HomeMy WebLinkAbout04 - A1.2Drawn By Checked By
Architecture / Project Managment:
Carmel, Indiana 46032
317.705.7980 (fax)
355 City Center Drive
317.705.7979 (phone)
SEAL:
COPYRIGHT & OWNERSHIP OF DOCUMENTS
ARCHITECT / PROJECT MANAGEMENT
SIGNATURE
PROJECT
PROJECT NUMBER
SHEET TITLE
SHEET NUMBER
REVISION DATE
ISSUE DATE
Print Date
SUITE 400
OLD TOWN SHOPS I
HENKE DEVELOPMENT GROUP
1 SOUTH RANGELINE ROAD
11/7/08 CHECK SET
CARMEL, INDIANA 46032
11/7/08 STATE RELEASE SET
11/12/08 CONSTRUCTION SET
PEDCOR DESIGN GROUP
CEILING/
ELECTRICAL
PLANS
11/12/08
A1.2
THIS DOCUMENT IS AN INSTRUMENT OF SERVICES AND IS THE SOLE PROPERTY
OF THE ARCHITECT AND PEDCOR DESIGN GROUP, L.L.C. ALL INFORMATION
CONTAINED HEREIN IS CONFIDENTIAL. ITS SUBMISSION AND DISTRIBUTION TO
OTHER PARTIES IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION
OF COMMON LAW COPYRIGHT, INTELLECTUAL PROPERTY RIGHTS OR OTHER
RESERVED RIGHTS. ALL INFORMATION CONTAINED HEREIN CONSTITUTES THE
ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT, JAMES R. STUTZMAN,
AND PEDCOR DESIGN GROUP, L.L.C. NO PART OR WHOLE OF THIS DESIGN,
THESE DRAWINGS, OR THE RESULTING BUILDING OR BUILDINGS, OR PORTIONS
OF THE RESULTING BUILDING OR BUILDINGS MAY BE DUPLICATED, COPIED,
EXHIBITED, PHOTOGRAPHED, PUBLISHED, MODIFIED OR OTHERWISE
DISTRIBUTED IN ANY WAY WITHOUT THE SPECIFIC AND PRIOR WRITTEN
CONSENT OF THE ARCHITECT, JAMES R. STUTZMAN AND PEDCOR DESIGN
GROUP, L.L.C. c COPYRIGHT 2006,2007,2008 JAMES R. STUTZMAN, AIA,
CARMEL, INDIANA
LES MC
11/12/08
2
A1.5
1
A1.5
3
A1.5
TYP.
3
A1.5
TYP.
7'-6"
TIGHT TO JOIST
CP1
CP4
CP3
NL
NL
NL
3
3
3
10 9 7 6 5
E.8 E D C.2 B A
E
E
D
3
NL
D
D
R
EP1
EP2
EP2
EP2
REST ROOM
403
REST ROOM
404
RECEPTION
401
FUTURE OFFICE
411
OFFICE
410
OFFICE
409
CONFERENCE ROOM
408
WORK ROOM
405
CLOSET
402
OFFICE
407
OFFICE
406
+44
N
N
N N
N
N N
N
N
N
N
N N
+44
N
N CL.
412
CORRIDOR
415
+44
N
10 9 7 6 5
E.8 E D C.2 B A
CORRIDOR
416
CORRIDOR
414
N
C
C
N
N
C
N
N
N
+44
N
+44
N
+44
N
+44
N
+44
N
+44
N
+44
N
+44
N
+44
N
+60
N
+44
GFI
N
EP1
EP2
GENERAL ELECTRICAL/DATA NOTES:
ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOXES WITH BOX AND PULL
STRING AT PHONE AND DATA LOCATIONS AS INDICATED ON PLANS. COMPLETE
PHONE AND DATA SYSTEMS (MATERIAL & LABOR) PROVIDED BY THE TENANT
UNLESS OTHERWISE INDICATED.
ELECTRICAL CONTRACTOR TO INSURE DEDICATED OUTLETS OR OTHER SPECIAL
ELECTRICAL REQUIREMENTS TO BE COMPATIBLE WITH TENANT EQUIPMENT. VERIFY
ACTUAL REQUIREMENTS WITH ELECTRICAL ENGINEER, OWNER, AND/OR
DESIGN-BUILD CONTRACTOR PRIOR TO INSTALLATION.
ALL WALL MOUNTED OUTLETS AND PHONE/DATA JUNCTION BOXES TO BE MOUNTED
@ 18" AFF UNLESS NOTED OTHERWISE.
6.
5.
4.
3.
2.
ELECTRICAL/DATA PLAN NOTES: ELECTRICAL/DATA LEGEND:
COORDINATE AFTER HOURS LOCK-OFF OF THE ELEVATOR TO THE 4TH FLOOR.
ALL CONDUCTORS SHALL BE INSTALLED IN CONDUIT. EXPOSED CONDUIT IS TO BE RIGID.
ALL ELECTRICAL COVER PLATES AND SWITCH PLATES TO MATCH COLOR OF EXISTING COVER
PLATES.
DUPLEX WALL OUTLET.
PHONE/DATA WALL OUTLET (BOX AND PULL STRING).
DENOTES NEW OUTLET LOCATION.
DENOTES HEIGHT A.F.F. TO CENTER OF OUTLET.
N
+44
D DENOTES A DEDICATED OUTLET.
REMOVE EXISTING OUTLET. PATCH AND PAINT WALL.
FLOOR OUTLET WITH DUPLEX POWER AND DATA.
1. FURNITURE SHOWN FOR REFERENCE ONLY.
C CABLE OUTLET.
GFI GROUND FAULT INTERRUPT CIRCUIT.
GENERAL CEILING NOTES:
1. MECHANICAL AND ELECTRICAL IS DESIGN-BUILD. DESIGN-BUILD CONTRACTOR TO VERIFY EXISTING
CONDITIONS AND COORDINATE DESIGN OF RELOCATED AND NEW DIFFUSERS, SPRINKLER HEADS, FIRE
PROTECTION DEVICES, EXIT LIGHTS, EMERGENCY NIGHT LIGHTS, AND THERMOSTATS. DESIGN-BUILD
CONTRACTOR TO COORDINATE HIS WORK WITH THE LIGHTING PLAN. ALL QUESTIONS ARE TO BE
BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. REFER TO MECHANICAL
DRAWINGS FOR RELOCATION OF THERMOSTATS. CONTRACTOR TO VERIFY WITH TENANT AND
FURNITURE SUPPLIER THERMOSTAT LOCATIONS FOR PANEL LOCATION CONFLICTS BEFORE
PROCEEDING.
5.
6.
4.
3.
2.
ALL WALLS GO TO 6" ABOVE FINISHED CEILING UNLESS NOTED OTHERWISE. SEE CONSTRUCTION
PLAN FOR OTHER WALL TYPE INFORMATION.
EACH ROOM TO HAVE INDIVIDUAL SWITCH LOCATED ON WALL AT DOORWAY TO
ROOM, TYPICAL UNLESS NOTED OTHERWISE. IN LOCATIONS OF 2 OR MORE
SWITCHES IN CLOSE PROXIMITY, SWITCHES ARE TO BE CONSOLIDATED TO A GANG
PLATE CONDITION.
ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR DESIGN-BUILD OF ALL SAFETY SYSTEMS.
CONTRACTOR IS TO VERIFY QUANTITY AND PLACEMENT OF INDICATED SAFETY DEVICES (EXIT SIGNS,
ALARMS, ETC.) AND VERIFY CONFORMANCE WITH LOCAL AND STATE CODES. LIFESAFETY
CONTRACTOR IS RESPONSIBLE FOR SUBMITTING NECESSARY DRAWINGS FOR REVIEW AND OBTAINING
PERMITS. LIFESAFETY CONTRACTOR IS RESPONSIBLE FOR SUBMITTING DRAWINGS TO ARCHITECT FOR
REVIEW AND COORDINATION OF LOCATION OF DEVICES. DESIGNER REVIEW IS FOR AESTHETIC REVIEW
ONLY.
CONTRACTOR TO VERIFY EXISTING CONDITIONS TO LAYOUT AND REPORT ANY DISCREPANCIES TO
ARCHITECT BEFORE PROCEEDING WITH CONSTRUCTION.
ALL SUSPENDED CEILING HEIGHTS ARE TO BE 8'-0" UNLESS NOTED OTHERWISE. ADJUST DUCT
HANGERS AS REQUIRED TO PROVIDE CEILING HEIGHT.
CEILING PLAN NOTES:
CP1 4 7/8" WIDE DRYWALL BULKHEAD @ 7'-6" A.F.F.
REFLECTED CEILING LEGEND:
NEW 2 X 2 FLUORESCENT LIGHT FIXTURE TO BE: LITHONIA LIGHTING, GENERAL PURPOSE T8 TROFFER,
GT8 2X2, 2GT8 2 U31 PC1S MVOLT GEB10IS, OR EQUAL.
EXISTING EMERGENCY LIGHT FIXTURE.
NEW 2 X 2 LAY-IN GRID SUSPENSION SYSTEM TO BE: ARMSTRONG, DUNE, BEVELED TEGULAR,
W/ SUPRAFINE XL 9/16" GRID.
EXISTING WALL MOUNTED EXIT LIGHT TO BE: LITHONIA LIGHTING, SURFACE MOUNT EDGE-LIT EXIT LIGHT,
EDG 1R 120/277 ELN, OR EQUAL.
TWO WAY SWITCH.
3 THREE-WAY SWITCH.
NL NIGHTLIGHT LOCATION.
CP2 REMOVE EXISTING EMERGENCY LIGHT FIXTURE.
E EXISTING LIGHT SWITCH LOCATION.
7. REMOVE ALL EXISTING SUSPENDED LIGHT FIXTURES AND RETURN TO BUILDING OWNER.
CP3 RELOCATE EXISTING EMERGENCY LIGHT FIXTURE.
NEW 2 X 4 FLUORESCENT LIGHT FIXTURE TO BE: LITHONIA LIGHTING, GENERAL PURPOSE T8 TROFFER,
2GT8 2X4, 2GT8 5 32 PC1S MVOLT GEB10IS, OR EQUAL.
NEW PENDANT LIGHT FIXTURE TO BE: HUBBARDTON FORGE, SMALL EXOS PENDANT #139590, WITH
SATIN STEEL -19 FINISH, NATURAL LINEN-32 SHADE, AND A-19 100W LAMP.
NEW RECESSED DOWNLIGHT TO BE: DMF LIGHTING, DHFV6 132 TRT DELEC D6261SF W/ TRIPLE
TUBE FLUORESCENT LAMPS, OR EQUAL.
D DIMMER SWITCH LOCATION.
CP4 4 7/8" WIDE DRYWALL BULKHEAD @ 8'-0" A.F.F.
SCALE: 1/8" = 1'-0"
1 REFLECTED CEILING PLAN
A1.2
SCALE: 1/8" = 1'-0"
2 ELECTRICAL/DATA PLAN
A1.2