215, AV251, AV252, AV253,
AV301, AV302
FOR BOX TYPE, MOUNTING HEIGHT, EXACT LOCATION FOR A/V DEVICES AND A/V
EQUIPMENT AND ANY ADDITIONAL ELECTRICAL REQUIREMENTS PRIOR TO ROUGH-IN.
A/V CONSULTANT: CRAIG COMPTON
PRO-SOUND
PH: 407-816-9400
E-MAIL: CCOMPTON@PROSOUND.NET
PLAN NOTES
A/V CONDUIT NOTES
A (1) 3/4"C.
B (3) 1"C.
C (1) 1"C.
D (1) 2"C.
E (1) 1-1/2"C.
F (3) 1-1/2"C.
G (2) 1"C.
H (2) 2"C.
J (2) 4"C.
K (3) 4"C.
L (3) 2"C.
M (1) 1/2"C.
N (2) 1-1/4"C.
O (2) 1-1/2"C.
A1 TO VBB.
B1 TO A/V RACKS 023.
C1 TO A/V RACKS AT STAGE LOCATION.
D1 TO SBB.
E1 TO A/V RACKS 023 COMPUTER FLOOR.
F1 TO VDB-501.
G1 TO ADB-501.
H1 TO CPB.
101 ENTRANCE LOBBY
102 VESTIBULE
103 WORSHIP CENTER
104 SOUND BOOTH
105 CHAIR STORAGE/CATERING
106 VESTIBULE
107 VESTIBULE
108 MEN'S RESTROOM
109 JANITOR ROOM
110 WOMEN'S RESTROOM
111 WOMEN'S RESTROOM
112 VESTIBULE
113 VESTIBULE
115 STORAGE
116 WORKSHOP
117 SIDE PLATFORM
118 DELIVERY
119 PLATFORM
120 SIDE PLATFORM
124 JANITOR
C-101 CORRIDOR
S-11 STAIR-1
S-12 STAIR-2
S-13 STAIR-3
S-14 STAIR-4
ROOM INDEX
1 PROVIDE RECEPTACLE WITH NEMA CONFIGURATION - 6-20R. COORDINATE EXACT
REQUIREMENTS WITH A/V CONSULTANT PRIOR TO ROUGH-IN.
2 CABLE TRAY - 24" WIDTH x 4" DEPTH - CABLOFIL OR EQUAL. COORDINATE MOUNTING
HEIGHT AND OTHER REQUIREMENTS WITH A/V CONSULTANT PRIOR TO ROUGH-IN.
3 WIREMOLD TRENCH DUCT - 12" WIDTH x 4" DEPTH. LID TO BE CUSTOM MADE.
COORDINATE WITH ARCHITECT / A/V CONSULTANT FOR REQUIREMENTS.
4 PROVIDE SINGLE GANG BOX WITH 3/4" CONDUIT TO "CONTROL EQUIPMENT RACK" IN
BOOTH. PROVIDE BLANK COVERPLATE. DATA OUTLET AND CABLING BY OTHERS.
COORDINATE EXACT LOCATION AND MOUNTING HEIGHT WITH LIGHTING CONSULTANT /
SYSTEM INTEGRATOR PRIOR TO ROUGH-IN.
5 PROVIDE DUCT MOUNTED SMOKE DETECTORS ON THE RETURN DUCT FOR ROOFTOP
UNITS AND INTERFACE WITH FACP TO SHUT-DOWN UNITS UPON ALARM. COORDINATE
LOCATION WITH HVAC DRAWINGS.
6 EXHAUST FAN. PROVIDE ELECTRICAL ROUGH-IN AND FINAL CONNECTIONS. COORDINATE
LOCATION, CONTROL, AND OTHER ELECTRICAL REQUIREMENTS WITH HVAC DRAWINGS
WITH HVAC DRAWINGS.
7 ELECTRICAL WATER HEATER. PROVIDE FUSED DISCONNECT. PROVIDE ELECTRICAL ROUGH-IN
AND FINAL CONNECTIONS PER REQUIREMENTS. COORDINATE LOCATION WITH PLUMBING
DRAWINGS.
8 DEDICATED OUTLET WITH 120V, 20A CIRCUIT FOR RECIRCULATING PUMP FOR WATER HEATER.
COORDINATE LOCATION WITH PLUMBING DRAWINGS.
9 PROVIDE GFI/WP RECEPTACLE AND VAPORPROOF APPLETON LIGHT FIXTURE FOR ROOFTOP
UNITS. COORDINATE LOCATION WITH UNIT. PROVIDE WEATHERPROOF LIGHT SWITCH FOR
LIGHT FIXTURE.
10 COIL PUMP. PROVIDE COMBINATION STARTER AND SIZE PER REQUIREMENTS.
COORDINATE OTHER ELECTRICAL REQUIREMENTS WITH HVAC DRAWINGS.
11 UNIT HEATER. PROVIDE ELECTRICAL ROUGH-IN AND FINAL CONNECTIONS. COORDINATE
LOCATION, MOUNTING HEIGHT, AND OTHER ELECTRICAL REQUIREMENTS WITH HVAC
DRAWINGS.
12 CIRCUIT # RPAV6-2 FEEDS POWER OUTLETS IN THESE BOXES.
13 CIRCUIT # RPAV6-1 FEEDS POWER OUTLETS IN THESE BOXES.
14 PROVIDE SINGLE GANG BOX WITH 3/4" CONDUIT TO THE SERVER ROOM. PROVIDE A BLANK
COVER PLATE. RJ45 OUTLET AND CAT5 CABLING BY OTHERS. OVERALL LENGTH SHOULD
NOT EXCEED 285'.
15 PROVIDE FUSED DISCONNECT TYPE NEMA 3R FOR ROOF TOP UNIT AND WIRE PER
REQUIREMENTS.
16 CONDUITS FROM MAIN LEVEL, BOOTH, 1ST BALCONY, AND 2ND BALCONY ARE TO BE ROUTED
THRU THE CHASE SPACE AVAILABLE AT THE BACK OF THE NEW WORSHIP CENTER NEAR THE
REST ROOMS, STAIRS, ETC., DOWN BELOW THE UNDERFLOOR DUCT WORK BELOW THE
SEATING IN THE MAIN LEVEL TO THE STAGE RACK LOCATION, RACK LOCATION IN THE PIT
LEVEL, ELECTRICAL PANELS, SWITCHBOARD "MDP3", ETC. E.C. TO COORDINATE WITH
PLUMBING AND HVAC CONTRACTORS PRIOR TO INSTALLING THE CONDUITS TO PREVENT
CONFLICTS BETWEEN THE TRADES.
17 PROVIDE (3) SPARE 3" CONDUITS FROM GATHERING CENTER TO THE STAGE RACK LOCATION
FOR FUTURE A/V REQUIREMENTS. COORDINATE WITH A/V CONSULTANT.
18 STAGE RIGGING SYSTEM - PROVIDE REQUIREMENTS PER PANEL SCHEDULE "RP3".
COORDINATE ALL REQUIREMENTS WITH SHEETS TR1.0 AND TR2.0 PRIOR TO ROUGH-IN.