HomeMy WebLinkAboutP001 - LEGEND SCHEDULES AND DETAILSSCALE: SCALE: SCALE:
SCALE:
S
SCALE:
B
P2
NONE NONE NONE
NONE
NONE
SHEET DESCRIPTION
PIT LEVEL ZONE FIRST LEVEL ZONE FIRST BALCONY ZONE SECOND BALCONY ZONE CATWALK
SERVED FROM
SECOND BALCONY ZONE
DN
FIXTURES
DRAINS
FIRE SUPPRESSION DESIGN NOTES LEGEND
FIRE CONTROL EQUIPMENT
TYPICAL GAS CONNECTION
PUMPER CONNECTION AT EQUIPMENT TRAP PRIMER
FREE STANDING
SPRINKLER FLOOR CONTROL VALVE GAS RISER
SPRINKLER ZONES
S
MISC. CARRIER
MFR.
CAT. Nos.
D
D SEE SPECS
CAT. Nos.
MFR.
95-SS
95-SS
C
C
SEE FIXTURE
SCHED. NOTES
P.
SUPPLY TRIM SUPPLY/STOP WASTE TRIM
N.
MFR.
A
A
MFR.
UNIT
UNIT
A
A
CAT. Nos.
MFR.
B
B
MFR.
B
B
CAT. Nos.
UNIT
UNIT
CAT. Nos.
INTEGRAL
INTEGRAL
TRAP/FIX. DR.
CAT. Nos.
K.
J.
FIXTURE
L.
M.
WASTE & VENT
CAT. Nos.
2257.103
2257.103
A
A
MFR.
TRAP
4" 4" 2"
TEPID
4" INT.
AIR BREAK
AIR GAP
WASTE-MIN.
VENT-MIN.
INDIRECT
FIX. DRAIN
C.W. HARD
FIX OUTLET
F.
E.
G.
H.
SLOAN "ROYAL" (ZURN, TOTO)
SMITH (ZURN, WATTS, JOSAM)
OLSONITE (BENEKE, CHURCH, BEMIS, TOTO)
AMERICAN STANDARD (KOHLER, ELJER, TOTO)
H.W. 120°F
1"
RIM
17" TO
RIM
15" TO
DESCRIPTION
C.W.
MOUNTING
HEIGHT
CHICAGO (ZURN, T&S BRASS)
WILLIAMS (FIAT, MUSTEE, CREATIVE IND)
SUPPLY
McGUIRE (EBC, ZURN)
HALSEY TAYLOR (ELKAY, OASIS, SUNROC)
ELKAY (JUST WITH LUG AND SCREW)
D
D
H V-70, T-35
G 8902DF
A
G 155A
A UNIT
A
ROUGH
A UNIT
H UNIT
B B
B
E
B
E
UNIT
UNIT
UNIT
E G H2165LK J LK-35 G 8912DF
INTEGRAL
INTEGRAL
K UNIT G G (2) 8902 D
A 6561.017
6561.017
H MTB-2424
A
1.5" 1.5"
2" 2" 1.5"
1.25"
2"
1.5"
INT
2" 2" 1.5"
3" 3" 1.5"
2"
3"
INT
3"
1.5"
1.5" 1.5" 1.5" 1.5" 1.5" J LR-2219
0.5"
24"
TO LIP
17"
TO LIP
FAUCET
0.5"
36" TO
0.5"
0.5"
0.5"
0.5"
K HAC8FSBL-Q-ADA
33" LOW
BUBBLER
0.5"
B.
A.
C.
D.
MARK
A1
A2
B1
C1
C2
D1
F1
G1
URINAL/WALL HUNG/1.0GPF
MOP BASIN/FLOOR SET/24"x24"x10"
FIXTURE SCHEDULE NOTES:
5 COLOR SELECTION BY ARCHITECT.
3 PROVIDE TRUEBRO "LAV GUARD" PIPE COVERING ON EXPOSED SUPPLY AND WASTE PIPING LOCATED BELOW FIXTURE.
1 FIXTURE AND INSTALLATION SHALL CONFORM TO ALL ADA REQUIREMENTS FOR THE HANDICAPPED.
4 PROVIDE CHECK VALVES IN HOT AND COLD WATER SUPPLY PIPING.
COUNTERTOP SINK/S.S./SINGLE/22"X19"X7"
ELECTRIC WATER COOLER/WALL HUNG/ADA/BI-LEVEL
URINAL/WALL HUNG/ADA/1.0GPF
CATALOG NUMBERS INDICATED ARE THOSE OF THE FIRST NAMED MANUFACTURER IN EACH CATEGORY LISTED BELOW - ADDITIONAL MANUFACTURERS ARE LISTED IN PARENTHESIS
H.W. 140°F
1
G H2165LK
186-1.0-SMO
186-1.0-SMO
H2165K K UNIT
O.
786-GN2A-E3-369
897-RCF
C'TOP LAVATORY/ADA/0.5GPM
AMERICAN STANDARD (ZURN, CHICAGO, T&S)
A F
6 COORDINATE MOUNTING OF ACCESSORIES WITH ARCHITECT.
111-SMO
111-SMO
0496.300 1480.115
SEE DRAIN
SCHEDULE NOTES
U'DECK CLAMP
BEARING PAN
2" STANDPIPE
TRAP PRIMER CON.
PLASTIC
ACID RESIS.
CAST IRON
DBL. DRAINAGE
FLSHG. CLAMP
SED. BUCKET
ANCHOR FLANGE
STAINLESS STEEL
STRAINER/GRATE
HINGED
STRAINER
LESS TOP
FUNNEL
DOME
RECESSED
FLAT
ADJUSTABLE
STAINLESS STEEL
NICKEL-BRONZE
BODY OUTLET TOP FINISH
3"
SIZE
SIDE
BOTTOM
PLASTIC
GALVANIZED
ACID RESIS.
SIZE
STAINLESS STEEL
TYPE
J.R. SMITH
(OR EQUAL BY
MANUFACTURER
ROOF
PLANTER
FLOOR
CATALOG NOS.
CAST IRON
4"
AUX. STRAINER
ADDITIONAL FEATURES
MARK
DRAIN SCHEDULE NOTES:
FD2
RD2
FD1
1015 4" 15"DIA
2110
2005A
3
PLAZA
6"RD
8"DIA
1,2
1,2
CAST IRON
GALVANIZED
CAST IRON
ZURN, JOSAM,
WATTS, MIFAB)
1 DRAINS WITHOUT TRAP PRIMERS SHALL HAVE PRIMER OPENINGS PLUGGED.
2 CONTRACTOR SHALL CLOSELY COORDINATE WITH GENERAL CONTRACTOR INSTALLATION OF DRAINS.
3 COORDINATE DRAIN INSTALLATION CLOSELY WITH ROOFING CONTRACTOR.
ADJUSTABLE
EXTENSION
A FIRE SUPPRESSION CONTRACTOR SHALL DESIGN AND INSTALL A COMPLETE
AUTOMATIC WET PIPE STANDPIPE AND SPRINKLER SYSTEM THROUGHOUT ALL NEW
AREAS OF THE BUILDING. THE FIRE SUPPRESSION CONTRACTOR SHALL ALSO
PROVIDE MODIFICATIONS OF AND ADDITIONS TO AN EXISTING WET PIPE SPRINKLER
SYSTEM IN THE EXISTING BUILDING TO ACCOMMODATE NEW CONSTRUCTION AS
INDICATED ON THE DRAWINGS AND AS OUTLINED IN THE SPECIFICATIONS.
B BASIS FOR DESIGN IS LIGHT HAZARD OCCUPANCY EXCEPT MECHANICAL ROOMS,
BOILER ROOMS, ALL STORAGE ROOMS, AND KITCHEN SERVICE AREAS WHICH ARE
ORDINARY GROUP 1. STAGE, STAGE EXIT STAIRS AND SCENE SHOP ARE ORDINARY
GROUP 2. REFER TO THE FLOOR PLANS FOR ADDITIONAL HAZARD OCCUPANCIES.
C MINIMUM AREA OF OPERATION FOR LIGHT HAZARD SYSTEMS SHALL BE 1500 SQUARE
FEET, .10 GPM/SQ. FT., 225 SQUARE FEET MAXIMUM PER SPRINKLER. FOR ORDINARY
HAZARD, 1500 SQUARE FEET MINIMUM AREA OF OPERATION, .15 GPM/SQ. FT. FOR
GROUP 1, .20 GPM/SQ.FT. FOR GROUP 2, 130 SQUARE FEET MAXIMUM PER
SPRINKLER. A 250 GPM HOSE STREAM ALLOWANCE SHALL BE USED IN THE DESIGN.
D PROVIDE SPRINKLER PROTECTION AT EACH FLOOR LEVEL AND THROUGHOUT ALL
AREAS AS REQUIRED BY CODE.
E ALL PIPING SHOWN SHALL BE INSTALLED AS SIZED. FOR PIPING NOT SHOWN OR
SIZED ON THE DRAWINGS, PIPE SIZING SHALL BE BASED ON FIRE SUPPRESSION
CONTRACTORS HYDRAULIC CALCULATIONS. MINIMUM SPRINKLER OUTLETS ON
PIPING SHALL BE 1".
F SPRINKLERS IN AREAS WITH CEILINGS SHALL BE CONCEALED TYPE WITH WHITE
FINISH COVER PLATE. UPRIGHT SPRINKLERS TO BE INSTALLED IN EXPOSED
STRUCTURAL AREAS. ALL SPRINKLERS TO BE QUICK RESPONSE TYPE.
G REFER TO ARCHITECTURAL DRAWINGS FOR CONSTRUCTION AND CEILING TYPES.
COORDINATE SPRINKLER LOCATIONS WITH CEILING DEVICES (LIGHTING, GRILLES,
ETC..). OBTAIN ARCHITECTS APPROVAL OF SPRINKLER LAYOUT PRIOR TO
INSTALLATION. FINAL FINISHED APPEARANCE OF FIRE SUPPRESSION WORK MUST BE
APPROVED BY THE ARCHITECT.
H FIRE SUPPRESSION CONTRACTOR SHALL PERFORM A FLOW TEST AND OBTAIN
APPROVAL FROM GOVERNING AUTHORITIES PRIOR TO STARTING WORK.
I FSC SHALL EXERCISE SPECIAL CARE TO COORDINATE PIPING AND EQUIPMENT
LOCATIONS WITH ALL OTHER TRADES.
J COORDIATE WITH ARCHITECT LOCATIONS OF ALL EXPOSED SPRINKLER PIPING IN
SANCTUARY. PROVIDE SPRINKLER PROTECTION ABOVE AND BELOW "CLOUDS" SEE
ARCHITECTURAL DRAWINGS FOR LOCATIONS
WATER CLOSET/W.H./1.6GPF/BATTERY SENSOR F.V.
0.5" 1.25" 1.5" 1.5" 1.5" 1.5" G 155A G 8902DF
RIM
0.5"
34" TO
B2 WALL HUNG LAVATORY/ADA/0.5GPM A 0355.012 F 1480.115 G H2165LK
0.75"
0.75"
D
WATER CLOSET/W.H./1.6GPF/BATTERY SENSOR F.V./ADA
F2 COUNTERTOP SINK/S.S./DOUBLE/33"X19"X7"/DISPOSER 0.5" 0.5" 1.5" 1.5" 1.5" 1.5" 1.5" J LR-3319 E 2300-8CP G H2165LK J LK-35 G
SEE SPECS
GUY GRAY (OATEY, PLASTIC ODDITIES)
SIZE AND ACCESSORIES
FIRE CONTROL EQUIPMENT SCHEDULE NOTES:
1 CABINET DOOR SWING SHALL BE COORDINATED WITH THE ARCHITECT.
CABINET
STYLE
SEMI-RECESSED
STAINLESS STEEL
FCE1
MARK
STEEL
ALUMINUM
RECESSED
MATERIAL
2.5"-ADJ. REG.
2.5"-DISC. REG
1.5"-INT. REG.
2.5"-INT. REG.
1.5"-DISC. REG.
SURFACE MTD.
TRIMLESS
SOLID PANEL
DUO-PANEL
GLASS PANEL
2.5"
1.5"
DOOR
VALVES EXTINGUISHERS
SIZE AND TYPE
2.5 GAL.-WATER
1.5"-ADJ. REG.
2.5"X1-1.5"RED.
VALVE MTD.
HYDROLATOR
1.5"-100 FT.
10# ABC
PIPE MTD.
WALL MTD.
10# CO2
5# ABC
HOSE RACK
SIZE & MOUNTING
SCHEDULE NOTES
WALL BRACKET
1
SEE FCS
5# CO2
9# HALON
13# HALON
TYPE "K"
PIPE CAP
3" MIN.
SHUT-OFF VALVE
ON PLANS
INDICATED
PIPE SIZE AS
TP
EQUIPMENT
CONNECTION
UNION
EQUIPMENT CONNECTION
PIPE SIZE
FLOOR
TP
F
P001
PIPING TO FLOOR DRAINS
UNLESS NOTED OTHERWISE.
SHALL BE RUN BELOW FLOOR,
0.5"
WHERE APPLICABLE
FLOOR DRAIN
FINISHED CEILING
WALL
TP
SUPPLY SHALL BE
OFF TOP OF MAIN
COLD WATER MAIN
INSTALL PIPING CONCEALED
INSTALL PIPING TIGHT TO WALL
SURFACE IN UNFINISHED AREAS.
IN WALL IN FINISHED AREAS.
TRAP PRIMER, WITH DISTRIBUTION
DRAINS. LOCATE ABOVE CEILING
UNIT WHEN SERVING MULTIPLE
IN FINISHED AREAS.
FCE2 1
RD3 1015 5" 15"DIA 3
RD4 1015 6" 15"DIA 3
RD5 1015 8" 15"DIA 3
RD1 1015 3" 15"DIA 3
A3 WATER CLOSET/F.S./1.6GPF/ADA/FLUSH TANK 0.5" 3" INT. 1.5" A 2386.012 A UNIT G H2166LK A UNIT A INTEGRAL C 95-SS
P001 LEGEND, SCHEDULES AND DETAILS
P003 SITE PLAN
P100 FIRST LEVEL - EXISTING BUILDING - DEMOLITION
P200 FIRST LEVEL - EXISTING BUILDING - NEW WORK
P201 UNDERFLOOR PLAN - NEW WORK
P202 PIT LEVEL - NEW WORK
P203 FIRST LEVEL - NEW WORK
P204 FIRST BALCONY - NEW WORK
P205 SECOND BALCONY - NEW WORK
P206 ROOF PLAN
P300 SOIL, WASTE AND VENT DIAGRAM
C
P001
DUCTILE IRON WITH
RESTRAINED JOINTS
48" DIA.
(VERIFY STYLE WITH AUTHORITY)
NEENAH MODEL #R-1643 OR EQUAL
FRAME AND COVER
4"
GRAVEL
OPEN BOTTOM
BALL DRIP
VALVE
GRADE
POURED CONCRETE
SUPPORT
SLOPE
FREE STANDING SIAMESE
PUMPER CONNECTION
2FT
MIN.
PRE-CAST MANHOLE
INSPECTION TO BALL
FOR ACCESS AND
DRIP.
A
P001
2"
DRAIN ASSEMBLY
SIZE PER HYDRAULIC
ALARM TEST &
SD
F
CALCULATIONS
FLOW SWITCH
P
S
4"
TO SPRINKLER
SYSTEM
FLOOR SLAB
AROUND PIPE (FROM
COPPER WIRE WRAPPED
#12 PLASTIC COATED
SCALE : NONE
B
P001
GRADE
2"
1LB. MAGN. ANODE
FITTING 36" MIN.
TRANSITION
PLASTIC STEEL
30" MIN. 12"
ATTACH TO RISER
ABOVE GRADE
BLDG. WALL
PVC SLEEVE CAULKED
WEATHERTIGHT
DIELECTRIC UNION
VALVE
2"
METER SETTING).
A G A UNIT A INTEGRAL C 95-SS
4021.800
A4 WATER CLOSET/F.S./1.6GPF/ADA/FLUSH TANK/FLUSH LEVER ON RT. 0.5" 3" INT. 3" 3" 1.5" A UNIT H2166LK
D2 SCULLERY SINK/FLOOR SET/S.S. 0.5" 0.5" 1.5" J SS8124 E 445-L8CP G H2165LK J LK-24RT G 8912DF
4'-0"MIN.
SLOPE TO BUILDING
3016.016,
1,2
1,2
1,2,3,8
1,2,3,8
1
4,6
2
2
2,7
1,2,57
2 PROVIDE CHROME PLATED BRASS NIPPLES TO WALL.
D3 UTILITY CONNECTION BOX 0.5" L BIM-875 L UNIT BALL VALVE
BOTTOM
18" TO
SEE SPECS
SEE SPECS
SEE SPECS
SEE SPECS
1.5" 1.5" 1.5" 1.5"
8912DF
ISE (WHIRLAWAY)
M PRO ES
1.25" 1.5" 1.5" 1.5" 1.5"
7 COORDINATE ELECTRIC REQUIREMENTS WITH EC.
8 PROVIDE WITH 0.5 GPM AERATOR,
P002 DETAILS
GC GENERAL CONTRACTOR
PC PLUMBING CONTRACTOR
FSC FIRE SUPPRESSION CONTRACTOR
HC HVAC CONTRACTOR
EC ELECTRICAL CONTRACTOR
SUC SITE UTILITY CONTRACTOR
"CONNECT TO EXISTING" SYMBOL
2 "DETAIL NOTE" SYMBOL (FOR NOTES ON SAME DETAIL)
3 "NOTE" SYMBOL (FOR NOTES ON SAME SHEET)
A1 "UP TO" SYMBOL (ITEM ON FLOOR ABOVE)
WS WATER SERVICE
FS FIRE SERVICE
GS GAS SERVICE
SANITARY DRAINAGE PIPE
ST STORM DRAINAGE PIPE
TP TRAP PRIMER DISCHARGE PIPE
PD PUMP DISCHARGE PIPE
SANITARY VENT PIPE
DCW COLD WATER PIPE
DHW HOT WATER PIPE (120 DEGS. F.)
DHWR HOT WATER RETURN PIPE (120 DEGS. F.)
SHUTOFF VALVE
FLOW CONTROLLER
CHECK VALVE
UNION
DIRECTION OF FLOW
DIRECTION OF PITCH
G NATURAL GAS PIPE
F FIRE SUPPRESSION PIPE
S SPRINKLER PIPE (WET)
SD SPRINKLER DRAIN PIPE
SUPERVISED VALVE
FLOW SWITCH
ROOF DRAIN ABOVE
A2 PLUMBING FIXTURE
FD2 DRAIN (FD, AD, DD, RD, PD, OD)
FCE2 FIRE CONTROL EQUIPMENT
VR VENT RISER
CO CLEANOUT
VTR VENT THRU ROOF
SR SUPPLY RISER
HB HOSE BIBB
WH WALL HYDRANT
DS DOWNSPOUT
AFF ABOVE FINISH FLOOR
AFG ABOVE FINISH GRADE
FR FIRE RISER (STANDPIPE/SPRINKLER)
FDC FIRE DEPARTMENT CONNECTION
FDV FIRE DEPARTMENT VALVE
F.F. FINISH FLOOR ELEVATION
INV INVERT ELEVATION
PRESSURE GAUGE WITH STOP
THERMOMETER
DETAIL B SHOWN ON SHEET P2
FDC FIRE DEPARTMENT CONNECTION PIPE
FPTH FIRE PUMP TEST HEADER PIPING
FS
1" 4" INT. 4" 4" 2"
3" 3"
G
P001
E
P001
P
T
INDEX OF DRAWINGS
Date: Scale
Drawn By
Checked By
Project
Number
ARCHITECTURE
PLANNING
INTERIOR DESIGN
STRUCTURAL ENGINEERING
424 East Fourth
Street
Cincinnati, w w w . c h a r c h Ohio i t e c t s . 45202 c o m
tel: 513/241/4474 fax: 513/241/0081
ISSUANCES
COMPUTER FILE
1400 West Dorothy Lane
Dayton, Ohio 45409-1310
Tel: (937) 224-0861
Fax: (937) 224-5777
3417 South Sherman Drive
Beech Grove, IN 46107
Tel: (317) 780-1555
Fax: (317) 780-6525
750 North Orleans, Suite 400
Chicago, IL 60610
Tel: (312) 944-8230
Fax: (312) 944-8297
117 East Washington
Street, Suite 200
Indianapolis, IN 46204
Tel: (317) 637-2222
Fax: (317) 637-2260
1137 West Taylor St.
Suite 316
Chicago, IL 60607
Tel: (312) 224-8460
Fax: (312) 224-8961
1025 N.Watery Ln.
Brigham City, UT 84302
TEL: (453) 723-5000
FAX: (453) 538-5506
6622 Kingspointe
Parkway
Orlando, FL 33819
Tel: (407) 816-9400
Fax: (407) 816-9300
1 SCHEMATIC DESIGN 10.18.07
2 DESIGN DEVELOPMENT 01.18.08
3 CD 50% 03.14.08
4 PERMIT SET 04.25.08
5 ADDENDUM #2 05.16.08
No. Description Date
6 ADDENDUM #3 05.22.08
7 ADDENDUM #5 06.04.08
8 PERMIT SET 06.10.08
6/10/2008 2:18:49 PM
C:\Drawings\revit\Northivew
Church\2007-06019-Central-LOCAL.rvt
P001
LEGEND SCHEDULES
AND DETAILS
New Worship
Center
TWN
ATM
05-22-08
2007-06019