Loading...
HomeMy WebLinkAboutCorrespondence HAMILTON COUNTY HIGHWAY DEPARTMENT February 13, 2008 py Mr. Eric Batt The Schneider Corporation 8901 Otis Avenue Indianapolis, IN 46216-1037 RE: Stafford Lane Entrance Secondary Plat S of 146th Street / W of Gray Road Clay Township Dear Mr. Batt: After reviewing the Secondary Plat the Highway Department has the following comments: 1. A 75' half Right-of~Way is required per the Hamilton County Thoroughfare Plan. Triangular corner cuts of 50' are needed at the entrance. 2. Upon review of the recent Court decision, we feel that the existing drive, located on the west side of the parcel, should be used as the entrance for Stafford Lane. 3. Minimum requirements for the entrance include a 150' deceleration lane with a 100' taper, a 100' acceleration taper and curb return radii of 35'. If these minimums cannot be achieved, the Highway Departmentwill not support an entrance at this location The Board of Hamilton County Commissioners will have final approval of any access to 146tl1 Street. 4. Additional comments may be needed at a later date. If you have any questions or comments concerning this letter, please feel free to contact me at anytime. ~jnc r Iy, (. '.c'. '0 avidE L~ Staff Engineer DL:dl 02-13-08.a cc: Jim Neal G:\USERS\del\Subdivisions\Clay\staffordlane 2-13-08 1700 South 10lh Street Noblesville, In. 46060 wwW.co.llamiIton.in.us Office (317) 773-7770 Fax (317) 776-9814 Conn. Angelina V From: Sent To: Subject: David Lucas [del@ca.hamiltan.in.us] Monday, November 05, 2007 11 :56 AM Conn, Angelina V RE: Stafford Lane My main concern 1S R/W. It doesn't appear to be Thoroughfare Plan quantity on the plans. Just so you're aware, there are some major issues with the entrance. We're trying to work them out with Schneider. Thank you for all of your help! >>> "Conn, Angelina V" <Aconn@carmel.in.gov> 11/5/2007 11:35 AM >>> Some revisions requested are: 1. Urban 2. 3. A copy of the landscape plan approval letter/e-mail from the Forester is required prior to Secondary Plat approval. Add Docket Numbers to Plat (06020010 PP and 06100007 sp). Provide source of title, instrument no. And so on..... it is minor technical stuff.... Angie Conn, Planning Administrator Dept. of Community Services - Planning & Zoning 1 Civic Square, 3rd Floor City of Carmel, IN 46032 p. 317-571-2417 f. 317-571~2426 aconn@carmel.in.gov -----Original Message----- From: David Lucas [mailto:del@co.ha~ilton.in.us] Sent: Monday, November 05, 2007 10:54 .AM To: Conn, Angelina V Subject: RE: Stafford Lane Do you know what the changes to the mylar happen to be? >>> "Conn, Angelina V" <Aconn@carmel.in.gov> 11/5/2007 10:45 AM >>> David: The primary plat, docket no 06020010 PP, received plan commission approval on 5/16/2006, and the secondary plat (SP), docket no 06100007 sp, is still pending; we are waiting for revisions to the mylar. I think that SP application was filed sometime in October of 2006. Thanks, Angie Conn, Planning Administrator Dept. of Community Services - Planning & Zoning 1 Civic Square, 3rd Floor City of Carmel, IN 46032 p. 317-571-2417 f. 317-571-2426 aconn@carmel.in.gov -----Original Message----- From: David Lucas [mailto:del@co.hamilton.in.us] Sent: Monday, November 05, 2007 10:40 AM To: Conn, Angelina V Subject: Stafford Lane Angie, Good morning. Could you tell me what approvals have been given for Stafford Lane. It 1 u u EL . ~\ hEeE/VA Alli .-lJ r; 27 P." /" j/71 DOCS August 24, 2007 JAMES BRAINARD, MAYOR Mr. Eric W. Batt, PE The Schneider Corporation Historic Fort Harrison 8901 Otis Avenue Indianapolis, IN 46216-] 037 o~ OO<f" \0 S' RE: Stafford LaDe Construction Plans-Project Review #2 Dear Mr. Batt: The City has received your comment letter and drawings dated June 20, 2007 based upon the City review of October 19,2006. The comments from the City review have been satisfactorily addressed with the fonowing exceptions: COMMENTS - CONSTRUCTION PLANS 14. Please add detail for City standard multi-use path to Sheet CBOI. Please add detail required by County. ] 7. Please indicate construction of lo-foot multi-use path across frontage of 14~ Street, I foot off of proposed right-of-way. Connect path to existing path at limits offtontage. Please eoBlfuaue to work witb County to instan path lfrequired. ] 8. Curb joint detail on C801 shall be revised to SO' maximum spacing for expansion joints and 10' maximum spacing on contraction joints. Also revise note 7 on CIOl and CI02. 30. Board of Public Works and Safety approval is required for each curb cut ofa public street for the private driveway. Portion of driveway within right-of-way of public street shall be concrete meeting requirements of detaill2lC80 I. Wa1k across these areas shall be 6" concrete in accordance with detaillo/caOI. Restate commellt. This eomment refen to where the existing internal drive crosses Queeuborough aDd PrevaD. 35. The plans lack the required dnUnage summary per the Storm Water Technical Standards Manual. The DepartDlent could Dot locate this InforDlation. Based on additional information, the City provides additional comments: 1. Replace details 1,2,3, S, II, and 12 on Sheet caol with City standard details. 2. Replace detail 9/CS02 with detail from City website. 3. Add minimum cover notes to detail S/C802 and "ITPICAL WATER MAIN INST ALLA nON" detail on C703. 4. Add note to detail 8SD.l on ca08 requiring 6" pipe to be double wal~ smooth interior corrugated, perforated HOPE pipe, Hancor Hi-Q or equivalent. S. Revise sanitary specification note 8 on C901 to conform. to City standard backfill specifications. 6. Thank you for making the revisions for the pond. A formal variance from the BPW &.8 is required. The Department will support the variance provided that the pond is to feet minimum depth over as large an area as possible. and, contrw)' to my e-mail on 2/6/07 related to aeration, the Department requests an alternative to mechanical aeration is provided. Please contact Amanda Foley. The City would also like it written into the covenants that the ROA will maintain the pond free from any algae and weeds or ran1c vegetation as defined in City Code. DEJ'ARTMENT OF ENGINEEHlNG ONE CIVIC SQUARE, CARMEL, IN 46032 OFFICE 317.571.2441 FAX 317.571.2439 EMAIL engineering@carmeLin.gov ~ u u 7. Have comments #5 and #7 from previous Crossroad Engineers review letter been resolved? These comments represent the Department of Engineering's second review of the construction plans for this project. We request that all responses to our comments be provided in writing. Failure to provide written responses may result in the delay of the review process. It is critical that our office be made aware of all modifications made on the plans being resubmitted, particularly if any such changes are considered "new" or fall outside of our previous reviews. Please provide revised plans including all revisions. Please notify us of any changes and specifically state any changes, including changes resulting from Plan Commission, BZA or other committee meetings. All bonds and performance guarantees must be posted prior to Engineering Department approval of construction plans. Also, Board of Public Works and Safety approvals and any other governing agency approvals (ifrequired) must be obtained prior to Engineering Department approval. The Department reserves the right to provide additional comments based on subsequent reviews. If you have questions, please call me at 57182441. Sincerely, G~0~~1 Assk~~f Engineer (- Department of Engineering , I J.:.o. I',. ~ cc: Angelina Conn, Department of Community Services John Duffy, Carmel Utilities Paul Pace, Carmel Utilities Paul Amone, Carmel Utilities Greg lIko, Crossroad Engineers Drees Homes Project File Engineering Department Review S:\DHILL\PROJREY07\ST AFFORDLANECONST#2 w U 'OlIltO<OO.b-~ ,~p --~ 0" October 26, 2006 Mr. Eric W. Batt, PE The Schneider Corporation Historic Fort Harrison 8901 Otis Avenue Indianapolis, IN 46216-1037 RE: Stafford Lane Subdivision Dear Mr. Batt: The following letter represents conunents from the Engineering Department for this project specifically addressing the areas of storm water quality. We have reviewed the construction plans submitted for this project for the October 18, 2006 Technical Advisory Conunittee and offer the following comments: BONDING REQillREMENTS 1. The following bonding requirements apply to this project: Performance Guarantees An Erosion and Sediment Control Performance Guarantee is needed for this project. STORMWATER QUALITY REVIEW COMMENTS-CONSTRUCTION PLANS The following items of the storm water pollution prevention plan have not been satisfied: H2. Sequence describing storm water quality measure implementation relative to land disturbing activities Include seeding ofthe entire site after final grading is completed and streets are constructed. Rear-yard swales and pond slopes shall be stabilized with erosion control blankets and seeded as soon as they are constructed. Silt fence should be installed around all of the rear-yard swales before home constmction begins. Include building construction. All of the permanent post construction BMPs will need to be cleaned at the end of all building construction in the subdivision. Where is the referenced tree preservation area? Where will the curb inlet and beehive inlet protection be placed prior to any grading occurring as referenced in the sequence? Are there inlets in adjacent subdivisions where there is a potential for stormwater from this construction site to flow to these inlets? If so, identify these inlets on the plans. B5. Sediment control measures for concentrated flow areas Erosion control blankets are needed in the swales for stabilization immediately after the swales are at constructed. B7. Runoff control measures A plan is needed establishing and showing measures to be taken before any grading occurs. There are several areas throughout the site where water is currently leaving, according to the existing topography. These areas all need to be addressed before and during grading of the site. There are a few locations where silt fence is needed along the west side. Silt fence will not be adequate w u along most of the east side. Diversion benns directing \Vater to a sediment basin in the southwest comer of the site would bc more appropriate. The small drainage way in the common area at the north of the development needs to be protected. Bll. Temporary surface stabilization methods appropriate for each season Mulch should be applied with all seed. BU. Permanent surface stabilization specifications Mulch should be applied with all seed. B14. Monitoring and maintenance guidelines for each proposed stormwater quali(y measure Only include practices applicabLe to this development. Include a regular street sweeping schedule. H15. Erosion and sediment control specifications for individual lots This detail was not found on C803. Specify that streets along lot frontage shall be cleaned at the end of every work day. Perimeter protection should be installed before excavation of basement/foundation has begun. Perimeter protection on lots shall remain in place until the lot is stabilized Witll at least 70% cover. All trash and construction debris shall be disposed properly into an enclosed waste receptacle. The following items from Pan,C of the Storm Water Pollution Prevention Plan, specifically addressing post construction, have not been addressed. The City of Carmel requires all water leaving a site, post- construction, be treated by a minimum of two water quality BMPs (as in a treatment train). Outline exactly what post-collstmction BMPs have been planned for this development and will be constructed/installed. Specific requirements for water quality ponds, swales, etc. can be found in the City of Camlel Stormwater Technical Standards Manual Chapter 700. Once these BMPs have been established, please address the following items: C2. Sequence describing stormwater quality measure implementation Include the sequence for installing the post construction water quality BMPs with respect to the rest of construction. C3. Description of proposed post construction stonnwater quality measures Identify the specific post-construction BMPs for this project. C4. Location, dimensions, specifications, and construction details of each storm water quality measure lnclude all of the calculations, locations, details and specifications for the proposed post-construction BMPs. CS. Description of maintenance guidelines for post construction storm water quality measures An O&M maIlual specifyi'ng information regarding maintenance of all of the water quality BMPs is needed. An owner acknowledgement agreement for the BMPs has been included and should be completed and submitted with the O&M manual. We request that all responses to our comments be provided in writing. Failure to provide written responses may result in delay of the review process. It is critical that this office be made aware of all modification made on the plans being re-submitted, particularly if any such changes are considered "new" or fall outside of our previous reviews. Please provide revised plans indicating all revisions. Please notify us of any changes and specifically state any changes, including changes resulting from Plan Commission, Special Studies or other committee meetings. All bonds and performance guarantees (ifrequired) must be posted prior to Engineering Department approval. Also, Board of Public Works and Safety approval and any other governing agency approvals (if required) must be obtained prior to Engineering Department approval. The Department of Engineering reserves tlle right to provide additional comments based on subsequent reviews. If you have questions, please contact the Engineering Department at 571-2441. u LJ .. Sincerely, Amanda Foley Storm Water Administrator Depmtment of Engineering cc: Matt Gritlin Project File >.~ u u ", CI EL '1 \ . \ \ ." >----- .. ... " <'7<r;;. - - \ v~>;:: October 19, 2006 JAMES BRAINARD, MAYOR ..I' :1- ~.~/,) ./0. ">> C. ':; )I.". .t. ~,..-;'" ...,~l~ ~. t I ! , , , / Mr. Eric W. Batt, PE The Sclmeider Corporation Historic Fort Harrison 8901 Otis Avenue Indianapolis. IN 46216-1037 'RE:~'~Sta'{o.~ r:ali~C(jDstrUCti~D~Plan5;Pr:O~~~ Dear Mr. Batt: We have reviewed the construction plans and secondary plat submitted for this project for review for the October 18, 2006 Teclmical Advisory Committee. We offer the following comments: GENERAL INFORMATION 1. The project site is located within current City of Carmel Corporate Limits. 2. Jurisdictions: . Streets and Right of Way Interior Streets - City of Carmel l461h Street - Hamilton County Highway Department o Water - City of Carmel Utilities Q Sanitary Sewers - City of Carmel Utilities It Stonn SewerslDrainage - City of Carmel .. Regulated! Legal Drains - Hamilton County Surveyor's Office. 3. Board of Public Works and Safety Requirements: It Water and Sanitary Sewer Availability approval from the Board is based upon the total number of single-family residences @ 1.0 EDU/single family residence. If entryWay or other community irrigation systems are planned, these will also require additional Water Availability approval from the Board and additional Water Connection Fees will be assessed. If a community pool and/or clubhouse is planned, these will require additional Water and Sanitary Sewer Availability approval from the Board and additional Water and Sanitary Sewer Connection Fees will be assessed. It The pennanent entrance at 146l1l Street will require approval by the Hamilton County Highway Department . Temporary Construction Entrance-If located on 1461b Street, this entrance will require approval by the Hamilton County Highway Department. Iflocated anywhere else on the site other than I461b Street, the temporary entrance will require City of Carmel Board of Public Works and Safety Approval. I) Please be adllised that iDlY open cuts of existing interior-dedicated streets will require separate Boud of Public Works and Safety approvaL Open cuts in the dedkated right of way ofU(/' Street are "nder the jurisdictWn of the HamJlton County Highway Department I) Any pennanent improvement (including irrigation systems) to be installed within dedicated right of way or dedicated easements. This approval would require a Consent to Encroach Agreement between the Owner and the City of Carmel. It Secondary Plat approval. DEPARTMENT OF ENGINEERING ONE CIVIC SQUARE, CARMEL, IN 46032 OFFICE 317.571.2441 EMAIL engineering@carmeUn.gov FAX 317.571.2439 u u o Right of Way Dedication (ifapplicable) A schedule for Board of Public Works and Safety meeting dates is enclosed for your use. Please use the Engineering Department deadlines for submissions to the Board. Any submission to the Board requirea prior approval by the Cannel Clay Plan Commission and/or the Board of Zoning Appeals (If applicable) and completion of review by the Technical Advisory Committee. AU written requests to be placed on the Board's agenda must include the appropriate Docket Number and the date (or dates) of approval by the Plan Commission and/or the Board of Zoning Appeals (If applicable). 4. T.A.C. ReviewlDrawings submitted for approval: We request that all comments and conunent letters generated by this office be answered in writing and be accompanied by a drawing reflecting requested revisions. Final drawings will not be approved for construction WItil all Engineering Department and Carmel Utilities issues have been resolved. The design engineer must certify all drawings submitted for final approval. We require a minimwn of five-sets of drawings for approval after aLL issues have been resolved. The drawings will be stamped as approved and will be signed by the City Engineer and by Carmel Utilities. Four approved sets are to be returned to the City of Carmel. The Developer wiLL receive one approved set. If the Developer wishes additional approved sets, we will approve a maximum of two additional sets totaling seven sets. However, the additional sets must be submitted with the minimum required five sets. 5. Please be advised that any installation of signs, walls, irrigation systems, etc. within dedicated right of way, with the exception of 146111 Street, or dedicated easements wiLL require a Consent to Encroach Agreement with the City of Carmel's Board of Public Works and Safety. 6. Carmel UtilitiesIWater DistributionlWastewater Collection should be provided copies of all drawings and revisions for review of water and sanitary sewer issues. They will provide a separate review regarding these issues. Please assure that drawings are provided to: Paul Pace, Water Distribution Paul Arnone, Wastewater Collection Carmel Utilities Carmel Utilities 130 1st Avenue SW 901 North Rangeline Road Carmel, IN 46032 Carmel, IN 46032 7. Carmel Utilities does subscribe to "Holey Moley" and they should be contacted directly for all water main and sanitary sewer main locations. 8. We are enclosing copies of the following: D Subdivision Project Approval Procedures III Perfonnance Release Procedure . Subdivision Building Permits II Permit Data, Contacts, etc. o Subdivision Signage Requirements BONDING REOUIREMENTS 9. Upon initial review, it appears the following bonding requirements may appLy to this project: Performance GnaranteeslEngineer's Estimates Individual Performance Guarantees will be required for the following subdivision improvements: Ii) Interior Streets · Curb & Gutters · Water MaiDs · Sanitary Sewers · Storm Sewers/Storm Drainage · Street Name Signs (do not include traffic control signage) o Monuments & Markers (perimeter corner monumentation and street markers) II Interior Sidewalks (builder's lot sidewalks in right of way) · Exterior Sidewalks/Asphalt Paths (concrete sidewalks/asphalt paths in right of way adjacent to common areas or perimeter roads). o Erosion Control. Please contact Amanda Foley, Department of Engineering Stonn Water Administrator, for information regarding erosion control bonding u u The amount of the Performance Guarantee is based upon a certified Engineer's Estimate for 100% of the cost of labor and materials to construct the individual improvements, to be provided by the design engineer. Please provide detailed Engineers Estimates for each improvement including unit costs, quantities, materials and types of materials, etc. Upon completion and release of individual Performance Guarantees, a three-year Maintenance Guarantee will be required. The Maintenance Guarantee amount is based upon 15% oftbe Performance amount for Streets and Curbs and 100/0 of the Performance amount for all other improvements. Performance Guarantees may be Performance or Subdivision Bonds or Irrevocable Letters of Credit. Please reference the enclosures for more detailed explanation of our procedures. Right of Way Permit and Bonding Any work in the dedicated right of way of any adjacent interior street will require a Right of Way Permit. If the work is included in the scope of work of a posted Performance Guarantee, the Performance Guarantee may be used to satisfY the Right of Way Permit bonding requirements and no additional bonding will be required. If it is not included, a License & Permit type Right of Way bond will be required in the amount of$2,000.00 per instance of work in the right of way. Any open cut in the pavement of adjacent dedicated interior streets will require separate Board of Public Works and S.fety approval. Any work in tbe dedicated rigbt of way of 1~ Street will require permitting tbrough tbe Hamilton County Highway Department. 10. We have engaged Crossroad Engineers, PC to review all drainage plans and drainage calculations submitted to this office for review. We will share Crossroad's comments as they are received. If you have not already done so, please provide one set of plans and calculations to the Department of Engineering and one set to Crossroad Engineers, PC. Please contact Crossroad Engineers to obtain drainage review checklist for consideration in developing secondary plat and that design effort. AVAILABILITY AND CONNECTION FEES II. Availability (acreage) Fees must be paid after all other Engineering Department requirements bave been satisfied and prior to the start of construction activities. Availability Fees are based upon total plattedllegal description acreage for the development at the current rates of$I,O 1 0.00 per acre (Water Availability Fee) and $1,365.00 per acre (Sanitary Sewer Availability Fee). Based upon the acreage indicated on the legal description on the secondary plat, the following Availability Fees would apply: Water - 29.04 Acres @ $I,OIO.00/Acre = $29,330.00 Sanitary Sewer - 29.04 Acres @ $I.365.00/Acre = $39.640.00 Total 29.04 Acres @ $2,315.00/Acre = $68,970.00 Connection Fees are currently $1,310.00 for water and $795.00 for sanitary sewers per single- family residence. It is assumed that this development will be a single-family residential development. Connection Fees are paid when the infrastructure has been completed, satisfactory utility test results obtained and the subdivision has been released for permits. Water and Sanitary Sewer Connection Fees are paid on a ner-Iot basis. · If an irrigation system Is planned jor this development, addJtltJnal Water Connection Fees wlll be assessed based upon the recommendation of the Director ofCarme/ Utilities. If a community clllbhouse and/or swimming pool are plarmed lor the development, additional Water and Sanitary Sewer Connection Fees wi/I be tl$sessed based upon the recommendation of the Director of Carmel Utilities. 12. Is the existing single- family residence, located within the outlot, currently connected to City of Carmel water mains and sanitary sewer mains? COMMENTS - CONSTRUCTION PLANS 13. Please confirm with City Utilities that sanitary under the wet bottom pond is acceptable (run 403- 402). 14. Please add detail for City standard multi-use path to Sheet C80 1. 15. The right-of-way of 146m Street does not meet the requirements of the City's 20-Year Thoroughfare Plan. 16. Please add the City's minimum cover note to Sheets C201-C204. u u 17. Please indicate construction of lo-foot multi-use path across frontage of l46lb Street, 1 foot off of proposed right-of-way. Connect path to existing path at limits of frontage. 18. Curb joint detail on C801 shall be revised to 50' maximum spacing for expansion joints and 10' maximum spacing on contraction joints. Also revise note 7 on CIOl and Cl02. 19. Please add a structure on the pipe run 621-618 to allow a perpendicular pipe crossing out of structure 6 I 9. 20. Notes 6 and 8 on ClOI and CI02 need to be revised to reference DetailIO/C80!. 2 1. Please revise "granular backfill" reference in legend on sheets C40 l-C404 and C601-C605 to reference appropriate trench and bedding details on C802. 22. Contact Amanda Foley, City of Cannel Storm Water Administrator, regarding the storm water quality systems, erosion and sediment control practices, and bonding requirements for these items. 23. The City defers to the County for approval of the following: auxiliary lane lengths and widths, right-of-way pavement section within 146lb Street right-of-way (City agrees to the section indicated., but more substantial section may be required), and curb return radii, and creation of the valley gutter in the auxiliary lanes (City does not recommend creating valley gutters in auxiliary lanes because ofbydroplaning potential). 24. Section A-A does not appear to be correct. 25. Please add the City curbing policy to a sheet in the set. 26. Please revise detail12/C801 to not allow asphalt. All drives sball be concrete. 27. Detaill/C801 does not meet City standard as it relates to subsurface drain location under curb. Please remove the subsurface drain from this detail. 28. Please revise the "Streets" specification on C90l to conform to the City paving specifications and the curbing specifications to be added. 29. Is detention for the fully developed right-of-way of 146111 Street provided in the detention ponds? 30. Board of Public Works and Safety approval is required for each curb cut ofa public street for the private driveway. Portion of driveway within right-of-way of public street shall be concrete meeting requirements ofdetailI2/C80!. Walk across these areas shall be 6" concrete in accordance with detail IO/C80I. 3 I. Can pipe run 640-641 be directed to structure 645. It is Jess pipe and will not cross pavement and not be at the angle indicated. 32. Relocation of power poles, if required across the 146tb Street frontage to accommodate the improvements, shaUbe the sole responsibility of the developer and shall be located to the back edge of the right-of..;way as directed by the power company or the Department of Engineering or the County Highway Department. 33. The Department requires that the construction drawings be developed in accordance with the City of Cannel digital submission standards and that all required submittals for primary plat, secondary plat, and construction drawings be made. The digital files must be submitted to the Department of engineering prior to approval of the construction plans. 34. What is the flood route from the ponds across the adjacent property? 35. The plans lack the required drainage summary per the Stonn Water Technical Standards Manual. 36. Earthwork cannot commence until an approved stonn water management permit is issued. Such permit will not be issued until the fmal construction plans are approved. 37. The north arrow on D I 0 1 is in the wrong direction. 38. Revise note 5 on C70l and C702 to reference "TYPICAL WATER MAIN INSTALLATION' detail on C703. These comments represent the Department of Engineering's initial review ofllie construction plans for this project. We request that all responses to our comments be provided in writing. Failure to provide written responses may result in the delay of the review process. It is critical that our office be made aware of all modifications made on the plans being resubmitted, particularly if any such changes are considered "new" or fall outside of our previous reviews. Please provide revised plans including all revisions. Please notify us of any changes and specifically state any changes, including changes resulting from Plan Commission, BZA or other committee meetings. u u All bonds and performance guarantees must be posted prior to Engineering Department approval of construction plans. Also, Board of Public Works and Safety approvals and any other governing agency approvals (if required) must be obtained prior to Engineering Department approval. The Department reserves the right to provide additional comments based on subsequent reviews. If you have questions, please call me at 571-2441. cc: Matt Griffin, Department of Community Services John Duffy, Carmel Utilities Paul Pace, Carmel Utilities Paul Arnone, Cannel Utilities Greg Ilko, Crossroad Engineers Drees Homes Project File Engineering Department Review S:\DHILL\PROJREV06\ST AFFORDLANECONST C:umd Clay School, TJ\C C01llmU~.17.06 u 11 :~O 3.m. Docket No. 06100006 TAC: Carmel Science and Tech Park ~ Block 11 Construction Plans The applicant seeks to construct site infrastructure. The site is located at the SE corner of 122nd Street and Carmel Drive and is zoned M3. Filed by Robert Doster of Schneider Engineering for REI Real Estate. CCS: No comment. 11 :4~ H.m. Docket No. 06100007 SP: Stafford Lane Subdivision Secondary Plat The applicLillt seeks approval to plat 50 lots on 29.04 acres. The site is located at 4235 East 146lh Street and is zoned S 1. Filed by Eric Batt of Schneider Engineering, Inc. for The Drees Company. CCS: No comment. 12:00 p.m. Docket No. 06100008 TAC: Methodist Medical Plaza Parking Expansion The applicant seeks to expand parking lot into previously approved banked parking area. The site is located at 201 Pennsylvania Parkway and is zoned 85. Filed by Bill Butz of American Consulting for HCPI Indiana LLC. CCS : No conunenL 12'1~ P m Docket No. 06100009 TAC: Police Maintenance Department Expansion The applicant seeks to construct the Carmel Police Maintenance Depa.t1ment addition at the existing Cannel Street Department Maintenance facility. The site is located at 3562 West 131 ,t Street and is zoned S I. Filed by Karen Colli ns of Cripe Engineering for the Carmel Police Depm1ment CCS: No comment. 12.1fl p.m. Docket No. 06080004 Z and 06080005 ADLS: Global Financial Consultants The applicant seeks rezoning construction approval for a proposed office building and related parking. The site is cun-ently zoned S 1, with a request (0 rezone to the B2 c1assitication. The site is located at 3745 West 98th Street. Filed by Robert Clutter of Clark Quinn Moses Scott and Grahn, LLP for Global Financial Consultants. CCS: No comment. 10/03/2005 18:04 3177769~28 U PAGE 01/02 ~ Xmtan C 'Ward, Sm'P9'(lt 'Tli"m; (3 T7 ) 776'~'4~JS 'T-ax (V1) ?'7L'-~6:!.$ Slull' 1 SS Olle }(rll7tiltrm Cmmryl SI/iI/7n' ~A:"ML'_wilk, Indiana 4l;O(;(l-.z:'30 October 2. 2006 The Schneider Corporation ATTN: Eric Batt 8901 Otl$ Avenue Indianapolis, IN 46216.1.037 VIA F ACSllvfILE: 826-7200 :::;;J "", .f~S i ;: ltt 'l~1J --, . :i;, ....<llI \ -~" .oOf) ~ \" (.oS -. ~ >< - I- .: RE: Stafford Lane Dear Mr. Batt: We have reviewed the construction plans submitted to the Hamilton County Surveyor)s Office on September 7,2006, for this project and have the following comments; 1. The proposed project falls in the incorporated area and MS4 jurisdiction of the City ofCarmc1 2. The proposed project DOES fall in a Caunel Wellhead Protection Zone. 3. The proposed project is located in the U .G. Mitchner Regulated Drain Watershed. 4. Please submit an indirect outlet pennit (2 outlets), for the discharge into the V,G, Mitchner Regulated Drain, to this office. The application is available on our website at http://www.co.hamilton.in.us. go to Departments, Surveyor, and Forms. 5. Hamilton County Ordinance 4-26-99-C(5) requires downstream improvements including but not limited to: extending storm sewers, clearing, dredging, and/or removal of obstructions to open drains or natural water courses. It also required the down stream owner to be notified and they must consent in writing or they have the right to appeal any approval of the design. In this case you need to notify the 4 downstream property owners (6 Parc~ls) between this proposed project and the D.G. Mitchner Regulated Drain. Proof of the notification must be submitted to HCSQ, ~ 10/03/2005 18:04 3177759~28 U HAMILTON CO SURVEYOR U PAGE 02/02 6. HCSO would recommend analysis of the existing culvert under Gray Road to make: sure capacity ~;xist in this culvert without ovatopping of the roadway. 7. please contact the City of Carmel Engineering Department in reg$l'ds to required easement around detention basins. 8, Please show emergency spiUway and overflow routing for both detentilm ponds. 9. It appears that Str. 608 and 656 are both eod section with invert elevation lower then the 100 year elevatiQn of the ponds. This would cause these stn1ctures to surcharge during the 100 year event and exceed the allowable release rate for the site. It would also cause runoff10 flow onto adjacent property~ where it could cause damage to other homes or property. PleaSe revise this dc:Sign. 10. The capacity ofthe existing structure in Wedgewood will need to be verified in the drainage caleulations before t.he outlet can be ruled acceptable. 11. Please direct all other storm sewer questions to the City of Cannel Engineering Department or their consultant, Crossroad Engineers 12. Please pote that further comments may be necessary at a later date. Should you have any questions, r can be reached at 317-776-8495. Sincerely, ~,~ Plan Reviewer CC: Matt Griffm - Cannel DOCD Amanda Foley - Cannel Engineering Dick Hill- Cannel Engineering Joel !hunnan-HCHD Greg Ilko . Crossroad Engineers John Talbot. Drees U ~t~t!:~~~~li U Olo I DODD :1 .sf C&JrJrne! '$:~:i~~:Un'~~~lll~tmellat :~~ ;" _, c", ,~~ -- - . ,_ j ~:'Q;l~,~';fi~j~~;b CaR"JrulLd:)~~~dTiiliii~1iI16i[)32 \""" ~ ~""';fi,,1 i,-:,,,~,..-,'t.",,, ' ;';'-, j' ;,~. September 12, 2006 Eric W. Batt, PE The Schneider Corporation 8901 Otis Avenue Indianapolis, IN 46216-1037 RE: Stafford Lane - Secondary Plat & Construction Plans TSC 5622.001 Dear Mr. Batt: The information for the above-mentioned project has been received and reviewed. At the present time, I see nothing in the plans that would hamper law enforcement efforts. If we can be of any further assistance to you, please contact us. Resp, e91~JY' ____ 4~ Timothy J. Green Acting Chief of Police T JG:vb cc: Dept. of Community Services ft \\t.ct\\!E\) nt-? \ 3 1\)Q~ \)GCS j 3Jm571-2f>OO A Nationally Accredit 'forcement Agency E.x (3117~ 57J-2512 ~.., Schneider INDIANA Corporate Headquarters Historic Fort Harrison 8901 Otis Avenue Indianapolis, IN 46216 Phone: 31.7 .826.7100 Toll-Free: 866.973.7100 Fax: 317.826.7200 Lafayette Office 3725 Rome Drive Park 26 Lafilyette, IN 47905 Phone: 765.448.6661 Fax: 765.448.6665 Cannel Office 12821 E New Market Street Suite 100 Carmel. IN 46032 Phone: 317 _569.8112 Fax: 317.826.6410. Avon Office Building 1000 5250 E US Highway 36 Suite 250 Avon, IN 46123 Phone: 317.745.9926 Fax' 317.745.9973 Merrillville Office 9800 Connecticut Drive Suite 81.508 Merrillville, IN 46307 Phone: 219.644.3692 Fax: 219.644.3682 NORTH CAROLINA Charlotte Office 2151 Hawkins Street Suite 201 Charlotte. NC 28203 Phone: 704.333.8360 Fax: 704.333.8362 IOWA ProMap Office 1531 Airport Road SUite 2 Ames, IA 50010 Phone: 515.233.3311 Fax: 515.233.4575 u u The Schneider Corporation Historic Fort Harrison 8901 otis Avenue Indianapolis, IN 46216-1037 Phone: 317 .826. 7100 Fax: 317.826.7200 September 6, 2006 Postmaster c/o Cindy Klaiber Carmel Post Office United States Postal Service 275 Medical Drive Carmel, IN 46032-9998 RE: Stafford lane - Primary Plat TSC 5622.001 Dear Ms Klaiber: A copy of the Secondary Plat for the referenced project is enclosed. Our understanding is that the plat will be reviewed at the September 20, 2006 Carmel Technical Advisory Committee (TAC) meeting. Please review the plat and return any comments to us you may have. Should you have any questions please call us. Sincerely ELJJ~ Eric W. Batt, PE Project Manager cc: Matt Griffin - Carmel Department of Community Services EWB: cct Enclosure K ~'~e"E.~;lt"'J"- ~. \0 \OOL-L\IJV j \00 - -..x - . oc ~~ Schneider INDIANA Corporate Headquarters Historic Fort Harrison 8901 Otis Avenue Indianapolis, IN 46216 Phone: 317 .826. 7100 Toll-Free; 866.973.7100 Fax: 317.826.7200 Lafayette Office 3725 Rome Drive Pa rk 26 Lafayette, IN 47905 Phone: 765.448.6661 Fax: 765.448.6665 Carmel Office 12821 E New Market Street Suite 100 Carmel, IN 46032 Phone: 317.569.8112 Fax: 31.7.826.6410 Avon Office Building 1000 5250 E US Highway 36 Suite 250 Avon. IN 46123 Phone: 317.745.9926 Fax: 317.745.9973 Merrillville Office 9800 Connecticut Drive Suite 81-508 Merrillville, IN 46307 Phone: 219.644.3692 Fax: 219.644.3682 NORTH CAROLINA Charlotte Office 2151 Hawkins Street Suite 201 Charlotte, NC 28203 Phone: 704.333.8360 Fax: 704.333.8362 IOWA ProMap Office 1531 Airport Road Suite 2 Ames, IA 50010 Phone: 515.233.3311 Fax: 515.233.4575 u u The Schneider Corporation Historic Fort Harrison 8901 Otis Avenue Indianapolis, IN 46216.1037 Phone: 317.826.7100 Fax: 317.826.7200 September 6,2006 Gary Duncan Carmel Engineering One Civic Square Carmel, IN 46032 RE: Stafford Lane - Primary Plat TSC 5622,001 Dear Gary: A copy of the Secondary Plat, construction plans, and storm drainage report for the referenced project is enclosed. Our understanding is that this information will be reviewed at the September 20,2006 Carmel Technical Advisory Committee (TAC) meeting. Please review the information and return any comments to us you may have. Should you have any questions please call us. Sincerely ~JJ~ Eric W. Batt, PE Project Manager cc: Matt Griffin - Carmel Department of Community Services EWB: cct Enclosure B'\5~~flZ~~~~P.l~~~lf . ' _ L ~. ~ . I-~ .i.!.. oil lillli.~ ~~ Schneider INDIANA Corporate Headquarters Historic Fort Harrison 8901 Otis Avenue Indianapolis, IN 46216 Phone: 317.826.7100 Toll-Free: 866.9.73.7100 Fax: 317.826.7200 Lafayette Office 3725 Rome Drive Park 26 Lafayette, IN 47905 Phone: 765.448.6661 Fax: 765.448.6665 Cannel Office 12821 E New Market Street Suite 100 Carmel, IN 46032 Phone: 317.569.8112 Fax: 317.826.6410 Avon Office Building 1000 5250 E US HigllWay 36 Suile 250 Avon, IN 46123 Phone: 317.745.9926 Fax: 317.745.9973 Merrillville Office 9800 Connecticut Drive Suite B1508 Merrillville, IN 46307 PllDne: 219.644.3692 Fax: 219.644.3682 NORTH CAROLINA Charlotte Office 2151 Hawkins Street Suite 201 Charlotte. NC 28203 Phone: 704.333.8360 Fax: 704.333.8362 IOWA ProMap Office 1531 Airport Road Su ite 2 Ames, IA 50010 Phone: 515.233.3311 Fax: 515.233.4575 u u The Schneider Corporation Historic Fort Harrison 8901 Otis Avenue Indianapolis, IN 46216.1037 Phone: 317.826.7100 Fax: 317.826.7200 September 6, 2006 Gregory IIko, PE Crossroads Engineering 3417 South Sherman Drive Beech Grove, IN 46107 RE: Stafford Lane - Primary Plat TSC 5622.001 Dear Gregory: A copy of the Secondary Plat, construction plans, and storm drainage report for the referenced project is enclosed. Our understanding is that this information will be reviewed at the September 20,2006 Carmel Technical Advisory Committee (TAG) meeting. Please review the information and return any comments to us you may have. Should you have any questions please call us. Sincerely [ LJj~ Eric W. Batt, PE Project Manager cc: Matt Griffin - Carmel Department of Community Services Gary Duncan - Carmel Engineering EWB: eet Enclosure ~'~"~.Rll.~j'.~"II"" t"C\,JK\,jo2~\uu nrn:R':S ' - - . oc ~~ Schneider INDIANA Corporate Headquarters Historic Fort Harrison 8901 OtiS Avenue Indianapolis, IN 46216 Phone: 3:1.7 -826. 71.00 Toll-Free: 866.973.7100 Fax: 317.826.7200 Lafayette Office 3725 Rome Drive Park 26 Lafayette, IN 47905 Phone: 765.448.6661 Fax: 765.448.6665 Carmel Office 12821 E New Market Street Suite 100 Carmel, IN 46032 Phone: 317.569.8112 Fax: 317.826.6410 Avon Office Building 1000 5250 E US Highway 36 Suite 250 Avon, IN 46123 Phone: 317.745.9926 Fax: 317.745.9973 Merrillville Office 9800 Connecticut Drive Suite 81-508 Merrillville. IN 46307 Phone: 219.644.3692 Fax: 219.644.3682 NORTH CAROLINA Charlotte Office 2151 Hawkins Street SUite 201 Charlotte. NC 28203 Phone: 704.333.8360 Fax: 704.333.8362 IOWA ProMap Office 1531 Airport Road Suite 2 Ames, IA 50010 Phone: 515.233.3311 Fax: 515.233.4575 u u The Schneider Corporation Historic Fort Harrison 8901 otis Avenue Indianapolis, IN 46216-1037 Phone: 317.826.7100 Fax: 317.826.7200 September 6, 2006 Greg Hayes Hamilton County Surveyor's Office One Hamilton County Square, Suite 188 Hamilton County Judicial Center Noblesville IN 46060 RE: Stafford Lane - Primary Plat TSC 5622.001 Dear Gregory: A copy of the Secondary Plat, construction plans, and storm drainage report for the referenced project is enclosed. Our understanding is that this information will be reviewed at the September 20,2006 Carmel Technical Advisory Committee (TAG) meeting. Please review the information and return any comments to us you may have. Should you have any questions please call us. Sincerely EJJ~ Eric W. Batt, PE Project Manager cc: Matt Griffin - Carmel Department of Community Services Gary Duncan - Carmel Engineering EWB: eet Enclosure _'~l!"~.~"w."..''''rm K.'~K'jttL"::'VU "DUGS ". - . ac ~~ Schneider INDIANA Corporate Headquarters Historic Fort Harrison 8901 Otis Avenue Indianapolis. IN 46216 P11Qne: 317.826.7100 Toll-Free: 866.973. noo Fax: 317.826.7200 Lafayette Office 3"f25 Rome Drive Park 26 Lafayette. IN 47905 Phone: 765.448.6661 Fax: 765.448.6665 Carmel Office 12821 E New Market Street Su ite 100 Cannel, IN 46032 Phone: 317.569.8112 Fax: 317.826.6410 Avon Office Building 1000 5250 E US Highway 36 Suite 2GO Avon. IN 46123 Phone: 317,145.9926 Fax: 317.745.9973 Merrillyille Office 9800 Connecticut Drive Suite Bl-508 Merrillville, IN 46307 Phone: 219.644.3692 Fax; 219.644.3682 NORTH CAROLINA Charlotte Office 2151 Hawkins Street Suite 201 Charlotte, NC 28203 Phone: 704.333.8360 Fax: 704.333.8362 IOWA ProMap Office 1531 Airport Road SUite 2 Ames. IA 50010 Phone: 515.233.3311 Fax: 515.233.4575 u u The Schneider Corporation Historic Fort Harrison 8901 Otis Avenue Indianapolis. IN 46216-1037 Phone: 317.826.7100 Fax: 317.826.7200 September 6, 2006 Bill Akers Carmel/Clay Communications 31 First Avenue NW Carmel, IN 46032 RE: Stafford lane - Secondary Plat & Construction Plans TSC 5622.001 Dear Bill: A copy of the Secondary Plat and construction plans for the referenced project is enclosed. Our understanding is that this information will be reviewed at the September 20,2006 Carmel Technical Advisory Committee (TAC) meeting. Please review the information and return any comments to us you may have. Should you have any questions please call us. Sincerely ~JJ~ Eric W. Batt, PE Project Manager cc: Matt Griffin - Carmel Department of Community Services EWB: eet Enclosure I .\OK\OtJLL\IJU l\ao_~\''tWC''rOOV~J~ ~~ Schneider INDIANA Corporate Headquarters Historic Fort Harrison 8901 Otis Avenue Indianapolis, IN 46216 Phone: 317.826.7100 Toll-Free: 866.973.7100 Fax: 317,826.7200 Lafayette Office 3725 Rome Drive Park 26 Lafayette, IN 47905 Phone: 765.448.6661 Fax: 765.448.6665 Cannel Office 12821 E New Market Street Suite 100 Carmel, IN 46032 Phone: 317.569.8112 Fax:' 317.826.6410 Avon Office Building 1000 5250 E US Highway 36 Suite 250 Avon. IN 46123 Phone: 317.745.9926 Fax: 317.745.9973 Merrillville Office 9800 Connecticut Drive Swte Bl-508 Merrillville, IN 46307 Phone: 219.644.3692 Fax: 21.9.644.3682 NORTH CAROLINA Charlotte Office 2151. Hawkins Street Suite 201 Charlotte. NC 28203 Phone: 704.333.8360 Fax: 704.333.8362 IOWA ProMap Office 1531 Airport Road Suite 2 Ames. IA 50010 Phone: 515.233.3311 Fax: 515.233.4575 u u The Schneider Corporation Historic Fort Harrison 8901 Otis Avenue Indianapolis. IN 46216-1037 Phone: 317.826.7100 Fax: 317.826.7200 September 6,2006 Bill Hohlt Deputy Building Commissioner One Civic Square Carmel, IN 46032 RE: Stafford Lane ~ Secondary Plat & Construction Plans TSC 5622.001 Dear Bill: A copy of the Secondary Plat and construction plans for the referenced project is enclosed. Our understanding is that this information will be reviewed at the September 20,2006 Carmel Technical Advisory Committee (TAC) meeting. Please review the information and return any comments to us you may have. Should you have any questions please call us. Sincerely EG~ Eric W. Batt, PE Project Manager cc: Matt Griffin - Carmel Department of Community Services EWB: cct Enclosure JJlW~~~~t~~M~"W!!M"""""- 1.\::>11..\::>0"""'\ - - tj . oc ~~ Schneider INDIANA Corporate Headquarters Historic Fort Hamson 8901 Otis Avenue Indianapolis, IN 46216 PllOne: 317.826.7100 Toll-Free: 866.973.7100 Fax: 31.7 .826.7200 Lafayette Office 3725 Rome Drive Park 26 Lafayette. IN 47905 Phone: 765.448.6661 Fax: 765.448.6665 Carmel Office 12821 E New Market Street Suite 100 Carmel, IN 46032 Phone: 317.569.81.12 Fax: 317.826.6410 Avon Office 8uilding 1000 5250 E US Highway 36 Suite 250 Avon, IN 46123 Phone: 317.745.9926 Fax: 317.745.9973 Merrillville Office 9800 Connecticut Drive Suite 81-508 Merrillville. IN 46307 Phone: 219.644.3692 Fax: 219.644.3682 NORTH CAROLINA Charlotte Office 2151 Hawkins Street SUite 201 Charlotte. NC 28203 Phone: 704.333.8360 Fax: 704.333.8362 IOWA ProMap Office 1531 Airport Road Suite 2 Ames. IA 50010 Phone: 515.233.3311 Fax: 515.233.4575 u u The Schneider Corporation Historic Fort Harrison 8901 Otis Avenue Indianapolis, IN 46216-1037 Phone: 317.826.7100 Fax: 317.826.7200 September 6, 2006 Chuck Shupperd Vectren Energy PO Box 1700 Noblesville IN 46061-1700 RE: Stafford Lane - Secondary Plat & Construction Plans TSC 5622.001 Dear Chuck: A copy of the Secondary Plat and construction plans for the referenced project is enclosed. Our understanding is that this information will be reviewed at the September 20,2006 Carmel Technical Advisory Committee (TAC) meeting. Please review the information and return any comments to us you may have. Should you have any questions please call us. Sincerely E0J~ Eric W. Batt, PE Project Manager cc: Matt Griffin - Carmel Department of Community Services EWB: ect Enclosure I .\~~ll.WU~ j\U6~~',')ll!"ra~~~~ol""~ ~.., Schneider INDIANA Corporate Headquarters Historic Fort Harrison 8901 Otis Avenue Indianapolis. IN 46216 Phone: 317.826.7100 Toll-Free: 866.973.7100 Fax: 317.826.7200 Lafayette Office 3725 Rome Drive Park 26 Lafayette, IN 47905 Phone: 765.448.6661 Fax: 765.448.6665 Carmel Office 12821 E New Market Street Suite 100 Carmel, IN 46032 Phone: 317.569.8112 Fax: 317.826.6410 Avon Office Building 1000 5250 E US Highway 36 Suite 250 Avon. IN 46123 Phone: 317.745.9926 Fax: 317.745.9973 Merrillville Office 9800 Connecticut Drive Suite 81.508 Merrillville, IN 46307 Phone: 219.644.3692 Fax: 219.644.3682 NORTH CAROLINA Charlotte Office 2151 Hawkins Street Suite 201 Cllarlolte, NC 28203 Pt1One: 704.333.8360 Fax: 704.333.8362 IOWA ProMap Office 1531 Airport Road Suite 2 Ames. IA 50010 Phone: 515,233.3311 Fax: 515.233.4575 u u The Sch neider Corporation Historic Fort Harrison 8901 Otis Avenue Indianapolis. IN 46216-1037 Phone:317.826.7100 Fax: 317.826.7200 September 6, 2006 Dave Klingensmith Carmel Street Dept 3400 W. 131st Street Westfield, IN 46074 RE: Stafford Lane - Secondary Plat & Construction Plans TSC 5622.001 Dear Dave: A copy of the Secondary Plat and construction plans for the referenced project is enclosed. Our understanding is that this information will be reviewed at the September 20, 2006 Carmel Technical Advisory Committee (T AC) meeting. Please review the information and return any comments to us you may have. Should you have any questions please call us. Sincerely EJj~ Eric W. Batt, PE Project Manager cc: Matt Griffin - Carmel Department of Community Services EWB: cct Enclosure ~bt)~~\uu.IU'~"i~TI<Wj(ttrRI~~~r''''~ ~~ Schneider INDIANA Corporate Headquarters Historic Fort Harrison 8901 Otis Avenue Indianapolis, IN 46216 PllOne: 317,826.7100 Toll.Free: 866_973.7100 Fax: 317_826_7200 Lafayette Office 3725 Rome Drive Park 26 Lafayette, IN 47905 Phone: 765.448,6661 Fax; 765.448.6665 Carmel Office 12821 E New Market Street Suite 100 Carmel, IN 46032 Phone: 317.569_8112 Fax: 317,826.6410 A yon Office Building 1000 5250 E US Highway 36 Suite 250 Avon, IN 46123 Phone: 317.745.9926 Fax: 317_745_9973 Merrillville Office 9800 Connecticut Drive Suite 81.508 MRrrillville, iN 46307 Phone: 219_644_3692 Fax: 219_644_3682 NORTH CAROLINA Charlotte Office 2151 Hawkins Street Suite 201 Charlotte, NC 28203 Phone: 704_333,8360 Fax: 704.333.8362 IOWA ProMap Office 1531 Airport Road Suite 2 Ames, IA 50010 Phone: 515.233_3311 Fax: 515_233.4575 u u The Schneider Corporation Histone Fort Hamson 8901 Otis Avenue Indianapolis, IN 46216-1037 Phone: 317.826_7100 Fi'lx: 317_826.7200 September 6, 2006 Gary Hoyt Office of Fire Chief, Fire Station #1 Two Civic Square Carmel, IN 46032 RE: Stafford Lane - Secondary Plat & Construction Plans TSC 5622.001 Dear Gary: A copy of the Secondary Plat and construction plans for the referenced project is enclosed. Our understanding is that this information will be reviewed at the September 20,2006 Carmel Technical Advisory Committee (TAG) meeting. Please review the information and return any comments to us you may have. Should you have any questions please call us. Sincerely EG~ Eric W. Batt, PE Project Manager cc: Matt Griffin - Carmel Department of Community Services EWB: cct Enclosure _!~!ifr&~f~W~~ : oes rans- e - ax _ 00 '-~ Schneider INDIANA Corporate Headquarters Historic Fort Harrison 8901 otiS Avenue Indianapolis, IN 46216 PrlOne: 317.826.7100 Toll-Free: 866.973.7100 Fax: 317.826.7200 Lafayette Office 3725 Rome Drive Park 26 Lafayette. IN 47905 Phone: 765.448.6661 Fax: 765.448.6665 Carmel Office 12821 E New Market Street Suite 100 Carmel, IN 46032 Phone: 317.569.8112 Fax: 317.826.6410 Avon Office Building 1000 5250 E US Highway 36 Suite 250 Avoll. IN 46123 PllOne: 317.745.9926 Fax: 317.745.9973 Merrillville Office 9800 Connecticut Drive Suite Bl-508 Merriliville. IN 46307 Phone: 219.644.3692 Fax: 219.644.3682 NORTH CAROLINA Charlotte Office 2151 Hawkins Street Suite 201 Ch~rlotte, NC 28203 Phone: 704.333.8360 Fax: 704.333.8362 IOWA ProMap Office 1531 Airport Road Suite 2 Ames. IA 50010 Phone: 515.233.3311 i'ax: 515233.4575 u u The Schneider Corporation HistoriC Fort Harrison 8901 otis Avenue Indianapolis. IN 46216.1037 Prlone: 317.826.7100 Fax: 317 .826. 7200 September 6, 2006 Jason Kirkman Brighthouse Networks 3030 Roosevelt Avenue Indianapolis, IN 46218 RE: Stafford Lane - Secondary Plat & Construction Plans TSC 5622.001 Dear Jason: A copy of the Secondary Plat and construction plans for the referenced project is enclosed. Our understanding is that this information will be reviewed at the September 20, 2006 Carmel Technical Advisory Committee (TAC) meeting. Please review the information and return any comments to us you may have. Should you have any questions please call us. Sincerely EG~ Eric W. Batt, PE Project Manager cc: Matt Griffin - Carmel Department of Community Services EWB: cct Enclosure II: ,.~("It~r_~~,J{oI.mm I .\ 56~<:\uu - e - ax I . OC ~~ Schneider INDIANA Corporate Headquarters Historic Fort Harrison 8901 Otis Avenue Indianapolis. IN 46216 PllOne; 317.826.7100 Toll-Free: 866.973.7100 Fax: 317.826.7200 Lafayette Office 3725 Rome Drive Park 26 Lafayette. IN 47905 Phone: 765.448.6661 Fax: 765.448.6665 Carmel Office 12821 E New Market Street Suite 100 Carmel. IN 46032 Phone: 317.569.8112 Fax: 317826.6410 Avon Office Building 1000 5250 E US Highway 36 Suile 250 Avon. IN 46123 Phone: 317.745.9926 Fax: 317.745.9973 Merrillville Office 9800 Connecticut Drive Suite Bl-508 Merrillville, IN 46307 Phone: 219.6443692 Fax: 219.644.3682 NORTH CAROUNA Charlotte Office 2151 Hawkins Street Suite 201 Charlotte, NC 28203 Phone: 704.333.8360 Fax: 704.333.8362 IOWA ProMap Office 1531 Airport Road Suite 2 Ames. IA 50010 Phone: 515.233.3311 Fax: 515.233.4575 u u The Schneider Corporation Historic Fort Harrison 8901 otis Avenue Indianapolis. IN 46216-1037 Phone: 317.826.7100 Fax: 317.826.7200 September 6, 2006 Jason LeMaster Hamilton County Health Dept. One Hamilton Square, Ste. 30 Noblesville, IN 46060 RE: Stafford Lane - Secondary Plat & Construction Plans TSC 5622.001 Dear Jason: A copy of the Secondary Plat and construction plans for the referenced project is enclosed. Our understanding is that this information will be reviewed at the September 20, 2006 Carmel Technical Advisory Committee (TAC) meeting. Please review the information and return any comments to us you may have. Should you have any questions please call us. Sincerely E tJJ~ Eric W. Batt, PE Project Manager cc: Matt Griffin - Carmel Department of Community Services EWB: cet Enclosure I .'~K\boL.!.\UU .~~~i~lJrmdae~d~~~UIIB41 ~~ Schneider INDIANA Corporate Headquarters Historic Fort Harrison 8901 OtiS Avenue Indianapolis, IN 46216 Phone' 31.7.826.7100 Toll-Free: 866.973.7100 Fa~: 317.826.7200 Lafayette Office 3725 Rome Drive Park 26 Lafayette, IN 47905 Phone: 765.448.6661 Fax: 765.448.6665 Carmel Office 12821 E New Market Slreet SuitB 100 Carmel, IN 46032 Phone: 317.569.8112 Fax: 317.826.6410 Avon Office Building 1000 5250 E US Highway 36 Suite 250 Avon, IN 46123 PhonB: 317.745.9926 Fax: 31.7.745.9973 Merrillville Office 9800 ConnBcticut Drive 5uitB 81.508 Merrillville, IN 46307 Phone: 219.644.3692 Fax: 219.644.3682 NORTH CAROLINA Charlotte Office 2151 Hawkins Street SUite 201 Charlotte. NC 28203 Phone: 704.333.8360 Fa~: 704.333.8362 IOWA Pro Map Office 1531 Airport Road SUltB 2 AmBs. IA 50010 Phone: 515233.3311 Fax: 515.233.4575 u u The Schneider Corporation Historic Fort Harrison 8901 Otis Avenue IndianapOlis. IN 46216-1037 Phone: 317.826.7100 Fax: 317.826.7200 September 6, 2006 Jennifer Marlett Indianapolis Water Company 1220 Waterway Blvd. Indianapolis, IN 46206 RE: Stafford Lane - Secondary Plat & Construction Plans TSC 5622.001 Dear Jennifer: A copy of the Secondary Plat and construction plans for the referenced project is enclosed. Our understanding is that this information will be reviewed at the September 20, 2006 Carmel Technical Advisory Committee (TAC) meeting. Please review the information and return any comments to us you may have. Should you have any questions please call us. Sincerely tG~ Eric W. Batt, PE Project Manager cc: Matt Griffin - Carmel Department of Community Services EWB: cet Enclosure ~ .~"'~i!!l~I'](~'lllB<l'l : b,~\UU ~ ans--- ~ ~ ax J . OC ~~ Schneider INDIANA Corporate Headquarters Historic Fort Hamson 8901 otis Avenue Indianapolis, IN 46216 Phone: 317 .826.7100 Toll-Free: 866.973.7100 Fax: 317.826.7200 Lafayette Office 3725 Rome Drive Park 26 Lafayette, IN 47905 Phone: 765.448.6661 Fax: 765.448.6665 Carmel Office 12821 E New Market Street Suite 100 Carmel, IN 46032 Phone: 317.569.8112 Fax: 317.826,6410 Avon Office Building 1000 5250 E US Highway 36 Suite 250 Avon, IN 46123 Phone: 317.745.9926 Fax: 317.745.9973 Merrillville Office 9800 Connecticut Drive Suite 81.508 Merrillville, IN 46307 Phone: 219.644.3692 Fax: 219.644.3682 NORTH CAROUNA Charlotte Office 2151 Hawkins Street Suite 201 Charlotte. NC 28203 Phone: 704.333.8360 Fax: 704.333.8362 IOWA ProMap Office 1531 Airport Road Suite 2 Ames, IA 50010 Phone: 515233.3311 Fax: 515.233.4575 u u The Schneider Corporation Historic Fort Harrison 8901 Otis Avenue Indianapolis, IN 46216-1037 Phone: 317.826.7100 Fax: 317.826.7200 September 6, 2006 Joel Thurman Hamilton County Highway Department 1700 S. 10th Street Noblesville, IN 46060 RE: Stafford Lane - Secondary Plat & Construction Plans TSC 5622.001 Dear Joel: A copy of the Secondary Plat and construction plans for the referenced project is enclosed. Our understanding is that this information will be reviewed at the September 20,2006 Carmel Technical Advisory Committee (TAC) meeting. Please review the information and return any comments to us you may have. Should you have any questions please call us. Sincerely EJJ~ Eric W. Batt, PE Project Manager cc: Matt Griffin - Carmel Department of Community Services EWB: cct Enclosure ~ .~Fr~I~~tl~n*~"f_~I'){"'J"",," :\\:JtJ'::L\UtJ ocs . rans- e ~ ax _ oc ~~ Schneider INDIANA Corporate Headquarters Historic Fort Hamson 8901 Otis Avenue Indianapolis, IN 46216 Phone: 31.7.826.7100 TolI.Free: 866.973.7100 Fax: 317.826.7200 Lafayette Office 3725 Rome Drive Park 26 Lafayette. IN 47905 Phone: 765.448.6661 Fax: 765.448.6665 Carmel Office 12821 E New Market Street Suite 100 Carmel, IN 46032 Phone: 317.569.8112 Fax: 317.826.6410 Avon Office Building 1000 5250 E US Highway 36 Suite 250 Avon. IN 46123 Phone: 317.745.9926 Fax: 317.745.9973 Merrillville Office 9800 Connecticut Drive Suite Bl.508 Merrillville. IN 46307 Phone: 219.644.3692 Fax: 219.644.3682 NORTH CAROLINA Charlotte Office 2151 Hawkins Street Suite 201 Charlotte, NC 28203 Phone: 704.333.8360 Fax: 704.333.8362 IOWA ProMap Office 1531 Airport Road Suite 2 Ames, IA 50010 Phone: 515.233.3311 Fax: 515.233.4575 u u The Schneider Corporation Historic Fort Harrison 8901 otis Avenue Indianapolis, IN 46216-1037 Phone: 317.826.7100 Fax: 317.826.7200 September 6, 2006 John Duffy Carmel Clay Utilities 760 Third Ave SW Carmel, IN 46032 RE: Stafford Lane - Secondary Plat & Construction Plans TSC 5622.001 Dear John: A copy of the Secondary Plat and construction plans for the referenced project is enclosed. Our understanding is that this information will be reviewed at the September 20, 2006 Carmel Technical Advisory Committee (TAC) meeting: Please review the information and return any comments to us you may have. Should you have any questions please call us. Sincerely [~{!;m Eric W. Batt, PE Project Manager cc: Matt Griffin - Carmel Department of Community Services EWB: cct Enclosure ,ilK .~~~.t3I'-~_~'r".{"""" : \:JO":::L\UUCS. rans- e' - a . OC ~~ Schneider INDIANA Corporate Headquarters Historic Fort Harrison 8901 Otis Avenue Indianapolis. IN 46216 Phone: 317.826.7100 Toll-Free: 866.973.7100 Fax: 317.826.7200 Lafayette Office 3725 Rome Drive Pa rk 26 Lafayette. IN 47905 Phone: 765.448.6661 Fax; 765.448.6665 Carmel Office 12821 E New Market Street Suite 100 Carmel. IN 46032 Pllone: 317.569.8112 Fax: 317.826.6410 Avon Office Building 1000 5250 E US Highway 36 Suite 250 Avon, IN 46123 Phone: 317.745.9926 Fax: 317.745.9973 Merrillville Office 9800 Connecticut Onve Suite 81-508 Merrillville, IN 46307 Phone: 219.644.3692 Fa~: 219.6443682 NORTH CAROUNA Charlotte Office 2151 Hawkins Street Suite 201 Charlotte. NC 28203 Phone: 704.333.8360 Fax: 704.333.8362 IOWA Pro Map Office 1531 Airport Road Suite 2 Ames, IA 50010 Phone: 515.233.331.1 Fax: 515.233.4575 u u The Schneider Corporation llistoric Fort Harrison 8901. Otis Avenue Indianapoli~, IN 46216-1037 Phone: 317.826. 7100 Fa~: 317.826.7200 September 6, 2006 Mark Westermeier Carmel/Clay Parks Department 760 Third Avenue SW, Ste. 100 Carmel IN 46032 RE: Stafford Lane - Secondary Plat & Construction Plans TSC 5622.001 Dear Mark: A copy of the Secondary Plat and construction plans for the referenced project is enclosed, Our understanding is that this information will be reviewed at the September 20,2006 Carmel Technical Advisory Committee (TAC) meeting, Please review the information and return any comments to us you may have. Should you have any questions please call us. Sincerely EJJ~ Eric W. Batt, PE Project Manager cc: Matt Griffin - Carmel Department of Community Services EWB: cct Enclosure o~"Pt:lM~~,(~~""""'" I ,l;)I\l,;)Otl:'::lU.UI\U .. ,.' I . '--~ Schneider INDIANA Corporate Headquarters Historic Fort Harrison 8901 OOs Avenue Indianapolis, IN 46216 Phone: 3:17.826.71.00 Toll-Free: 866.973.7100 Fax: 317 .826. 7200 Lafayette Office 3725 Home Drive Park 26 Lafayette. IN 47905 Phone: 765.448.6661 Fax: 765.448.6665 Carmel Office 12821 E New Market Street Suite 100 Carmel, IN 46032 Phone: 317.569.8112 Fax: 3.1.7.826.6410 Avon Office Building 1000 5250 E US Highway 36 Suite 250 Avon. IN 46123 Phone: 317.745.9926 Fax: 317.745.9973 Merrillville Office 9800 Connecticut Drive Suite Bl-508 Merrillville, IN 46307 Phone: 219.6443692 Fax: 219.644.3682 NORTH CAROLINA Charlotte Office 2151 Hawkins Street Suite 201 Charlotte, NC 28203 Phone: 704.3338360 Fax: 704.3:33.8362 IOWA ProMap Office 1531 Airport Road Suite 2 Ames. iA 50010 Phone: 515.233.3311 Fax: 51.5.233.4575 u u The Schneider Corporation Historic Fori Hamson 8901 Otis Avenue Indianapolis. IN 46216-10::17 Ph(lne: 317.826.7100 Fax: 317.826.7200 September 6, 2006 Matt Griffin Carmel Department of Community Services One Civic Square Carmel, IN 46032 RE: Stafford Lane - Secondary Plat & Construction Plans TSC 5622.001 Dear Matt: A copy of the Secondary Plat and construction plans for the referenced project is enclosed. Our understanding is that this information will be reviewed at the September 20,2006 Carmel Technical Advisory Committee (TAC) meeting Please review the information and return any comments to us you may have. Should you have any questions please call us. Sincerely E0J~ Eric W. Batt, PE Project Manager ce: Matt Griffin - Carmel Department of Community Services EWB: ect Enclosure ~~~~-~'~.J!~rM()~r'JI~.bt~ r'i . Des rans- e - ax\ . oc ~~ Schneider INDIANA Corporate Headquarters Historic Fort Harrison 8901 Otis Avenue Indianapolis, IN 46216 Phone: 31.7 .826. 7100 Toll-Free: 866.973.7100 Fax: 317.826.7200 Lafa yette Office 3725 Rome Drive Park 26 Lafayette. IN 47905 Phone: 765.448.6661 Fax: 765.448.6665 Carmel Office 12821 E New Market Street Suite 100 Carmel, IN 46032 Phone: 317.569.8112 Fax: 317.826.641.0 Avon Office Building 1000 5250 E US Highway 36 Suite 250 Avon. IN 46123 Phone: 317.745.9926 Fax: 317.745.9973 Merrillville Office 9800 Connecticut Drive Suite Bl.508 Merrillville, IN 46307 Phorle: 219.644.3692 Fax: 219.644.3682 NORTH CAROLINA Charlotte Office 2151. Hawkins Street Suite 201 Charlotte, NC 28203 Phone: 704.333.8360 Fax: 704.333.8362 IOWA ProMap Office 1531 Airport Road Suite 2 Ames. IA 50010 Phone: 515.233.3311 Fax: 515.233.4575 u u The Schneider Corporation Historic Fort Harrison 8901 Otis Avenue Irldianapolis, IN 46216-1037 Pll0ne: 317.826.7100 Fax: 317.826.7200 September 6, 2006 Michael Fogarty Office of Police Chief Three Civic Square Carmel, IN 46032 RE: Stafford Lane - Secondary Plat & Construction Plans TSC 5622.001 Dear Michael: A copy of the Secondary Plat and construction plans for the referenced project is enclosed. Our understanding is that this information will be reviewed at the September 20,2006 Carmel Technical Advisory Committee (TAC) meeting. Please review the information and return any comments to us you may have. Should you have any questions please call us. Sincerely EJJ~ Eric W. Batt, PE Project Manager cc: Matt Griffin - Carmel Department of Community Services EWB: eet Enclosure BJ u4~r;{~t_~:tJ{"""BWJ : LL\U Des rans- e - ax . OC i Ii ~~ Schneider INDIANA Corporate Headquarters Historic Fort Harrison 8901 OtiS .I\venue Indianapolis, IN 46216 Phone: 317.826.7100 Toll-Free: 866.973.7100 Fax: 317 .826.7200 Lafayette Office 3725 Rome Drive Park 26 Lafayette. IN 47905 Phone: 765.448.6661 Fax: 765.448.6665 Carmel Office 12821 E New Market Street Su ite 100 Carmel, IN 46032 Phone: 317.569.8112 Fax: 317.826.61110 Avon OHice Building 1000 5250 E US Highway 36 Suite 250 Avon. IN 46123 Phone: 317.745.9926 Fax: 317.745.9973 Merrillville OHice 9800 Connecticut Drive Suite Bl-508 Merrillville, IN 46307 Phone: 219.644.3692 Fax: 219.644.3682 NORTH CAROLINA Charlotte Office 2151 Hawkins Street Suite 201 Charlotte, NC 28203 Phone: 704.333.8360 Fax: 704.333.8362 IOWA ProMap Office 1531 Airport Road Suite 2 .I\mes, IA 50010 Phone: 515.233.3311 Fax: 515.233.4575 u u The Schneider Corporation Historic Fort Harrison 8901 Otis Avenue Indianapolis, IN 46216-1037 Phone: 317.826.7100 Fax: 317.826.7200 September 6, 2006 Ron Morris Indianapolis Power & Light Co. 3600 North Arlington Avenue Indianapolis, IN 46218 RE: Stafford Lane - Secondary Plat & Construction Plans TSC 5622.001 Dear Ron: A copy of the Secondary Plat and construction plans for the referenced project is enclosed. Our understanding is that this information will be reviewed at the September 20,2006 Carmel Technical Advisory Committee (TAC) meeting. Please review the information and return any comments to us you may have. Should you have any questions please call us. Sincerely E0J~ Eric W. Batt, PE Project Manager cc: Matt Griffin -Carmel Department of Community Services EWB: cet Enclosure ~ .~~~l:It'lt"m~d'''"'HI'''. : 5K\:lO"::"::\UO - e - x L . oc i I. ~~ Schneider INDIANA Corporate Headquarters Historic Fort Harrison 8901 Otis Avenue Indianapolis, IN 46216 Phone: 317,826,7100 Toll-Free: 866,973,7100 Fax: 317.826.7200 Lafayette Office 3725 Rome DrIVe Park 26 Lilfayetle. IN 4-;905 Phone: 765.448.6661 Fax: 765.448.6665 Carmel Office 12821E New Market Street Suite '1.00 Carmel, IN 46032 Phone: 317.569.8112 Fax: 317.826.6410 Avon office Building 1000 5250 E US Highway 36 Suite 250 Avon, IN 46'1.23 Phone: 3'l7.745.9926 Fax: 317.745.9973 MerriJlville Office 9800 Connecticut Drive Suite Bl-508 Mernllvllle, IN 46307 Phone: 219.644.3692 Fax: 219.644.3682 NORTH CAROLINA Charlotte Office 2151 H<lwkil1s Street Suite 201 Cllmlotte. NC 28203 Pllone: 704.333.8360 Fax: 704.333.8362 IOWA ProMap Office 1531 Airport Road Suite 2 Ames. IA 50010 Phone: 515.233.3311 Fax: 515.233.4575 LJ u The Schneider Corporation Historic Fort Harrison 8901 Otis Avenue Indianapolis, IN 46216-1037 Phone: 317.826.7100 Fax: 317.826.7200 September 6, 2006 Scott Brewer Carmel Department of Community Services One Civic Square Carmel, IN 46032 RE: Stafford Lane - Secondary Plat & Construction Plans TSC 5622.001 Dear Scott: A copy of the Secondary Plat and construction plans for the referenced project is enclosed. Our understanding is that this information will be reviewed at the September 20,2006 Carmel Technical Advisory Committee (TAC) meeting. Please review the information and return any comments to us you may have. Should you have any questions please call us. Sincerely E8~ Eric W. Batt, PE Project Manager cc: Matt Griffin - Carmel Department of Community Services EWB: eet Enclosure - - - .. I.. _flrrW(!'il~~~jj~'~~.'I..~ # ... ... ~~ Schneider INDIANA Corporate Headquarters Historic Fort Harrison 8901 otis Avenue Indianapolis, IN 46216 Phone: 31.7 .826. 7100 Toll.Free: 866.973.7100 Fax: 317.8267200 Lafayette Office 3725 Rome Drive Park 26 Lafayette. IN 47905 Phone: 765.448.6661 Fax: 765.448.6665 Carmel Office 12821 E New Market Street Suite 100 Carmel, IN 46032 Phone: 317.569,8112 Fax: 317.826.6410 Avon Office Building 1000 5250 E US Highway 36 Suite :<50 Avon. IN 46123 Phone: 317 .745.9926 Fax: 317.H5.9973 Merrillville Office 9800 Cormecticut Drive Suite 81.508 Merrillville, IN 1\6307 Phone: 219644.3692 Fax: 219.644.3682 NORTH CAROLINA Ch a r10tte Office 2151 Hawkins Street SUite 201 Charlotte. NC 28203 Phone: 704.333.8360 Fax: 704.333.8362 IOWA ProMap Office 1531 Airport Road Suite 2 Ames, iA 50010 Phone: 515.233.3311 Fax: 515.233.4575 u u The Schneider Corporation Historic Fort Harrison 8901 Otis Avenue Indianapolis, IN 46216.1037 Phone: 317.826.7100 Fax: 317.826.7200 September 6, 2006 Shirley Hunter Cinergy PSI Customer Project Coordinator 1441 South Guilford Rd Carmel, IN 46032 RE: Stafford Lane - Secondary Plat & Construction Plans TSC 5622.001 Dear Shirley: A copy of the Secondary Plat and construction plans for the referenced project is enclosed. Our understanding is that this information will be reviewed at the September 20, 2006 Carmel Technical Advisory Committee (T AC) meeting. Please review the information and return any comments to us you may have. Should you have any questions please call us. Sincerely EG~ Eric W. Batt, PE Project Manager cc: Matt Griffin - Carmel Department of Community Services EWB: cet Enclosure __~;rcl~~ltj(~~tZ~~R'ilJalm1 : Des rans- e - ax . DC " " i' 'D ~~ Schneider INDIANA Corporate Headquarters Historic Fort Harrison 8901 otis Avenue Indianapolis, IN 46216 Phone: 317.826.7100 Toll-Free: 866.973.7100 Fax: 317.826.7200 Lafayette Office 3725 Rome Drive Park 26 Lafayette, IN 47905 Pl1one: 765.448,6661 Fax: 765.448.6665 Carmel Office 12821 E New Market Street Suite 100 Carmel. IN 46032 Phone: 317.569.8112 Fax: 317 .8266410 Avcn Office Building 1000 5250 E US Highway 36 Suite :.!50 Avon. IN 46123 Phone: 317.745.9926 Fax: 317.745.9973 Merrillville Office 9800 Connecticut Drive Suite B1-508 Merrillville, IN 46307 Phone: 219.644.3692 Fax: 219.644.3682 NORTH CAROUNA Charlotte Office 2J51 Hawkins Street Suite 20J Charlotte, NC 28203 Phon'e' 704.333.8360 Fax: 704.333.8362 IOWA ProMap Office 1531 Airport Road Suite 2 Ames, IA 50010 Phone: 515.233.3311 Fax: 5J5.233.4575 u u The Schneider Corporation Historic Fort Harrison 8901 Otis Avenue Indianapolis, IN 46216.J037 Phone: 317.826.7100 Fax: 317 .826.7200 September 6, 2006 Teresa Magee Panhandle Eastern Pipeline Co. 9371 Zionsville Road Indianapolis, IN 46268 RE: Stafford Lane - Secondary Plat & Construction Plans TSC 5622.001 Dear Teresa: A copy of the Secondary Plat and construction plans for the referenced project is enclosed. Our understanding is that this information will be reviewed at the September 20, 2006 Carmel Technical Advisory Committee (TAC) meeting. Please review the information and return any comments to us you may have. Should you have any questions please call us. Sincerely ~LJJ~ Eric W. Batt, PE Project Manager cc: Matt Griffin - Carmel Department of Community Services EWB: cet Enclosure I~ _~"'~'B"~.~"M'''''''''''''' . Sb.(:L\VU I~:a:~ rans- e - ax I . oc