HomeMy WebLinkAboutE302 - BALCONY ONE - POWER PLANF
F
F
F
F
J
J
J
J
S
J
J
J
J
F
F
F
V
W
SC SC SC
SC SC SC
H S
V
DN
UP
DN
UP
DN
DN
UP
UP
AV
AV
AV
AV AV
AV
AV
AV AV
PRJ
AV
TL1
6
AV
AV
TL1
6
AV
AV
AV
AV
AV
7
6
7 6
6
6
7
6
6
7
6
7
6
AV
TL1
TL1
AV
AC-2
AC-1
2
1
3
GF
R
V1 AV
RPAV2 - 1
RPAV2 - 2
RPAV2 - 3
A G E1
A C E1
A G E1
A G E1
A G E1
RPAV2 - 6,8 RPAV2 - 7,9 RPAV2 - 10,12
E F1 E F1 E F1
PRJ PRJ
A C1
A
A A
A
C C1
A
A
A
A
A
A
C C1 RPAV2 - 11
RPAV2 - 13
RPAV2 - 14
RPAV2 - 15
RPAV2 - 16
RPAV2 - 17
RP1 - 5
RP1 - 6
RP1 - 7
RP1 - 8
RP1 - 9
5
MDP3 - 16
EP - 16
EP - 17
RP5 - 11
EF-4
EF-3
RP5 - 12
MDP3 - 17
RP5 - 13
GF/WP
RTU-1
RP5 - 14
GF/WP
MDP3 - 18
RP4 - 27,29
RP4 - 30,32
4 4 4
6 (TYP.)
A A
A A
A
A C1
7 7
7
221
200
S-21 S-22
S-23
203
201
204
202
S-24
8 8
10 11
7 10 11
9 9
12
R R
13 13
WP
WP
Date: Scale
Drawn By
Checked By
Project
Number
ARCHITECTURE
PLANNING
INTERIOR DESIGN
STRUCTURAL ENGINEERING
424 East Fourth
Street
Cincinnati, w w w . c h a r c h Ohio i t e c t s . 45202 c o m
tel: 513/241/4474 fax: 513/241/0081
ISSUANCES
COMPUTER FILE
1400 West Dorothy Lane
Dayton, Ohio 45409-1310
Tel: (937) 224-0861
Fax: (937) 224-5777
3417 South Sherman Drive
Beech Grove, IN 46107
Tel: (317) 780-1555
Fax: (317) 780-6525
750 North Orleans, Suite 400
Chicago, IL 60610
Tel: (312) 944-8230
Fax: (312) 944-8297
117 East Washington
Street, Suite 200
Indianapolis, IN 46204
Tel: (317) 637-2222
Fax: (317) 637-2260
1137 West Taylor St.
Suite 316
Chicago, IL 60607
Tel: (312) 224-8460
Fax: (312) 224-8961
1025 N.Watery Ln.
Brigham City, UT 84302
TEL: (453) 723-5000
FAX: (453) 538-5506
6622 Kingspointe
Parkway
Orlando, FL 33819
Tel: (407) 816-9400
Fax: (407) 816-9300
1 SCHEMATIC DESIGN 10.18.07
2 DESIGN DEVELOPMENT 01.18.08
3 CD 50% 03.14.08
4 PERMIT SET 04.25.08
5 ADDENDUM #2 05.16.08
No. Description Date
6 ADDENDUM #3 05.22.08
7 ADDENDUM #5 06.04.08
8 PERMIT SET 06.10.08
1/8" = 1'-0"
6/10/2008 1:03:03 PM
C:\Drawings\2007-06019-Central-Local.rvt
E302
BALCONY ONE -
POWER PLAN
New Worship
Center
Checker
Author
05-22-08
2007-06019
1/8" = 1'-0"
1
POWER & SYSTEMS - BALCONY ONE -
NEW WORK
GENERAL NOTES
A E.C. TO COORDINATE WITH A/V DRAWINGS:
AV201, AV211, AV202, AV212, AV203, AV213, AV204, AV205, AV215, AV251, AV252, AV253,
AV301, AV302
FOR BOX TYPE, MOUNTING HEIGHT, EXACT LOCATION FOR A/V DEVICES AND A/V
EQUIPMENT AND ANY ADDITIONAL ELECTRICAL REQUIREMENTS PRIOR TO ROUGH-IN.
A/V CONSULTANT: CRAIG COMPTON
PRO-SOUND
PH: 407-816-9400
E-MAIL: CCOMPTON@PROSOUND.NET
PLAN NOTES
1 PROVIDE 240V, 1P, 30A FUSED DISCONNECT WITH 20A FUSE AND 120V, 20A DEDICATED
CIRCUIT FOR ELEVATOR CAB LIGHT. PROVIDE WIRING TO ELEVATOR CONTROLLER PER
MANUFACTURER'S REQUIREMENTS.
2 PROVIDE BUSSMAN POWER MODULE SWITCH WITH SHUNT-TRIP CONTROL.
TRANSFORMER WITH FUSES AND BLACKS, FIRE SAFETY INTERFACE RELAY,
MECHANICALLY INTERLOCKED AUXILIARY CONTACT, FIRE ALARM VOLTAGE
MONITORING RELAY IN NEMA 1 ENCLOSURE. PROVIDE ELEVATOR POWER CIRCUIT
#MDP3-_ (208V, 3PH, 60HZ, 30HP). COORDINATE EXACT SWITCH SIZE WITH ELEVATOR
EQUIPMENT SUPPLIER PRIOR TO ROUGH-IN.
3 PROVIDE 120V, 20A GFCI RECEPTACLE IN THE ELEVATOR EQUIPMENT ROOM (46"M.H.).
4 PROVIDE RECEPTACLE WITH NEMA CONFIGURATION - 6-20R. COORDINATE EXACT
REQUIREMENTS WITH A/V CONSULTANT PRIOR TO ROUGH-IN.
5 SINGLE GANG BOX WITH 3/4" CONDUIT TO "CONTROL EQUIPMENT RACK" IN CATWALK.
PROVIDE BLANK COVER PLATE. DATA OUTLET AND CABLE BY OTHERS. INTENT IS TO
MOUNT BOX ON FACE OF BALCONY FLOOR. COORDINATE EXACT LOCATION AND
MOUNTING HEIGHT WITH LIGHTING CONSULTANT / SYSTEM INTEGRATOR PRIOR TO
ROUGH-IN.
6 INTENT IS TO MOUNT SPEAKERS CENTERED WITH BEAM (TYPICAL OF 5 SPEAKERS).
COORDINATE EXACT LOCATION WITH A/V CONSULTANT PRIOR TO ROUGH-IN.
7 PROVIDE DUCT MOUNTED SMOKE DETECTOR ON RETURN DUCT AND INTERFACE WITH
FACP TO SHUT-DOWN UNIT UPON ALARM.
8 PROVIDE SINGLE GANG BOX WITH 3/4" CONDUIT TO THE SERVER ROOM. PROVIDE A BLANK
COVER PLATE. RJ45 OUTLET AND CAT5 CABLING BY OTHERS. OVERALL LENGTH SHOULD
NOT EXCEED 285'.
9 AIR CONDITIONING UNIT. MOUNT FUSED DISCONNECT ON THE UNIT AND WIRE PER
REQUIREMENTS. SEE HVAC DRAWINGS FOR LOCATION AND MOUNTING ARRANGEMENT.
10 ROOFTOP UNIT. PROVIDE FUSED DISCONNECT NEMA 3R AND WIRE PER REQUIREMENTS.
COORDINATE LOCATION WITH HVAC DRAWINGS.
11 PROVIDE GFI/WP RECEPTACLE AND VAPORPROOF APPLETON LIGHT FIXTURE FOR
ROOFTOP UNIT. PROVIDE WEATHERPROOF LIGHT SWITCH.
12 EXHAUST FAN. PROVIDE ELECTRICAL ROUGH-IN AND FINAL CONNECTIONS. COORDINATE
WITH HVAC DRAWINGS FOR LOCATION AND CONTROLS.
13 CONDUITS FROM MAIN LEVEL, BOOTH, 1ST BALCONY, AND 2ND BALCONY ARE TO BE
ROUTED THRU THE CHASE SPACE AVAILABLE AT THE BACK OF THE NEW WORSHIP CENTER
NEAR THE REST ROOMS, STAIRS, ETC., DOWN BELOW THE UNDERFLOOR DUCT WORK
BELOW THE SEATING IN THE MAIN LEVEL TO THE STAGE RACK LOCATION, RACK LOCATION
IN THE PIT LEVEL, ELECTRICAL PANELS, SWITCHBOARD "MDP3", ETC. E.C. TO COORDINATE
WITH PLUMBING AND HVAC CONTRACTORS PRIOR TO INSTALLING THE CONDUITS TO
PREVENTCONFLICTS BETWEEN THE TRADES.
A/V CONDUIT NOTES
A (1) 3/4"C.
B (3) 1"C.
C (1) 1"C.
D (1) 2"C.
E (1) 1-1/2"C.
F (3) 1-1/2"C.
G (2) 1"C.
H (2) 2"C.
J (2) 4"C.
K (3) 4"C.
L (3) 2"C.
M (1) 1/2"C.
N (2) 1-1/4"C.
O (2) 1-1/2"C.
A1 TO VBB.
B1 TO A/V RACKS 023.
C1 TO A/V RACKS AT STAGE LOCATION.
D1 TO SBB.
E1 TO A/V RACKS 023 COMPUTER FLOOR.
F1 TO VDB-501.
G1 TO ADB-501.
H1 TO CPB.
200 BALCONY-1
201 VESTIBULE
202 CRYING ROOM
203 MACHINE ROOM
204 MEZZANINE
221 PROJECTION ROOM
S-21 STAIR-1
S-22 STAIR-2
S-23 STAIR-3
S-24 STAIR-4
ROOM INDEX