Loading...
HomeMy WebLinkAboutP001 - LEGEND SCHEDULES AND DETAILSSCALE: SCALE: SCALE: SCALE: S SCALE: B P2 NONE NONE NONE NONE NONE SHEET DESCRIPTION PIT LEVEL ZONE FIRST LEVEL ZONE FIRST BALCONY ZONE SECOND BALCONY ZONE CATWALK SERVED FROM SECOND BALCONY ZONE DN FIXTURES DRAINS FIRE SUPPRESSION DESIGN NOTES LEGEND FIRE CONTROL EQUIPMENT TYPICAL GAS CONNECTION PUMPER CONNECTION AT EQUIPMENT TRAP PRIMER FREE STANDING SPRINKLER FLOOR CONTROL VALVE GAS RISER SPRINKLER ZONES S MISC. CARRIER MFR. CAT. Nos. D D SEE SPECS CAT. Nos. MFR. 95-SS 95-SS C C SEE FIXTURE SCHED. NOTES P. SUPPLY TRIM SUPPLY/STOP WASTE TRIM N. MFR. A A MFR. UNIT UNIT A A CAT. Nos. MFR. B B MFR. B B CAT. Nos. UNIT UNIT CAT. Nos. INTEGRAL INTEGRAL TRAP/FIX. DR. CAT. Nos. K. J. FIXTURE L. M. WASTE & VENT CAT. Nos. 2257.103 2257.103 A A MFR. TRAP 4" 4" 2" TEPID 4" INT. AIR BREAK AIR GAP WASTE-MIN. VENT-MIN. INDIRECT FIX. DRAIN C.W. HARD FIX OUTLET F. E. G. H. SLOAN "ROYAL" (ZURN, TOTO) SMITH (ZURN, WATTS, JOSAM) OLSONITE (BENEKE, CHURCH, BEMIS, TOTO) AMERICAN STANDARD (KOHLER, ELJER, TOTO) H.W. 120°F 1" RIM 17" TO RIM 15" TO DESCRIPTION C.W. MOUNTING HEIGHT CHICAGO (ZURN, T&S BRASS) WILLIAMS (FIAT, MUSTEE, CREATIVE IND) SUPPLY McGUIRE (EBC, ZURN) HALSEY TAYLOR (ELKAY, OASIS, SUNROC) ELKAY (JUST WITH LUG AND SCREW) D D H V-70, T-35 G 8902DF A G 155A A UNIT A ROUGH A UNIT H UNIT B B B E B E UNIT UNIT UNIT E G H2165LK J LK-35 G 8912DF INTEGRAL INTEGRAL K UNIT G G (2) 8902 D A 6561.017 6561.017 H MTB-2424 A 1.5" 1.5" 2" 2" 1.5" 1.25" 2" 1.5" INT 2" 2" 1.5" 3" 3" 1.5" 2" 3" INT 3" 1.5" 1.5" 1.5" 1.5" 1.5" 1.5" J LR-2219 0.5" 24" TO LIP 17" TO LIP FAUCET 0.5" 36" TO 0.5" 0.5" 0.5" 0.5" K HAC8FSBL-Q-ADA 33" LOW BUBBLER 0.5" B. A. C. D. MARK A1 A2 B1 C1 C2 D1 F1 G1 URINAL/WALL HUNG/1.0GPF MOP BASIN/FLOOR SET/24"x24"x10" FIXTURE SCHEDULE NOTES: 5 COLOR SELECTION BY ARCHITECT. 3 PROVIDE TRUEBRO "LAV GUARD" PIPE COVERING ON EXPOSED SUPPLY AND WASTE PIPING LOCATED BELOW FIXTURE. 1 FIXTURE AND INSTALLATION SHALL CONFORM TO ALL ADA REQUIREMENTS FOR THE HANDICAPPED. 4 PROVIDE CHECK VALVES IN HOT AND COLD WATER SUPPLY PIPING. COUNTERTOP SINK/S.S./SINGLE/22"X19"X7" ELECTRIC WATER COOLER/WALL HUNG/ADA/BI-LEVEL URINAL/WALL HUNG/ADA/1.0GPF CATALOG NUMBERS INDICATED ARE THOSE OF THE FIRST NAMED MANUFACTURER IN EACH CATEGORY LISTED BELOW - ADDITIONAL MANUFACTURERS ARE LISTED IN PARENTHESIS H.W. 140°F 1 G H2165LK 186-1.0-SMO 186-1.0-SMO H2165K K UNIT O. 786-GN2A-E3-369 897-RCF C'TOP LAVATORY/ADA/0.5GPM AMERICAN STANDARD (ZURN, CHICAGO, T&S) A F 6 COORDINATE MOUNTING OF ACCESSORIES WITH ARCHITECT. 111-SMO 111-SMO 0496.300 1480.115 SEE DRAIN SCHEDULE NOTES U'DECK CLAMP BEARING PAN 2" STANDPIPE TRAP PRIMER CON. PLASTIC ACID RESIS. CAST IRON DBL. DRAINAGE FLSHG. CLAMP SED. BUCKET ANCHOR FLANGE STAINLESS STEEL STRAINER/GRATE HINGED STRAINER LESS TOP FUNNEL DOME RECESSED FLAT ADJUSTABLE STAINLESS STEEL NICKEL-BRONZE BODY OUTLET TOP FINISH 3" SIZE SIDE BOTTOM PLASTIC GALVANIZED ACID RESIS. SIZE STAINLESS STEEL TYPE J.R. SMITH (OR EQUAL BY MANUFACTURER ROOF PLANTER FLOOR CATALOG NOS. CAST IRON 4" AUX. STRAINER ADDITIONAL FEATURES MARK DRAIN SCHEDULE NOTES: FD2 RD2 FD1 1015 4" 15"DIA 2110 2005A 3 PLAZA 6"RD 8"DIA 1,2 1,2 CAST IRON GALVANIZED CAST IRON ZURN, JOSAM, WATTS, MIFAB) 1 DRAINS WITHOUT TRAP PRIMERS SHALL HAVE PRIMER OPENINGS PLUGGED. 2 CONTRACTOR SHALL CLOSELY COORDINATE WITH GENERAL CONTRACTOR INSTALLATION OF DRAINS. 3 COORDINATE DRAIN INSTALLATION CLOSELY WITH ROOFING CONTRACTOR. ADJUSTABLE EXTENSION A FIRE SUPPRESSION CONTRACTOR SHALL DESIGN AND INSTALL A COMPLETE AUTOMATIC WET PIPE STANDPIPE AND SPRINKLER SYSTEM THROUGHOUT ALL NEW AREAS OF THE BUILDING. THE FIRE SUPPRESSION CONTRACTOR SHALL ALSO PROVIDE MODIFICATIONS OF AND ADDITIONS TO AN EXISTING WET PIPE SPRINKLER SYSTEM IN THE EXISTING BUILDING TO ACCOMMODATE NEW CONSTRUCTION AS INDICATED ON THE DRAWINGS AND AS OUTLINED IN THE SPECIFICATIONS. B BASIS FOR DESIGN IS LIGHT HAZARD OCCUPANCY EXCEPT MECHANICAL ROOMS, BOILER ROOMS, ALL STORAGE ROOMS, AND KITCHEN SERVICE AREAS WHICH ARE ORDINARY GROUP 1. STAGE, STAGE EXIT STAIRS AND SCENE SHOP ARE ORDINARY GROUP 2. REFER TO THE FLOOR PLANS FOR ADDITIONAL HAZARD OCCUPANCIES. C MINIMUM AREA OF OPERATION FOR LIGHT HAZARD SYSTEMS SHALL BE 1500 SQUARE FEET, .10 GPM/SQ. FT., 225 SQUARE FEET MAXIMUM PER SPRINKLER. FOR ORDINARY HAZARD, 1500 SQUARE FEET MINIMUM AREA OF OPERATION, .15 GPM/SQ. FT. FOR GROUP 1, .20 GPM/SQ.FT. FOR GROUP 2, 130 SQUARE FEET MAXIMUM PER SPRINKLER. A 250 GPM HOSE STREAM ALLOWANCE SHALL BE USED IN THE DESIGN. D PROVIDE SPRINKLER PROTECTION AT EACH FLOOR LEVEL AND THROUGHOUT ALL AREAS AS REQUIRED BY CODE. E ALL PIPING SHOWN SHALL BE INSTALLED AS SIZED. FOR PIPING NOT SHOWN OR SIZED ON THE DRAWINGS, PIPE SIZING SHALL BE BASED ON FIRE SUPPRESSION CONTRACTORS HYDRAULIC CALCULATIONS. MINIMUM SPRINKLER OUTLETS ON PIPING SHALL BE 1". F SPRINKLERS IN AREAS WITH CEILINGS SHALL BE CONCEALED TYPE WITH WHITE FINISH COVER PLATE. UPRIGHT SPRINKLERS TO BE INSTALLED IN EXPOSED STRUCTURAL AREAS. ALL SPRINKLERS TO BE QUICK RESPONSE TYPE. G REFER TO ARCHITECTURAL DRAWINGS FOR CONSTRUCTION AND CEILING TYPES. COORDINATE SPRINKLER LOCATIONS WITH CEILING DEVICES (LIGHTING, GRILLES, ETC..). OBTAIN ARCHITECTS APPROVAL OF SPRINKLER LAYOUT PRIOR TO INSTALLATION. FINAL FINISHED APPEARANCE OF FIRE SUPPRESSION WORK MUST BE APPROVED BY THE ARCHITECT. H FIRE SUPPRESSION CONTRACTOR SHALL PERFORM A FLOW TEST AND OBTAIN APPROVAL FROM GOVERNING AUTHORITIES PRIOR TO STARTING WORK. I FSC SHALL EXERCISE SPECIAL CARE TO COORDINATE PIPING AND EQUIPMENT LOCATIONS WITH ALL OTHER TRADES. J COORDIATE WITH ARCHITECT LOCATIONS OF ALL EXPOSED SPRINKLER PIPING IN SANCTUARY. PROVIDE SPRINKLER PROTECTION ABOVE AND BELOW "CLOUDS" SEE ARCHITECTURAL DRAWINGS FOR LOCATIONS WATER CLOSET/W.H./1.6GPF/BATTERY SENSOR F.V. 0.5" 1.25" 1.5" 1.5" 1.5" 1.5" G 155A G 8902DF RIM 0.5" 34" TO B2 WALL HUNG LAVATORY/ADA/0.5GPM A 0355.012 F 1480.115 G H2165LK 0.75" 0.75" D WATER CLOSET/W.H./1.6GPF/BATTERY SENSOR F.V./ADA F2 COUNTERTOP SINK/S.S./DOUBLE/33"X19"X7"/DISPOSER 0.5" 0.5" 1.5" 1.5" 1.5" 1.5" 1.5" J LR-3319 E 2300-8CP G H2165LK J LK-35 G SEE SPECS GUY GRAY (OATEY, PLASTIC ODDITIES) SIZE AND ACCESSORIES FIRE CONTROL EQUIPMENT SCHEDULE NOTES: 1 CABINET DOOR SWING SHALL BE COORDINATED WITH THE ARCHITECT. CABINET STYLE SEMI-RECESSED STAINLESS STEEL FCE1 MARK STEEL ALUMINUM RECESSED MATERIAL 2.5"-ADJ. REG. 2.5"-DISC. REG 1.5"-INT. REG. 2.5"-INT. REG. 1.5"-DISC. REG. SURFACE MTD. TRIMLESS SOLID PANEL DUO-PANEL GLASS PANEL 2.5" 1.5" DOOR VALVES EXTINGUISHERS SIZE AND TYPE 2.5 GAL.-WATER 1.5"-ADJ. REG. 2.5"X1-1.5"RED. VALVE MTD. HYDROLATOR 1.5"-100 FT. 10# ABC PIPE MTD. WALL MTD. 10# CO2 5# ABC HOSE RACK SIZE & MOUNTING SCHEDULE NOTES WALL BRACKET 1 SEE FCS 5# CO2 9# HALON 13# HALON TYPE "K" PIPE CAP 3" MIN. SHUT-OFF VALVE ON PLANS INDICATED PIPE SIZE AS TP EQUIPMENT CONNECTION UNION EQUIPMENT CONNECTION PIPE SIZE FLOOR TP F P001 PIPING TO FLOOR DRAINS UNLESS NOTED OTHERWISE. SHALL BE RUN BELOW FLOOR, 0.5" WHERE APPLICABLE FLOOR DRAIN FINISHED CEILING WALL TP SUPPLY SHALL BE OFF TOP OF MAIN COLD WATER MAIN INSTALL PIPING CONCEALED INSTALL PIPING TIGHT TO WALL SURFACE IN UNFINISHED AREAS. IN WALL IN FINISHED AREAS. TRAP PRIMER, WITH DISTRIBUTION DRAINS. LOCATE ABOVE CEILING UNIT WHEN SERVING MULTIPLE IN FINISHED AREAS. FCE2 1 RD3 1015 5" 15"DIA 3 RD4 1015 6" 15"DIA 3 RD5 1015 8" 15"DIA 3 RD1 1015 3" 15"DIA 3 A3 WATER CLOSET/F.S./1.6GPF/ADA/FLUSH TANK 0.5" 3" INT. 1.5" A 2386.012 A UNIT G H2166LK A UNIT A INTEGRAL C 95-SS P001 LEGEND, SCHEDULES AND DETAILS P003 SITE PLAN P100 FIRST LEVEL - EXISTING BUILDING - DEMOLITION P200 FIRST LEVEL - EXISTING BUILDING - NEW WORK P201 UNDERFLOOR PLAN - NEW WORK P202 PIT LEVEL - NEW WORK P203 FIRST LEVEL - NEW WORK P204 FIRST BALCONY - NEW WORK P205 SECOND BALCONY - NEW WORK P206 ROOF PLAN P300 SOIL, WASTE AND VENT DIAGRAM C P001 DUCTILE IRON WITH RESTRAINED JOINTS 48" DIA. (VERIFY STYLE WITH AUTHORITY) NEENAH MODEL #R-1643 OR EQUAL FRAME AND COVER 4" GRAVEL OPEN BOTTOM BALL DRIP VALVE GRADE POURED CONCRETE SUPPORT SLOPE FREE STANDING SIAMESE PUMPER CONNECTION 2FT MIN. PRE-CAST MANHOLE INSPECTION TO BALL FOR ACCESS AND DRIP. A P001 2" DRAIN ASSEMBLY SIZE PER HYDRAULIC ALARM TEST & SD F CALCULATIONS FLOW SWITCH P S 4" TO SPRINKLER SYSTEM FLOOR SLAB AROUND PIPE (FROM COPPER WIRE WRAPPED #12 PLASTIC COATED SCALE : NONE B P001 GRADE 2" 1LB. MAGN. ANODE FITTING 36" MIN. TRANSITION PLASTIC STEEL 30" MIN. 12" ATTACH TO RISER ABOVE GRADE BLDG. WALL PVC SLEEVE CAULKED WEATHERTIGHT DIELECTRIC UNION VALVE 2" METER SETTING). A G A UNIT A INTEGRAL C 95-SS 4021.800 A4 WATER CLOSET/F.S./1.6GPF/ADA/FLUSH TANK/FLUSH LEVER ON RT. 0.5" 3" INT. 3" 3" 1.5" A UNIT H2166LK D2 SCULLERY SINK/FLOOR SET/S.S. 0.5" 0.5" 1.5" J SS8124 E 445-L8CP G H2165LK J LK-24RT G 8912DF 4'-0"MIN. SLOPE TO BUILDING 3016.016, 1,2 1,2 1,2,3,8 1,2,3,8 1 4,6 2 2 2,7 1,2,57 2 PROVIDE CHROME PLATED BRASS NIPPLES TO WALL. D3 UTILITY CONNECTION BOX 0.5" L BIM-875 L UNIT BALL VALVE BOTTOM 18" TO SEE SPECS SEE SPECS SEE SPECS SEE SPECS 1.5" 1.5" 1.5" 1.5" 8912DF ISE (WHIRLAWAY) M PRO ES 1.25" 1.5" 1.5" 1.5" 1.5" 7 COORDINATE ELECTRIC REQUIREMENTS WITH EC. 8 PROVIDE WITH 0.5 GPM AERATOR, P002 DETAILS GC GENERAL CONTRACTOR PC PLUMBING CONTRACTOR FSC FIRE SUPPRESSION CONTRACTOR HC HVAC CONTRACTOR EC ELECTRICAL CONTRACTOR SUC SITE UTILITY CONTRACTOR "CONNECT TO EXISTING" SYMBOL 2 "DETAIL NOTE" SYMBOL (FOR NOTES ON SAME DETAIL) 3 "NOTE" SYMBOL (FOR NOTES ON SAME SHEET) A1 "UP TO" SYMBOL (ITEM ON FLOOR ABOVE) WS WATER SERVICE FS FIRE SERVICE GS GAS SERVICE SANITARY DRAINAGE PIPE ST STORM DRAINAGE PIPE TP TRAP PRIMER DISCHARGE PIPE PD PUMP DISCHARGE PIPE SANITARY VENT PIPE DCW COLD WATER PIPE DHW HOT WATER PIPE (120 DEGS. F.) DHWR HOT WATER RETURN PIPE (120 DEGS. F.) SHUTOFF VALVE FLOW CONTROLLER CHECK VALVE UNION DIRECTION OF FLOW DIRECTION OF PITCH G NATURAL GAS PIPE F FIRE SUPPRESSION PIPE S SPRINKLER PIPE (WET) SD SPRINKLER DRAIN PIPE SUPERVISED VALVE FLOW SWITCH ROOF DRAIN ABOVE A2 PLUMBING FIXTURE FD2 DRAIN (FD, AD, DD, RD, PD, OD) FCE2 FIRE CONTROL EQUIPMENT VR VENT RISER CO CLEANOUT VTR VENT THRU ROOF SR SUPPLY RISER HB HOSE BIBB WH WALL HYDRANT DS DOWNSPOUT AFF ABOVE FINISH FLOOR AFG ABOVE FINISH GRADE FR FIRE RISER (STANDPIPE/SPRINKLER) FDC FIRE DEPARTMENT CONNECTION FDV FIRE DEPARTMENT VALVE F.F. FINISH FLOOR ELEVATION INV INVERT ELEVATION PRESSURE GAUGE WITH STOP THERMOMETER DETAIL B SHOWN ON SHEET P2 FDC FIRE DEPARTMENT CONNECTION PIPE FPTH FIRE PUMP TEST HEADER PIPING FS 1" 4" INT. 4" 4" 2" 3" 3" G P001 E P001 P T INDEX OF DRAWINGS Date: Scale Drawn By Checked By Project Number ARCHITECTURE PLANNING INTERIOR DESIGN STRUCTURAL ENGINEERING 424 East Fourth Street Cincinnati, w w w . c h a r c h Ohio i t e c t s . 45202 c o m tel: 513/241/4474 fax: 513/241/0081 ISSUANCES COMPUTER FILE 1400 West Dorothy Lane Dayton, Ohio 45409-1310 Tel: (937) 224-0861 Fax: (937) 224-5777 3417 South Sherman Drive Beech Grove, IN 46107 Tel: (317) 780-1555 Fax: (317) 780-6525 750 North Orleans, Suite 400 Chicago, IL 60610 Tel: (312) 944-8230 Fax: (312) 944-8297 117 East Washington Street, Suite 200 Indianapolis, IN 46204 Tel: (317) 637-2222 Fax: (317) 637-2260 1137 West Taylor St. Suite 316 Chicago, IL 60607 Tel: (312) 224-8460 Fax: (312) 224-8961 1025 N.Watery Ln. Brigham City, UT 84302 TEL: (453) 723-5000 FAX: (453) 538-5506 6622 Kingspointe Parkway Orlando, FL 33819 Tel: (407) 816-9400 Fax: (407) 816-9300 1 SCHEMATIC DESIGN 10.18.07 2 DESIGN DEVELOPMENT 01.18.08 3 CD 50% 03.14.08 4 PERMIT SET 04.25.08 5 ADDENDUM #2 05.16.08 No. Description Date 6 ADDENDUM #3 05.22.08 7 ADDENDUM #5 06.04.08 8 PERMIT SET 06.10.08 6/10/2008 2:18:49 PM C:\Drawings\revit\Northivew Church\2007-06019-Central-LOCAL.rvt P001 LEGEND SCHEDULES AND DETAILS New Worship Center TWN ATM 05-22-08 2007-06019