HomeMy WebLinkAboutF301TYPICAL WALL OR GRADE BEAM CORNER CORNER BARS SIZE AND SPACING AS MAIN HORIZONTAL WALL REINFORCING STEEL. PROVIDE 3-#4 VERTICAL SUPPORT BARS WHEN MAIN REINFORCING IS IN ONE FACE ONLY. NOTE: MAIN WALL REINF. NOT SHOWN 2' - 6" 2' - 6" 1'-0" TYPICAL THICKENED FOOTING AT UTILITY PIPE PENETRATION MIN. REINFORCING: SAME SIZE AND QUANTITY AS TYPICAL WALL FOOTING REINFORCEMENT 1' - 0" 1' - 0" MIN. 1' - 6" MIN. TYPICAL FOOTING REINF. SLEEVE THRU FOOTING TO BE LARGER THAN UTILITY PIPE TO ALLOW FOR 1" VERTICAL DOWNWARD DEFLECTION OF FOOTING REINF. TO MATCH REINF. OF FOOTING MAX. U.N.O. 2' - 0" 1' - 6" 1' - 6" 4'-0" MIN. TO NEXT STEP OR INTERSECTING FTG. U.N.O. SAME THICKNESS AS FOOTING TYPICAL STEP FOOTING TYPICAL WALL OR GRADE BEAM INTERSECTION 2' - 6" 2' - 6" INTERSECTION BARS SAME SIZE AND SPACING AS MAIN HORIZONTAL WALL REINFORCING STEEL NOTE: MAIN WALL REINF. NOT SHOWN 1 1/2" CL TYPICAL OPENING IN CONCRETE WALL CONST. JOINT OR TOP OF CONC. 2-#6 TTOP & BOT. OVER OPENINGS NOT OTHERWISE COVERED. BARS 6'-0" LONGER THAN WIDTH OF OPENING. 2-#5 FULL HEIGHT OF WALL EA. SIDE OF OPENING. 1EA. FACE 2-#6 UNDER OPENING. BARS 6'-0" LONGER THAN OPENING 2-#5 x 5'-0" DIAG. AT EA. CORNER 1 EA. FACE NOTE: FOR OPENINGS GREATER THAN 2'-6" EITHER DIRECTION TYPICAL REALATION OF UTILITY TRENCH TO BUILDING FOUNDATIONS UTILITY TRENCH 1) CONTRACTOR SHALL COORDINATE FOOTING ELEVATIONS GIVEN ON DRAWINGS WITH UTILITY CONTRACTOR FOR CONFORMITY TO THIS REQUIREMENT. BEFORE POURING ANY FOOTINGS, REPORT ANY DISC REPANCIES TO THE ENGINEER BEFORE PROCEEDING 2) WHEN UTILITY PENETRATES FOOTING, FOOTING SHALL BE THICKNENED, SO UTILITIES PASS TRHROUGH FOOTING WITH A MINIMUM SLEEVE CLEARANCE TO ALLOW 1" VERTICAL DOWNWARD DEFLECTION OF FOOTING - SEE TYPICAL DETAIL 3) WHEN UTILITIES PASS THROUGH A FOUNDATION WALL, PROVIDE A MINIMUM SLEEVE CLEARANCE TO ALLOW 1" VERTICAL DOWNWARD DEFLECTION OF FOUNDATION WALL 4) FOOTINGS SHALL NEVER PASS OVER THE TOP OF A UTILITY TRENCH UNLESS APPROVED BY ENGINEER UTILITY TRENCH WALL OR COLUMN FOOTING D x 2 D SEE FOUNDATION PLAN FOR SIZE AND REINFORCING 3" COVER 3" COVER TYPICAL COLUMN FOOTING WITH PEDESTAL SEE FRAMING PLAN FOR COLUMN SIZE SEE PLAN DETAILS FOR REINFORCING. SEE DRWGS. BY GEM BUILDINGS FOR ANCHOR BOLT QUANTITY, SIZE AND LAYOUT. SEE FOUNDATION PLAN FOR PLAN DETAILS OF COLUMN PEDESTALS. 2" NON-SHRINK GROUT - TYP. VERIFY W/ GEM BUILDINGS SEE FOUNDATION PLAN FOR SIZE AND REINFORCING SEE PLAN SEE PLAN 3" COVER 3" COVER SEE FRAMING PLAN FOR COLUMN SIZE TYPICAL COLUMN FOOTING WITHOUT PEDESTAL 2" NON-SHRINK GROUT - TYP. VERIFY W/ GEM BUILDINGS SEE DWGS BY GEM BUILDINGS FOR ANCHOR BOLT QUANTITY, SIZE AND LAUOUT. TYPICAL BOX-OUT IN SLAB AT FOOTING C. J. TYPICAL FROM EDGE OF COL. BASE PLATE BOTTOM EDGE OF BOX OUT POUR 3" W W+8 6" TYPICAL THICKENED SLAB UNDER NON-LOAD BEARING MASONARY PARTITIONS 2-#4 CONT. CENTER ON WALL LOCATE JOINT IN SLAB UNDER THRESHOLD - SEE ARCHITECTURAL DWG'S SLOPE EXTERIOR SLAB -SEE ARCHITECTURAL DWGS. CONTRACTOR HAS OPTION TO FIELD BEND SLAB DOWELS #4 DOWELS @ 18" c/c EA. FACE SEE FOUNDATION DETAILS FOR WALL THICKNESS & REINFORCEMENT TYP. TYP. 2' - 0" 2' - 0" 8" TYPICAL HOLD DOWN IN CONCRETE WALL OR GRADE BEAM AT DOOR THICKNESS "t" SLAB THICKNESS "t" SLAB x 1/8" WIDE - SAWCUT t/4 DEEP MESH - PLACE IN CENTER OF SLAB THICKNESS CUT EVERY OTHER WIRE AT JOINT 3/4"x14" SMOOTH DOWEL @ 12" c/c GREASE ONE END PLACE IN CENTER OF SLAB THICKNESS 1/8" WIDE x 1/2" DEEP SAW CUT WHERE JOINT FILLER IS SPECIFIED TYPICAL SLAB ON GRADE CONTROL JOINT TYPICAL CONSTRUCTION JOINT IN SLAB ON GRADE x x x x x x x x x GENERAL NOTES: CODE: THE 2003 INDIANA BUILDING CODE, LATEST REVISION DESIGN LOADS: THE DESIGN OF ALL STRUCTURAL STEEL FRAMING, STEEL DECK, CONCRETE SLABS ON STEEL DECK AND ANCHOR BOLT DIAMETERSARE THE RESPONSIBILITY OF GEM BUILDINGS. ALL COLUMN FOUNDATIONS, ANCHOR BOLT EMBEDMENTS AND STRUCTURAL STEEL EMBEDMENTS THAT SUPPORT STEEL BEAMS AND STEEL DECK THAT ATTACHES TO CONCRETE WALLS ARE DESIGNED FOR THE FRAMING REACTIONS THAT ARE DETERMINED AND PROVIDED BY GEM BUILDINGS. DESIGN CRITERIA FOR THE ESTABLISHMENT OF THESE COLUMN LOADS ARE LISTED ON THE DRAWINGS BY GEM BUILDINGS. RETAINING WALLS AND RETAINING WALL FOOTINGS ARE DESIGNED FOR THE FOLLOWING DESIGN CRITERIA THAT IS DEFINED IN THE SOILS REPORT BY PATRIOT ENGINEERING AND ENVIRONMENTAL, INC., PATRIOT PROJECT NO. 1-07-0690, WHICH IS INCLUDED IN THE PROJECT SPECIFICATIONS: CANTILEVERED RETAINING WALLS ARE DESIGNED FOR AN EQUIVALENT ACTIVE FLUID PRESSURE EQUAL TO 38 psf. FIXED RETAINING WALLS ARE DESIGNED FOR AN EQUIVALENT AT-REST FLUID PRESSURE EQUAL TO 57 PSF. THE FLUID PRESSURES INCREASE LINEARLY FROM ZERO AT GROUND SURFACE TO A MAXIMUM AT THE BASE OF THE WALL. COEFFICIENT OF FRICTION AGAINST SLIDING EQUAL TO 0.3. SEISMIC DESIGN CRITERIA: SITE CLASS C Ss = 0.176 S1 = 0.088 SDs = 0.141 SD1 = 0.101 SEISMIC DESIGN CATEGORY B FOUNDATIONS: FOOTINGS SHALL BEAR ON NATURAL, STIFF, UNDISTURBED SOILS OR ENGINEERED COMPACTED FILL AS DEFINED IN THE SOILS REPORT BY PATRIOT ENGINEERIING AND ENVIRONMENTAL, INC., PATRIOT PROJECT NO. 1-07-0690, INCLUDED IN THE CONTRACT SPECIFICATIONS. FOUNDATIONS ARE DESIGNED FOR THE MAXIMUM ALLOWABLE SOILS BEARING PRESSURES STATED IN THE SOILS REPORT WHICH ARE: COLUMN FOOTINGS: 2,750 psf. WALL FOOTINGS: 2,250 psf. ALL FOOTING EXCAVATIONS SHALL BE INSPECTED BY A LICENSED SOILS ENGINEER BEFORE CONCRETE FOR FOOTINGS IS POURED. CONCRETE: ALL CONCRETE CONSTRUCTION SHALL CONFORM TO THE BUILDING CODE REQUIREMENTS OF THE AMERICAN CONCRETE INSTITUTE. 28 DAY CONCRETE COMPRESSIVE STRENGTH SHALL BE: FOOTINGS: 3,000 psi. INTERIOR SLABS ON GRADE, FOUNDATION WALLS AND GRADE BEAMS: 4,000 psi. EXTERIOR SLABS ON GRADE AND EXTERIOR WALLS EXPOSED ABOVE GRADE: 4,500 psi., AIR-ENTRAINED 6% PLUS OR MINUS 1.5% REINFORCING STEEL SHALL BE ASTM A 615, GRADE 60 WELDED WIRE FABRIC SHALL BE ASTM A 185. PROVIDE REINFORCING STEEL SHOP DRAWINGS DETAILED IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE ACI 301 MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES. PLANT PRECAST STRUCTURAL FLOOR PLANKS: PLANKS SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER WHO IS REGISTERED IN THE STATE OF INDIANA AND ENGINEERED SEALED SHOP DRAWINGS SHALL BE SUBMITTED. THE DESIGN SHALL CONFORM TO THE BUILDING CODE REQUIREMENTS OF THE AMERICAN CONCRETE INSTITUTE. PLANKS SHALL BE DESIGNED FOR A UNIFORM FLOOR LIVE LOAD EQUAL TO 100 psf. AND A CONCENTRATED LOAD EQUAL TO 2,000 lbs OVER 6.25 SQUARE FEET. IN ADDITION, PLANKS SHALL BE DESIGNED FOR ALL SUPERIMPOSED OR SUSPENDED WEIGHTS IMPOSED BY OTHER TRADES. CONTRACTOR SHALL COORDINATE ALL LOADING INFORMATION. WHERE DETAILED ON THESE DRAWINGS, WELD PLATES SHALL BE INCLUDED. CONTRACTOR SHALL COORDINATE ALL TRADES SO THAT ALL OPENING SIZES AND LOCATIONS ARE KNOWN IN ADVANCE. HOLES REQUIRING THE CUTTING OF PRESTRESS STRANDS SHALL BE PLANNED FOR IN ADVANCE OF INSTALLATION. NO PRESTRESS STRANDS SHALL BE CUT WITHOUT APPROVAL OF PLANK DESIGNER. FOLLOW THE PLANK DESIGNER’S INSTRUCTIONS WHEN CUTTING HOLES. MASONRY: ALL MASONRY SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES, ACI 530-95/ASCE 5- 02/TMS 402-02, AND THE SPECIFICATION FOR MASONRY STRUCTURES, ACI 530.1-02/ASCE 6-02/TMS 602-02. ALL REINFORCED MASONRY SHALL HAVE A MINIMUM F’m = 1500 psi. ALL CONCRETE MASONRY UNITS SHALL BE NORMAL WEIGHT, CONFORMING TO ASTM C55 OR C90 WITH A MINIMUM NET AREA COMPRESSIVE STRENGTH = 2,150 psi. ALL CLAY MASONRY UNITS THAT HAVE A GROUTED REINFORCED CORE DIRECTLY ADJACENT TO THE CLAY UNITS SHALL CONFORM TO STM C 62, ASTM C 216, OR ASTM C 652 WITH A MINIMUM NET AREA COMPRESSIVE STRENGTH = 4,150 psi. ALL REINFORCING STEEL SHALL BE ASTM A615, GRADE 60. ALL MORTAR WHICH IS BELOW GRADE SHALL BE TYPE S AND SHALL BE MADE WITH MASONRY CEMENT. ALL MORTAR WHICH IS ABOVE GRADE SHALL BE TYPE N AND SHALL BE MADE WITH MASONRY CEMENT. ALL GROUT SHALL CONFORM TO ASTM C 476 WITH A MINIMUM COMPRESSIVE STRENGTH OF 2,000 psi. MASONRY SHEAR WALLS SHALL NOT BE INTERRUPTED BY CONTROL JOINTS. CENTER REINFORCING IN CELL OF CMU. REINFORCING SHALL CONTINUE FULL HEIGHT WITH A MINIMUM LAP LENGTH = 2'-6". GROUT REINFORCED CELLS SOLID. GROUT 2 COURSES SOLID UNDER ALL BEAM AND LINTEL BEARINGS, EXTENDING THE LENGTH OF GROUTED SECTION A MINIMUM OF 16" BEYOND THE END BEARING. REINFORCE 8" BOND BEAM W/ (1) #5 TOP & BOT. REINFORCE 12" BOND BEAM W/ (2) #5 TOP & BOT. USE GALVANIZED LADDER-TYPE HORIZONTAL JOINT REINFORCEMENT AT 16" ON CENTER IN MASONRY WALLS WITH 2-3/16" DIAMETER LONGITUDINAL GALVANIZED WIRES IN THE CMU BACKUP WITH 3/16" CROSS WIRES AT 16" ON CENTER. USE 3/16" DIAMETER HOOK AND EYE TYPE ADJUSTABLE GALVANIZED TIES INTO THE VENEER AT 16" ON CENTER EACH WAY. ADJUSTABLE TIES SHALL ATTACH TO THE LADDER REINFORCEMENT AT THE CROSS TIES. GROUT TYPE AND MAXIMUM POUR HEIGHT SHALL CONFORM TO TABLE 1.15.1 OF ACI 530-02/ ASCE 5-02/ TMS 402-02. TYPICAL DETAILS: DETAILS LABELED "TYPICAL DETAILS" ON THE DRAWINGS SHALL APPLY TO ALL SITUATIONS OCCURRING ON THE PROJECT THAT ARE THE SAME OR SIMILAR TO THOSE SPECIFICALLY DETAILED. SUCH DETAILS SHALL APPLY WHETHER OR NOT THEY ARE KEYED AT EACH LOCATION. CONTRACTOR SHALL DETAIL ALL SHOP DRAWINGS WITH APPLICABLE TYPICAL DETAILS SHOWN AT EACH INDIVIDUAL LOCATION. SHORING EXISTING STRUCTURES: CONTRACTOR IS COMPLETELY RESPONSIBLE FOR PROPERLY SHORING, SUPPORTING, BRACING AND PROTECTING THE EXISTING BUILDING STRUCTURE DURING ALL CONSTRUCTION. SHORING NEW EXCAVATIONS AND EXISTING STRUCTURES: THE CONTRACTOR IS RESPONSIBLE FOR THE STABILITY AND SAFETY OF ALL EXCAVATIONS AND SHOULD EXERCISE ALL NECESSARY CAUTIONS TO SHORE, SLOPE OR OTHERWISE MAINTAIN STABLE EXCAVATIONS TO PROTECT WORKERS. ALL EXCAVATIONS SHOULD BE MADE AND MAINTAINED IN ACCORDANCE WITH ALL FEDERAL, STATE AND LOCAL REGULATIONS. IF THE EXCAVATION RESULTS IN SIDE SLOPES STEEPER THAN 2H:1V, SHORING IS REQUIRED TO PERMANENTLY PROTECT THE STABILITY OF THE EXISTING BUILDING FOUNDATIONS AND TO PREVENT UNDERMINING OF THE EXISTING FLOOR SLAB AND ANY POSSIBLE EXISTING UTILITIES. THE DESIGN AND CONSTRUCTION OF THE EXCAVATION SUPPORT AND PROTECTION SHALL BE PROVIDED BY THE CONTRACTOR AND ENGINEERED SEALED SHOP DRAWINGS SHALL BE PROVIDED. CONSTRUCTION: CONTRACTOR SHALL BRACE THE STRUCTURE AS REQUIRED TO MAINTAIN STABILITY UNTIL COMPLETE AND FUNCTIONING AS THE DESIGNED UNIT. UNLESS OTHERWISE NOTED, ALL FOUNDATION WALLS ARE DESIGNED AS CANTILEVERED RETAINING WALLS AND DO NOT NEED TO BE BRACED BEFORE BACKFILLING. EXISTING CONDITIONS: FIELD VERIFY ALL EXISTING CONDITIONS, DIMENSIONS AND ELEVATIONS BEFORE FABRICATING ANY MATERIALS. NOTIFY ARCHITECT IMMEDIATELY OF ANY EXISTING CONDITIONS THAT DIFFER FROM THE CONSTRUCTION DOCUMENTS BEFORE PROCEEDING. SAFETY: IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR WILL BE SOLELY RESPONSIBLE FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND SHALL NOT BE LIMITED TO NORMAL WORKING HOURS. IF ENGINEER PROVIDES CONSTRUCTION REVIEW SERVICES, SUCH SERVICES SHALL NOT INCLUDE REVIEW OF THE CONTRACTOR'S SAFETY MEASURES IN, ON, OR NEAR THE CONSTRUCTION SITE. S5 C T/PED 832' - 1 5/8" 6" 6" 1' - 0" 1' - 0" 1' - 0" 1' - 0" COL. COL. SEE FOUND PLAN FOR T/WALL EL. SEE DWG'S BY GEM BUILDINGS FOR ANCHOR BOLT SIZE & SPACING 8-#7 VERT. W/ 8-#7 DOWELS INTO FTG. PROJECT DOWELS 4'-6" ABOVE T/FTG. # 3 TIES AT 1'-2" c/c. 6" 6" C T/PED 832' - 1 5/8" 1' - 0" 6" 1' - 0" 1' - 0" 6" 6" CENTER OF STEEL COL. SEE FOUND PLAN FOR T/WALL EL. SEE DWG'S BY GEM BUILDINGS FOR ANCHOR BOLT SIZE & SPACING 6-#6 VERT. W/ 6-#6 DOWELS INTO FOOTING PROJECT DOWELS 4'-6" ABOVE T/FTG. #3 TIES @ 1'-2"c/c COL. COL. O P10 85.04° 1' - 3" 1' - 3" 1'-0" 1' - 6 3/8" 1' - 0" T/PED 816' - 11 5/8" COL. COL. SEE FOUND PLAN FOR T/WALL EL. SEE DWG'S BY GEM BUILDINGS FOR ANCHOR BOLT SIZE & SPACING 8-#7 VERT. W/ 8-#7 DOWELS INTO FTG. PROJECT DOWELS 4'-6" ABOVE T/FTG. # 3 TIES AT 1'-2" c/c. 1' - 0" O P9 T/PED 816' - 11 5/8" 1' - 0" 1' - 0" 91.04° 1' - 0" 1' - 0" 1' - 1 3/8" SEE FOUND PLAN FOR T/WALL EL. SEE DWG'S BY GEM BUILDINGS FOR ANCHOR BOLT SIZE & SPACING 8-#7 VERT. W/ 8-#7 DOWELS INTO FTG. PROJECT DOWELS 4'-6" ABOVE T/FTG. # 3 TIES AT 1'-2" c/c. COL. COL. 1' - 0" @ COL. O L3 97.14° 1' - 0" 1' - 0" 1' - 0" T/PED 816' - 11 5/8" 1' - 0" 11 7/8" COL. COL. SEE FOUND PLAN FOR T/WALL EL. SEE DWG'S BY GEM BUILDINGS FOR ANCHOR BOLT SIZE & SPACING 10-#7 VERT. W/ 10-#7 DOWELS INTO FOOTING PROJECT DOWELS 4'-6" ABOVE T/FOOTING #3 TIES @ 1'-2" O P8 80.46° 81.50° 1' - 3" 1' - 3" 1' - 0" 2' - 8 3/8" 1' - 0" 1' - 0" T/PED 816' - 11 5/8" COL. COL. SEE FOUND PLAN FOR T/WALL EL. SEE DWG'S BY GEM BUILDINGS FOR ANCHOR BOLT SIZE & SPACING 12-#7 VERT. W/ 12-#7 DOWELS INTO FOOTING PROJECT DOWELS 4'-6" ABOVE T/FOOTING #3 TIES @ 1'-2" M2 L4 L T/PED 807' - 11 5/8" 1' - 0" 1' - 0" 1' - 0" 6" 1' - 0" 1' - 0" 1' - 0" 92.69° 87.31° COL. COL. SEE FOUND PLAN FOR T/WALL EL. SEE DWG'S BY GEM BUILDINGS FOR ANCHOR BOLT SIZE & SPACING 8-#7 VERT. W/ 8-#7 DOWELS INTO FTG. PROJECT DOWELS 4'-6" ABOVE T/FTG. # 3 TIES AT 1'-2" c/c. L3 L 1' - 0" 1' - 0" 1' - 0" 79.10° 82.75° 1' - 2 5/8" 1' - 0" 1' - 0" 2' - 3 5/8" T/PED 807' - 11 5/8" COL. COL. SEE FOUND PLAN FOR T/WALL EL. SEE DWG'S BY GEM BUILDINGS FOR ANCHOR BOLT SIZE & SPACING 10-#7 VERT. W/ 10-#7 DOWELS INTO FOOTING PROJECT DOWELS 4'-6" ABOVE T/FOOTING #3 TIES @ 1'-2" H4 P6 L 1' - 0" 1' - 0" 1' - 4 3/8" 1' - 0" 9" 9" T/PED 816' - 11 5/8" T/ GRADE BM 816' - 11 5/8" COL. COL. CENTER OF STEEL COL. 8-#7 DOWELS INTO FOOTING W/ #3 TIES @ 1'-2" SEE DWG'S BY GEM BUILDINGS FOR ANCHOR BOLT SIZE & SPACING H5 4.3 AD 9" 9" 1' - 0" 1' - 0" T/PED 816' - 11 5/8" COL. COL. EXIST. CONCRETE FOUND. WALL. REMOVE EXIST. BRICK AS REQUIRED TO PLACE NEW PEDESTAL 6-#7 DOWELS DRILL & EPOXY 14" INTO EXIST. CONCRETE FOOTING. USE #3 TIES @ 1'-2"c/c SEE DWG'S BY GEM BUILDINGS FOR ANCHOR BOLT SIZE & SPACING H5 N AD N4 1' - 6" 11" 1' - 0" 10" T/PED 816' - 11 5/8" COL. COL. EXIST. MASONRY FOUND WALL NOTE: VERIFY DIMENSION IN THE FIELD SEE FOUND PLAN FOR T/LEDGE & T/WALL EL. SEE DWG'S BY GEM BUILDINGS FOR ANCHOR BOLT SIZE & SPACING 8-#7 VERT. W/ 8-#7 DOWELS INTO FTG. PROJECT DOWELS 4'-6" ABOVE T/FTG. # 3 TIES @ 1'-2" c/c. 4" LEDGE 1' - 2" 1' - 8" T/ GRADE BM 816' - 11 5/8" SEE FOUND PLAN FOR GRADE BM. DIMENSIONS SEE DWG'S BY GEM BUILDINGS FOR ANCHOR BOLT SIZE & SPACING 3" MIN. COVER NOTES: ALL MATERIAL IS TO BE ASTM F1554 WITH MIN. Fy=36ksi A LEVELING NUT, TOP NUT AND WASHER MAY BE REDUCED TO MAINTAIN 3" MIN. COVER TYPICAL ANCHOR BOLT DETAIL TOP OF CONCRETE WASHER BOTTOM OF CONCRETE SEE DWG'S BY GEM BUILDINGS FOR ANCHOR BOLT PROJECTION 13" @ 3/4"Ø A.B. 16" @ 1"Ø & LARGER A.B. * SEE DWG'S BY GEM BUILDINGS FOR QUANTITY, SIZE & SPACING OF ANCHOR BOLTS * * 1' - 3" 1' - 3" 1'-3" 1'-3" T/PED 816' - 11 5/8" COL. 8-#7 VERT. W/ 8 #7 DOWELS INTO FTG. PROJECT DOWELS 4'-6" ABOVE FTG. #3 TIES @ 1'-2"c/c SEE DWG'S BY GEM BUILDINGS FOR ANCHOR BOLT SIZE & SPACING COL. Date: Scale Drawn By Checked By Project Number ARCHITECTURE PLANNING INTERIOR DESIGN STRUCTURAL ENGINEERING 424 East Fourth Street Cincinnati, Ohio 45202 w w w . c h a r c h i t e c t s . c o m tel: 513/241/4474 fax: 513/241/0081 ISSUANCES COMPUTER FILE 1400 West Dorothy Lane Dayton, Ohio 45409-1310 Tel: (937) 224-0861 Fax: (937) 224-5777 3417 South Sherman Drive Beech Grove, IN 46107 Tel: (317) 780-1555 Fax: (317) 780-6525 750 North Orleans, Suite 400 Chicago, IL 60610 Tel: (312) 944-8230 Fax: (312) 944-8297 117 East Washington Street, Suite 200 Indianapolis, IN 46204 Tel: (317) 637-2222 Fax: (317) 637-2260 1137 West Taylor St. Suite 316 Chicago, IL 60607 Tel: (312) 224-8460 Fax: (312) 224-8961 1025 N.Watery Ln. Brigham City, UT 84302 TEL: (453) 723-5000 FAX: (453) 538-5506 6622 Kingspointe Parkway Orlando, FL 33819 Tel: (407) 816-9400 Fax: (407) 816-9300 No. Description Date As indicated 6/12/2008 10:29:19 AM C:\Documents and Settings\mb\My Documents\nvclc\NVCLC_foundation_mb.rvt F301 TYPICAL CONCRETE DETAILS, PLAN DETAILS AND GENERAL NOTES NEW WORSHIP CENTER MB KI 06-04-2008 535-3581 F301 3/8" = 1'-0" 3 TYPICAL CORNER F301 3/8" = 1'-0" 1 TYPICAL THICKENED FOOTING F301 3/8" = 1'-0" 2 TYPICAL STEP FOOTING F301 3/8" = 1'-0" 4 TYPICAL INTERSECTION F301 1/8" = 1'-0" 5 TYPICAL OPENING F301 3/8" = 1'-0" 6 TYPICAL UTILITY TRENCH F301 3/8" = 1'-0" 7 TYP COLUMN FOOTING F301 3/8" = 1'-0" 8 TYP. COLUMN FOOTING F301 3/8" = 1'-0" 9 TYP BOX-OUT F301 1/2" = 1'-0" 10 TYP THICKENED SLAB F301 3/8" = 1'-0" 12 TYP. HOLD DOWN F301 3/4" = 1'-0" 11 TYP JOINT DETAILS 1 PERMIT SET 04.25.08 1 ADDENDUM NO. 2 05.16.08 2 ADDENDUM NO. 3 05.23.08 F301 1/2" = 1'-0" O1 PLAN DETAIL O1 F301 1/2" = 1'-0" P1 PLAN DETAIL P1 F301 1/2" = 1'-0" Q1 PLAN DETAIL Q1 F301 1/2" = 1'-0" R1 PLAN DETAIL R1 F301 1/2" = 1'-0" S1 PLAN DETAIL S1 F301 1/2" = 1'-0" T1 PLAN DETAIL T1 F301 1/2" = 1'-0" U1 PLAN DETAIL U1 F301 1/2" = 1'-0" V1 PLAN DETAIL V1 F301 1/2" = 1'-0" W1 PLAN DETAIL W1 F301 1/2" = 1'-0" X1 PLAN DETAIL X1 F301 1/2" = 1'-0" Y1 PLAN DETAIL Y1 F301 1/2" = 1'-0" Z1 PLAN DETAIL Z1 3 ADDENDUM NO. 4 05.30.08 F301 3/4" = 1'-0" 13 TYPICAL ANCHOR BOLT DETAIL 4 ADDENDUM NO. 5 06.04.08 F301 1/2" = 1'-0" A2 PLAN DETAIL A2 PERMIT SET 06.10.08