HomeMy WebLinkAboutE303 - BALCONY TWO - POWER PLANJ
J
J
F
F
F
F
F
W
V
S
F
F
F
F
F
S
F
DN
UP
DN
DN DN
UP
AV
6
TL1
6
AV
AV
CAM
CAM
CAM
6
AV TL1
AV
AV
TL1
AV
6
RPAV2 - 4
AV
RPAV2 - 18
AV
RPAV2 - 19
AV
RPAV2 - 20
B E1
G E1
G E1
G E1
B E1
B E1
A C1
A A
A C1
RPAV2 - 21
RPAV2 - 24
RPAV2 - 22
RPAV2 - 23
RP1 - 1
RP1 - 2
RP1 - 3
RP1 - 4
1
221
300
301
S-34 S-33
2 2
3 3
Date: Scale
Drawn By
Checked By
Project
Number
ARCHITECTURE
PLANNING
INTERIOR DESIGN
STRUCTURAL ENGINEERING
424 East Fourth
Street
Cincinnati, w w w . c h a r c h Ohio i t e c t s . 45202 c o m
tel: 513/241/4474 fax: 513/241/0081
ISSUANCES
COMPUTER FILE
1400 West Dorothy Lane
Dayton, Ohio 45409-1310
Tel: (937) 224-0861
Fax: (937) 224-5777
3417 South Sherman Drive
Beech Grove, IN 46107
Tel: (317) 780-1555
Fax: (317) 780-6525
750 North Orleans, Suite 400
Chicago, IL 60610
Tel: (312) 944-8230
Fax: (312) 944-8297
117 East Washington
Street, Suite 200
Indianapolis, IN 46204
Tel: (317) 637-2222
Fax: (317) 637-2260
1137 West Taylor St.
Suite 316
Chicago, IL 60607
Tel: (312) 224-8460
Fax: (312) 224-8961
1025 N.Watery Ln.
Brigham City, UT 84302
TEL: (453) 723-5000
FAX: (453) 538-5506
6622 Kingspointe
Parkway
Orlando, FL 33819
Tel: (407) 816-9400
Fax: (407) 816-9300
1 SCHEMATIC DESIGN 10.18.07
2 DESIGN DEVELOPMENT 01.18.08
3 CD 50% 03.14.08
4 PERMIT SET 04.25.08
5 ADDENDUM #2 05.16.08
No. Description Date
6 ADDENDUM #3 05.22.08
7 ADDENDUM #5 06.04.08
8 PERMIT SET 06.10.08
1/8" = 1'-0"
6/10/2008 1:03:35 PM
C:\Drawings\2007-06019-Central-Local.rvt
E303
BALCONY TWO -
POWER PLAN
New Worship
Center
Checker
Author
05-22-08
2007-06019
1/8" = 1'-0"
1
POWER & SYSTEMS - BALCONY TWO -
NEW WORK
GENERAL NOTES
A E.C. TO COORDINATE WITH A/V DRAWINGS:
AV201, AV211, AV202, AV212, AV203, AV213, AV204, AV205, AV215, AV251, AV252, AV253,
AV301, AV302
FOR BOX TYPE, MOUNTING HEIGHT, EXACT LOCATION FOR A/V DEVICES AND A/V
EQUIPMENT AND ANY ADDITIONAL ELECTRICAL REQUIREMENTS PRIOR TO ROUGH-IN.
A/V CONSULTANT: CRAIG COMPTON
PRO-SOUND
PH: 407-816-9400
E-MAIL: CCOMPTON@PROSOUND.NET
PLAN NOTES
1 SINGLE GANG BOX WITH 3/4" CONDUIT TO "CONTROL EQUIPMENT RACK" IN CATWALK.
PROVIDE BLANK COVER PLATE. DATA OUTLET AND CABLE BY OTHERS. INTENT IS TO
MOUNT BOX ON FACE OF BALCONY FLOOR. COORDINATE EXACT LOCATION AND
MOUNTING HEIGHT WITH LIGHTING CONSULTANT / SYSTEM INTEGRATOR PRIOR TO
ROUGH-IN.
2 PROVIDE SINGLE GANG BOX WITH 3/4" CONDUIT TO THE SERVER ROOM. PROVIDE A
BLANK COVER PLATE. RJ45 OUTLET AND CAT5 CABLING BY OTHERS. OVERALL
LENGTH SHOULD NOT EXCEED 285'.
3 CONDUITS FROM MAIN LEVEL, BOOTH, 1ST BALCONY, AND 2ND BALCONY ARE TO BE
ROUTED THRU THE CHASE SPACE AVAILABLE AT THE BACK OF THE NEW WORSHIP
CENTER NEAR THE REST ROOMS, STAIRS, ETC., DOWN BELOW THE UNDERFLOOR
DUCT WORK BELOW THE SEATING IN THE MAIN LEVEL TO THE STAGE RACK LOCATION,
RACK LOCATION IN THE PIT LEVEL, ELECTRICAL PANELS, SWITCHBOARD "MDP3", ETC.
E.C. TO COORDINATE WITH PLUMBING AND HVAC CONTRACTORS PRIOR TO
INSTALLING THE CONDUITS TO PREVENT CONFLICTS BETWEEN THE TRADES.
A/V CONDUIT NOTES
A (1) 3/4"C.
B (3) 1"C.
C (1) 1"C.
D (1) 2"C.
E (1) 1-1/2"C.
F (3) 1-1/2"C.
G (2) 1"C.
H (2) 2"C.
J (2) 4"C.
K (3) 4"C.
L (3) 2"C.
M (1) 1/2"C.
N (2) 1-1/4"C.
O (2) 1-1/2"C.
A1 TO VBB.
B1 TO A/V RACKS 023.
C1 TO A/V RACKS AT STAGE LOCATION.
D1 TO SBB.
E1 TO A/V RACKS 023 COMPUTER FLOOR.
F1 TO VDB-501.
G1 TO ADB-501.
H1 TO CPB.
300 BALCONY-2
301 ELEVATOR VESTIBULE
S-33 STAIR-3
S-34 STAIR-4
ROOM INDEX