HomeMy WebLinkAboutP202 - PIT LEVEL - NEW WORKM UP UP UP UP F.E.C. F.E.C. F.E.C. DN DN UP UP 4" FR UP, 2.5" FR DN 4" FR UP 2.5" FR DN FDV B1 FDV A4 B1 RD3 5" DS 3,170 SQ.FT. 5" STORM 3,170 SQ.FT. 4,615 SQ.FT. 6" STORM 6" DS 4,615 SQ.FT. 2.5" FR UP FDV 2.5" FIRE B2 B2 A3 G1 F1 D1 FD2 FD2 2" GAS @ 2 PSI 2" GAS @ 2 PSI 5 4 10 10 1 2 0.5" DHW 0.75" DCW VTR WH 0.75" DCW F2 3 6" FR UP 6" FIRE 6" FIRE PUMP TEST HEADER PIPING 6" FIRE SERVICE 0.5" DCW 0.5" DHW 1.5" DCW, 1" DHW & 0.75" DHWR FROM BELOW 0.5" DHW 0.5" DCW WH 0.75" DCW 0.75" DCW 1" DCW 1.25" DCW 1.5" DCW 0.75" DHW 0.75" DHWR 0.75" DHW 1" DHW 8" DS 11,105 SQ.FT. 8" STORM VTR 1,530 SQ.FT. RD2 4" STORM 4" STORM 8"DS 25,735 SQ.FT. 8" DS 11,735 SQ.FT. RD2 1,360 SQ.FT. 8" STORM 9 9 11 12 13 D3 1.5" GAS 13 8 FD2 FD2 FD2 6" FIRE 4" FIRE 6 7 S FS S FD1 FD1 14 RD1 400 SQ.FT. 3" STORM 3" DS 400 SQ.FT. Date: Scale Drawn By Checked By Project Number ARCHITECTURE PLANNING INTERIOR DESIGN STRUCTURAL ENGINEERING 424 East Fourth Street Cincinnati, w w w . c h a r c h Ohio i t e c t s . 45202 c o m tel: 513/241/4474 fax: 513/241/0081 ISSUANCES COMPUTER FILE 1400 West Dorothy Lane Dayton, Ohio 45409-1310 Tel: (937) 224-0861 Fax: (937) 224-5777 3417 South Sherman Drive Beech Grove, IN 46107 Tel: (317) 780-1555 Fax: (317) 780-6525 750 North Orleans, Suite 400 Chicago, IL 60610 Tel: (312) 944-8230 Fax: (312) 944-8297 117 East Washington Street, Suite 200 Indianapolis, IN 46204 Tel: (317) 637-2222 Fax: (317) 637-2260 1137 West Taylor St. Suite 316 Chicago, IL 60607 Tel: (312) 224-8460 Fax: (312) 224-8961 1025 N.Watery Ln. Brigham City, UT 84302 TEL: (453) 723-5000 FAX: (453) 538-5506 6622 Kingspointe Parkway Orlando, FL 33819 Tel: (407) 816-9400 Fax: (407) 816-9300 1 SCHEMATIC DESIGN 10.18.07 2 DESIGN DEVELOPMENT 01.18.08 3 CD 50% 03.14.08 4 PERMIT SET 04.25.08 5 ADDENDUM #2 05.16.08 No. Description Date 6 ADDENDUM #3 05.22.08 7 ADDENDUM #5 06.04.08 8 PERMIT SET 06.10.08 1/8" = 1'-0" 6/10/2008 2:19:37 PM C:\Drawings\revit\Northivew Church\2007-06019-Central-LOCAL.rvt P202 PIT LEVEL - NEW WORK New Worship Center TWN ATM 05-22-08 2007-06019 1/8" = 1'-0" 1 PIT LEVEL - NEW WORK GENERAL NOTES A ALL PIPING SHOWN IS LOCATED ABOVE SUSPENDED CEILINGS (AT THE UNDERSIDE OF STRUCTURE IN EXPOSED STRUCTURAL AREAS) UNLESS INDICATED OTHERWISE. B REFER TO DETAILS, DIAGRAMS AND SCHEDULES FOR PIPING AND PIPE SIZES NOT SHOWN. C PC SHALL COORDINATE INSTALLATION CAREFULLY WITH ALL OTHER TRADES. D ANNULAR SPACE OF PIPE, CONDUIT AND OTHER SIMILAR PENETRATIONS OF FIRE RATED ASSEMBLIES SHALL BE FIRESTOPPED. IN ADDITION, PENETRATIONS THRU 0-HOUR RATED FLOORS SHALL ALSO BE FIRESTOPPED TO RETARD PASSAGE OF FIRE AND SMOKE. REFER TO ARCHITECTURAL DRAWINGS FOR CONSTRUCTION, LAYOUT AND FIRE RATINGS OF FLOORS, WALLS, PARTITIONS AND OTHER BUILDING ELEMENTS. E FINISHED FLOOR ELEVATION: PIT LEVEL - 808.64' F PROVIDE INDIVIDUAL SHUT-OFF VALVES FOR ALL BASEMENT FIXTURES. NOTES 1 DOMESTIC WATER SERVICE. SEE DETAIL B ON SHEET P002 2 PROVIDE 1" RPZ BACKFLOW PREVENTER FOR HVAC MAKE-UP WATER. ALL DOWNSTREAM PIPING BY HC. 3 PIT LEVEL DOMESTIC WATER HEATER. SEE DETAIL E ON SHEET P002 FOR EQUIPMENT, DEVICES AND PIPE SIZING. 4 PROVIDE OVERSIZED SLEEVE THRU WALL FOR GAS PIPING ENTERING BUILDING AND CAULK WEATHERTIGHT. SEE DETAIL B ON SHEET P001. 5 PROVIDE ISOLATION VALVE FOR SPRINKLER AT BOTTOM OF ELEVATOR PIT. 6 SPRINKLER FLOOR CONTROL VALVE BY FSC. SEE DETAIL A ON SHEET P001. 7 TO SPRINKLERS SERVING PIT LEVEL. COORDINATE LOCATIONS OF ALL SPRINKLER PIPING AND DEVICES CAREFULLY WITH ALL OTHER TRADES. 8 30 HP, 750 GPM VERTICAL INLINE FIRE PUMP PACKAGE. SEE DETAIL A ON SHEET P002. 9 RISER ISOLATION VALVE WITH SUPERVISORY SWITCH BY FSC. 10 PROVIDE VALVE, DIRT LEG, REGULATOR, UNION AND CONNECT TO HVAC BOILER PROVIDED BY HC. REGULATOR SHALL BE SIZED CAPABLE OF FLOWING 1,800 CFH WITH 2 PSI INLET PRESSURE AND 7" W.C. OUTLET PRESSURE. GAS REGULATORS TO VENT TO OUTSIDE. 11 PROVIDE STANDPIPE WITH 1.5" P-TRAP AND 6" OF 2" PIPING UNDER COUNTER FOR HVAC CONDENSATE PIPING. 12 2" PUMPED DISCHARGE FROM SUMP PUMP AT BOTTOM OF LIFT PIT TO RISE UP TIGHT TO WALL AND DISCHARGE OVER MOP BASIN. 13 PROVIDE TRAP PRIMER WITH DISTRIBUTION UNIT. DISCHAGE PIPING TO DROP TIGHT TO WALL TO UNDER FLOOR TO SERVE FLOOR DRAINS. 14 PROVIDE TRAP PRIMER WITH DISTRIBUTION UNIT ABOVE CEILING. DISCHARGE PIPIGN SHALL DROP CONCEALED IN WALL TO BELOW FLOOR AND SERVE TOIELT ROOM FLOOR DRAINS.