Loading...
HomeMy WebLinkAboutP203 - FIRST LEVEL - NEW WORKDN DN UP UP DN UP UP DN F.E.C. F.E.C. F.E.C. F.E.C. DN UP FDV FDV 4" FR 4" FR FCE1 4" FR UP 2.5" FR DN D1 A2 A2 A2 A2 A2 A2 A2 A1 A2 B1 B1 B1 B1 B1 A1 A2 A2 A2 B1 B1 D1 B1 A2 B1 B1 B1 C1 C2 C2 A2 4" FIRE 6" FR FCE2 FCE2 FCE1 4" FR VTR D2 C2 FD1 FD1 VR VR VR VR FD1 3" STORM 6" DS 7,945 SQ.FT. 5" STORM FD1 A1 5" STORM VTR VR FIRE PUMP TEST HEADER FROM FDC CHECK VALVE 4" FDC RD3 RD3 RD1 1,030 SQ.FT. 8" DS 8" DS 11,735 SQ.FT. 11,105 SQ.FT. FD2 1 2 7 WH 3,075 SQ.FT. 6" STORM 3" STORM 0.75" DCW 6" FIRE 0.75" DCW 3,340 SQ.FT. 0.5" DCW & DHW 1" DCW 0.75" DHWR 0.75" DHW 1" DCW 6" FIRE 2" SPRINKLER DRAIN 5 WH 5" DS 4,350 SQ.FT. 0.75" DCW 4" FIRE 0.75" DHWR 0.75" DHW 1" DCW 6" FIRE 4" DS 1,790 SQ.FT. 2.5" DCW FROM BELOW 4 4" STORM RD3 5" STORM 5" DS 2,260 SQ.FT. RD3 2,660 SQ.FT. 5" STORM 1" 4 1.25" 3 1.5" 9 8 6 1.25" DCW 1.5" DCW 1.25" DHW 0.75" DHWR 4" FIRE 0.5" DCW 0.5" DHW 1.5" DCW 0.5" DHW 0.75" DHW 10 10 10 10 VTR VTR 3 13 2" 3 6 0.75" DCW WH 2.5" DCW 1" DHW 0.75" DHWR 4" FIRE 1.5" DCW 2" 2.5" DCW 1.25" DHW 0.75" DHWR 2,560 SQ.FT. 11 S S 11 2" SD 12 G1 C2 RD1 500 SQ.FT. 3" STORM Date: Scale Drawn By Checked By Project Number ARCHITECTURE PLANNING INTERIOR DESIGN STRUCTURAL ENGINEERING 424 East Fourth Street Cincinnati, w w w . c h a r c h Ohio i t e c t s . 45202 c o m tel: 513/241/4474 fax: 513/241/0081 ISSUANCES COMPUTER FILE 1400 West Dorothy Lane Dayton, Ohio 45409-1310 Tel: (937) 224-0861 Fax: (937) 224-5777 3417 South Sherman Drive Beech Grove, IN 46107 Tel: (317) 780-1555 Fax: (317) 780-6525 750 North Orleans, Suite 400 Chicago, IL 60610 Tel: (312) 944-8230 Fax: (312) 944-8297 117 East Washington Street, Suite 200 Indianapolis, IN 46204 Tel: (317) 637-2222 Fax: (317) 637-2260 1137 West Taylor St. Suite 316 Chicago, IL 60607 Tel: (312) 224-8460 Fax: (312) 224-8961 1025 N.Watery Ln. Brigham City, UT 84302 TEL: (453) 723-5000 FAX: (453) 538-5506 6622 Kingspointe Parkway Orlando, FL 33819 Tel: (407) 816-9400 Fax: (407) 816-9300 1 SCHEMATIC DESIGN 10.18.07 2 DESIGN DEVELOPMENT 01.18.08 3 CD 50% 03.14.08 4 PERMIT SET 04.25.08 5 ADDENDUM #2 05.16.08 No. Description Date 6 ADDENDUM #3 05.22.08 7 ADDENDUM #5 06.04.08 8 PERMIT SET 06.10.08 1/8" = 1'-0" 6/10/2008 2:20:03 PM C:\Drawings\revit\Northivew Church\2007-06019-Central-LOCAL.rvt P203 FIRST LEVEL - NEW WORK New Worship Center TWN ATM 05-22-08 2007-06019 GENERAL NOTES A ALL PIPING SHOWN IS LOCATED ABOVE SUSPENDED CEILINGS (AT THE UNDERSIDE OF STRUCTURE IN EXPOSED STRUCTURAL AREAS) UNLESS INDICATED OTHERWISE. B REFER TO DETAILS, DIAGRAMS AND SCHEDULES FOR PIPING AND PIPE SIZES NOT SHOWN. C PC SHALL COORDINATE INSTALLATION CAREFULLY WITH ALL OTHER TRADES. D ANNULAR SPACE OF PIPE, CONDUIT AND OTHER SIMILAR PENETRATIONS OF FIRE RATED ASSEMBLIES SHALL BE FIRESTOPPED. IN ADDITION,PENETRATIONS THRU 0-HOUR RATED FLOORS SHALL ALSO BE FIRESTOPPED TO RETARD PASSAGE OF FIRE AND SMOKE. REFER TO ARCHITECTURAL DRAWINGS FOR CONSTRUCTION, LAYOUT AND FIRE RATINGS OF FLOORS, WALLS, PARTITIONS AND OTHER BUILDING ELEMENTS. E FINISHED FLOOR ELEVATION: FIRST LEVEL - 817.64' F PROVIDE INDIVIDUAL SHUT-OFF VALVES FOR EACH FIXTURE AND/OR FOR EACH PIPE DROPPING TO EACH GROUP OF FIXTURES AS REQURED. NOTES 1 SPRINKLER FLOOR CONTROL VALVE BY FSC. SEE DETAIL A ON SHEET P001. 2 TO SPRINKLERS SERVING FIRST FLOOR. COORDINATE LOCATIONS OF ALL SPRINKLER PIPING AND DEVICES CAREFULLY WITH ALL OTHER TRADES. 3 DCW PIPING TO DROP IN CHASE. PROVIDE FULL SIZE MANIFOLD AND SERVE EACH WATER CLOSET FLUSH VALVE INDIVIDUALLY FROM MANIFOLD. 4 DCW PIPING TO DROP IN CHASE. PROVIDE FULL SIZE MANIFOLD AND SERVE EACH URINAL FLUSH VALVE INDIVIDUALLY FROM MANIFOLD. 5 SPRINKLER DRAIN PIPING TO DROP TO NEAR FLOOR LEVEL. PIPING SHALL EXIT BUILDING 6" A.F.F. AND ELBOW DOWN. PROVIDE CONCRETE SPLASHBLOCK BELOW OUTLET. 6 0.5" DCW AND DHW TO DROP IN CHASE AND SERVE LAVATORIES. 7 PIPING TO DROP IN CHASE AND SERVE HOSE BIBB MOUNTED 36" A.F.F. PROVIDE TRAP PRIMER NEAR CEILING. DISCHARGE PIPING TO DROP IN CHASE TO BELOW FLOOR AND SERVE ADJACENT FLOOR DRAIN. 8 PROVIDE FLOW CONTROLLER IN PLUMBING HOT WATER RETURN PIPING. EACH FLOW CONTROLLER SHALL BE 0.75" SIZE AND FLOW 1 GPM EACH. 9 FIRST LEVEL DOMESTIC WATER HEATER. SEE DETAIL ON SHEET P002. 10 PROVIDE TRAP PRIMER FLUSH TUBE AS MANUFACTURED BY FLUSH VALVE MANUFACTURER. DISCHARGE PIPING SHALL DROP IN CHASE TO BELOW FLOOR AND SERVE ADJACENT FLOOR DRAIN. 11 RISER ISOLATION VALVE WITH SUPERVISORY ATTACHMENT BY FSC. 12 2" PUMPED DISCHAGE FROM ELEVATOR PIT SUMP PUMP TO RISE UP TIGHT TO WALL AND DISCHARGE OVER MOP BASIN. 13 0.75" DCW AND 0.5" DHW TO DROP IN CHASE AND SERVE LAVATORIES AND DRINKING FOUNTAIN.