H003 - DETAILS
AIR FLOW AIR FLOW 8"D (150 FPM) 6" COMPACTED 14"D RUNOUT DUCT 42"D S.A. MAIN (VARIES) 6" CONCRETE SLAB 8"D FLOOR UNDERSEAT DIFFUSER WITH INTEGRAL DAMPER SLEEVE 6" MIN. SCALE: NONE TEST PLUG PRESSURE-TEMPERATURE SHUT-OFF VALVE COMBINATION BALANCING - UNION SHUT-OFF VALVE MANUAL AIR VENT CONTROL VALVE. AUTOMATIC TWO-PORT COIL HEATER UNIT PROPELLER SCALE: NONE SHUT-OFF VALVE. COMBINATION BALANCING - UNION MANUAL AIR VENT SHUT-OFF VALVE PRESSURE-TEMPERATURE TEST PLUG. SCALE: NONE SUPPLY FAN T.S.P. (INCH W.G.) + 2". CENTERLINE DIMENSION NOT LESS THAN 4" MINIMUM - CENTERLINE TO CENTERLINE. TEE WITH CLEANOUT PLUG. PAN CONNECTION. DRAIN PIPE SAME SIZE AS UNIT DRAIN ROOFTOP UNIT SPLASH BLOCK. ROOF TRAP UNIT ROOF CURB. VERIFY REQUIRED HEIGHT FOR DRAIN PIPE AND TRAP INSTALLATION. PROVIDE CURB OF ADEQUATE HEIGHT TO ATTAIN REQUIRED DIMENSION. SCALE: NONE TEST PLUG PRESSURE-TEMPERATURE SHUT-OFF VALVE COMBINATION BALANCING - UNION SHUT-OFF VALVE MANUAL AIR VENT CONTROL VALVE. AUTOMATIC THREE-PORT COIL VERIFY VALVE PORTING & CONNECT PIPING TO PROPER PORTS, PER MFR. RECOMMENDATIONS NOTE: E H003 A H003 B H003 D H003 REFER TO AIR HANDLING UNIT SCHEDULE FOR AUTO. CONTROL VALVE SIZE AND SEE DRAWINGS FOR SIZE OF COIL PIPING. NORMALLY OPEN THRU COIL. COIL RECIRCULATING PUMP (CP-). BALANCING - SHUTOFF VALVE. AUTOMATIC TWO-PORT CONTROL VALVE. PRESSURE-TEMPERATURE TEST PLUG. CHECK VALVE IN FULL SIZE BY-PASS. SCALE : NONE NOTE: 1/2" DRAIN VALVE. AIR VENT. SHUTOFF VALVE. UNION. SHUT-OFF VALVE PLUG. VALVE. MANUAL AIR VENT UNION COIL AUTOMATIC TWO-PORT CONTROL COMBINATION BALANCING - PRESSURE-TEMPERATURE TEST SHUT-OFF VALVE. SCALE: NONE C H003 F H003 H.W. RETURN H.W. SUPPLY ROOF SCALE: 1" =1'-0" G H003 5 2 1 3 4 6 5 1 4 6 3 2 4 2 3 1 5 2 3 2 5 4 1 2 5 4 3 1 6 6 1 2 3 3 5 5 2 1 3 4 6 6 2 4 3 5 1 7 9 8 5 6 4 1 2 3 6 6 4 1 3 2 3 2 1 4 5 5 5 2 3 2 8 9 7 6 7 1 7 6 4 VALVE. 6 AUTOMATIC TWO-PORT CONTROL 6 SCALE : NONE REFER TO AIR HANDLING UNIT SCHEDULE FOR AUTO. CONTROL VALVE SIZE AND SEE DRAWINGS FOR SIZE OF COIL PIPING. NORMALLY OPEN THRU COIL. COIL RECIRCULATING PUMP (CP-). BALANCING - SHUTOFF VALVE. AUTOMATIC THREE-PORT CONTROL VALVE. PRESSURE-TEMPERATURE TEST PLUG. CHECK VALVE IN FULL SIZE BY-PASS. NOTE: 1/2" DRAIN VALVE. AIR VENT. SHUTOFF VALVE. UNION. H.W. RETURN H.W. SUPPLY ROOF 7 9 8 5 6 4 1 2 3 5 2 3 2 8 9 7 6 7 1 7 6 4 H H003 ROOFTOP UNIT DRAIN PIPING PROPELLER UNIT HEATER AIR TERMINAL UNIT REHEAT COIL AIR TERMINAL UNIT REHEAT COIL ROOFTOP UNIT H.W. HEATING COIL CABINET UNIT HEATER PIPING UNDERFLOOR DUCT DETAIL ROOFTOP UNIT H.W. HEATING COIL DRAW-THRU UNIT 2 WAY CONTROL 3 WAY CONTROL RTU-1, 3, 4 RTU-2 12"D 24"D D1 - 8" 75 CFM D4 - 100 CFM 6" D4 - 100 CFM 6" D4 - 100 CFM 6" 12"D 24"D D1 - 8" 75 CFM D4 - 100 CFM 6" D4 - 100 CFM 6" D4 - 100 CFM 6" 96/24 84/28 13' - 4 1/2" 10' - 10" 8/8 RTU-3 9' - 1" AC-3 48/20 50/21 14"D 12' - 0" 13' - 11" 13' - 11" RTU-4 10/6 8"D 10' - 0" 8' - 10 1/2" Date: Scale Drawn By Checked By Project Number ARCHITECTURE PLANNING INTERIOR DESIGN STRUCTURAL ENGINEERING 424 East Fourth Street Cincinnati, w w w . c h a r c h Ohio i t e c t s . 45202 c o m tel: 513/241/4474 fax: 513/241/0081 ISSUANCES COMPUTER FILE 1400 West Dorothy Lane Dayton, Ohio 45409-1310 Tel: (937) 224-0861 Fax: (937) 224-5777 3417 South Sherman Drive Beech Grove, IN 46107 Tel: (317) 780-1555 Fax: (317) 780-6525 750 North Orleans, Suite 400 Chicago, IL 60610 Tel: (312) 944-8230 Fax: (312) 944-8297 117 East Washington Street, Suite 200 Indianapolis, IN 46204 Tel: (317) 637-2222 Fax: (317) 637-2260 1137 West Taylor St. Suite 316 Chicago, IL 60607 Tel: (312) 224-8460 Fax: (312) 224-8961 1025 N.Watery Ln. Brigham City, UT 84302 TEL: (453) 723-5000 FAX: (453) 538-5506 6622 Kingspointe Parkway Orlando, FL 33819 Tel: (407) 816-9400 Fax: (407) 816-9300 1 SCHEMATIC DESIGN 10.18.07 2 DESIGN DEVELOPMENT 01.18.08 3 CD 50% 03.14.08 4 PERMIT SET 04.25.08 5 ADDENDUM #2 05.16.08 No. Description Date 6 ADDENDUM #3 05.22.08 7 ADDENDUM #5 06.04.08 8 PERMIT SET 06.10.08 1/4" = 1'-0" 6/10/2008 1:53:45 PM C:\Drawings\REVIT\Northview\2007-06019-Central-local.rvt H003 DETAILS New Worship Center ARC CSR/GSS 05-22-08 2007-06019 1/4" = 1'-0" 1 SECTION 1/4" = 1'-0" 2 SECTION 1/4" = 1'-0" 3 SECTION 1/4" = 1'-0" 4 SECTION 1/4" = 1'-0" 5 SECTION