Loading...
HomeMy WebLinkAboutH231 - SECOND BALCONY LEVEL FLOOR PLAN - HVACDN UP DN DN DN DN A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A AA AB 1 3 5 H3 2.3 4 X9 X2 X3 X6 X7 X8 H2 4.6 P 4.3 4.8 M L C L4 Q S T ND U H1.5 1.5 H3.2 X 2.0 3.8 H1 2.6 3.6 0.8 G Y2 Z L2 L3 P12 P15 X10 X4 X5 X1 0.4 2.4 2.8 3.3 4.4 Y E F B Z1 P4 P5 P3 P2 P6 P7 P10 N1 N2 N3 M1 M2 M3 N 1.3 2.1 W W3 W2 W1 P8 P9 2.2 4.2 4.1 P1 T4 T1 T2 T3 T5 S1 S2 S3 S4 S5 A1 A2 J J1 J2 3.1 G1 - 48 x 48 4200 CFM (5) D2 - 24 x 3 200 CFM ELEV. D5 - 9" 300 CFM D5 - 9" 300 CFM 24"D 24"D 24"D 12"D 8"D D4 - 100 CFM 6" (58) D1 - 8" 75 CFM (21) 12"D 12"D 12"D 12"D 12"D 12"D 12"D 12"D 12"D 12"D 12"D 54/36 4 4 1 1 3 2 2 2 2 2 S-33 2 H003 G1 - 48 x 48 4200 CFM (5) S-33 301 S-33 300 S-33 S-34 5 5 5 TYP. T RTU-1 2 C-D A-D A-D A-D A-D A-D X Z P O N M S W J18 Y2 Y L Date: Scale Drawn By Checked By Project Number ARCHITECTURE PLANNING INTERIOR DESIGN STRUCTURAL ENGINEERING 424 East Fourth Street Cincinnati, w w w . c h a r c h Ohio i t e c t s . 45202 c o m tel: 513/241/4474 fax: 513/241/0081 ISSUANCES COMPUTER FILE 1400 West Dorothy Lane Dayton, Ohio 45409-1310 Tel: (937) 224-0861 Fax: (937) 224-5777 3417 South Sherman Drive Beech Grove, IN 46107 Tel: (317) 780-1555 Fax: (317) 780-6525 750 North Orleans, Suite 400 Chicago, IL 60610 Tel: (312) 944-8230 Fax: (312) 944-8297 117 East Washington Street, Suite 200 Indianapolis, IN 46204 Tel: (317) 637-2222 Fax: (317) 637-2260 1137 West Taylor St. Suite 316 Chicago, IL 60607 Tel: (312) 224-8460 Fax: (312) 224-8961 1025 N.Watery Ln. Brigham City, UT 84302 TEL: (453) 723-5000 FAX: (453) 538-5506 6622 Kingspointe Parkway Orlando, FL 33819 Tel: (407) 816-9400 Fax: (407) 816-9300 1 SCHEMATIC DESIGN 10.18.07 2 DESIGN DEVELOPMENT 01.18.08 3 CD 50% 03.14.08 4 PERMIT SET 04.25.08 5 ADDENDUM #2 05.16.08 No. Description Date 6 ADDENDUM #3 05.22.08 7 ADDENDUM #5 06.04.08 8 PERMIT SET 06.10.08 1/8" = 1'-0" 6/10/2008 1:57:26 PM C:\Drawings\REVIT\Northview\2007-06019-Central-local.rvt H231 SECOND BALCONY LEVEL FLOOR PLAN - HVAC New Worship Center ARC CSR/GSS 05-22-08 2007-06019 1/8" = 1'-0" 1 SECOND BALCONY LEVEL FLOOR PLAN - HVAC 1 LOCATE RETURN AIR GRILLES AT APPROX. 54'-0" A.F.F OF WORSHIP CENTER . COORDINATE EXACT LOCATION WITH ARCHITECT. 2 RETURN AIR DUCT OPEN TO CHASE. 3 SUPPLY AIR DUCT RISER IN CHASE SERVED BY RTU-1. 4 SUPPLY MAIN TO RUN ABOVE BALCONY 1 CEILING TO SERVE BALCONY 2. 5 LOCATE ANGULAR JOINTS IN THE CENTER SPACE BETWEEN THE BALCONY STRUCTURAL BEAMS. COORDINATE WITH ARCHITECT PRIOR TO LAYOUT OF DUCT. NOTES 300 BALCONY-2 301 ELEVATOR VESTIBULE S-33 STAIR-3 S-34 STAIR-4 ROOM INDEX