Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
E400 - SINGLE-LINE DISTRIBUTION DIAGRAM
SCALE: NONE E N ATS #1 N E G PER NEC 695 - CONNECTION LOCATED AHEAD OF MSB AND NOT WITHIN THE 'MSB' ENCLOSURE CABLES TO BE RUN BELOW THE BUILDING ENVELOPE PER NEC REQUIREMENTS. GENERATOR SET START AND STOP SIGNAL WIRING EXISTING SERVICE NEW NEW M SIZE CONDUIT GROUND SIZE FEEDER FEEDER SIZE: SPEC. REFERENCE NO.: NAMEPLATE UNIT NO. SWITCH OR SIZE BREAKER POLES TRIP SIZE VOLTAGE: DEMAND LOAD: CONNECTED LOAD: OVERCURRENT PROTECTION MAIN BUSSING: WIRE SIZE APPROX. CONNECTED KVA LOAD SEE NOTE NUMBER OF CONDUCTORS 3000A - - 120/208V, 3PH, 4WIRE 1 BOLTED PRESSURE MAIN - - - - MAIN SWITCHBOARD "MDP3" WITH GFP 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 SERVICE SPD ATS #1 ROOF TOP UNIT #1 ROOF TOP UNIT #2 ROOF TOP UNIT #3 ROOF TOP UNIT #4 HOTWATER PUMP #1 HOTWATER PUMP #2 HOTWATER PUMP #3 HOTWATER PUMP #4 ELEVATOR STAGE LIFT PANEL "RP1" PANEL "RP2" PANEL "RP3" PANEL "RP4" PANEL "THL1" PANEL "THL2" PANEL "THL3" PANEL "THL4" PANEL "THL5" PANEL "THL6" PANEL "THL7" TRANSFORMER DP #1 DP #2 PANEL "LP2" 30 31 32 33 34 PANEL "LP1" PANEL "EP" SPARE SPARE SPARE 30.0 140.0 75.0 155.0 70.0 3.0 3.0 9.0 9.0 30.0 11.0 40.0 40.0 42.0 48.0 60 100 450 250 450 225 20 20 40 40 150 50 200 200 200 200 200 200 200 200 200 200 200 800 200 200 200 200 200 100 100 200 200 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 - - - 60 150 450 250 450 225 20 20 40 40 150 50 200 200 200 200 200 200 200 200 200 200 200 800 200 200 200 200 200 100 100 200 200 3 4 4 4 2 SETS - 4 #4/0 AND 4 3 3 3 3 3 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 6 2/0 600 250 4/0 12 12 8 6 3/0 6 3/0 3/0 3/0 3/0 250 250 250 250 250 250 250 250 250 250 3/0 3/0 10 3 3 4 4 12 12 10 10 6 10 6 6 6 6 3 3 3 3 3 3 3 3 3 3 6 6 1 #2 IN 2.5"C EACH SET 2 SETS - 3 #400 AND 1 #1/0 IN 3"C EACH SET 100.0 7 SETS - 4#600 IN 3.5"C CONDUIT EACH SET +(2) SPARE 3.5" CONDUITS 0.75 2.0 4.0 2.5 2.5 - 0.75 0.75 0.75 0.75 2.0 1.5 2.5 2.5 2.5 2.5 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 2.5 2.5 GFP SPD VFD VFD ELEV. RTU#1 SERVICE 3000A, 208/120V-3PH-4W SWBD METERING POWER MODULE UTILITY PRIMARY ELECTRICAL FEEDER POWER COMPANY PAD MOUNTED TRANSFORMER 12.47 KV/208/120V-3PH-4W ELEC. METER PER UTILITY REQUIREMENT TRANSITION CABINET TO EXISTING SWITCHBOARD 'MDP' TO EXISTING SWITCHBOARD 'MDP2' EXISTING SUPPLY RTU#1 RETURN RTU#2 SUPPLY RTU#2 RETURN RTU#3 SUPPLY RTU#3 RETURN VFD VFD RTU#4 SUPPLY RTU#4 RETURN HWP#1 HWP#2 4 BUSSMANN SWITCH 20HP (2) 5HP 15HP 7-1/2HP (2) 20HP (2) 7-1/2HP 10HP 5HP VFD VFD HWP#3 HWP#4 2HP 2HP 7-1/2HP 7-1/2HP 30HP VFD VFD VFD VFD STAGE LIFT 10HP STARTER CABINET EMERGENCY GENERATOR WITH AUTO. TRANFER SWITCH FIRE PUMP CONTROLLER PUMP FIRE 208/120V STAND-BY 60KW NATURAL GAS 400/300 B B A B (FP1) 110/3 100/3 100/3P, 4 WIRE 30HP EBP RPAV1 RPAV2 RPAV3 RPAV4 RPAV5 RPAV6 RP1 2 3 5 6 7 8 9 10 11 12 13 14 RP2 15 RP3 16 RP4 17 THL1 18 THL2 19 THL3 20 THL4 21 THL5 22 THL6 23 24 34 33 31 LP1 30 LP2 29 28 DP#1 27 DP#2 26 25 11 10 9 8 7 6 5 4 3 2 1 PRIMARY : 208V, 3Ph., Delta SECONDARY: 208V, 3 Ph., Wye ISOLATION TRANSFORMER FOR A/V APPLICATION ONLY SPARE SPARE SPARE SPARE SPARE SPARE 1 60 100 450 250 450 225 20 20 40 40 150 50 200 200 200 200 200 200 200 200 200 200 200 200 100 200 200 200 200 200 200 800 225KVA 100 100 200 200 200 200 200 200 200 200 800A, 208/120V-3PH-4W DP#3 THL7 RP5 35 SPARE 200 (OPTIO 9) (OPTIO 9) (CAPIO) (PLUS) A PANEL "RP5" 48.0 200 3 200 4 3/0 6 2.5 35 DPH3 1 2 3 4 5 6 7 8 9 10 11 12 13 20 19 18 17 16 15 28 27 26 25 24 23 22 14 36 35 34 33 10757 8163 8163 8163 8163 8163 8163 21 22 23 24 25 26 27 28 29 30 31 32 29445 29445 10044 10044 10044 13454 13454 13454 20 19 18 17 16 15 14 13 12 11 10 13454 9 13454 8 13454 5 23096 7 23096 6 23096 4 27158 3 27158 2 41894 1 48331 AVAILABLE SHORT CIRCUIT AMPS POINT REF. DESCRIPTION SECONDARY - SERVICE TRANSFORMER MAIN SWITCHBOARD 'MDP3' PANEL 'RP2' PANEL 'RP3' PANEL 'RP4' PANEL 'RP5' PANEL 'THL1' PANEL 'THL2' PANEL 'RP1' PANEL 'THL3' PANEL 'THL4' PANEL 'THL5' PANEL 'THL6' PANEL 'THL7' DIMMER RACK DP#3 XFMR 225KVA PRIMARY DIMMER RACK DP#2 DIMMER RACK DP#1 PANEL 'LP2' PANEL 'LP1' XFMR 225KVA SECONDARY PANEL 'RPAV6' PANEL 'RPAV5' PANEL 'RPAV4' PANEL 'RPAV3' PANEL 'RPAV2' PANEL 'RPAV1' 13454 35824 21 9702 DISTRIBUTION PANEL 'DPL1' PANEL 'EP' 27158 29 EXISTING EXISTING EXISTING WP WP WP WP 32 100 EP TRANSFER SWITCH TO RELAY LOADS TO DIMMING LOADS 4 1 8 1.5 EMERGENCY UC700 TRANSFER SWITCH EMERGENCY UC700 A - 4#2/0, 1#3 IN 2" C. B - 3#2/0, 1#3 IN 2" C. ELECTRIC SINGLE-LINE DISTRIBUTION DIAGRAM FAULT CURRENT SCHEDULE MAIN SWITCHBOARD 'MDP3' DISTRIBUTION PANEL "DPL1 Date: Scale Drawn By Checked By Project Number ARCHITECTURE PLANNING INTERIOR DESIGN STRUCTURAL ENGINEERING 424 East Fourth Street Cincinnati, w w w . c h a r c h Ohio i t e c t s . 45202 c o m tel: 513/241/4474 fax: 513/241/0081 ISSUANCES COMPUTER FILE 1400 West Dorothy Lane Dayton, Ohio 45409-1310 Tel: (937) 224-0861 Fax: (937) 224-5777 3417 South Sherman Drive Beech Grove, IN 46107 Tel: (317) 780-1555 Fax: (317) 780-6525 750 North Orleans, Suite 400 Chicago, IL 60610 Tel: (312) 944-8230 Fax: (312) 944-8297 117 East Washington Street, Suite 200 Indianapolis, IN 46204 Tel: (317) 637-2222 Fax: (317) 637-2260 1137 West Taylor St. Suite 316 Chicago, IL 60607 Tel: (312) 224-8460 Fax: (312) 224-8961 1025 N.Watery Ln. Brigham City, UT 84302 TEL: (453) 723-5000 FAX: (453) 538-5506 6622 Kingspointe Parkway Orlando, FL 33819 Tel: (407) 816-9400 Fax: (407) 816-9300 1 SCHEMATIC DESIGN 10.18.07 2 DESIGN DEVELOPMENT 01.18.08 3 CD 50% 03.14.08 4 PERMIT SET 04.25.08 5 ADDENDUM #2 05.16.08 No. Description Date 6 ADDENDUM #3 05.22.08 7 ADDENDUM #5 06.04.08 8 PERMIT SET 06.10.08 6/10/2008 1:04:08 PM C:\Drawings\2007-06019-Central-Local.rvt E400 SINGLE-LINE DISTRIBUTION DIAGRAM New Worship Center Checker Author 05-22-08 2007-06019