Loading...
HomeMy WebLinkAboutPermit Revision01J:\535-NVCLC\3581-0\AGENCY APPROVALS\Permit\535-3581 Permit Revision01.doc Permit Revision No. 01 Indiana Department of Homeland Security - Project #333848 City of Carmel, building & Code Services - Project #08060140 Project: Northview Christian Life Church New Worship Center Date: 02.09.09 Project No: 535-3581 This ASI provides information to clarify or adjust construction items which may affect any or all trade contractors. Directives to proceed with any of the work and all change orders are to be reviewed and approved by the General Contractor , Architect, Engineer, and Owner. This ASI is for information only and is not an instruction to execute work nor stop work in progress or portions thereof unless herein written. All work to be in strict accordance with the terms, stipulations and conditions of contract documents. PART 1 – ARCHITECTURAL DRAWINGS A1 SHEET A001 1. Revise plumbing fixture counts to include the entire existing and new building. A2 SHEET A211-A 2. Revise loading dock layout. 3. Revise partition type at shaft in Workshop #116. 4. Add partition type in Side Platform #120. 5. Revise keynotes #8 and 18. Add keynotes #24-28. 6. Revise layout of stair #2 at level 1. 7. Revise layout of Men’s Restrooms #108, Women’s Restroom #111 and divide Women’s Restroom #110 into Women’s Restroom #110A & Women’s Restroom #110B. A3 SHEET A503 & A508 8. Revise Pit Level Entry retaining wall and stair layout. Add guardrail on retaining wall. PART 2 – PLUMBING DRAWINGS P1 SHEET P002 9. Modify Water Heater – Pit Level, Detail E – Delete HVAC make-up water backflow preveneter (note #3). P2 SHEET P003 10. Modify gas connected load schedules. P3 SHEET P201 11. Modify underfloor piping to accommodate toilet room changes. P4 SHEET P202 12. Modify gas piping for revised HVAC equipment. Delete backflow preventer in mechanical room. P5 SHEET P203 13. Modify gas piping for revised HVAC equipment. Modify above floor piping and fixtures in toilet rooms. J:\535-NVCLC\3581-0\AGENCY APPROVALS\Permit\535-3581 Permit Revision01.doc P6 SHEET P206 14. Modify gas piping for revised HVAC equipment P7 SHEET P300 15. Modify Soil, waste and vent diagrams for toilet room revisions. PART 3 – HVAC DRAWINGS H1 SHEET H300 16. Delete sheet H300 Mechanical Room. H2 SHEET H400 17. Delete sheet H400 Hot Water Piping Schematic and Data H3 SHEET H001 18. Revised these Schedules - Air Control Units-Hot Water to Electric, Room Heating Units (H.W. to Electric), Sound Attenuators, Cooling/Heating Split Systems (H.W. to Electric), Cooling Split System, Air Distribution Devices and Air Supply Rooftop Unit Schedule. H4 SHEET H003 19. Deleted these details – Propeller Unit Heater-HW, Cabinet Unit Heater-HW, Air Terminal Reheat Coil (2-way and 3-way)-HW, Rooftop unit HW Heating coil(2 details) and Under floor duct detail. Updated sections 1 & 2. H5 SHEET H201 20. Pit Level Floor Plan – Modified Heating & A/C system and Deleted Hot Water System and replaced with Electric Heat source. H6 SHEET H211 21. First Level Floor Plan – Modified Heating & A/C system and Deleted Hot Water System and replaced with Electric Heat source. Modified Rooftop unit(s) supply and return air distribution. H7 SHEET H221 22. First Level Balcony Floor Plan – Modified Heating & A/C system and Deleted Hot Water System and replaced with Electric Heat source. Modified Rooftop unit(s) supply and return air distribution. H8 SHEET H231 23. Second Level Balcony Floor Plan – Modified Heating & A/C system and Deleted Hot Water System and replaced with Electric Heat source. Modified Rooftop unit(s) supply and return air distribution. H9 SHEET H301 24. Rooftop Equipment Sections – Modified Rooftop unit elevations and quantity. PART 4 – ELECTRICAL DRAWINGS E1 SHEET E001 25. Revised Motor, Starters, Disconnects & Controls schedule. J:\535-NVCLC\3581-0\AGENCY APPROVALS\Permit\535-3581 Permit Revision01.doc E2 SHEET E300 26. VAV boxes have been changed from hot water heating to Electric heating with Electric heating coils. Circuits have been added. 27. New Electrical panel RP-7 has been added to provide circuits to heating coils for VAV boxes. 28. Boilers and pumps have been deleted. Accordingly feeders to these units have been deleted. 29. HVAC has modified hot water cabinet and unit heaters to Electric. Circuits have been added. E3 SHEET E301 30. HVAC has modified hot water cabinet and unit heaters to Electric. Circuits have been added. 31. Power device locations were modified to reflect new room layouts in Men’s restroom 108, Janitor’s room 109, Women’s restroom 110 and Women’s restroom 111. E4 SHEET E302 32. An additional Rooftop unit has been added (RTU–5) - 208V, 3 Ph., Circuit have been provided for the same. E5 SHEET E400 33. Revised single line diagram and main distribution schedule. E6 SHEET E402 34. Revised panelboard schedule “RP4.” E7 SHEET E403 35. Revised panelboard schedule “RP6” and added panelboard schedule “RP7”. END OF PERMIT REVISION UP UP UP F.E.C. F.E.C. F.E.C. DN UP F.E.C. DN DN DN UP UP UP DN UP DN DN UP F.E.C. F.E.C. F.E.C. F.E.C. F.E.C. DN F.E.C. UP DN 1 3 5 H3 2.3 4 X9 X2 X3 X6 X7 X8 H2 4.6 4.6 M ND H1.5 1.5 1.5 H3.2 X 2.0 3.8 H1 0.8 2.6 3.6 Y2 G X10 X4 X5 X1 0.4 2.4 2.8 3.3 4.4 Y E F P9 4.1 DN DN UP UP DN UP UP UP F.E.C. F.E.C. F.E.C. F.E.C. UP DN A301 A301 3 2 1 A411 2 A411 118A 102A 102B WORKSHOP 116 STORAGE 115 DELIVERY 118 WOMENS' REST RM. 111 VESTIBULE 102 VEST. 112 107 106 103A 103B 113 112 103C 103D 102D 102C 0" -3' - 0" VEST. 107 VESTIBULE 106 VEST. 113 3 118D 116B STAIR-1 S-11 WOMENS' REST RM. UP DN F.E.C. DN UP F.E.C. UP DN . F.E.C. DN UP F.E.C. UP UP P M L L C L4 ND L3 P12 P10 M1 P9 1 A504 FIRST BALCONY LEVEL BELOW INTERMEDIATE LANDING ONE SECOND BALCONY LEVEL STAIR-3 S-33 1' - 0" 1' - 11" 14 TREADS DN @ 11" = 12' - 10" 17 TREADS UP @ 11" = 14' - 8" 1' - 10" 4' - 4" F4 F4 4' - 6" 4" A521 13 P M L C L4 S L3 P12 P10 42" HIGH TELESCOPING SAFETY POST WITH EYEHOOK 3'-0" X 8'-0 ROOF HATCH WITH 1" FIBERGLASS INSULATION IN COVER, COMBINATION LOCK STRIKE AND PADLOCK HASP AND SPRING LATCH WITH INSIDE-OUTSIDE HANDLES CURB WITH INTEGRAL CAPFLASHING AND POSIFLASH PAINTED ALTERNATING TREAD DEVICE EXISTING STEEL BEAM GASKET AT PERIMETER EDGE OF ROOF HATCH BRACKET ALTERNATING TREAD DEVICE OFF OF EXISTING BEAM CLIP ANGLE AND EXP. BOLT TO FLOOR, EACH SIDE 21 EQUAL SPACES PIT ROOF 824' - 7 5/8" J 6' - 9" V.I.F. CONTINUOUS PRE-FINISHED ALUMINUM DRIP EDGE FULLY ADHERED EPDM ROOF SYSTEM; 2 LAYERS OF 1.5" RIGID INSULATION ON STEEL DECK; ADDITIONAL TAPERED INSULATION AS REQUIRED TO MAINTAIN MINIMUM SLOPE 1/4" PER FT. REF. A251 FOR TAPERED INSULATION LOCATIONS CONTINUE ROOF MEMBRANE UP PARAPET WALL; TERMINATE BENEATH DRIP EDGE 2" RIGID INSULATION; BUILDING WRAP; 1/2" EXTERIOR GYPSUM SHEATHING & 6" STEEL STUDS @ 16" O.C.; 6" BATT INSULATION & VAPOR BARRIER; 5/8" TYPE 'X' GYPSUM SHEATHING FULLY ADHERED EPDM ROOF SYSTEM; 2 LAYERS OF 1.5" RIGID INSULATION ON STEEL DECK; ADDITIONAL TAPERED INSULATION AS REQUIRED TO MAINTAIN MINIMUM SLOPE 1/4" PER FT. REF. A251 FOR TAPERED INSULATION LOCATIONS 8" R 1' - 1" CONSTRUCT LADDER RAILS FROM 3/8" X3" BAR STOCK. SPACE SIDES 24"APART. NOTE: ALL STEEL FOR LADDER, INCLUDING BRACKETS AND FASTENERS TO BE HOT DIPPED GALVANIZED STEEL 3/4" DIA. RUNGS AT 12" O.C. TYP. MOUNTING BRACKETS WITH 3/4" EXP BOLTS INTO EXTERIOR WALL AT 4'-0" O.C. TYP. BRACKETS TO BE MADE FROM 3/8" X3" BAR STOCK. PROVIDE NON-COMB. CONTINUOUS WD BLOCKING AS REQUIRED FOR BRACKET ATTACHEMENTS FIRST FLOOR 817' - 7 5/8" 3" X 1" X .122" WELDED WIRE MESH WITH 1" U-CHANNEL FRAME WELDED TO METAL TUBES, PAINTED, TYPICAL 11 EQUAL 28' PANELS - 5" 2" SQUARE TUBE, PAINTED 3-7/8" MAXIMUM OPEN SPACE FROM BOTTOM TUBE TO TOP OF RETAINING WALL SCALE: S S S S S SCALE: SCALE: SCALE: NONE NONE NONE NONE LIFT PIT FLOOR 2.5" 2.5" 1.25" 1.5" 0.75" 1.25" 1.25" 0.75" 0.75" 4"x3" REDUCING ELL 1.5" 0.75" 0.5" 0.5" 1.5" 1" 1" MOP BASIN 4" HIGH CONCRETE BASE PACKAGE FIRE PUMP SYSTEM FIRE PUMP: 750 GPM @ 108 FT HD MOTOR: 30 HP, 208 VOLT, 3 PHASE JOCKEY PUMP: 10 GPM @ 147 FT HD MOTOR 0.75 HP, 208 VOLT, 3 PHASE REFER TO SPECIFICATION SECTION 21 31 13 2" MAIN DRAIN EXTEND ALL DRIPS AND DRAINS FROM FIRE PUMP PACKAGE TO FLOOR DRAIN. 6" DOUBLE DETECTOR CHECK ASSEMBLY PIT LEVEL 6" TO FIRE RISERS AND FLOOR CONTROL VALVES 2.5" TO FIRST LEVEL FIXTURES 1.5" TO PIT LEVEL FIXTURES 3" 6" 6" FLOOR SINK (BY PC) 1.5" 2.5" TO WALL MOUNTED FIRE PUMP TEST HEADER LIFT PIT SUMP PUMP FIRE SERVICE AND PUMP WATER SERVICE NOTES ELEVATOR SUMP PUMP WATER HEATER - PIT LEVEL NOTES UP UP UP F.E.C. DN UP UP UP UP 1 1 CO CO 4" SANITARY INV. 809.00' 6" STORM 2,660 SQ.FT. INV. 809.00' 5" DS C2 FD1 C2 D1 A1 FD1 A3 A4 B2 B2 D1 FD2 F2 FD2 CO F1 2 2 INV. 813.50' INV. 813.80' VR 3 3 3 3 2.5" DCW UP 2.5" DCW 3 3 6" STORM 4,350 SQ.FT. INV. 814.00' 1 CO 5" DS 2" GAS SERVICE @ 2 PSI 4 5" DS 3,170 SQ.FT. 6" ST INV. 807.50' INV. 816.00' 1 M UP UP UP UP F.E.C. F.E.C. F.E.C. DN UP UP UP UP 4" FR UP, 2.5" FR DN 4" FR UP 2.5" FR DN FDV B1 FDV A4 B1 RD3 5" DS 3,170 SQ.FT. 5" STORM 3,170 SQ.FT. 4,615 SQ.FT. 6" STORM 6" DS 4,615 SQ.FT. 2.5" FR UP FDV 2.5" FIRE B2 B2 A3 G1 F1 D1 FD2 FD2 2" GAS @ 2 PSI 2" GAS @ 2 PSI 5 4 10 1 0.5" DHW 0.75" DCW VTR WH 0.75" DCW F2 3 6" FR UP 6" FIRE 6" FIRE PUMP TEST HEADER PIPING 6" FIRE SERVICE 0.5" DCW D N R O F R D A C EC SS H TA HC S UC PP RE S UC PP RE S UC PP RE S UC PP RE S UC PP RE S UC PP RE S UC PP RE S UC PP RE S UC PP RE S UC PP RE S UC PP RE S UC PP RE A C EC SS H TA HC S M O K H E CTA SEH S UC PP RE 1 1 1 2 2 1 4 4 1 1 2 2 3 4 R UT 53 2 HFC R UT 2 5 33 HFC 2 R UT 5 33 HFC 2 R UT 22 35 HFC F .E .C R 2 ,065 S 3D Q .TF . R 2D 1 ,097 S Q .TF . R 2 ,066 S 3D Q .TF . R 3D 3 ,570 S Q .TF . R 3D 3 ,043 S Q .TF . R 1D 1 ,030 S Q .TF . R 2D 2 ,041 S Q .TF . R 2D 2 ,091 S Q .TF . R 3D 3 ,071 S Q .TF . R 4D 4 ,516 S Q .TF . R 1 ,063 S 2D Q .TF . R 2D DN ROOF RD ACCESS HATCH SCUPPER SCUPPER SCUPPER SCUPPER SCUPPER SCUPPER SCUPPER SCUPPER SCUPPER SCUPPER SCUPPER SCUPPER ACCESS HATCH SMOKE HATCHES SCUPPER 1 1 1 2 1 4 4 1 1 2 2 4 6 6 5 6 6 6 RTU 2 235 CFH RTU 5 533 CFH 2 RTU 1 533 CFH 2 RTU 4 150 CFH G 1.5" 1.25" 1" RTU 3 533 CFH 5 G G G G 1.25" 1.25" 2" 1" 2" SOIL WASTE AND VENT DIAGRAM SCALE: NONE D2 CO 2" 2" 1.5" 1ST 3" VTR 3" VTR 3" VTR 3" VTR 3" VTR 4" 4" 4" 4" 4" 4" 4" D1 A1 A2 A2 1ST FD1 1ST 4" 4" 4" 3" 3" 1.5" 2" 2" 2" 2" C2 C2 C2 C2 2" 2" 3" 2" 1ST 1ST 2" 1.5" 1.5" 1.5" 3" 3" 2" 2" 3" 1ST 1ST 1ST B1 B1 PLUMBING CONTRACTOR P.C. HVAC CONTRACTOR H.C. ELECTRICAL CONTRACTOR E.C. GENERAL CONTRACTOR G.C. NOT IN HVAC CONTRACT N.I.H.C. THERMOSTAT - MOUNTING HEIGHT 46",TO MEET ADA REQUIREMENTS. WHEN MOUNTED NEXT TO WALL SWITCH COORDINATE WITH ARCHITECT. T S SPACE TEMPERATURE SENSOR. 123 ROOM NUMBER. EQUIPMENT ITEM. (TO BE USED AS AID IN COORDINATING THE VARIOUS TRADES.) APPROXIMATE ELEVATION FROM FLOOR TO BOTTOM OF DUCT, PIPE, DEVICE OR 9'-8" SECTION "A" DESIGNATION , SHOWN ON SHEET H1.01. H1.01 A DETAIL "A", SHOWN ON SHEET H1.01. H1.01 A 8"D = NECK SIZE. 300 = REQUIRED CFM. 3 = AIR DISCHARGE IF OTHER AIR DEVICE A3 = DESIGNATION - REFER TO AIR DEVICE SCHEDULE. THAN 4-WAY. METHOD OF IDENTIFICATION ALSO APPLIES TO OTHER CEILING MOUNTED DEVICES. A3-8"D 300-3 WALL OR DUCT MOUNTED AIR DEVICE. G1 = DESIGNATION - REFER TO AIR DEVICE SCHEDULE. 24"x16" = DUCT CONNECTION SIZE. 200 = REQUIRED CFM. 9'-4" = MOUNTING HEIGHT FROM FLOOR TO BOTTOM OF DEVICE. 200-9'-4" G1-24x16 FACE AREA IN SQ. FT. DL-2 DOOR LOUVER BY GENERAL CONTRACTOR. NUMBER INDICATES MINIMUM GROSS DOOR UNDERCUT BY GENERAL CONTRACTOR. U/C R DUCT RISE IN DIRECTION OF AIR FLOW. D DUCT DROP IN DIRECTION OF AIR FLOW. DUCT WITH 1" ACOUSTICAL LINER. DUCT SIZES ARE INSIDE CLEAR DIMENSIONS. DUCT CONSTRUCTED OF SPECIAL MATERIAL AS NOTED. FLEXIBLE DUCT CONNECTION. AIR TURNING VANES. MANUAL BALANCING VOLUME DAMPER WITH LOCKING DEVICE. M.D. FIRE DAMPER - LETTER "A", "B", OR "C" INDICATES TYPE REQUIRED, LETTER "D" OR "S" INDICATES DYNAMIC OR STATIC - SEE DETAIL. A-D SMOKE DAMPER. S COMBINATION FIRE SMOKE DAMPER. FS PRESSURE GAUGE. P UNION. CLEAN OUT. STRAINER. SHUTOFF VALVE SCALE: NONE SUPPLY FAN T.S.P. (INCH W.G.) + 2". CENTERLINE DIMENSION NOT LESS THAN 4" MINIMUM - CENTERLINE TO CENTERLINE. TEE WITH CLEANOUT PLUG. PAN CONNECTION. DRAIN PIPE SAME SIZE AS UNIT DRAIN ROOFTOP UNIT SPLASH BLOCK. ROOF TRAP UNIT ROOF CURB. VERIFY REQUIRED HEIGHT FOR DRAIN PIPE AND TRAP INSTALLATION. PROVIDE CURB OF ADEQUATE HEIGHT TO ATTAIN REQUIRED DIMENSION. A H003 2 5 4 3 1 6 6 1 2 3 3 5 ROOFTOP UNIT DRAIN PIPING DRAW-THRU UNIT 40/26 12' - 8 1/2" 8/8 RTU-3 9' - 1" AC-3 44/28 10' - 10" 48/20 50/21 14"D 12' - 0" 13' - 11" 13' - 11" RTU-4 10/6 8"D 10' - 0" 8' - 10 1/2" 24"D 24"D 12"D 8"D S3 - 105 CFM 6" (3) 12"D 8"D UP UP UP F.E.C. F.E.C. F.E.C. DN UP CUH-2 CUH-1 12"D 4-13 4-12 A1 - 8" 200 CFM T A1 - 6" 100 CFM A1 - 8" 275 CFM A1 - 6" 100 CFM A1 - 6" 100 CFM A1 - 6" 100 CFM A1 - 6" 100 CFM A1 - 6" 100 CFM 14"D F1 - x 100 CFM 12 6 (3) 16"D A1 - 6" 75 CFM A1 - 6" 50 CFM A1 - 6" 50 CFM 8"D 10"D A1 - 6" 50 CFM A1 - 6" 50 CFM A1 - 6" 75 CFM 4-10 A1 - 6" 125 CFM A1 - 8" 175 CFM A1 - 6" 75 CFM A1 - 8" 175 CFM (2) A1 - 8" DN DN UP UP DN UP UP UP F.E.C. F.E.C. F.E.C. F.E.C. DN UP DN A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A AA AB AD 1 3 5 H3 2.3 4 X9 X2 X3 X6 X7 X8 H2 4.6 H4 P 4.3 H5 4.8 M L C L4 Q S T ND U H1.5 1.5 H3.2 X 2.0 3.8 H1 2.6 3.6 0.8 G Y2 Z L2 DN UP DN UP DN DN UP UP F.E.C. F.E.C. A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A AA AB AD AE 1 3 5 H3 2.3 4 X9 X2 X3 X6 X7 X8 H2 4.6 H4 P 4.3 H5 4.8 M L C L4 Q S T ND U H1.5 1.5 H3.2 X 2.0 3.8 H1 2.6 3.6 0.8 G Y2 Z L2 L3 P12 P15 X10 DN UP DN DN DN DN DN DN A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A AA AB 1 3 5 H3 2.3 4 X9 X2 X3 X6 X7 X8 H2 4.6 H4 P 4.3 4.8 M L C L4 Q S T ND U H1.5 1.5 H3.2 X 2.0 3.8 H1 2.6 3.6 0.8 G Y2 Z L2 L3 P12 P15 X10 X4 X5 X1 0.4 2.4 2.8 3.3 4.4 Y E R.A. E.A. O.A. S.A. R.A. E.A. O.A. S.A. R.A. E.A. O.A. S.A. R.A. E.A. O.A. S.A. R.A. E.A. O.A. S.A. A ALL UNITS SHALL BE SET ON MIN. 14" ROOF CURB. CURBS TO BE FIELD ASSEMBLED. B RTU-1,3,5 (40 TONS) SERVE WORSHIP CENTER SHALL BE APPROX. 255" L. X 92" W. X 64" H. WITH APPROX. WEIGHT OF 6500 LBS. C RTU-2 (30 TONS) SERVE STAGE SHALL BE APPROX. 240" L. X 92" W. X 64" H. WITH APPROX. WEIGHT OF 6000 LBS. D RTU-4 (30 TONS) SERVE PIT LEVEL. E ROOFTOP STANDARD CLEARANCES SHALL BE - 60" TO FRONT, RIGHT, LEFT, BACK AND 120" TO TOP. F ROOFTOP UNIT ACCESS DOORS PER SPEC. AND UNIT MF'R. RECOMMENDATIONS. G REFER TO ROOFTOP UNIT SCHEDULE, DRAWING H001. H REFER TO PLUMBING DRAWINGS FOR GAS PIPING TO ROOFTOP UNITS. J REFER TO DETAIL "A", H003 FOR ROOFTOP DRAIN PIPING. ROOFTOP UNIT GENERAL NOTES SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" SCALE: 1/4" = 1'-0" PACKAGED ROOFTOP UNIT RTU-3 PLAN VIEW PACKAGED ROOFTOP UNIT RTU-1 PLAN VIEW PACKAGED ROOFTOP UNIT RTU-2 PLAN VIEW PACKAGED ROOFTOP UNIT RTU-4 PLAN VIEW PACKAGED ROOFTOP UNIT RTU-5 PLAN VIEW Date: Scale Drawn By Checked By Project Number ARCHITECTURE PLANNING INTERIOR DESIGN STRUCTURAL ENGINEERING 424 East Fourth Street Cincinnati, w w w . c h a r c h Ohio i t e c t s . 45202 c o m tel: 513/241/4474 fax: 513/241/0081 ISSUANCES COMPUTER FILE 1400 West Dorothy Lane Dayton, Ohio 45409-1310 Tel: (937) 224-0861 Fax: (937) 224-5777 MOTORS, STARTERS, DISCONNECTS & CONTROLS LIGHTING FIXTURES LEGEND NORMAL/EMERGENCY CIRCUIT SCHEDULE GENERAL NOTES WP/GF J H1 a B1 b LIGHTING FIXTURE; CAPITAL LETTER DENOTES FIXTURE TYPE. LOWER CASE LETTER DENOTES SWITCHING ARRANGEMENT. EXIT LIGHTING FIXTURE. COORDINATE EXIT SIGN ARROWS WITH ARCHITECTURAL EGRESS PATHS - SEE ARCHITECTURAL DRAWINGS. ELECTRICAL CONNECTION REQUIRED. ~ 123 ROOM NUMBER. 2 DETAIL NOTE SYMBOL - APPLIES ONLY TO DETAIL ON WHICH NOTE IS SHOWN. 3 NOTE SYMBOL - APPLIES ONLY TO SHEET ON WHICH NOTE IS SHOWN. GROUND FAULT FEED THRU GFFT CIRCUIT CKT MOUNTING HEIGHT TO CENTERLINE OF ITEM UNLESS INDICATED OTHERWISE ON MH DRAWINGS. ABOVE FINISHED FLOOR - TO BOTTOM OF ITEM UNLESS INDICATED OTHERWISE ON DRAWINGS AFF EXISTING E SURFACE MOUNTED S EMERGENCY EM WEATHERPROOF WP NOT IN ELECTRICAL CONTRACT N.I.E.C. EQUIPMENT SUPPLIER E.S. GENERAL CONTRACTOR G.C. FIRE PROTECTION CONTRACTOR F.P.C. PLUMBING CONTRACTOR P.C. HVAC CONTRACTOR H.C. ELECTRICAL CONTRACTOR E.C. FOUR-WAY WALL SWITCH (46" M.H.). 4 THREE-WAY WALL SWITCH (46" M.H.). 3 SINGLE POLE WALL SWITCH (46" M.H.). MOTOR STARTER. DISCONNECT SWITCH. 20A-125V WEATHERPROOF DUPLEX RECEPTACLE, NEMA 5-20R, WITH GROUND FAULT CIRCUIT INTERRUPTER (18" M.H.), WITH TAYMAC #20310 STANDARD COVER, F F F F F F F F V V J J J F F F F F F L F L L F F F F F S J J J J J J J J J J J J J F F V L F L F F L F F L V V V V V J J J J S J J J J F F J J S F F L L L L L F F F J J J J OS F L L L F F L L F F F F F F F F F H H H V V V W SC SC SC SC SC SC SC SC SC SC SC F F F L F L F L F F F F F J J J J S J J J J F F F V W SC SC SC SC SC SC H S V DN UP DN UP DN DN UP UP F.E.C. F.E.C. AV AV AV PRJ AV TL1 6 AV AV TL1 6 AV AV AV AV AV 7 6 7 7 7 7 6 AV TL1 TL1 AV AC-2 SCALE: NONE E N ATS #1 N E G PER NEC 695 - CONNECTION LOCATED AHEAD OF MSB AND NOT WITHIN THE 'MSB' ENCLOSURE CABLES TO BE RUN BELOW THE BUILDING ENVELOPE PER NEC REQUIREMENTS. GENERATOR SET START AND STOP SIGNAL WIRING EXISTING SERVICE NEW NEW M SIZE CONDUIT GROUND SIZE FEEDER FEEDER SIZE: SPEC. REFERENCE NO.: NAMEPLATE UNIT NO. SWITCH OR SIZE BREAKER POLES TRIP SIZE VOLTAGE: DEMAND LOAD: CONNECTED LOAD: OVERCURRENT PROTECTION MAIN BUSSING: WIRE SIZE APPROX. CONNECTED KVA LOAD SEE NOTE NUMBER OF CONDUCTORS 3000A - - 120/208V, 3PH, 4WIRE 1 BOLTED PRESSURE MAIN - - - - MAIN SWITCHBOARD "MDP3" WITH GFP 2 3 4 5 6 Date: Scale Drawn By Checked By Project Number ARCHITECTURE PLANNING INTERIOR DESIGN STRUCTURAL ENGINEERING 424 East Fourth Street Cincinnati, Ohio 45202 w w w . c h a r c h i t e c t s . c o m tel: 513/241/4474 fax: 513/241/0081 ISSUANCES COMPUTER FILE 1400 West Dorothy Lane Dayton, Ohio 45409-1310 Tel: (937) 224-0861 Fax: (937) 224-5777 3417 South Sherman Drive Beech Grove, IN 46107 Tel: (317) 780-1555 Fax: (317) 780-6525 750 North Orleans, Suite 400 Chicago, IL 60610 Tel: (312) 944-8230 Fax: (312) 944-8297 117 East Washington Street, Suite 200 Indianapolis, IN 46204 Tel: (317) 637-2222 Fax: (317) 637-2260 1137 West Taylor St. Suite 316 Chicago, IL 60607 Tel: (312) 224-8460 Fax: (312) 224-8961 1025 N.Watery Ln. Brigham City, UT 84302 TEL: (453) 723-5000 FAX: (453) 538-5506 6622 Kingspointe Parkway Orlando, FL 33819 Tel: (407) 816-9400 Fax: (407) 816-9300 No. Description Date 8 06.10.08 11 CONSTRUCTION SET 08.01.08 7 06.04.08 6 05.22.08 5 ADDENDUM #2 05.16.08 4 PERMIT SET 04.25.08 3 CD 50% 03.14.08 2 DESIGN DEVELOPMENT 01.18.08 1 SCHEMATIC DESIGN 10.18.07 ADDENDUM #3 ADDENDUM #5 PERMIT SET 12 ASI6 12.23.08 PANEL: CONN. LOAD: MAINS: MOUNTING: DEMAND LOAD: VOLTAGE: REMARKS KVA BKR. BKR. KVA REMARKS 1 2 CKT. NO. 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 41 42 39 40 37 38 35 36 33 34 31 32 29 30 27 28 25 26 23 24 21 22 19 20 17 18 15 16 13 14 11 12 9 10 7 8 5 6 3 4 CKT. NO. 1 2 REMARKS KVA BKR. BKR. KVA REMARKS VOLTAGE: DEMAND LOAD: MOUNTING: MAINS: CONN. LOAD: PANEL: PANEL: CONN. LOAD: MAINS: MOUNTING: DEMAND LOAD: VOLTAGE: REMARKS KVA BKR. BKR. KVA REMARKS 1 2 CKT. NO. 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 41 42 39 40 37 38 35 36 33 34 31 32 29 30 27 28 25 26 23 24 21 22 19 20 17 18 15 16 13 14 11 12 9 10 7 8 5 6 3 4 CKT. NO. 1 2 REMARKS KVA BKR. BKR. KVA REMARKS VOLTAGE: DEMAND LOAD: MOUNTING: MAINS: CONN. LOAD: PANEL: ABBREVIATIONS: L-LIGHTS, R-RECEPTACLES, M-MOTORS, H-RESISTANCE HEAT, C-CONTROL, M.L.O.-MAIN LUGS ONLY, D.S.L.-DOUBLE SET OF LUGS, M.B.-MAIN BREAKER, L.C.-LOCKING CLIP ON BREAKER THL-1 13.3 KVA 200A SURFACE - 120/208V 3PH 4WIRE - 20/3 THL-2 4.60 KVA 200A SURFACE - 120/208V, 3PH, 4WIRE - - CKT#1 20/3 - CKT#2 CKT#1 - 20/3 20/3 - CKT#2 - - - - CKT#3 20/3 CKT#5 20/3 20/3 CKT#4 20/3 CKT#6 CKT#7 20/1 CKT#9 CKT#11 CKT#13 CKT#15 CKT#17 SPARE SPARE SPARE SPARE SPARE SPARE CKT#8 CKT#10 CKT#12 CKT#14 CKT#16 CKT#18 SPARE SPARE SPARE SPARE SPARE SPARE 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 PANEL: CONN. LOAD: MAINS: MOUNTING: DEMAND LOAD: VOLTAGE: REMARKS KVA BKR. BKR. KVA REMARKS 1 2 CKT. NO. 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 41 42 39 40 37 38 35 36 33 34 31 32 29 30 27 28 25 26 23 24 21 22 19 20 17 18 15 16 13 14 11 12 9 10 7 8 5 6 3 4 CKT. NO. 1 2 REMARKS KVA BKR. BKR. KVA REMARKS VOLTAGE: DEMAND LOAD: MOUNTING: MAINS: CONN. LOAD: PANEL: THL-6 17.25 KVA 200A SURFACE - 120/208V 3PH 4WIRE - 20/3 - - - CKT#1 20/3 - CKT#2 CKT#3 20/3 CKT#5 20/3 20/3 CKT#4 20/3 CKT#6 CKT#7 20/1 SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE CKT#8 SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 CKT#3 CKT#5 CKT#7 CKT#9 CKT#11 CKT#12 SPARE 20/1 20/1 20/1 20/1 20/1 20/1 20/1 CKT#4 CKT#6 CKT#8 CKT#10 CKT#12 CKT#14 SPARE 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE THL-3 11.5 KVA 200A SURFACE 120/208V 3PH 4WIRE THL-4 9.8 KVA 200A SURFACE 120/208V 3PH 4WIRE THL-5 14.4 KVA 200A SURFACE 120/208V 3PH 4WIRE CKT#1 20/3 20/3 CKT#2 CKT#3 20/3 CKT#5 20/3 20/3 CKT#4 20/3 CKT#6 CKT#7 20/1 SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE CKT#8 SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 CKT#1 20/3 20/3 CKT#2 CKT#3 20/3 CKT#5 20/3 20/3 CKT#4 20/3 CKT#6 CKT#7 20/1 CKT#9 CKT#11 CKT#13 CKT#15 SPARE SPARE SPARE SPARE SPARE SPARE SPARE CKT#8 CKT#10 CKT#12 CKT#14 CKT#16 SPARE SPARE SPARE SPARE SPARE SPARE SPARE 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 CKT#1 20/3 20/3 CKT#2 CKT#3 20/3 CKT#5 20/3 20/3 CKT#4 20/3 CKT#6 CKT#7 20/1 CKT#9 SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE CKT#8 CKT#10 SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 PANEL: CONN. LOAD: MAINS: MOUNTING: DEMAND LOAD: VOLTAGE: REMARKS KVA BKR. BKR. KVA REMARKS 1 2 CKT. NO. 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 - - - THL-7 10.4 KVA 200A SURFACE 120/208V 3PH 4WIRE CKT#1 20/3 20/3 CKT#2 CKT#3 20/3 CKT#5 20/1 20/3 CKT#4 20/1 CKT#6 CKT#7 20/1 CKT#9 CKT#11 CKT#13 CKT#15 SPARE SPARE SPARE SPARE SPARE SPARE SPARE CKT#8 CKT#10 CKT#12 CKT#14 CKT#16 SPARE SPARE SPARE SPARE SPARE SPARE SPARE 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 SPARE SPARE SPARE SPARE 20/1 20/1 20/1 20/1 41 42 39 40 37 38 35 36 33 34 31 32 29 30 27 28 25 26 23 24 21 22 19 20 17 18 15 16 13 14 11 12 9 10 7 8 5 6 3 4 CKT. NO. 1 2 REMARKS KVA BKR. BKR. KVA REMARKS VOLTAGE: DEMAND LOAD: MOUNTING: MAINS: CONN. LOAD: PANEL: - 2.50 2.50 RP3 41.7 KVA 200A SURFACE 120/208V 3PH 4WIRE WINCH#1 20/3 20/3 WINCH#2 WINCH#3 20/3 WINCH#5 20/3 20/3 WINCH#4 20/3 WINCH#6 CSL PANEL SPARE SPARE STAGE LIFT STAGE LIFT SPARE 20/1 20/1 20/1 20/1 20/1 20/1 2.50 2.50 2.50 2.50 WINCH#7 2.50 20/3 20/3 2.50 WINCH#8 WINCH#9 2.50 20/3 20/3 2.50 TRACK WINCH CTRL 5.50 20/3 20/3 5.50 TRACK CTRL 1.90 1.90 1.90 41 42 39 40 37 38 35 36 33 34 31 32 29 30 27 28 25 26 23 24 21 22 19 20 17 18 15 16 13 14 11 12 9 10 7 8 5 6 3 4 CKT. NO. 1 2 REMARKS KVA BKR. BKR. KVA REMARKS VOLTAGE: DEMAND LOAD: MOUNTING: MAINS: CONN. LOAD: PANEL: 72.9 KVA 3.35 RP6 81.00 KVA 300A SURFACE 120/208V 3PH 4WIRE VAV-1 35/3 35/3 30/3 45/3 20/3 25/3 SPARE SPARE SPARE SPARE SPARE SPARE 20/1 20/1 20/1 20/1 20/1 20/1 41 42 39 40 37 38 35 36 33 34 31 32 29 30 27 28 25 26 23 24 21 22 19 20 17 18 15 16 13 14 11 12 9 10 7 8 5 6 3 4 CKT. NO. 1 2 REMARKS KVA BKR. BKR. KVA REMARKS VOLTAGE: DEMAND LOAD: MOUNTING: MAINS: CONN. LOAD: PANEL: 83.25 KVA RP7 92.5 KVA 300A SURFACE 120/208V 3PH 4WIRE 20/3 20/3 20/3 20/3 20/3 20/3 SPARE SPARE SPARE 20/1 20/1 20/1 20/1 20/1 20/1 20/3 20/3 20/3 20/3 20/1 VAV-2 VAV-3 VAV-5 VAV-4 VAV-6 VAV-7 VAV-8 VAV-9 VAV-10 VAV-11 VAV-12 20/3 50/3 20/3 20/3 20/3 20/3 3.35 3.35 3.35 3.35 3.35 3.0 1.0 3.0 1.0 3.0 1.0 4.33 2.33 4.33 2.33 4.33 2.33 2.0 4.66 2.0 4.66 2.0 4.66 0.66 1.33 0.66 1.33 0.66 1.33 0.66 0.33 0.66 0.33 0.66 0.33 - - - - - - VAV-13 0.33 VAV-14 VAV-15 UH-1 UH-2 UH-3 CUH-2 CUH-1 CUH-4 CUH-3 UH-3 SPARE 1.00 1.33 3.35 2.50 3.35 3.35 5.00 5.00 5.00 - - - - SPARE - - - - - 20/1 20/1 SPARE SPARE SPARE SPARE 0.33 1.00 1.33 3.35 2.50 3.35 3.35 5.00 5.00 5.00 0.33 1.00 1.33 3.35 2.50 3.35 3.35 5.00 5.00 5.00 3.35 20/3 3.35 3.35 Date: Scale Drawn By Checked By Project Number ARCHITECTURE PLANNING INTERIOR DESIGN STRUCTURAL ENGINEERING 424 East Fourth Street Cincinnati, Ohio 45202 w w w . c h a r c h i t e c t s . c o m tel: 513/241/4474 fax: 513/241/0081 ISSUANCES COMPUTER FILE 1400 West Dorothy Lane Dayton, Ohio 45409-1310 Tel: (937) 224-0861 Fax: (937) 224-5777 3417 South Sherman Drive Beech Grove, IN 46107 Tel: (317) 780-1555 Fax: (317) 780-6525 750 North Orleans, Suite 400 Chicago, IL 60610 Tel: (312) 944-8230 Fax: (312) 944-8297 117 East Washington Street, Suite 200 Indianapolis, IN 46204 Tel: (317) 637-2222 Fax: (317) 637-2260 1137 West Taylor St. Suite 316 Chicago, IL 60607 Tel: (312) 224-8460 Fax: (312) 224-8961 1025 N.Watery Ln. Brigham City, UT 84302 TEL: (453) 723-5000 FAX: (453) 538-5506 6622 Kingspointe Parkway Orlando, FL 33819 Tel: (407) 816-9400 Fax: (407) 816-9300 No. Description Date 8 06.10.08 11 CONSTRUCTION SET 08.01.08 7 06.04.08 6 05.22.08 5 ADDENDUM #2 05.16.08 4 PERMIT SET 04.25.08 3 CD 50% 03.14.08 2 DESIGN DEVELOPMENT 01.18.08 1 SCHEMATIC DESIGN 10.18.07 ADDENDUM #3 ADDENDUM #5 PERMIT SET 12 ASI6 12.23.08 13 PERMIT RE-SUBMISSION 1.28.09 2/3/2009 4:35:29 PM \\DAYDATA1\TEAMDATA\l600\2007-06019\DRAWINGS\2007-06019-Central.rvt E403 PANELBOARD SCHEDULES New Worship Center Checker Author 05-22-08 2007-06019 13 PERMIT RE-SUBMISSION 1.28.09 2/3/2009 4:32:25 PM \\DAYDATA1\TEAMDATA\l600\2007-06019\DRAWINGS\2007-06019-Central.rvt E402 PANELBOARD SCHEDULES New Worship Center Checker Author 05-22-08 2007-06019 Mfg. / Type Modifications Amps RMS. Sym. -- -- -- Phase A Phase B Phase C Total VA 15380 VA 16300 VA 18600 VA 50280 VA Load Name Trip Poles Ckt. No. A B C Ckt. No. Poles Trip Load Name Power 20 A 1 1 1000 VA / 1000 VA 2 1 20 A Power Power 20 A 1 3 1000 VA / 1000 VA 4 1 20 A Power Power Room 016 20 A 1 5 1400 VA / 500 VA 6 1 20 A Power Power GREEN ROOM 020 20 A 1 7 180 VA / 1400 VA 8 1 20 A Power RECORDING STUDIO 029 Power 20 A 1 9 1400 VA / 1400 VA 10 1 20 A Power Power 20 A 1 11 1400 VA / 1500 VA 12 1 20 A 20 A 1 13 1500 VA / 1500 VA 14 1 20 A 20 A 1 15 1500 VA / 1500 VA 16 1 20 A 17 0 VA / 1500 VA 18 1 20 A 20 A 1 19 1500 VA / 2100 VA 20 2 20 A Power Power 20 A 2 21 2100 VA / 2100 VA 22 -- -- 23 2100 VA / 2100 VA 24 2 20 A Power Power 20 A 1 25 1600 VA / 2100 VA 26 -- 27 28 Power 20 A 1 29 1600 VA / 1200 VA 30 1 20 A Power Power 20 A 1 31 800 VA / 0 VA 32 -- 33 0 VA / 700 VA 34 1 20 A Power PLATFORM 119 Power RECORDING STUDIO 029 20 A 1 35 700 VA / 1000 VA 36 1 -- Power Power PLATFORM 119 20 A 1 37 700 VA / 0 VA 38 -- Power SIDE PLATFORM 120 20 A 2 39 3600 VA / 0 VA 40 2 20 A Power SIDE PLATFORM 117 -- 41 3600 VA / 0 VA 42 -- Mount Enclosure Location Surface Type 1 CORR. C-005 Panel Voltage Phase Wires Mains RPAV1 120 V / 208 V Three Phase 4 Wires 200 A Mfg. / Type Modifications Amps RMS. Sym. -- -- -- Phase A Phase B Phase C Total VA 1440 VA 1000 VA 0 VA 2440 VA Load Name Trip Poles Ckt. No. A B C Ckt. No. Poles Trip Load Name Power 20 A 1 1 230 VA / 0 VA 2 3 4 5 6 7 0 VA / 750 VA 8 1 20 A EF-7 Power VEST. 107 20 A 1 9 500 VA / 500 VA 10 1 20 A Power WOMENS' REST RM. 111 Power 20 A 1 11 12 1 20 A Power 20 A 1 13 230 VA / 230 VA 14 1 20 A Power MECH. ROOM 020 20 A 1 15 16 1 20 A Power WORKSHOP 116 Power STORAGE 115 20 A 1 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 Mount Enclosure Location Surface Type 1 TRAP ROOM 033 Panel Voltage Phase Wires Mains RP5 120 V / 208 V Three Phase 4 Wires 200 A Mfg. / Type Modifications Amps RMS. Sym. -- -- -- Phase A Phase B Phase C Total VA 19620 VA 22320 VA 21200 VA 63140 VA Load Name Trip Poles Ckt. No. A B C Ckt. No. Poles Trip Load Name 20 A 1 1 1800 VA / 1800 VA 2 1 20 A 20 A 1 3 1800 VA / 1800 VA 4 1 20 A 20 A 1 5 1800 VA / 1800 VA 6 1 20 A 20 A 1 7 1800 VA / 1800 VA 8 1 20 A 20 A 1 9 1800 VA / 1800 VA 10 1 20 A 20 A 1 11 1800 VA / 1800 VA 12 1 20 A 20 A 1 13 1800 VA / 1800 VA 14 1 20 A 20 A 1 15 1800 VA / 1800 VA 16 1 20 A 20 A 1 17 1800 VA / 1800 VA 18 1 20 A 20 A 1 19 1800 VA / 1800 VA 20 1 20 A 20 A 1 21 1800 VA / 1800 VA 22 1 20 A 20 A 1 23 1800 VA / 1800 VA 24 1 20 A Power VIDEO EDIT 027 20 A 1 25 540 VA / 540 VA 26 1 20 A Power VIDEO EDIT 027 Power 20 A 1 27 360 VA / 360 VA 28 1 20 A Power Power 20 A 1 29 1400 VA / 1800 VA 30 1 20 A 31 0 VA / 540 VA 32 1 20 A Power VIDEO CONTROL 022 20 A 1 33 1800 VA / 1800 VA 34 1 20 A 20 A 1 35 1800 VA / 1800 VA 36 1 20 A 20 A 1 37 1800 VA / 1800 VA 38 1 20 A 20 A 1 39 1800 VA / 1800 VA 40 1 20 A 41 42 Mount Enclosure Location Surface Type 1 CORR. C-005 Panel Voltage Phase Wires Mains RPAV4 120 V / 208 V Three Phase 4 Wires 100 A Mfg. / Type Modifications Amps RMS. Sym. -- -- -- Phase A Phase B Phase C Total VA 21400 VA 18280 VA 17700 VA 57380 VA Load Name Trip Poles Ckt. No. A B C Ckt. No. Poles Trip Load Name Power 20 A 1 1 1200 VA / 1800 VA 2 1 20 A Power 3 0 VA / 1080 VA 4 1 20 A Power Power 20 A 1 5 700 VA / 2100 VA 6 2 20 A Power Power 20 A 2 7 2100 VA / 2100 VA 8 -- 9 2100 VA / 2100 VA 10 2 20 A Power Power 20 A 2 11 2100 VA / 2100 VA 12 -- 13 2100 VA / 2100 VA 14 2 20 A Power Power 20 A 2 15 2100 VA / 2100 VA 16 -- 17 2100 VA / 2100 VA 18 2 20 A Power Power 20 A 2 19 2100 VA / 2100 VA 20 -- 21 2100 VA / 2100 VA 22 2 20 A Power Power 20 A 2 23 2100 VA / 2100 VA 24 -- 25 2100 VA / 2100 VA 26 2 20 A Power Power 20 A 1 27 700 VA / 2100 VA 28 Power 20 A 1 29 700 VA / 700 VA 30 1 20 A Power Power 20 A 1 31 700 VA / 900 VA 32 1 20 A Power Power 20 A 1 33 900 VA / 900 VA 34 1 20 A Power Power 20 A 1 35 900 VA / 0 VA 36 37 38 39 40 41 42 Mount Enclosure Location Surface Type 1 CORR. C-005 Panel Voltage Phase Wires Mains RPAV3 120 V / 208 V Three Phase 4 Wires 100 A Mfg. / Type Modifications Amps RMS. Sym. -- -- -- Phase A Phase B Phase C Total VA 7400 VA 9800 VA 8000 VA 25200 VA Load Name Trip Poles Ckt. No. A B C Ckt. No. Poles Trip Load Name Power BALCONY-1 200 20 A 1 1 1400 VA / 400 VA 2 1 20 A Power BALCONY-1 200 Power BALCONY-1 200 20 A 1 3 1400 VA / 700 VA 4 1 20 A Power SECOND BALCONY 300 5 0 VA / 2100 VA 6 2 20 A Power PROJECTION ROOM 221 Power PROJECTION ROOM 221 20 A 2 7 2100 VA / 2100 VA 8 -- 9 2100 VA / 2100 VA 10 2 20 A Power PROJECTION ROOM 221 Power BALCONY-1 200 20 A 1 11 800 VA / 2100 VA 12 13 14 Power BALCONY-1 200 20 A 1 15 800 VA / 1200 VA 16 1 20 A Power BALCONY-1 200 Power BALCONY-1 200 20 A 1 17 800 VA / 700 VA 18 1 20 A 20 A 1 19 700 VA / 700 VA 20 1 20 A Power SECOND BALCONY 300 20 A 1 21 800 VA / 700 VA 22 1 20 A Power SECOND BALCONY 300 Power SECOND BALCONY 300 20 A 1 23 700 VA / 800 VA 24 1 20 A Power SECOND BALCONY 300 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 Mount Enclosure Location Surface Type 1 CORR. C-005 Panel Voltage Phase Wires Mains RPAV2 120 V / 208 V Three Phase 4 Wires 200 A Mfg. / Type Modifications Amps RMS. Sym. -- -- -- Phase A Phase B Phase C Total VA 16560 VA 15120 VA 15120 VA 46800 VA Load Name Trip Poles Ckt. No. A B C Ckt. No. Poles Trip Load Name SIDE PLATFORM 120 20 A 1 1 1800 VA / 1800 VA 2 1 20 A SIDE PLATFORM 120 SIDE PLATFORM 120 20 A 1 3 1800 VA / 1800 VA 4 1 20 A SIDE PLATFORM 120 SIDE PLATFORM 120 20 A 1 5 1800 VA / 1800 VA 6 1 20 A SIDE PLATFORM 120 SIDE PLATFORM 120 20 A 1 7 1800 VA / 1800 VA 8 1 20 A SIDE PLATFORM 120 SIDE PLATFORM 120 20 A 1 9 1800 VA / 1800 VA 10 1 20 A SIDE PLATFORM 120 SIDE PLATFORM 120 20 A 1 11 1800 VA / 1800 VA 12 1 20 A SIDE PLATFORM 120 SIDE PLATFORM 120 20 A 1 13 1800 VA / 1800 VA 14 1 20 A SIDE PLATFORM 120 SIDE PLATFORM 120 20 A 1 15 1800 VA / 1800 VA 16 1 20 A SIDE PLATFORM 120 SIDE PLATFORM 120 20 A 1 17 1800 VA / 1800 VA 18 1 20 A SIDE PLATFORM 120 SIDE PLATFORM 120 20 A 1 19 1800 VA / 1800 VA 20 1 20 A SIDE PLATFORM 120 SIDE PLATFORM 120 20 A 1 21 1800 VA / 1800 VA 22 1 20 A SIDE PLATFORM 120 SIDE PLATFORM 120 20 A 1 23 1800 VA / 1800 VA 24 1 20 A SIDE PLATFORM 120 SIDE PLATFORM 120 20 A 1 25 1800 VA / 360 VA 26 1 20 A Power Power 20 A 1 27 360 VA / 360 VA 28 1 20 A Power Power 20 A 1 29 360 VA / 360 VA 30 1 20 A Power 31 32 33 34 35 36 37 38 39 40 41 42 Mount Enclosure Location Surface Type 1 CORR. C-005 Panel Voltage Phase Wires Mains RPAV5 120 V / 208 V Three Phase 4 Wires 100 A Mfg. / Type Modifications Amps RMS. Sym. -- -- -- Phase A Phase B Phase C Total VA 6900 VA 8100 VA 7200 VA 22200 VA Load Name Trip Poles Ckt. No. A B C Ckt. No. Poles Trip Load Name Room 033 20 A 1 1 540 VA / 360 VA 2 1 20 A TRAP ROOM 033 20 A 1 3 900 VA / 0 VA 4 5 0 VA / 900 VA 6 1 20 A TRAP ROOM 033 20 A 1 7 900 VA / 900 VA 8 1 20 A TRAP ROOM 033 20 A 1 9 900 VA / 2100 VA 10 2 20 A Power PLATFORM 119 Power PLATFORM 119 20 A 2 11 2100 VA / 2100 VA 12 -- 13 2100 VA / 2100 VA 14 2 20 A Power PLATFORM 119 Power PLATFORM 119 20 A 2 15 2100 VA / 2100 VA 16 -- 17 2100 VA / 0 VA 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 Mount Enclosure Location Surface Type 1 CORR. C-005 Panel Voltage Phase Wires Mains RPAV6 120 V / 208 V Three Phase 4 Wires 100 A SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPARE 20 A 1 1 20 A SPARE SPARE 20 A 1 1 20 A SPARE SPARE 20 A 1 1 20 A SPARE SPARE 20 A 1 1 20 A SPARE SPARE 20 A 1 1 20 A SPARE BATTERY CHARGER 20 A 1 1 20 A BLOCK HEATER SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPACE SPARE 20 A 1 1 20 A SPARE SPARE 20 A 1 1 20 A SPARE SPARE 20 A 1 1 20 A SPARE SPARE 20 A 1 1 20 A SPARE SPARE 20 A 1 1 20 A SPARE SPARE 20 A 1 1 20 A SPARE SPARE 20 A 1 1 20 A SPARE SPARE 20 A 1 1 20 A SPARE SPARE 20 A 1 1 20 A SPARE SPARE 20 A 1 1 20 A SPARE SPARE 20 A 1 1 20 A SPARE SPARE 20 A 1 1 20 A SPARE SPARE 20 A 1 1 20 A SPARE SPARE 20 A 1 1 20 A SPARE SPARE 20 A 1 1 20 A SPARE SPARE 20 A 1 1 20 A SPARE SPARE 20 A 1 1 20 A SPARE SPARE 20 A 1 1 20 A SPARE SPARE 20 A 1 1 20 A SPARE SPARE 20 A 1 1 20 A SPARE SPARE 20 A 1 1 20 A SPARE SPARE 20 A 1 1 20 A SPARE SPARE 20 A 1 1 20 A SPARE SPARE 20 A 1 1 20 A SPARE SPARE 20 A 1 1 20 A SPARE Mfg. / Type Modifications Amps RMS. Sym. -- -- -- Phase A Phase B Phase C Total VA 39933 VA 34333 VA 39933 VA 114200 VA Load Name Trip Poles Ckt. No. A B C Ckt. No. Poles Trip Load Name AC-2 125 A 3 1 11667 VA / 11667 VA 2 3 125 A AC-1 -- 3 11667 VA / 11667 VA 4 -- -- 5 11667 VA / 11667 VA 6 -- AC-3 45 A 2 7 3500 VA / 2000 VA 8 3 30 A MECH. ROOM 020 -- 9 3500 VA / 2000 VA 10 -- CU-3 40 A 2 11 2100 VA / 2000 VA 12 -- -- 13 2100 VA / 0 VA 14 2 40 A CU-4 AC-4 45 A 2 15 3500 VA / 0 VA 16 -- -- 17 3500 VA / 2000 VA 18 3 -- CU-1 40 A 3 19 7000 VA / 2000 VA 20 -- -- 21 0 VA / 2000 VA 22 -- -- 23 0 VA / 7000 VA 24 3 40 A CU-2 25 26 -- 27 28 -- 29 30 31 32 33 34 35 36 37 38 39 40 41 42 Mount Enclosure Location Surface Type 1 TRAP ROOM 033 Panel Voltage Phase Wires Mains RP4 120 V / 208 V Three Phase 4 Wires 200 A 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 SERVICE SPD ATS #1 ROOF TOP UNIT #1 ROOF TOP UNIT #2 ROOF TOP UNIT #3 ROOF TOP UNIT #4 ELEVATOR STAGE LIFT PANEL "RP1" PANEL "RP2" PANEL "RP3" PANEL "RP4" PANEL "THL1" PANEL "THL2" PANEL "THL3" PANEL "THL4" PANEL "THL5" PANEL "THL6" PANEL "THL7" TRANSFORMER DP #1 DP #2 PANEL "LP2" 30 31 32 33 34 PANEL "LP1" PANEL "EP" AC-2 SPARE SPARE 30 83 75 83 75 83 82.5 35 30 11 40 40 42 48 60 100 250 250 250 250 250 300 125 150 50 200 200 200 200 200 200 200 200 200 200 200 800 200 200 200 200 200 100 125 200 200 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 - - - 60 150 250 250 250 250 250 300 125 150 50 200 200 200 200 200 200 200 200 200 200 200 800 200 200 200 200 200 100 125 200 200 3 4 3 3 3 4 3 3 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 6 2/0 4/0 4/0 4/0 350 1 3/0 6 3/0 3/0 3/0 3/0 250 250 250 250 250 250 250 250 250 250 3/0 3/0 10 3 4 4 4 4 6 6 10 6 6 6 6 3 3 3 3 3 3 3 3 3 3 6 6 2 SETS - 3 #400 AND 1 #1/0 IN 3"C EACH SET 100 8 SETS - 4#600 IN 3.5"C CONDUIT EACH SET +(2) SPARE 3.5" CONDUITS 0.75 2.0 2.5 2.5 2.5 - 3 1.5 2.0 1.5 2.5 2.5 2.5 2.5 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0 2.5 2.5 GFP SPD ELEV. SERVICE 3000A, 208/120V-3PH-4W SWBD METERING POWER MODULE UTILITY PRIMARY ELECTRICAL FEEDER POWER COMPANY PAD MOUNTED TRANSFORMER 12.47 KV/208/120V-3PH-4W ELEC. METER PER UTILITY REQUIREMENT TRANSITION CABINET TO EXISTING SWITCHBOARD 'MDP' TO EXISTING SWITCHBOARD 'MDP2' EXISTING AC-1 4 BUSSMANN SWITCH 30HP STAGE LIFT 10HP STARTER CABINET EMERGENCY GENERATOR WITH AUTO. TRANFER SWITCH FIRE PUMP CONTROLLER PUMP FIRE 208/120V STAND-BY 60KW NATURAL GAS 400/300 B B A B (FP1) 110/3 100/3 100/3P, 4 WIRE 30HP EBP RPAV1 RPAV2 RPAV3 RPAV4 RPAV5 RPAV6 RP1 2 3 5 6 7 8 9 10 11 12 13 14 RP2 15 RP3 16 RP4 17 THL1 18 THL2 19 THL3 20 THL4 21 THL5 22 THL6 23 24 33 32 31 LP1 30 LP2 29 28 DP#1 27 DP#2 26 25 11 10 9 8 7 6 5 4 3 2 1 PRIMARY : 208V, 3Ph., Delta SECONDARY: 208V, 3 Ph., Wye ISOLATION TRANSFORMER FOR A/V APPLICATION ONLY SPARE SPARE SPARE SPARE 1 60 100 250 250 250 250 250 300 300 125 150 50 200 200 200 200 200 200 200 200 200 200 200 125 200 200 200 200 200 200 800 225KVA 100 100 200 200 200 200 200 200 200 200 800A, 208/120V-3PH-4W DP#3 THL7 RP5 34 SPARE 200 (OPTIO 9) (OPTIO 9) (CAPIO) (PLUS) A PANEL "RP5" 48 200 3 200 4 3/0 6 2.5 35 DP #3 1 2 3 4 5 6 7 8 9 10 11 12 13 36 35 34 33 10757 8163 8163 8163 8163 8163 8163 21 22 23 24 25 26 27 28 29 30 31 32 29445 29445 10044 10044 10044 13454 13454 13454 20 19 18 17 16 15 14 13 12 11 10 13454 9 13454 8 13454 5 23096 7 23096 6 23096 4 27158 3 27158 2 41894 1 48331 AVAILABLE SHORT CIRCUIT AMPS POINT REF. DESCRIPTION SECONDARY - SERVICE TRANSFORMER MAIN SWITCHBOARD 'MDP3' PANEL 'RP2' PANEL 'RP3' PANEL 'RP4' PANEL 'RP5' PANEL 'THL1' PANEL 'THL2' PANEL 'RP1' PANEL 'THL3' PANEL 'THL4' PANEL 'THL5' PANEL 'THL6' PANEL 'THL7' DIMMER RACK DP#3 XFMR 225KVA PRIMARY DIMMER RACK DP#2 DIMMER RACK DP#1 PANEL 'LP2' PANEL 'LP1' XFMR 225KVA SECONDARY PANEL 'RPAV6' PANEL 'RPAV5' PANEL 'RPAV4' PANEL 'RPAV3' PANEL 'RPAV2' PANEL 'RPAV1' 13454 35824 9702 DISTRIBUTION PANEL 'DPL1' PANEL 'EP' 27158 29 EXISTING EXISTING EXISTING 32 100 EP TRANSFER SWITCH TO RELAY LOADS TO DIMMING LOADS 4 1 8 1.5 EMERGENCY UC700 TRANSFER SWITCH EMERGENCY UC700 A - 4#2/0, 1#3 IN 2" C. B - 3#2/0, 1#3 IN 2" C. ROOF TOP UNIT #5 PANEL "RP6" PANEL "RP7" AC-1 81 300 3 300 3 4/0 4 2.5 35 3 1 6 1.5 14 21 19 14 18 RP6 RP7 AC-2 EP 29 20 19 18 17 16 15 14 21 22 28 27 26 25 24 23 225 4 350 4 3 3 4/0 4 2.5 "THL1" THRU "THL7" TOTAL RTU-1 RTU-2 RTU-3 RTU-4 RTU-5 125 ELECTRIC SINGLE-LINE DISTRIBUTION DIAGRAM FAULT CURRENT SCHEDULE MAIN SWITCHBOARD 'MDP3' DISTRIBUTION PANEL "DPL1 Date: Scale Drawn By Checked By Project Number ARCHITECTURE PLANNING INTERIOR DESIGN STRUCTURAL ENGINEERING 424 East Fourth Street Cincinnati, w w w . c h a r c h Ohio i t e c t s . 45202 c o m tel: 513/241/4474 fax: 513/241/0081 ISSUANCES COMPUTER FILE 1400 West Dorothy Lane Dayton, Ohio 45409-1310 Tel: (937) 224-0861 Fax: (937) 224-5777 3417 South Sherman Drive Beech Grove, IN 46107 Tel: (317) 780-1555 Fax: (317) 780-6525 750 North Orleans, Suite 400 Chicago, IL 60610 Tel: (312) 944-8230 Fax: (312) 944-8297 117 East Washington Street, Suite 200 Indianapolis, IN 46204 Tel: (317) 637-2222 Fax: (317) 637-2260 1137 West Taylor St. Suite 316 Chicago, IL 60607 Tel: (312) 224-8460 Fax: (312) 224-8961 1025 N.Watery Ln. Brigham City, UT 84302 TEL: (453) 723-5000 FAX: (453) 538-5506 6622 Kingspointe Parkway Orlando, FL 33819 Tel: (407) 816-9400 Fax: (407) 816-9300 10.18.07 No. Description Date 1 SCHEMATIC DESIGN 2 3 4 5 6 7 8 11 DESIGN DEVELOPMENT 01.18.08 CD 50% 03.14.08 PERMIT SET 04.25.08 ADDENDUM #2 05.16.08 ADDENDUM #3 05.22.08 ADDENDUM #5 06.04.08 PERMIT SET 06.10.08 CONSTRUCTION SET 08.01.08 12 ASI6 12.23.08 13 PERMIT RE-SUBMISSION 1.28.09 2/3/2009 4:29:28 PM \\DAYDATA1\TEAMDATA\l600\2007-06019\DRAWINGS\2007-06019-Central.rvt E400 SINGLE-LINE DISTRIBUTION DIAGRAM New Worship Center Checker Author 05-22-08 2007-06019 AC-1 2 1 3 GF R V1 AV RPAV2 - 1 RPAV2 - 2 RPAV2 - 3 A G E1 A C E1 A G E1 A G E1 A G E1 RPAV2 - 6,8 RPAV2 - 7,9 RPAV2 - 10,12 E F1 E F1 E F1 PRJ PRJ A C1 A A A A C C1 A A C C1 RPAV2 - 11 RPAV2 - 15 RPAV2 - 16 RPAV2 - 17 RP1 - 5 RP1 - 6 RP1 - 7 RP1 - 8 RP1 - 9 5 MDP3 - 16 EP - 16 EP - 17 RP5 - 11 EF-4 EF-3 RP5 - 12 RP5 - 13 GF/WP RTU-5 RP5 - 14 GF/WP RP4 - 1,3,5 RP4 - 2,4,6 4 4 4 6 (TYP.) A A A A A A C1 7 7 7 221 200 S-21 S-22 S-23 203 201 204 202 S-24 8 8 10 11 7 10 11 9 9 12 R R 13 13 WP WP 7 10 11 RTU-1 MDP3-8 MDP3-5 RTU-2 GF/WP WP RP5 - 1 MDP3-4 Date: Scale Drawn By Checked By Project Number ARCHITECTURE PLANNING INTERIOR DESIGN STRUCTURAL ENGINEERING 424 East Fourth Street Cincinnati, w w w . c h a r c h Ohio i t e c t s . 45202 c o m tel: 513/241/4474 fax: 513/241/0081 ISSUANCES COMPUTER FILE 1400 West Dorothy Lane Dayton, Ohio 45409-1310 Tel: (937) 224-0861 Fax: (937) 224-5777 3417 South Sherman Drive Beech Grove, IN 46107 Tel: (317) 780-1555 Fax: (317) 780-6525 750 North Orleans, Suite 400 Chicago, IL 60610 Tel: (312) 944-8230 Fax: (312) 944-8297 117 East Washington Street, Suite 200 Indianapolis, IN 46204 Tel: (317) 637-2222 Fax: (317) 637-2260 1137 West Taylor St. Suite 316 Chicago, IL 60607 Tel: (312) 224-8460 Fax: (312) 224-8961 1025 N.Watery Ln. Brigham City, UT 84302 TEL: (453) 723-5000 FAX: (453) 538-5506 6622 Kingspointe Parkway Orlando, FL 33819 Tel: (407) 816-9400 Fax: (407) 816-9300 10.18.07 No. Description Date 1 SCHEMATIC DESIGN 2 3 4 5 6 7 8 11 DESIGN DEVELOPMENT 01.18.08 CD 50% 03.14.08 PERMIT SET 04.25.08 ADDENDUM #2 05.16.08 ADDENDUM #3 05.22.08 ADDENDUM #5 06.04.08 PERMIT SET 06.10.08 CONSTRUCTION SET 08.01.08 12 ASI6 12.23.08 13 PERMIT RE-SUBMISSION 1.28.09 1/8" = 1'-0" 2/3/2009 4:29:28 PM \\DAYDATA1\TEAMDATA\l600\2007-06019\DRAWINGS\2007-06019-Central.rvt E302 BALCONY ONE - POWER PLAN New Worship Center Checker Author 05-22-08 2007-06019 1/8" = 1'-0" 1 POWER & SYSTEMS - BALCONY ONE - NEW WORK GENERAL NOTES A E.C. TO COORDINATE WITH A/V DRAWINGS: AV201, AV211, AV202, AV212, AV203, AV213, AV204, AV205, AV215, AV251, AV252, AV253, AV301, AV302 FOR BOX TYPE, MOUNTING HEIGHT, EXACT LOCATION FOR A/V DEVICES AND A/V EQUIPMENT AND ANY ADDITIONAL ELECTRICAL REQUIREMENTS PRIOR TO ROUGH-IN. A/V CONSULTANT: CRAIG COMPTON PRO-SOUND PH: 407-816-9400 E-MAIL: CCOMPTON@PROSOUND.NET PLAN NOTES 1 PROVIDE 240V, 1P, 30A FUSED DISCONNECT WITH 20A FUSE AND 120V, 20A DEDICATED CIRCUIT FOR ELEVATOR CAB LIGHT. PROVIDE WIRING TO ELEVATOR CONTROLLER PER MANUFACTURER'S REQUIREMENTS. 2 PROVIDE BUSSMAN POWER MODULE SWITCH WITH SHUNT-TRIP CONTROL. TRANSFORMER WITH FUSES AND BLACKS, FIRE SAFETY INTERFACE RELAY, MECHANICALLY INTERLOCKED AUXILIARY CONTACT, FIRE ALARM VOLTAGE MONITORING RELAY IN NEMA 1 ENCLOSURE. PROVIDE ELEVATOR POWER CIRCUIT #MDP3-_ (208V, 3PH, 60HZ, 30HP). COORDINATE EXACT SWITCH SIZE WITH ELEVATOR EQUIPMENT SUPPLIER PRIOR TO ROUGH-IN. 3 PROVIDE 120V, 20A GFCI RECEPTACLE IN THE ELEVATOR EQUIPMENT ROOM (46"M.H.). 4 PROVIDE RECEPTACLE WITH NEMA CONFIGURATION - 6-20R. COORDINATE EXACT REQUIREMENTS WITH A/V CONSULTANT PRIOR TO ROUGH-IN. 5 SINGLE GANG BOX WITH 3/4" CONDUIT TO "CONTROL EQUIPMENT RACK" IN CATWALK. PROVIDE BLANK COVER PLATE. DATA OUTLET AND CABLE BY OTHERS. INTENT IS TO MOUNT BOX ON FACE OF BALCONY FLOOR. COORDINATE EXACT LOCATION AND MOUNTING HEIGHT WITH LIGHTING CONSULTANT / SYSTEM INTEGRATOR PRIOR TO ROUGH-IN. 6 INTENT IS TO MOUNT SPEAKERS CENTERED WITH BEAM (TYPICAL OF 5 SPEAKERS). COORDINATE EXACT LOCATION WITH A/V CONSULTANT PRIOR TO ROUGH-IN. 7 PROVIDE DUCT MOUNTED SMOKE DETECTOR ON RETURN DUCT AND INTERFACE WITH FACP TO SHUT-DOWN UNIT UPON ALARM. 8 PROVIDE SINGLE GANG BOX WITH 3/4" CONDUIT TO THE SERVER ROOM. PROVIDE A BLANK COVER PLATE. RJ45 OUTLET AND CAT5 CABLING BY OTHERS. OVERALL LENGTH SHOULD NOT EXCEED 285'. 9 AIR CONDITIONING UNIT. MOUNT FUSED DISCONNECT ON THE UNIT AND WIRE PER REQUIREMENTS. SEE HVAC DRAWINGS FOR LOCATION AND MOUNTING ARRANGEMENT. 10 ROOFTOP UNIT. PROVIDE FUSED DISCONNECT NEMA 3R AND WIRE PER REQUIREMENTS. COORDINATE LOCATION WITH HVAC DRAWINGS. 11 PROVIDE GFI/WP RECEPTACLE AND VAPORPROOF APPLETON LIGHT FIXTURE FOR ROOFTOP UNIT. PROVIDE WEATHERPROOF LIGHT SWITCH. 12 EXHAUST FAN. PROVIDE ELECTRICAL ROUGH-IN AND FINAL CONNECTIONS. COORDINATE WITH HVAC DRAWINGS FOR LOCATION AND CONTROLS. 13 CONDUITS FROM MAIN LEVEL, BOOTH, 1ST BALCONY, AND 2ND BALCONY ARE TO BE ROUTED THRU THE CHASE SPACE AVAILABLE AT THE BACK OF THE NEW WORSHIP CENTER NEAR THE REST ROOMS, STAIRS, ETC., DOWN BELOW THE UNDERFLOOR DUCT WORK BELOW THE SEATING IN THE MAIN LEVEL TO THE STAGE RACK LOCATION, RACK LOCATION IN THE PIT LEVEL, ELECTRICAL PANELS, SWITCHBOARD "MDP3", ETC. E.C. TO COORDINATE WITH PLUMBING AND HVAC CONTRACTORS PRIOR TO INSTALLING THE CONDUITS TO PREVENTCONFLICTS BETWEEN THE TRADES. A/V CONDUIT NOTES A (1) 3/4"C. B (3) 1"C. C (1) 1"C. D (1) 2"C. E (1) 1-1/2"C. F (3) 1-1/2"C. G (2) 1"C. H (2) 2"C. J (2) 4"C. K (3) 4"C. L (3) 2"C. M (1) 1/2"C. N (2) 1-1/4"C. O (2) 1-1/2"C. A1 TO VBB. B1 TO A/V RACKS 023. C1 TO A/V RACKS AT STAGE LOCATION. D1 TO SBB. E1 TO A/V RACKS 023 COMPUTER FLOOR. F1 TO VDB-501. G1 TO ADB-501. H1 TO CPB. 200 BALCONY-1 201 VESTIBULE 202 CRYING ROOM 203 MACHINE ROOM 204 MEZZANINE 221 PROJECTION ROOM S-21 STAIR-1 S-22 STAIR-2 S-23 STAIR-3 S-24 STAIR-4 ROOM INDEX L L SC L DN UP UP DN UP UP UP F.E.C. F.E.C. F.E.C. F.E.C. DN UP DN A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A AA AB AD 1 3 5 H3 2.3 4 X9 X2 X3 X6 X7 X8 H2 4.6 H4 P 4.3 H5 4.8 M L C L4 Q S T ND U H1.5 1.5 H3.2 X 2.0 3.8 H1 2.6 3.6 0.8 G Y2 Z L2 L3 P12 P15 X10 X4 X5 X1 0.4 2.4 2.8 3.3 4.4 Y E F B Z2 Z3 Z1 Z4 P4 P5 P3 P2 P6 P7 P10 N1 N2 N3 M1 M2 M3 N 1.3 2.1 W W3 W2 W1 P8 P9 2.2 4.2 N4 M4 4.1 P1 T4 T1 T2 T3 T5 S1 S2 S3 S4 S5 A1 A2 J J1 J2 3.1 A. GF GF AV AV AV AV AV AV AV AV AV TL1 AV TL1 CAM 6 6 6 TL1 AV CAM CAM CAM CAM 6 6 6 AV AV TL1 TL1 AV AV TL1 110 110 110 110 110 110 R WP/GF GF GF GF AV AV AV AV CAM AV CAM AV AV CAM AV RPAV1 - 34 RPAV1 - 37 F E1 B K L C1 L E1 G E1 G E1 RPAV1 - 12 RPAV1 - 13 G E1 G E1 RPAV1 - 14 RPAV1 - 15 B F E1 G H J E1 RPAV1 - 16 - <unnamed> RPAV1 - 18 RPAV1 - 19 G E1 G E1 G E1 G E1 RPAV1 - 20,22 VDB RPAV1 - 21,23 RPAV1 - 24,26 E E E L E1 A C C1 7 7 7 AV AV 7 7 A A A A A C1 A C1 C PRJ PRJ RPAV1 - 30 RPAV1 - 31 RPAV5-1-5 RPAV5-6-10 RPAV5-11-15 RPAV5-16-20 RPAV5-21-25 RPAV5 - 28 RPAV5 - 27 RPAV5 - 26 RPAV5 - 29 RPAV5 - 30 S5 AV S5 AV RPAV6 - 2 S5 AV S5 AV S5 AV RPAV6 - 1 A A A A A C1 FB1 AV RPAV6 - 6 FB1 AV RPAV6 - 7 FB1 AV RPAV6 - 8 FB1 AV RPAV6 - 9 N C1 N C1 N C1 N C1 RPAV6 - 10,12 AV C C1 RPAV6 - 11,13 AV C C1 RPAV6 - 15,17 AV C C1 RPAV6 - 14,16 C C1 AV S4 S4 S4 S4 RPAV1 - 10 AV 6 RPAV1 - 25 RPAV1 - 11 AV A A RPAV1 - 29 RP2 - 15 RP2 - 16 RP2 - 18 RP2 - 20 RP2 - 21 RP2 - 22 RP2 - 23 RP2 - 24 RP2 - 25 RP2 - 26 GF RP2 - 27 RAP REMOTE ANNUNCIATOR PANEL RPAV1 - 39,41 AV 4 4 4 RPAV1 - 40,42 AV 4 RPAV1 - 40,42 6 EF-1 RP5 - 10 6 EF-2 RP5 - 9 RP4 - 18,20,22 RP2 - 1 UH-1 11 RP1 - 40 EF-5 6 RP2 - 2 RP2 - 28 RP2 - 3 6 9 9 RTU-4 RTU-3 A A A A A A C1 C1 A A A A 1 1 1 PRJ 3 6 3 3 2 5 5 EF-6 12 12 13 13 13 7 8 S-11 S-12 119 120 118 117 116 115 106 107 113 111 102 105 108 109 101 S-13 S-14 104 C-101 103 14 14 14 14 15 15 GF GF 16 16 16 16 16 17 18 DWH-2 UH-3 UH-3 11 11 FB1 AV RPAV6 - 3 N C1 MDP3-7 MDP3-6 RP7-14 RP7-31 RP7-8 GF RP2 - 19 RP2 - 17 A 112 110A 5 5 Date: Scale Drawn By Checked By Project Number ARCHITECTURE PLANNING INTERIOR DESIGN STRUCTURAL ENGINEERING 424 East Fourth Street Cincinnati, w w w . c h a r c h Ohio i t e c t s . 45202 c o m tel: 513/241/4474 fax: 513/241/0081 ISSUANCES COMPUTER FILE 1400 West Dorothy Lane Dayton, Ohio 45409-1310 Tel: (937) 224-0861 Fax: (937) 224-5777 3417 South Sherman Drive Beech Grove, IN 46107 Tel: (317) 780-1555 Fax: (317) 780-6525 750 North Orleans, Suite 400 Chicago, IL 60610 Tel: (312) 944-8230 Fax: (312) 944-8297 117 East Washington Street, Suite 200 Indianapolis, IN 46204 Tel: (317) 637-2222 Fax: (317) 637-2260 1137 West Taylor St. Suite 316 Chicago, IL 60607 Tel: (312) 224-8460 Fax: (312) 224-8961 1025 N.Watery Ln. Brigham City, UT 84302 TEL: (453) 723-5000 FAX: (453) 538-5506 6622 Kingspointe Parkway Orlando, FL 33819 Tel: (407) 816-9400 Fax: (407) 816-9300 10.18.07 No. Description Date 1 SCHEMATIC DESIGN 2 3 4 5 6 7 8 11 DESIGN DEVELOPMENT 01.18.08 CD 50% 03.14.08 PERMIT SET 04.25.08 ADDENDUM #2 05.16.08 ADDENDUM #3 05.22.08 ADDENDUM #5 06.04.08 PERMIT SET 06.10.08 CONSTRUCTION SET 08.01.08 12 ASI6 12.23.08 13 PERMIT RE-SUBMISSION 1.28.09 1/8" = 1'-0" 2/3/2009 5:18:57 PM C:\Drawings\Northview Church\2007-06019-Electrical-Central-Local.rvt E301 FIRST FLOOR - POWER PLAN New Worship Center Checker Author 05-22-08 2007-06019 1/8" = 1'-0" 1 POWER & SYSTEMS - LEVEL-1 - NEW WORK GENERAL NOTES A E.C. TO COORDINATE WITH A/V DRAWINGS: AV201, AV211, AV202, AV212, AV203, AV213, AV204, AV205, AV215, AV251, AV252, AV253, AV301, AV302 FOR BOX TYPE, MOUNTING HEIGHT, EXACT LOCATION FOR A/V DEVICES AND A/V EQUIPMENT AND ANY ADDITIONAL ELECTRICAL REQUIREMENTS PRIOR TO ROUGH-IN. A/V CONSULTANT: CRAIG COMPTON PRO-SOUND PH: 407-816-9400 E-MAIL: CCOMPTON@PROSOUND.NET PLAN NOTES 1 PROVIDE RECEPTACLE WITH NEMA CONFIGURATION - 6-20R. COORDINATE EXACT REQUIREMENTS WITH A/V CONSULTANT PRIOR TO ROUGH-IN. 2 CABLE TRAY - 24" WIDTH x 4" DEPTH - CABLOFIL OR EQUAL. COORDINATE MOUNTING HEIGHT AND OTHER REQUIREMENTS WITH A/V CONSULTANT PRIOR TO ROUGH-IN. 3 WIREMOLD TRENCH DUCT - 12" WIDTH x 4" DEPTH. LID TO BE CUSTOM MADE. COORDINATE WITH ARCHITECT / A/V CONSULTANT FOR REQUIREMENTS. 4 PROVIDE SINGLE GANG BOX WITH 3/4" CONDUIT TO "CONTROL EQUIPMENT RACK" IN BOOTH. PROVIDE BLANK COVERPLATE. DATA OUTLET AND CABLING BY OTHERS. COORDINATE EXACT LOCATION AND MOUNTING HEIGHT WITH LIGHTING CONSULTANT / SYSTEM INTEGRATOR PRIOR TO ROUGH-IN. 5 PROVIDE DUCT MOUNTED SMOKE DETECTORS ON THE RETURN DUCT FOR ROOFTOP UNITS AND INTERFACE WITH FACP TO SHUT-DOWN UNITS UPON ALARM. COORDINATE LOCATION WITH HVAC DRAWINGS. 6 EXHAUST FAN. PROVIDE ELECTRICAL ROUGH-IN AND FINAL CONNECTIONS. COORDINATE LOCATION, CONTROL, AND OTHER ELECTRICAL REQUIREMENTS WITH HVAC DRAWINGS WITH HVAC DRAWINGS. 7 ELECTRICAL WATER HEATER. PROVIDE FUSED DISCONNECT. PROVIDE ELECTRICAL ROUGH-IN AND FINAL CONNECTIONS PER REQUIREMENTS. COORDINATE LOCATION WITH PLUMBING DRAWINGS. 8 DEDICATED OUTLET WITH 120V, 20A CIRCUIT FOR RECIRCULATING PUMP FOR WATER HEATER. COORDINATE LOCATION WITH PLUMBING DRAWINGS. 9 PROVIDE GFI/WP RECEPTACLE AND VAPORPROOF APPLETON LIGHT FIXTURE FOR ROOFTOP UNITS. COORDINATE LOCATION WITH UNIT. PROVIDE WEATHERPROOF LIGHT SWITCH FOR LIGHT FIXTURE. 10 COIL PUMP. PROVIDE COMBINATION STARTER AND SIZE PER REQUIREMENTS. COORDINATE OTHER ELECTRICAL REQUIREMENTS WITH HVAC DRAWINGS. 11 UNIT HEATER. PROVIDE ELECTRICAL ROUGH-IN AND FINAL CONNECTIONS. COORDINATE LOCATION, MOUNTING HEIGHT, AND OTHER ELECTRICAL REQUIREMENTS WITH HVAC DRAWINGS. 12 CIRCUIT # RPAV6-2 FEEDS POWER OUTLETS IN THESE BOXES. 13 CIRCUIT # RPAV6-1 FEEDS POWER OUTLETS IN THESE BOXES. 14 PROVIDE SINGLE GANG BOX WITH 3/4" CONDUIT TO THE SERVER ROOM. PROVIDE A BLANK COVER PLATE. RJ45 OUTLET AND CAT5 CABLING BY OTHERS. OVERALL LENGTH SHOULD NOT EXCEED 285'. 15 PROVIDE FUSED DISCONNECT TYPE NEMA 3R FOR ROOF TOP UNIT AND WIRE PER REQUIREMENTS. 16 CONDUITS FROM MAIN LEVEL, BOOTH, 1ST BALCONY, AND 2ND BALCONY ARE TO BE ROUTED THRU THE CHASE SPACE AVAILABLE AT THE BACK OF THE NEW WORSHIP CENTER NEAR THE REST ROOMS, STAIRS, ETC., DOWN BELOW THE UNDERFLOOR DUCT WORK BELOW THE SEATING IN THE MAIN LEVEL TO THE STAGE RACK LOCATION, RACK LOCATION IN THE PIT LEVEL, ELECTRICAL PANELS, SWITCHBOARD "MDP3", ETC. E.C. TO COORDINATE WITH PLUMBING AND HVAC CONTRACTORS PRIOR TO INSTALLING THE CONDUITS TO PREVENT CONFLICTS BETWEEN THE TRADES. 17 PROVIDE (3) SPARE 3" CONDUITS FROM GATHERING CENTER TO THE STAGE RACK LOCATION FOR FUTURE A/V REQUIREMENTS. COORDINATE WITH A/V CONSULTANT. 18 STAGE RIGGING SYSTEM - PROVIDE REQUIREMENTS PER PANEL SCHEDULE "RP3". COORDINATE ALL REQUIREMENTS WITH SHEETS TR1.0 AND TR2.0 PRIOR TO ROUGH-IN. A/V CONDUIT NOTES A (1) 3/4"C. B (3) 1"C. C (1) 1"C. D (1) 2"C. E (1) 1-1/2"C. F (3) 1-1/2"C. G (2) 1"C. H (2) 2"C. J (2) 4"C. K (3) 4"C. L (3) 2"C. M (1) 1/2"C. N (2) 1-1/4"C. O (2) 1-1/2"C. A1 TO VBB. B1 TO A/V RACKS 023. C1 TO A/V RACKS AT STAGE LOCATION. D1 TO SBB. E1 TO A/V RACKS 023 COMPUTER FLOOR. F1 TO VDB-501. G1 TO ADB-501. H1 TO CPB. 101 ENTRANCE LOBBY 102 VESTIBULE 103 WORSHIP CENTER 104 SOUND BOOTH 105 CHAIR STORAGE/CATERING 106 VESTIBULE 107 VESTIBULE 108 MEN'S RESTROOM 109 JANITOR ROOM 110 WOMEN'S RESTROOM 111 WOMEN'S RESTROOM 112 VESTIBULE 113 VESTIBULE 115 STORAGE 116 WORKSHOP 117 SIDE PLATFORM 118 DELIVERY 119 PLATFORM 120 SIDE PLATFORM 124 JANITOR ROOM C-101 CORRIDOR S-11 STAIR-1 S-12 STAIR-2 S-13 STAIR-3 S-14 STAIR-4 ROOM INDEX J J J J J J J L L J J J J V V V S H S F F F L L L H F V V V W L L L L F F L L F L L F V V V V V V V L UP UP UP F.E.C. F.E.C. F.E.C. DN UP LP1 LP2 RP1 RP2 MDP3 WP/GF WP/GF TL2 TL2 TL2 TL2 TL2 AV AV AV AV AV C1 VBB C1 SBB GF TV1 AV C1 TL1 TV1 C1 RF RF GF GF 2 1 GF GF C1 AV RF AVRF RF RF AV AV AV AV RF RF AV RF AV AV C1 AV CP AV RPAV1 RPAV2 S-02 RPAV1 - 1 RPAV1 - 2 RPAV1 - 3 RPAV1 - 4 RPAV1 - 5 RPAV1 - 6 RPAV1 - 7 RPAV1 - 8 A1 A A A1 A A A B1 A A A1 A A A1 A A A1 A A1 A A1 C B1 A B1 B B1 C B1 A A1 H O A B1 B A D1 A D1 A A A A A RPAV3 RPAV4 RPAV5 RPAV4-1-6 RPAV4-7-12 RPAV4-13-18 RPAV4-19-24 TL2 SBX JB-102 F F G FB1 AV RPAV4 - 30 AV AV RPAV4 - 32 G RPAV4-33-36 RPAV4-37-40 AV AV AV RPAV1 - 36 EP FACP RPAV6 RP1 - 10 RP1 - 11 RPAV1 - 35 4 5 7 6 8 STAGE LIFT RP1 - 12 RP1 - 13 RP1 - 14 RP1 - 15 RP1 - 16 RP1 - 17 RP1 - 18 RP1 - 19 RP1 - 20 RP1 - 21 RP1 - 22 RP1 - 23 RP1 - 24 RP1 - 25 RP1 - 26 RP1 - 27 RP1 - 29 RP1 - 30 RP1 - 31 RP1 - 32 RP1 - 33 RP1 - 34 RP1 - 35 RP1 - 36 RP1 - 37 RP1 - 38 SUMP PUMP MDP3-13 MCP-1 MCP-2 RP3 RP4 3 VFD 13 CUH-1 RP2 - 4 RP2 - 5 RP2 - 6 RP2 - 7 RP2 - 8 RP2 - 9 RP2 - 10 GF GF RP2 - 11 RP2 - 13 R R R RP5 CUH-2 13 RP2 - 12 CUH-3 13 CUH-4 13 GF 22 16 UH-2 RP5 - 8 17 AC-3 14 AC-4 14 RP4 - 7,9 RP4 - 8,10,12 RP4 - 11,13 12 CU-3 RP4 - 14,16 CU-4 12 RP4 - 15,17 DP3 A A GROUND BAR C1 AV 19 19 B B RPAV1 - 9 RPAV4 - 25 RPAV4 - 26 AV AV AV AV AV AV RPAV4 - 27 AV AV RPAV4 - 28 AV AV RPAV4 - 29 AV AV 18 23 20 21 RP5 - 15 DPL-1 033 S-01 001 019 020 021 022 024 C-005 027 025 029 S-03 C-007 003 002 C-001 004 005 006 007 008 009 010 011 015 016 018 014A 014 013 C-004 034 023 026 032 031 030 028 C-009 C-003 019A 017 018A 018 TELEPHONE BACKBOARD RP2 - 30 RP2 - 29 48" 48" 24 24 24 24 24 24 24 24 24 48" 48" 48" 48" 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 24 GF RP2 - 31 GF GF GF RP2 - 14 25 25 EP - 23,25,27 ATS #1 GENERATOR REMOTE ANNUNCIATOR EF-7 CU-1 12 CU-2 12 RP4 - 19,21,23 RP4 - 24,26,28 DWH-1 26 RP6 RP7 RP6-8 VAV-5 VAV-4 RP6-13 RP6-7 RP6-2 VAV-2 VAV-3 RP6-1 VAV-1 RP6-14 RP6-19 VAV-6 VAV-7 RP6-20 VAV-8 RP6-25 VAV-9 RP6-26 VAV-10 VAV-11 RP6-31 VAV-12 RP6-32 VAV-13 RP7-1 VAV-14 RP7-2 VAV-15 RP7-7 RP7-20 RP-13 RP7-19 RP7-26 RP7-25 Date: Scale Drawn By Checked By Project Number ARCHITECTURE PLANNING INTERIOR DESIGN STRUCTURAL ENGINEERING 424 East Fourth Street Cincinnati, w w w . c h a r c h Ohio i t e c t s . 45202 c o m tel: 513/241/4474 fax: 513/241/0081 ISSUANCES COMPUTER FILE 1400 West Dorothy Lane Dayton, Ohio 45409-1310 Tel: (937) 224-0861 Fax: (937) 224-5777 3417 South Sherman Drive Beech Grove, IN 46107 Tel: (317) 780-1555 Fax: (317) 780-6525 750 North Orleans, Suite 400 Chicago, IL 60610 Tel: (312) 944-8230 Fax: (312) 944-8297 117 East Washington Street, Suite 200 Indianapolis, IN 46204 Tel: (317) 637-2222 Fax: (317) 637-2260 1137 West Taylor St. Suite 316 Chicago, IL 60607 Tel: (312) 224-8460 Fax: (312) 224-8961 1025 N.Watery Ln. Brigham City, UT 84302 TEL: (453) 723-5000 FAX: (453) 538-5506 6622 Kingspointe Parkway Orlando, FL 33819 Tel: (407) 816-9400 Fax: (407) 816-9300 10.18.07 No. Description Date 1 SCHEMATIC DESIGN 2 3 4 5 6 7 8 11 DESIGN DEVELOPMENT 01.18.08 CD 50% 03.14.08 PERMIT SET 04.25.08 ADDENDUM #2 05.16.08 ADDENDUM #3 05.22.08 ADDENDUM #5 06.04.08 PERMIT SET 06.10.08 CONSTRUCTION SET 08.01.08 12 ASI6 12.23.08 13 PERMIT RE-SUBMISSION 1.28.09 1/8" = 1'-0" 2/3/2009 4:29:12 PM \\DAYDATA1\TEAMDATA\l600\2007-06019\DRAWINGS\2007-06019-Central.rvt E300 PIT LEVEL - POWER PLAN New Worship Center Checker Author 05-22-08 2007-06019 1/8" = 1'-0" 1 POWER & SYSTEMS - PIT LEVEL GENERAL NOTES A E.C. TO COORDINATE WITH A/V DRAWINGS: AV201, AV211, AV202, AV212, AV203, AV213, AV204, AV205, AV215, AV251, AV252, AV253, AV301, AV302 FOR BOX TYPE, MOUNTING HEIGHT, EXACT LOCATION FOR A/V DEVICES AND A/V EQUIPMENT AND ANY ADDITIONAL ELECTRICAL REQUIREMENTS PRIOR TO ROUGH-IN. A/V CONSULTANT: CRAIG COMPTON PRO-SOUND PH: 407-816-9400 E-MAIL: CCOMPTON@PROSOUND.NET B PROVIDE 3/4"C. FROM EACH VOLUME CONTROL BOX ON PIT LEVEL TO ABOVE LAY-IN CEILING. PROVIDE NYLON BUSHING AT CEILING END OF CONDUIT. PLAN NOTES 1 DEDICATED RECEPTACLE FOR SUMP PUMP AT ELEVATOR PIT. COORDINATE LOCATION WITH PUMP PRIOR TO ROUGH-IN. 2 PROVIDE GFCI RECEPTACLE, VAPOR-PROOF LIGHT FIXTURE WITH WIRE GUARD AND LIGHT SWITCH PER CODE REQUIREMENTS NEARS STOP SWITCH. PROVIDE 26W 'PL' LAMP FOR THE LIGHT FIXTURE. 3 STAGE LIFT - 208V, 3PH, 60HZ, 10HP DRIVE MOTOR. PROVIDE 240V, 3 POLE, 60A FUSED DISCONNECT WITH 40A FUSES. PROVIDE ALSO (2) 120V, 20A DEDICATED CIRCUITS FOR LIFT PLATFORM (MCP-2) AND STAGE LIFT (MCP-1). COORDINATE ALL ELECTRICAL REQUIREMENTS WITH STAGE LIFT SUPPLIER PRIOR TO ROUGH-IN. SEE SHEET TP1.0 FOR STAGE LIFT DETAILS AND ONE LINE DIAGRAM. 4 FIRE PUMP CONTROLLER. 5 FIRE PUMP AUTOMATIC TRANSFER SWITCH. 6 FIRE PUMP. PROVIDE ELECTRICAL ROUGH-IN AND FINAL CONNECTIONS. COORDINATE REQUIREMENTS WITH PLUMBING DRAWINGS PRIOR TO ROUGH-IN. SEE DETAILS IN SINGLE-LINE DIAGRAM ON SHEET E400. CONDUCTORS FOR THE FIRE PUMP INSIDE THE BUILDING TO BE ENCASED IN MINIMUM 2" CONCRETE AND BE PROTECTED BY FIRE RATED ASSEMBLY TO ACHIEVE MINIMUM FIRE RATING OF 2 HOURS DEDICATED TO FIRE PUMP CIRCUITS. FIRE PUMP NEEDS TO BE INSTALLED PER NEC 695 REQUIREMENTS. 7 JOCKEY PUMP CONTROLLER. 8 JOCKEY PUMP. PROVIDE ELECTRICAL ROUGH-IN AND FINAL CONNECTIONS. COORDINATE REQUIREMENTS WITH PLUMBING DRAWINGS. 9 NOTE OMITTED. 10 NOTE OMITTED. 11 NOTE OMITTED. 12 CONDENSING UNIT. PROVIDE NEMA 3R FUSED DISCONNECT. PROVIDE ELECTRICAL ROUGH- IN AND FINAL CONNECTIONS. COORDINATE LOCATION AND OTHER ELECTRICAL REQUIREMENTS WITH HVACDRAWINGS. 13 CABINET HEATER. PROVIDE ELECTRICAL ROUGH-IN AND FINAL CONNECTIONS. COORDINATE LOCATION, MOUNTING ARRANGEMENT, AND OTHER ELECTRICAL REQUIREMENTS WITH HVAC DRAWINGS PRIOR TO ROUGH-IN. 14 A/C UNIT. PROVIDE FUSED DISCONNECT ON UNIT. PROVIDE ELECTRICAL ROUGH-IN AND HVAC DRAWINGS. 15 NOTE OMITTED. 16 UNIT HEATER. PROVIDE ELECTRICAL ROUGH-IN AND FINAL CONNECTIONS. COORDINATE LOCATION, CONTROLS, AND OTHER ELECTRICAL REQUIREMENTS WITH HVAC DRAWINGS. 17 EXHAUST FAN. PROVIDE ELECTRICAL ROUGH-IN AND FINAL CONNECTIONS. COORDINATE LOCATION, CONTROLS, AND OTHER ELECTRICAL REQUIREMENTS WITH HVAC DRAWINGS. 18 SUMP PUMP FOR STAGE LIFT. PROVIDE OUTLET AND DEDICATED 120V, 20A CIRCUIT. COORDINATE LOCATION AND MOUNTING REQUIREMENTS WITH PLUMBING DRAWINGS. 19 PROVIDE WIREMOLD "RFB4" STEEL RECESSED FLOOR BOX WITH (2) RFB-DR INTERNAL DUPLEX OUTLET BRACKETS AND (2) DTB-2-4TKO COMMUNICATION BRACKETS WITH S38PPTCAL FLANGED PARTITION FEED COVER ASSEMBLIES. PROVIDE ALL NECESSARY ACCESSORIES AND FITTINGS TO MAKE A COMPLETE UNIT. 20 ELECTRICAL WATER HEATER. PROVIDE FUSED DISCONNECT. PROVIDE ELECTRICAL ROUGH-IN AND FINAL CONNECTIONS PER REQUIREMENTS. COORDINATE LOCATION WITH PLUMBING DRAWINGS. 21 DEDICATED OUTLET WITH 120V, 20A CIRCUIT FOR RECIRCULATING PUMP FOR WATER HEATER. COORDINATE LOCATION WITH PLUMBING DRAWINGS. 22 RECEPTACLE FOR WATER COOLER. COORDINATE OUTLET LOCATION WITH UNIT. 23 ISOLATION TRANSFORMER - 225KVA - 230V/3PH PRIMARY - 230V/3PH/4WIRE SECONDARY. 24 PROVIDE SINGLE GANG BOX WITH 3/4" CONDUIT TO THE SERVER ROOM. PROVIDE A BLANK COVER PLATE. RJ45 OUTLET AND CAT5 CABLING BY OTHERS. OVERALL LENGTH SHOULD NOT EXCEED 285'. 25 LIGHTING CONTROL PANELS - "LP1", "LP2", AND "EP" - LIGHTOLIER CONTROLS - LOW VOLTAGE LIGHTING CONTROL PANEL - 48 CIRCUITS. 26 DISCONNECT SWITCH FOR FIRE PUMP. SEE SINGLE-LINE DIAGRAM ON SHEET E400 FOR MORE INFORMATION. A/V CONDUIT NOTES A (1) 3/4"C. B (3) 1"C. C (1) 1"C. D (1) 2"C. E (1) 1-1/2"C. F (3) 1-1/2"C. G (2) 1"C. H (2) 2"C. J (2) 4"C. K (3) 4"C. L (3) 2"C. M (1) 1/2"C. N (2) 1-1/4"C. O (2) 1-1/2"C. A1 TO VBB. B1 TO A/V RACKS 023. C1 TO A/V RACKS AT STAGE LOCATION. D1 TO SBB. E1 TO A/V RACKS 023 COMPUTER FLOOR. F1 TO VDB-501. G1 TO ADB-501. H1 TO CPB. 001 STORAGE ROOM 002 SERVER ROOM 003 CONFERENCE ROOM 004 OFFICE 005 BLUE SKY ROOM 006 OFFICE 007 OFFICE 008 OFFICE 009 OFFICE 010 OFFICE 011 OFFICE 013 RECEPTIONIST 014 WAIT/LOBBY 014A SUITE ENTRY 015 WORK STATIONS 016 WORK ROOM 017 CHANGING ROOM WAITING AREA 018 MEN'S CHANGING ROOM 018A MEN'S TOILET 019 WOMEN'S CHANGING ROOM 019A WOMEN'S TOILET 020 MECHANICAL ROOM 021 GREEN ROOM 022 VIDEO CONTROL 023 PRODUCTION RACKS 024 TAPE STORAGE 025 VESTIBULE 026 AUDIO CONTROL 027 VIDEO EDIT 028 STORAGE 029 RECORDING STUDIO 030 VOICE 031 DRUM 032 VESTIBULE 033 TRAP ROOM 034 FIRE PUMP ROOM C-001 CORRIDOR C-003 CORRIDOR C-004 CORRIDOR C-005 CORRIDOR C-007 CORRIDOR C-009 CORRIDOR S-01 STAIR-1 S-02 STAIR-2 S-03 STAIR-3 ROOM INDEX VERTICAL MOUNT. 20A-125V DUPLEX RECEPTACLE, NEMA 5-20R. (46" M.H.). 20A-125V DOUBLE DUPLEX RECEPTACLE. NEMA 5-20R, (18" M.H.) TWO-GANG ASSEMBLY. 20A-125V DUPLEX RECEPTACLE, NEMA 5-20R (18" M.H.). 20A-125V SINGLE RECEPTACLE, NEMA 5-20R (18" M.H.). JUNCTION BOX. WIRE & CONDUIT IN OR BELOW FLOOR SLAB OR BELOW GRADE. WIRE & CONDUIT IN WALL OR ABOVE CEILING. EACH ARROWHEAD REPRESENTS ONE COMPLETE CIRCUIT; CAPITAL LETTER DENOTES PANEL; NUMBER DENOTES CIRCUIT. A-1&2 LIGHTING FIXTURE ON NIGHT LIGHT OR EMERGENCY CIRCUIT. H1 B1 V VALVE SUPERVISORY SWITCH. W WATER FLOW SWITCH. S DUCT MOUNTED SMOKE DETECTOR (S/SUPPLY, R/RETURN). S/R H CEILING MOUNTED HEAT DETECTOR. S CEILING MOUNTED SMOKE DETECTOR. F FIRE ALARM SENDING STATION (46" M.H.). FIRE ALARM SIGNALING LIGHT (80" A.F.F.), (# WHEN SHOWN INDICATES CANDELA RATING OF STROBE. WHEN A # IS NOT SHOWN, THE STROBE SHALL BE RATED 15 CANDELA IN CORRIDORS AND 30 CANDELA FOR ALL OTHER LOCATIONS. L 15 BE RATED 15 CANDELA IN CORRIDORS AND 30 CANDELA FOR ALL OTHER LOCATIONS. CANDELA RATING OF STROBE. WHEN A # IS NOT SHOWN, THE STROBE SHALL F FIRE ALARM HORN & SIGNAL LIGHT (80" A.F.F.), (# WHEN SHOWN INDICATES 15 BUSHED CONDUIT OUT ABOVE ACCESSIBLE CEILING. "W" INDICATES 48" M.H., "P" INDICATES 48" M.H.). STUB AN EMPTY 3/4" W TELEPHONE OUTLET (18" M.H. EXCEPT WHEN SUBSCRIPT LETTER IS SHOWN, 48" M.H.). SINGLE GANG OUTLET BOX WITH BLANK COVERPLATE. STUB AN EMPTY 3/4" BUSHED CONDUIT OUT ABOVE ACCESSIBLE CEILING. DATA OUTLET (18"M.H. EXCEPT WHEN SUBSCRIPT "W" IS SHOWN, MOUNT AT CIRCUIT BREAKER PANEL, SURFACE MOUNTED. CIRCUIT BREAKER PANEL, FLUSH MOUNTED. ELECTRIC MOTOR. COMBINATION MOTOR STARTER AND DISCONNECT SWITCH. SCHEDULE NOTES: 1 2 3 4 PROVIDE MOUNTING AND DIRECTIONAL ARROWS PER PLAN. COORDINATE EGRESS PATH WITH ARCHITECTURAL DRAWINGS PRIOR TO ORDERING ANY FIXTURES. MOUNTING HEIGHT 24'-0". MOUNTING HEIGHT 12'-0". SEE ALSO "GALLEGOS" LIGHTING SHEETS FOR LIGHT FIXTURE SCHEDULES. SCHEDULE NOTES: 1 BUSSMANN POWER MODULE SWITCH. SIZE PER MANUFACTURER'S RECOMMENDATIONS. 2 FUSED DISCONNECT TO BE INSTALLED PER NEC-695 REQUIREMENTS. 3 CONTROL PANEL BY STAGE LIFT SUPPLIER. E.C. TO COORDINATE WITH SUPPLIER FOR ALL ELECTRICAL REQUIREMENTS PRIOR TO ROUGH-IN. PROVIDE (2) DEDICATED 120V, 20A CKTS TO MCP-1 AND MCP-2. SEE SINGLE-LINE DIAGRAM IN SHEET # TP1.0 FOR DETAILS. 4 CONTROL PANEL FOR RIGGING SYSTEM BY SYSTEM SUPPLIER. E.C. TO COORDINATE FOR ALL ELECTRICAL REQUIREMENTS WITH RIGGING SYSTEM SUPPLIER PRIOR TO ROUGH-IN. PROVIDE (10) 120V, 20A CIRCUITS PER MANUFACTURER'S REQUIREMENTS. SEE SINGLE-LINE DIAGRAM IN SHEET # TR1.0 FOR DETAILS. 5 WEATHER PROOF DISCONNECT REQUIRED. 6 EC SHALL WIRE FAN THROUGH LINE VOLTAGE THERMOSTAT. HC SHALL FURNISH THERMOSTAT TO E.C. A CONVEYANCE / CONDUIT INSTALLATION - SHALL MEET ALL ANSI/NFPA 70 (NATIONAL ELECTRICAL CODE) REQUIREMENTS. B ALL CONDUCTORS WILL BE COPPER IN CONDUIT. INSULATION SHALL BE RATED FOR 600V. C ALL WORK WILL BE DONE IN ACCORDANCE WITH THE NEC. D ALL 20 AMP. 120 VOLT POWER CIRCUITS SHALL CONSIST OF #12 AWG CONDUCTORS UNLESS INDICATED OTHERWISE. E CONDUITS OF DIFFERENT MATERIALS SHALL NOT BE MIXED INDISCRIMINATELY IN THE SAME SYSTEM. F MAINTAIN 16" SPACING BETWEEN RECEPTACLES AND OTHER RECESSED OUTLETS EVEN WHEN LOCATED ON OPPOSITE SIDES OF PARTITION TO ELIMINATE SOUND TRANSMISSION FROM ONE SPACE TO THE OTHER. CENTER DEVICES WHERE APPLICABLE IN EACH WALL SECTION. G NO SECTION OF A TELECOMMUNICATION CONDUIT SYSTEM SHALL BE LONGER THAN 100' OR CONTAIN MORE THAN TWO 90° BENDS, OR 180° TOTAL OF BENDS AND ELEVATION CHANGES, BETWEEN PULL POINTS OR PULL BOXES. FOR CONDUIT RUNS THAT TOTAL MORE THAN 100' IN LENGTH, INSERT PULL BOXES SO THAT NO SEGMENT EXCEEDS THE 100' LIMIT. H BENDS IN TELECOMMUNICATIONS CONDUITS SHALL BE LONG SWEEPS WITH A RADIUS OF 10 TIMES THE INSIDE DIAMETER OF THE CONDUIT. I ALL METALLIC RACEWAYS (I.E., CONDUITS AND CABLE TRAY SYSTEMS) SHALL BE CONNECTED TO THE EXPANDED BUILDING GROUND LOOP, DIRECTLY TO THE COMMUNICATIONS RESOURCE ROOMS BUSBAR OR VIA INTERCONNECTION OF CONVEYANCE ALREADY CONNECTED TO BUSBAR. J FIRE STOPPING OF CONVEYANCE MUST MEET ALL APPLICABLE BUILDING CODE REQUIREMENTS. K CONFIRM DATA AND COMMUNICATION DEVICE LOCATIONS WITH ARCHITECT PRIOR TO ROUGH-IN. L REFER TO ARCHITECTURAL SHEETS FOR EXACT LOCATION OF TACKBOARDS, MARKER BOARDS, CASEWORK, DESKS, ETC.- CONFIRM LOCATION OF ALL ELECTRICAL DEVICES WITH ARCHITECT PRIOR TO ROUGH-IN. M ALL EXIT SIGNAGE SHALL BE WIRED AHEAD OF LOCAL SWITCHING. N REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATION OF LIGHTS, DIFFUSERS, ETC. O ALL THEATRICAL LIGHITNG REQUIREMENTS SHALL BE COORDINATED WITH THE THEATRICAL LIGHTING CONSULTANT PRIOR TO ANY WORK BEING PERFORMED. P VERIFY EXACT LOCATION OF ALL LIGHTING FIXTURES WITH MECHANICAL DUCTS AND SPRINKLER PIPES AND HEADS BEFORE ROUGH-IN TO PREVENT CONFLICTS. Q EXACT LOCATION OF ALL DEVICES SERVING EQUIPMENT TO BE VERIFIED AT SITE WITH ARCHITECTURAL DRAWINGS PRIOR TO ROUGH-IN. R ALL EMPTY CONDUITS SHALL BE INSTALLED WITH PULL WIRE PER SPECIFICATIONS. S ALL AUDIO / VIDEO DEVICES AND EQUIPMENT LOCATIONS AND REQUIREMENTS SHALL BE COORDINATED WITH THE AUDIO / VIDEO CONTRACTOR PRIOR TO ANY WORKING BEING PERFORMED. T ALL DEVICES INSTALLED IN / ON WALLS, SHALL BE DONE SO THAT THEY ARE AT EQUAL ELEVATIONS. (I.E. DEVICES INSTALLED AT 18" M.H. SHALL ALL BE AT 18" M.H., ALL DEVICES INSTALLED AT 46" M.H. SHALL BE INSTALLED AT 46" M.H.) MOTOR 120V-1PH CHARACTERISTICS NAMEPLATE CIRCUIT NO. NUMBER FLA 407/450 HP KVA OR MOTOR LOCATION - 208V-3PH 208V-1PH - MAGNETIC MANUAL NEMA SIZE LOCATION TYPE AC DRIVES (VFD) MOTOR O/L BUILT-IN 2-SPEED 2-WINDING MOTOR CONT. NEAR MOTOR SEE NOTE TYPE STARTER FURNISHED BY ROOM NUMBER SEE NOTE PANEL EQUIP. CONT. CENTER STARTER MANUAL DISC. SWITCH NEAR MOTOR OR BREAKER FEEDER SW. RECEPTACLE PANELBOARD PANEL EQUIP. CONT. CENTER MOTOR CONT. DISCONNECT MEANS LOCATION FURNISHED BY INTEGRAL WITH MOTOR NO. BY E.C. INTERLOCK WITH FURNISHED BY SEE NOTE EQUIPMENT STARTER MANUAL AT CONTROL GRD. SIZE WIRE SIZE CONDUCTORS NUMBER OF SEE NOTE SEE NOTE CONDUIT SIZE FEEDER FIXTURE SYMBOL CAT. NO. G.E. LAMP WATTS/LAMP INCAN. FLUOR. FIXTURE VOLTAGE H.I.D. QUANTITY LAMPS CS-CEIL. SURFACE BRONZE C--CHAIN MTD. STANDARD SEE NOTE ALUMINUM BLACK WHITE UC-UNDER CAB. TRIM COLOR WM-WALL MTD. SM-STEM MTD. R--RECESSED S--SURFACE MOUNTING SEE NOTE DEPTH LENGTH WIDTH DIAMETER OR SIZE (IN.) MANUFACTURER & CATALOG NO. OTHER ACCEPTABLE MANUCATURES MEDIA DIFFUSING X1 LED INCLUDED 120 DUAL-LITE # LES SERIES MCPHILBEN, SURE-LITE CLEAR MIRROR FACE W/RED STENCIL LETTERS 4 PER PLAN 14.38 9.88 1.38 1 X2 LED 7 INCLUDED 120 DUAL-LITE # LT SERIES MCPHILBEN, SURE-LITE PER PLAN 14.38 9.88 1.38 1 RTU-1 MDP3-4 ROOF TOP UNIT #1 RTU-2 MDP3-5 RTU-3 MDP3-6 231/250 RTU-4 MDP3-7 204/250 ROOF AC-1 (15A MOCP) AIR CONDITIONER 1 37KW HC SEE MAIN SWBD. "MDP3" - AC-2 (15A MOCP) AIR CONDITIONER 2 37KW - CU-1 (40A MOCP) CONDENSING UNIT 1 20FLA 5 CU-2 (40A MOCP) CONDENSING UNIT 2 20FLA EF-1 - EXHAUST FAN 1 (1/4HP) - EF-2 - EXHAUST FAN 2 (1/4HP) - EF-3 - EXHAUST FAN 3 (1/4HP) EC - EF-4 - EXHAUST FAN 4 (1/6HP) EC - EF-5 - EXHAUST FAN 5 (1/4HP) - ELEV ELEVATOR 30HP EC FP FIRE PUMP 30HP EC 1 2 SL STAGE LIFT 10HP 3 AC-3 AC-4 (45A MOCP) (45A MOCP) AIR CONDITIONER 3 AIR CONDITIONER 4 33.5FLA 33.5FLA CU-3 CU-4 CONDENSING UNIT 3 CONDENSING UNIT 4 19.3FLA 19.3FLA (40A MOCP) (40A MOCP) EF-6 EF-7 EXHAUST FAN 6 EXHAUST FAN 7 (1/4HP) (1/6HP) ROOF TOP UNIT #2 ROOF TOP UNIT #3 ROOF TOP UNIT #4 204/250 231/250 JP JOCKEY PUMP 3/4HP AV 20A-125V DUPLEX RECEPTACLE, NEMA 5-20R, WITH ISOLATED GROUND (18" M.H.). H1 1 250 T4 LAMP 120 GOTHAM # CQ11-250-W-6AR-WLP-STEM-DBL COOPER, KIRLIN H2 1 500 T4 LAMP 120 COOPER, KIRLIN H3 1 400 T4 LAMP 120 COOPER, KIRLIN A 1 400 HPS 120 LSI # HFR5400HPS-120-F 2 B 1 125 MH 120 LSI # HFSH3175MH-120-F 3 GOTHAM # CQ11-250-W-6AR-WLP-STEM-DBL GOTHAM # CQ11-250-W-6AR-WLP-STEM-DBL DP2-1 DP2-2 DP2-4 DP2-8 DP2-9 DP2-19 DP2-21 DP2-22 DP2-23 EP-34 EP-35 EP-36 EP-37 EP-38 EP-39 EP-40 EP-41 EP-42 C 1 100 MH 120 GOTHAM # LAH-100M-12FW-FFL-120 COOPER, KIRLIN WHITE FACE W/RED STENCIL LETTERS 4 GENERAL LEGEND NOTES: A B SEE A/V DRAWINGS FOR LEGEND ON A/V DEVICES. SEE THEATRICAL LIGHTING DRAWINGS FOR LEGEND ON THEATRICAL LIGHTING FIXTURES. HC HC HC HC HC HC HC HC HC HC HC HC HC HC EC EC PC PC HC HC HC HC EC EC EC EC EC EC EC EC HC HC HC HC HC EC EC EC EC HC HC HC HC HC HC HC HC HC HC HC HC EC EC EC EC EC EC EC ROOF ROOF ROOF PROJECTION ROOM PROJECTION ROOM A/V RACK SERVER ROOM ROOF ROOF ROOF ROOF ROOF ROOF ROOF ROOF ROOF ELEV. EQUIP. ROOM FIRE PUMP ROOM MECHANICAL ROOM JAN. CLOSET 109 6KW 6KW DWH1 DWH2 DOM. WATER HEATER 1 DOM. WATER HEATER 2 3 12 12 .75 3 12 12 .75 2 6 8 1 2 6 8 1 3 10 10 .75 3 10 10 .75 3 8 10 .75 3 8 10 .75 5 5 5 2 12 12 .75 2 12 12 .75 2 12 12 .75 2 12 12 .75 2 12 12 .75 2 12 12 .75 2 12 12 .75 3 1 6 1.5 3 1 6 1.5 3 12 12 .75 3 8 10 1.5 3 10 10 .75 3 10 10 .75 6 6 6 6 RTU-5 MDP3-8 ROOF TOP UNIT #5 231/250 ROOF HC HC HC Date: Scale Drawn By Checked By Project Number ARCHITECTURE PLANNING INTERIOR DESIGN STRUCTURAL ENGINEERING 424 East Fourth Street Cincinnati, w w w . c h a r c h Ohio i t e c t s . 45202 c o m tel: 513/241/4474 fax: 513/241/0081 ISSUANCES COMPUTER FILE 1400 West Dorothy Lane Dayton, Ohio 45409-1310 Tel: (937) 224-0861 Fax: (937) 224-5777 3417 South Sherman Drive Beech Grove, IN 46107 Tel: (317) 780-1555 Fax: (317) 780-6525 750 North Orleans, Suite 400 Chicago, IL 60610 Tel: (312) 944-8230 Fax: (312) 944-8297 117 East Washington Street, Suite 200 Indianapolis, IN 46204 Tel: (317) 637-2222 Fax: (317) 637-2260 1137 West Taylor St. Suite 316 Chicago, IL 60607 Tel: (312) 224-8460 Fax: (312) 224-8961 1025 N.Watery Ln. Brigham City, UT 84302 TEL: (453) 723-5000 FAX: (453) 538-5506 6622 Kingspointe Parkway Orlando, FL 33819 Tel: (407) 816-9400 Fax: (407) 816-9300 10.18.07 No. Description Date 1 SCHEMATIC DESIGN 2 3 4 5 6 7 8 11 DESIGN DEVELOPMENT 01.18.08 CD 50% 03.14.08 PERMIT SET 04.25.08 ADDENDUM #2 05.16.08 ADDENDUM #3 05.22.08 ADDENDUM #5 06.04.08 PERMIT SET 06.10.08 CONSTRUCTION SET 08.01.08 12 ASI6 12.23.08 13 PERMIT RE-SUBMISSION 1.28.09 2/3/2009 4:29:02 PM \\DAYDATA1\TEAMDATA\l600\2007-06019\DRAWINGS\2007-06019-Central.rvt E001 LIGHTING FIXTURE SCHEDULE, LEGEND & INDEX OF DRAWINGS New Worship Center Checker Author 05-22-08 2007-06019 ELECTRICAL DRAWING INDEX SHEET DESCRIPTION E001 LIGHTING FIXTURE SCHEDULE, LEGEND & INDEX OF DRAWINGS E002 SITE LIGHTING AND UTILITY PLAN E003 ELECTRICAL DETAILS E100 GATHERING CENTER - DEMO E200 PIT LEVEL - LIGHTING PLAN E201 FIRST FLOOR - LIGHTING PLAN E202 BALCONY ONE - LIGHTING PLAN E203 BALCONY TWO - LIGHTING PLAN E205 CATWALK - NEW WORK - LIGHTING E206 ROOF LIGHTING E300 PIT LEVEL - POWER PLAN E301 FIRST FLOOR - POWER PLAN E301-A FIRST FLOOR - POWER PLAN E302 BALCONY ONE - POWER PLAN E302-A BALCONY ONE - POWER PLAN E303 BALCONY TWO - POWER PLAN E305 CATWALK-POWER PLAN E400 SINGLE-LINE DISTRIBUTION DIAGRAM E401 PANELBOARD SCHEDULES E402 PANELBOARD SCHEDULES E403 PANELBOARD SCHEDULES SKE-1 FIRST FLOOR - POWER PLAN 3417 South Sherman Drive Beech Grove, IN 46107 Tel: (317) 780-1555 Fax: (317) 780-6525 750 North Orleans, Suite 400 Chicago, IL 60610 Tel: (312) 944-8230 Fax: (312) 944-8297 117 East Washington Street, Suite 200 Indianapolis, IN 46204 Tel: (317) 637-2222 Fax: (317) 637-2260 1137 West Taylor St. Suite 316 Chicago, IL 60607 Tel: (312) 224-8460 Fax: (312) 224-8961 1025 N.Watery Ln. Brigham City, UT 84302 TEL: (453) 723-5000 FAX: (453) 538-5506 6622 Kingspointe Parkway Orlando, FL 33819 Tel: (407) 816-9400 Fax: (407) 816-9300 10.18.07 No. Description Date 1 SCHEMATIC DESIGN 2 3 4 5 6 7 8 11 DESIGN DEVELOPMENT 01.18.08 CD 50% 03.14.08 PERMIT SET 04.25.08 ADDENDUM #2 05.16.08 ADDENDUM #3 05.22.08 ADDENDUM #5 06.04.08 PERMIT SET 06.10.08 CONSTRUCTION SET 08.01.08 12 ASI6 12.23.08 13 PERMIT RE-SUBMISSION 1.28.09 1/29/2009 9:55:46 AM C:\Drawings\revit\Northview\2007-06019-Central-local.rvt H301 ROOFTOP EQUIPMENT SECTIONS New Worship Center ARC CSR/GSS 05-22-08 2007-06019 F B Z1 P4 P5 P3 P2 P6 P7 P10 N1 N2 N3 M1 M2 M3 N 1.3 2.1 W W3 W2 W1 P8 P9 2.2 4.2 4.1 P1 T4 T1 T2 T3 T5 S1 S2 S3 S4 S5 A1 A2 J J1 J2 3.1 A. ELEV. S-33 301 S-33 300 S-33 S-34 T RTU-1 32"D 32"D 32"D 32"D G1 - 46 x 34 3130 CFM (2) 16"D 16"D 16"D 16"D 16"D 16"D 16"D 16"D 16"D 16"D 16"D 16"D 14/14 14/14 18/30 18/20 30/18 DN 30/18 DN 28"D 28"D DN 3 32"D DN 2 C-D S C-S C-S B-S A-S C-S 1 1705 CFM 1 1705 CFM 1 1705 CFM 1705 CFM 1 1705 CFM 1 1705 CFM 1 6120 CFM 1 6260 CFM 1 4 4 4 4 4 4 4 4 Date: Scale Drawn By Checked By Project Number ARCHITECTURE PLANNING INTERIOR DESIGN STRUCTURAL ENGINEERING 424 East Fourth Street Cincinnati, w w w . c h a r c h Ohio i t e c t s . 45202 c o m tel: 513/241/4474 fax: 513/241/0081 ISSUANCES COMPUTER FILE 1400 West Dorothy Lane Dayton, Ohio 45409-1310 Tel: (937) 224-0861 Fax: (937) 224-5777 3417 South Sherman Drive Beech Grove, IN 46107 Tel: (317) 780-1555 Fax: (317) 780-6525 750 North Orleans, Suite 400 Chicago, IL 60610 Tel: (312) 944-8230 Fax: (312) 944-8297 117 East Washington Street, Suite 200 Indianapolis, IN 46204 Tel: (317) 637-2222 Fax: (317) 637-2260 1137 West Taylor St. Suite 316 Chicago, IL 60607 Tel: (312) 224-8460 Fax: (312) 224-8961 1025 N.Watery Ln. Brigham City, UT 84302 TEL: (453) 723-5000 FAX: (453) 538-5506 6622 Kingspointe Parkway Orlando, FL 33819 Tel: (407) 816-9400 Fax: (407) 816-9300 10.18.07 No. Description Date 1 SCHEMATIC DESIGN 2 3 4 5 6 7 8 11 DESIGN DEVELOPMENT 01.18.08 CD 50% 03.14.08 PERMIT SET 04.25.08 ADDENDUM #2 05.16.08 ADDENDUM #3 05.22.08 ADDENDUM #5 06.04.08 PERMIT SET 06.10.08 CONSTRUCTION SET 08.01.08 12 ASI6 12.23.08 13 PERMIT RE-SUBMISSION 1.28.09 1/8" = 1'-0" 1/29/2009 9:55:45 AM C:\Drawings\revit\Northview\2007-06019-Central-local.rvt H231 SECOND BALCONY LEVEL FLOOR PLAN - HVAC New Worship Center ARC CSR/GSS 05-22-08 2007-06019 1/8" = 1'-0" 1 SECOND BALCONY LEVEL FLOOR PLAN - HVAC 1 DUCTSOX LOCATED HIGH ABOVE WORSHIP CENTER AND BALCONY. CFM IS INDICATED. 2 RETURN AIR DUCT OPEN TO CHASE. 3 SUPPLY AIR DUCT RISER IN CHASE SERVED BY RTU-1. 4 START DUCT SOX FABRIC DUCTWORK. 5 NOT USED. NOTES 300 BALCONY-2 301 ELEVATOR VESTIBULE S-33 STAIR-3 S-34 STAIR-4 ROOM INDEX X4 X5 X1 0.4 2.4 2.8 3.3 4.4 Y E F B Z2 Z3 Z1 Z4 P4 P5 P3 P2 P6 P7 P10 N1 N2 N3 M1 M2 M3 N 1.3 2.1 W W3 W2 W1 P8 P9 2.2 4.2 N4 M4 4.1 P1 T4 T1 T2 T3 T5 S1 S2 S3 S4 S5 A1 A2 J J1 J2 3.1 A. EF-1 RTU-2 EF-3 EF-2 T G1 - 36 x 8 A-D AC-1 AC-2 U/C EF-4 1 ELEV. 2 2 221 S-21 S-22 S-23 203 200 201 204 S-24 221 S-21 S-22 S-23 203 200 201 204 S-24 221 S-21 S-22 S-23 203 200 201 204 S-24 221 S-21 S-22 S-23 203 200 201 204 S-24 221 S-21 S-22 S-23 203 200 201 204 S-24 221 S-21 S-22 S-23 203 200 201 204 S-24 221 S-21 S-22 S-23 203 200 201 204 S-24 221 S-21 S-22 S-23 203 200 201 204 202 S-24 5 5 5 TYP. 6 7 7 8 A-D G1 - 44 x 44 3780 CFM (2) 1 H003 32"D UP 54/32 DN 28"D UP S3 - 105 CFM 6" (70) 30/18 UP 40/26 DN 30/18 UP 40/26 DN RTU-5 RTU-1 50/34 DN 24"D 24"D 24"D 24"D 24"D 24"D 24"D F1 - x 1500 CFM 36 12 F1 - x 1500 CFM 36 12 24/18 30/16 F1 - x 1500 CFM F1 - x 36 12 1500 CFM 36 12 24/18 30/16 A2 - 6" 150 CFM C-D S 3 2 A-D S S1 - 135 CFM 8" U/C U/C U/C U/C 4 4 Date: Scale Drawn By Checked By Project Number ARCHITECTURE PLANNING INTERIOR DESIGN STRUCTURAL ENGINEERING 424 East Fourth Street Cincinnati, w w w . c h a r c h Ohio i t e c t s . 45202 c o m tel: 513/241/4474 fax: 513/241/0081 ISSUANCES COMPUTER FILE 1400 West Dorothy Lane Dayton, Ohio 45409-1310 Tel: (937) 224-0861 Fax: (937) 224-5777 3417 South Sherman Drive Beech Grove, IN 46107 Tel: (317) 780-1555 Fax: (317) 780-6525 750 North Orleans, Suite 400 Chicago, IL 60610 Tel: (312) 944-8230 Fax: (312) 944-8297 117 East Washington Street, Suite 200 Indianapolis, IN 46204 Tel: (317) 637-2222 Fax: (317) 637-2260 1137 West Taylor St. Suite 316 Chicago, IL 60607 Tel: (312) 224-8460 Fax: (312) 224-8961 1025 N.Watery Ln. Brigham City, UT 84302 TEL: (453) 723-5000 FAX: (453) 538-5506 6622 Kingspointe Parkway Orlando, FL 33819 Tel: (407) 816-9400 Fax: (407) 816-9300 10.18.07 No. Description Date 1 SCHEMATIC DESIGN 2 3 4 5 6 7 8 11 DESIGN DEVELOPMENT 01.18.08 CD 50% 03.14.08 PERMIT SET 04.25.08 ADDENDUM #2 05.16.08 ADDENDUM #3 05.22.08 ADDENDUM #5 06.04.08 PERMIT SET 06.10.08 CONSTRUCTION SET 08.01.08 12 ASI6 12.23.08 13 PERMIT RE-SUBMISSION 1.28.09 1/8" = 1'-0" 1/29/2009 9:55:43 AM C:\Drawings\revit\Northview\2007-06019-Central-local.rvt H221 FIRST BALCONY LEVEL FLOOR PLAN - HVAC New Worship Center ARC CSR/GSS 05-22-08 2007-06019 1/8" = 1'-0" 1 FIRST BALCONY LEVEL FLOOR PLAN - HVAC 1 SUPPLY DUCT FROM RTU-1 TO RISE IN CHASE TO SERVE BALCONY 1 AND BALCONY 2. 2 SUPPLY MAIN TO RUN ABOVE FIRST BALCONY CEILING TO SERVE BALCONY 1 AND ADJACENT ROOMS. 3 RETURN AIR DUCT SERVES RTU-1 - OPEN TO CHASE PLENUM. 4 SMOKE DETECTOR BY E.C. 5 LOCATE ANGULAR JOINTS IN THE CENTER SPACE BETWEEN THE BALCONY STRUCTURAL BEAMS. COORDINATE WITH ARCHITECT PRIOR TO LAYOUT OF DUCT. 6 WALL LOUVER - REFER TO FAN SCHEDULE, DRAWING H001. 7 ROUTE REFRIGERANT PIPING TO CONDENSING UNIT ON ROOF. PROVIDE INSULATION AND SUPPORTS PER MANUFACTURER RECOMMENDATIONS. 8 PROVIDE LINED SHEET METAL TRANSFER DUCT WITH A MINIMU OF 2 - 90 DEG. ELBOWS. DUCT TO BE OPEN TO ELEVATOR MACHINE ROOM. NOTES 200 BALCONY-1 201 VESTIBULE 202 CRYING ROOM 203 MACHINE ROOM 204 MEZZANINE 221 PROJECTION ROOM S-21 STAIR-1 S-22 STAIR-2 S-23 STAIR-3 S-24 STAIR-4 ROOM INDEX L3 P12 P15 X10 X4 X5 X1 0.4 2.4 2.8 3.3 4.4 Y E F B Z2 Z3 Z1 Z4 P4 P5 P3 P2 P6 P7 P10 N1 N2 N3 M1 M2 M3 N 1.3 2.1 W W3 W2 W1 P8 P9 2.2 4.2 N4 M4 4.1 P1 T4 T1 T2 T3 T5 S1 S2 S3 S4 S5 A1 A2 J J1 J2 3.1 A. 50/24 ELEV. UH-1 EF-5 EF-6 U/C U/C U/C K1 - 24 x 12 300 CFM (2) J2 - 12 x 24 J1 - 12 x 24 J2 - 12 x 24 J1 - 12 x 24 K2 - 24 x 12 125 CFM K2 - 24 x 12 235 CFM K2 - 24 x 12 235 CFM K2 - 24 x 12 225 CFM RTU-4 H1 - 12 x 8 100 CFM L S D CU-1 AC-1 L S D CU-2 AC-2 F2 - x 800 CFM 24 10 F2 - x 300 CFM 12 8 (2) T T RTU-2 16"D F2 - x 330 CFM 18 10 (3) F2 - x 125 CFM 12 6 (2) G1 - 12 x 6 (2) K1 - 24 x 12 1000 CFM CU-4 CU-3 EF-3 EF-2 EF-1 U/C U/C T EF-3 A1 - 8" 200 CFM S2 - 100 CFM 6" S2 - 100 CFM 6" S1 - 150 CFM 8" S1 - 150 CFM 8" S1 - 200 CFM 8" S1 - 200 CFM 8" 10"D 12/12 12/6 12/6 12/6 20/8 20/8 12/6 12/12 12/6 12 12 14 14 12 6 RTU-3 1 1 11 RTU-2 1 2 3 9 9 11 10 10 105 106 108 109 102 110 112 113 116 101 S-11 S-12 3 H003 4 H003 105 106 108 109 102 110 112 113 116 101 S-11 S-12 105 106 108 109 102 110 112 113 116 101 S-11 S-12 105 106 108 109 102 110 112 113 116 101 S-11 S-12 105 106 108 109 102 110 112 113 116 101 S-11 S-12 105 106 108 109 102 110 112 113 116 101 S-11 S-12 105 106 108 109 102 110 112 113 116 101 S-11 S-12 105 108 109 102 110 112 113 116 101 S-11 S-12 105 108 109 102 110 112 113 116 101 S-11 S-12 105 108 109 102 110 112 113 116 101 S-11 S-12 105 108 109 102 110 112 113 116 101 120 S-11 S-12 105 107 108 109 102 110 112 111 115 116 117 101 S-13 S-14 104 C-101 119 118 S-11 S-12 103 12 12 15 15 TYP. T RTU-3 16 14' - 8" UH-3 T UH-3 T C-D 40/24 A-D 14' - 8" A1 - 6" 75 CFM 12"D G1 - 48 x 46 4450 CFM (2) G1 - 40 x 40 3750 CFM (2) G1 - 36 x 12 1315 CFM 40/24 48/24 28"D 44/28 40/26 G1 - 48 x 46 4450 CFM (2) 20/34 30/18 UP S3 - 105 CFM 6" (72) A-S A-S 40/26 24"D SA-3 16 7 2 3 2 3 RTU-1 RTU-5 1 1 16 SA-5 SA-6 SA-7 SA-8 4 5 U/C U/C 12/6 8/6 U/C U/C U/C U/C U/C K2 - 24 x 12 125 CFM B-D B-D B-D B-D T RTU-5 1'-10"AFF 1'-10"AFF J1 - 12 x 24 20/8 B-D C-D Date: Scale Drawn By Checked By Project Number ARCHITECTURE PLANNING INTERIOR DESIGN STRUCTURAL ENGINEERING 424 East Fourth Street Cincinnati, w w w . c h a r c h Ohio i t e c t s . 45202 c o m tel: 513/241/4474 fax: 513/241/0081 ISSUANCES COMPUTER FILE 1400 West Dorothy Lane Dayton, Ohio 45409-1310 Tel: (937) 224-0861 Fax: (937) 224-5777 3417 South Sherman Drive Beech Grove, IN 46107 Tel: (317) 780-1555 Fax: (317) 780-6525 750 North Orleans, Suite 400 Chicago, IL 60610 Tel: (312) 944-8230 Fax: (312) 944-8297 117 East Washington Street, Suite 200 Indianapolis, IN 46204 Tel: (317) 637-2222 Fax: (317) 637-2260 1137 West Taylor St. Suite 316 Chicago, IL 60607 Tel: (312) 224-8460 Fax: (312) 224-8961 1025 N.Watery Ln. Brigham City, UT 84302 TEL: (453) 723-5000 FAX: (453) 538-5506 6622 Kingspointe Parkway Orlando, FL 33819 Tel: (407) 816-9400 Fax: (407) 816-9300 10.18.07 No. Description Date 1 SCHEMATIC DESIGN 2 3 4 5 6 7 8 11 DESIGN DEVELOPMENT 01.18.08 CD 50% 03.14.08 PERMIT SET 04.25.08 ADDENDUM #2 05.16.08 ADDENDUM #3 05.22.08 ADDENDUM #5 06.04.08 PERMIT SET 06.10.08 CONSTRUCTION SET 08.01.08 12 ASI6 12.23.08 13 PERMIT RE-SUBMISSION 1.28.09 1/8" = 1'-0" 1/29/2009 11:44:49 AM C:\Drawings\revit\Northview\2007-06019-Central-local.rvt H211 FIRST LEVEL FLOOR PLAN - HVAC New Worship Center ARC CSR/GSS 05-22-08 2007-06019 1/8" = 1'-0" 1 FIRST LEVEL FLOOR PLAN - HVAC 1 ROOFTOP UNIT WITH ROOF CURB ON ROOF. COORDINATE EXACT LOCATION WITH STRUCTURE. 2 SUPPLY AIR DUCT RISES TO SERVE ROOFTOP UNIT ABOVE. COORDINATE RISER LOCATION WITH STRUCTURE. 3 RETURN AIR DUCT RISES TO SERVE ROOFTOP UNIT ABOVE. COORDINATE RISER LOCATION WITH STRUCTURE. 4 RETURN DUCT DROPS TO SERVE WORSHIP CENTER. 5 28"D SUPPLY DUCT RISES TO SERVE STAGE. REFER TO H221 AND H231 FOR CONTINUATION. 6 SUPPLY DUCT TO RISE IN CHASE TO SERVE BALCONY 1 AND BALCONY 2. 7 RETURN DUCT RISES INTO CHASE ABOVE AND TERMINATE APPROX. 12" ABOVE CHASE FLOOR AND TRANSITION TO SOUND ATTENUATOR (SA-4) - OPEN TO CHASE PLENUM. 8 NOT USED. 9 HORIZONTAL INDOOR A/C UNIT - SUPPORT UNIT FROM WALL AND ROOF STRUCTURE WITH TYPE J1 ISOLATORS. LOCATE IN CORNER OF PROJECTION ROOM AT APPROX. 16'-0" A.F.F. 10 EXTEND 1" DRAIN LINE THRU WALL AND TURN DOWN TO ABOVE ROOF AND TERMINATE WITH SPLASH BLOCK. 11 PROVIDE PITCH BOX THRU ROOF FOR REFRIGERANT PIPING TO DROP THRU ROOF TO ABOVE PIT LEVEL CEILING. REFER TO DRAWING H201 FOR CONTINUATION. 12 EXHAUST FAN ON ROOF WITH ROOF CURB. COORDINATE ROOF OPENING WITH STRUCTURE. 13 PROVIDE RETURN AIR SOUND BOOT. REFER TO DETAIL, DRAWING H002. 14 EXISTING HOT WATER CABINET HEATER AND ASSOCIATED PIPING TO REMAIN. 15 LOCATE ANGULAR JOINTS IN THE CENTER SPACE BETWEEN THE BALCONY STRUCTURAL BEAMS. COORDINATE WITH ARCHITECT PRIOR TO LAYOUT OF DUCT. 16 SMOKE DETECTOR BY E.C. NOTES 101 ENTRANCE LOBBY 102 VESTIBULE 103 WORSHIP CENTER 104 SOUND BOOTH 105 CHAIR STORAGE/CATERING 106 VESTIBULE 107 VESTIBULE 108 MEN'S RESTROOM 109 JANITOR ROOM 110 WOMEN'S RESTROOM 111 WOMEN'S RESTROOM 112 VESTIBULE 113 VESTIBULE 115 STORAGE 116 WORKSHOP 117 SIDE PLATFORM 118 DELIVERY 119 PLATFORM 120 SIDE PLATFORM 124 JANITOR C-101 CORRIDOR S-11 STAIR-1 S-12 STAIR-2 S-13 STAIR-3 S-14 STAIR-4 ROOM INDEX 275 CFM A1 - 8" 200 CFM (2) F1 - x 50 CFM 10 6 A1 - 6" 75 CFM A1 - 10" 300 CFM (2) A1 - 8" 200 CFM A1 - 8" 180 CFM A1 - 8" 180 CFM A1 - 8" 180 CFM A1 - 8" 180 CFM CUH-3 CUH-4 4-1 4-3 4-2 4-4 4-5 4-6 4-11 4-14 4-15 10"D 18/14 16"D 14"D 14"D 14"D 24/16 48/20 38/16 28/16 10/10 10/10 10/10 8/8 8/8 12/10 K2 - 8 x 8 150 CFM 10/6 10/6 10/8 K2 - 8 x 8 150 CFM 4-7 8/8 12/10 AC-4 CU-4 L S CU-3 AC-3 S L D 4-9 J1 - 12 x 24 J1 - 12 x 24 J1 - 12 x 24 J1 - 12 x 24 J1 - 12 x 24 J1 - 12 x 24 9 ELEV. T 4 U/C A1 - 12" 425 CFM (4) A1 - 6" 70 CFM T 2 T 3 T 1 T 6 U/C U/C F1 - x 50 CFM 10 6 T 8 7 T T 10 J1 - 12 x 24 4-8 F1 - x 330 CFM 24 8 (3) 18/12 12/12 T 12 T 13 T 11 T 14 T 15 T T T J1 - 12 x 24 J1 - 12 x 24 J1 - 12 x 24 J1 - 12 x 24 J1 - 12 x 24 J1 - 12 x 24 J1 - 12 x 24 10"D A1 - 8" 160 CFM A1 - 8" A1 - 6" 250 CFM 125 CFM G1 - 24 x 12 (2) UH-2 G1 - 24 x 12 (2) T 1 1 1 1 1 1 1 1 1 1 1 1 1 11 7 8 9 10 SA-2 13 12 15 EF-6 17 T EF-6 18 CU-2 EF-5 CU-1 22 22 23 24 EF-7 EP EP EP EP 26 25 A-D 003 002 C-001 004 005 006 007 008 009 010 011 015 016 018 S-02 014 013 C-004 034 023 031 030 028 C-009 C-003 019A 017 018A 003 002 C-001 004 006 007 008 009 010 011 015 016 018 S-02 014A 014 013 C-004 034 023 031 030 028 C-009 C-003 019A 017 018A 003 002 C-001 004 006 007 008 009 010 011 015 016 018 S-02 014A 014 013 C-004 034 023 031 030 028 C-009 C-003 019A 017 018A 003 002 C-001 004 006 007 008 009 010 011 015 016 018 S-02 014A 014 013 C-004 034 023 031 030 028 C-009 C-003 019A 017 018A 003 002 C-001 004 006 007 008 009 010 011 015 016 018 S-02 014A 014 013 C-004 034 023 031 030 028 C-009 C-003 019A 017 018A 003 002 C-001 004 006 007 008 009 010 011 015 016 018 S-02 014A 014 013 C-004 034 023 031 030 028 C-009 C-003 019A 017 018A 003 002 C-001 004 006 007 008 009 010 011 015 016 018 S-02 014A 014 013 C-004 034 023 031 030 028 C-009 C-003 019A 017 018A 003 002 C-001 004 006 007 008 009 010 011 015 016 018 S-02 014A 014 013 C-004 034 023 031 030 028 C-009 C-003 019A 017 018A 003 002 C-001 004 006 007 008 009 010 011 015 016 018 S-02 014A 014 013 C-004 034 023 031 030 028 C-009 C-003 019A 017 018A 003 002 C-001 004 006 007 008 009 010 011 015 016 018 S-02 014A 014 013 C-004 034 023 031 030 028 C-009 C-003 019A 017 018A 003 002 C-001 004 006 007 008 009 010 011 015 016 018 S-02 014A 014 013 C-004 034 023 031 030 028 C-009 C-003 019A 017 018A 003 002 C-001 004 006 007 008 009 010 011 015 016 018 S-02 014A 014 013 C-004 034 023 026 032 031 030 028 C-009 C-003 019A 017 018A 10"D 8"D U/C 5 H003 27 5 T A-D 7' - 0" 6' - 5 3/4" 7' - 0" A-D 7' - 0" 27 A-D U/C 10/10 18/16 14/14 31 31 16/12 31 12/12 31 12/12 31 12/12 31 12/12 31 30/14 J1 - 12 x 24 1 SA-1 B-S J1 - 12 x 24 Date: Scale Drawn By Checked By Project Number ARCHITECTURE PLANNING INTERIOR DESIGN STRUCTURAL ENGINEERING 424 East Fourth Street Cincinnati, w w w . c h a r c h Ohio i t e c t s . 45202 c o m tel: 513/241/4474 fax: 513/241/0081 ISSUANCES COMPUTER FILE 1400 West Dorothy Lane Dayton, Ohio 45409-1310 Tel: (937) 224-0861 Fax: (937) 224-5777 3417 South Sherman Drive Beech Grove, IN 46107 Tel: (317) 780-1555 Fax: (317) 780-6525 750 North Orleans, Suite 400 Chicago, IL 60610 Tel: (312) 944-8230 Fax: (312) 944-8297 117 East Washington Street, Suite 200 Indianapolis, IN 46204 Tel: (317) 637-2222 Fax: (317) 637-2260 1137 West Taylor St. Suite 316 Chicago, IL 60607 Tel: (312) 224-8460 Fax: (312) 224-8961 1025 N.Watery Ln. Brigham City, UT 84302 TEL: (453) 723-5000 FAX: (453) 538-5506 6622 Kingspointe Parkway Orlando, FL 33819 Tel: (407) 816-9400 Fax: (407) 816-9300 10.18.07 No. Description Date 1 SCHEMATIC DESIGN 2 3 4 5 6 7 8 11 DESIGN DEVELOPMENT 01.18.08 CD 50% 03.14.08 PERMIT SET 04.25.08 ADDENDUM #2 05.16.08 ADDENDUM #3 05.22.08 ADDENDUM #5 06.04.08 PERMIT SET 06.10.08 CONSTRUCTION SET 08.01.08 12 ASI6 12.23.08 13 PERMIT RE-SUBMISSION 1.28.09 1/8" = 1'-0" 1/29/2009 9:55:30 AM C:\Drawings\revit\Northview\2007-06019-Central-local.rvt H201 PIT LEVEL FLOOR PLAN - HVAC New Worship Center ARC CSR/GSS 05-22-08 2007-06019 1/8" = 1'-0" 1 PIT LEVEL FLOOR PLAN - HVAC 1 PROVIDE RETURN AIR SOUND BOOT. REFER TO DETAIL, DRAWING H002. 2 NOT USED. 3 NOT USED. 4 NOT USED. 5 NOT USED. 6 NOT USED. 7 40x26 SUPPLY DUCT RISES IN CHASE TO SERVE WORSHIP CENTER. 8 44x28 RETURN DUCT DROPS IN CHASE TO SERVE WORSHIP CENTER AND TERMINATES WITH SOUND ATTENTUATOR SA-2 IN VERTICAL OPEN IN CHASE. CHASE SERVES AS RETURN AIR PLENUM. 9 RETURN AIR DUCT RISES TO SERVE ROOFTOP UNIT (RTU-3) ABOVE. COORDINATE RISER LOCATION WITH STRUCTURE. 10 SUPPLY AIR DUCT RISES TO SERVE ROOFTOP UNIT (RTU-3) ABOVE. COORDINATE RISER LOCATION WITH STRUCTURE. 11 CONDENSING UNIT LOCATED ON ROOF TO SERVE INDOOR UNIT AC-3. ROUTE REFRIGERANT PIPING ABOVE CEILING PER MANUFACTURER'S RECOMMENDATIONS. 12 RETURN AIR DUCT RISES TO SERVE ROOFTOP UNIT (RTU-4) ABOVE. COORDINATE RISER LOCATION WITH STRUCTURE. 13 SUPPLY AIR DUCT RISES TO SERVE ROOFTOP UNIT (RTU-4) ABOVE. COORDINATE RISER LOCATION WITH STRUCTURE. 14 NOT USED. 15 RETURN AIR DUCT EXTENDED TO ABOVE CORRIDOR CEILING - OPEN TO PLENUM. 16 NOT USED. 17 EXHAUST FAN (EF-6) ON ROOF WITH ROOF CURB. COORDINATE ROOF OPENING WITH STRUCTURE. TERMINATE DUCT WITH 0.25" MESH SCREEN AT 8" BELOW ROOF DECK OPEN TO MECH. ROOM. 18 DDC PANEL. 19 NOT USED. 20 NOT USED. 21 NOT USED. 22 CONDENSING UNIT ON ROOF TO SERVE INDOOR A/C UNIT. ROUTE REFRIGERANT PIPING PER MANUFACTURER'S RECOMMENDATIONS. 23 EXHAUST FAN (EF-5) ON ROOF WITH ROOF CURB. COORDINATE ROOF OPENING WITH STRUCTURE FOR EXHAUST LOCATION. 24 CONDENSING UNIT LOCATED ON ROOF TO SERVE INDOOR UNIT AC-4. ROUTE REFRIGERANT PIPING ABOVE CEILING PER MANUFACTURER'S RECOMMENDATIONS. 25 0.75" DRAIN LINE DROPS IN WALL TO HUB DRAIN BELOW SINK. 26 0.75" DRAIN LINE EXTENDS INTO MECH. ROOM AND DROPS ALONG WALL TO NEAREST FLOOR DRAIN. 27 SMOKE DETECTOR BY E.C. 28 NOT USED. 29 NOT USED. 30 NOT USED. 31 TRANSFER AIR DUCT ABOVE CEILING - SIZE LISTED - PROVIDE 90 DEG. ELBOW AND TERMINATE WITH 90 DEG. ELBOW TURNED UP. NOTES 001 STORAGE ROOM 002 SERVER ROOM 003 CONFERENCE ROOM 004 OFFICE 005 BLUE SKY ROOM 006 OFFICE 007 OFFICE 008 OFFICE 009 OFFICE 010 OFFICE 011 OFFICE 013 RECEPTIONIST 014 WAIT/LOBBY 014A SUITE ENTRY 015 WORK STATIONS 016 WORK ROOM 017 CHANGING ROOM WAITING AREA 018 MEN'S CHANGING ROOM 018A MEN'S TOILET 019 WOMEN'S CHANGING ROOM 019A WOMEN'S TOILET 020 MECHANICAL ROOM 021 GREEN ROOM 022 VIDEO CONTROL 023 PRODUCTION RACKS 024 TAPE STORAGE 025 VESTIBULE 026 AUDIO CONTROL 027 VIDEO EDIT 028 STORAGE 029 RECORDING STUDIO 030 VOICE 031 DRUM 032 VESTIBULE 033 TRAP ROOM 034 FIRE PUMP ROOM C-001 CORRIDOR C-003 CORRIDOR C-004 CORRIDOR C-005 CORRIDOR C-007 CORRIDOR C-009 CORRIDOR S-01 STAIR-1 S-02 STAIR-2 S-03 STAIR-3 ROOM INDEX S3 - 105 CFM 6" (3) 24" D Date: Scale Drawn By Checked By Project Number ARCHITECTURE PLANNING INTERIOR DESIGN STRUCTURAL ENGINEERING 424 East Fourth Street Cincinnati, w w w . c h a r c h Ohio i t e c t s . 45202 c o m tel: 513/241/4474 fax: 513/241/0081 ISSUANCES COMPUTER FILE 1400 West Dorothy Lane Dayton, Ohio 45409-1310 Tel: (937) 224-0861 Fax: (937) 224-5777 3417 South Sherman Drive Beech Grove, IN 46107 Tel: (317) 780-1555 Fax: (317) 780-6525 750 North Orleans, Suite 400 Chicago, IL 60610 Tel: (312) 944-8230 Fax: (312) 944-8297 117 East Washington Street, Suite 200 Indianapolis, IN 46204 Tel: (317) 637-2222 Fax: (317) 637-2260 1137 West Taylor St. Suite 316 Chicago, IL 60607 Tel: (312) 224-8460 Fax: (312) 224-8961 1025 N.Watery Ln. Brigham City, UT 84302 TEL: (453) 723-5000 FAX: (453) 538-5506 6622 Kingspointe Parkway Orlando, FL 33819 Tel: (407) 816-9400 Fax: (407) 816-9300 10.18.07 No. Description Date 1 SCHEMATIC DESIGN 2 3 4 5 6 7 8 11 DESIGN DEVELOPMENT 01.18.08 CD 50% 03.14.08 PERMIT SET 04.25.08 ADDENDUM #2 05.16.08 ADDENDUM #3 05.22.08 ADDENDUM #5 06.04.08 PERMIT SET 06.10.08 CONSTRUCTION SET 08.01.08 12 ASI6 12.23.08 13 PERMIT RE-SUBMISSION 1.28.09 1/4" = 1'-0" 1/29/2009 9:55:26 AM C:\Drawings\revit\Northview\2007-06019-Central-local.rvt H003 DETAILS New Worship Center ARC CSR/GSS 05-22-08 2007-06019 1/4" = 1'-0" 3 SECTION 1/4" = 1'-0" 4 SECTION 1/4" = 1'-0" 5 SECTION 1/4" = 1'-0" 1 SECTION 1/4" = 1'-0" 2 SECTION SHUTOFF AND BALANCING VALVE CHECK VALVE D DRAIN PIPE. DIRECTION OF FLOW PITCH DOWN EP EXPANSION TANK PIPE. GENERAL NOTES FANS DUCT CONSTRUCTION & SEALING INDEX OF DRAWINGS AIR DISTRIBUTION DEVICES AIR SUPPLY ROOFTOP UNITS ROOM HEATING UNITS-ELECTRIC COOLING SPLIT SYSTEM COOLING-HEATING SPLIT SYSTEMS SOUND ATTENUATORS AIR CONTROL UNITS - ELECTRIC SHEET DESCRIPTION OUTDOOR UNIT INDOOR UNIT GENERAL CONTRACTOR. WALL LINTEL FOR WALL OPENING BY WHERE REQUIRED FOR DECK SUPPORT AND STEEL FRAMING AROUND ROOF OPENING. PHASE CONSIDERED MINIMUM. MOTOR HORSEPOWERS LISTED ARE TO BE 300 & 301 MEASURED AT 5 FT. FOR P.R.V.'S. SONES VALUES BASED ON A.M.C.A. BULLETINS DESCRIPTION UNIT GENERAL NOTES CONTRACTOR. VERIFY SIZE & COORDINATE WITH GENERAL ROOF & WALL OPENINGS ARE APPROXIMATE. SERVICE SONES STATIC WHEEL MAX. PRESS CFM DIA. MOTOR H.P. VOLT REMARKS APPROX. ROOF/ WALL OPG. CLASS CLASS STRUCT. S.P. CON- SHEET METAL DUCT; INTERIOR LINING; EXTERIOR INSULATION; ETC. REFER TO SPECIFICATIONS FOR DUCT CONSTRUCTION OPTIONS: DUCT SYSTEM LEAKAGE CLASS FOR RECTANGULAR/ROUND METAL DUCT. GENERAL NOTES LEAKAGE S.M.A.C.N.A. CLASS. SEAL REMARKS O.W.B.E. FINISH KEY: "O.W.B.E."-OFF WHITE BAKED ENAMEL, "E.C.L."-ETCHED CLEAR LACQUER OR ANODIZED. SUPPLY AIR DIFFUSERS SHALL BE 4-WAY BLOW UNLESS OTHERWISE NOTED ON DWGS. DESCRIPTION REFER TO SPECIFICATIONS FOR OTHER ALL LAY-IN AIR DEVICES SHALL FIT IN 24"X24" LAY-IN CEILING SYSTEM. SYMBOL GENERAL NOTES MANUFACTURERS. TYPE MOUNTING MATERIAL LAY-IN SURFACE STEEL PROVIDE AUX. FRAMES FOR AIR DEVICES IN PLASTER, GYPSUM BOARD, GLAZED TILE OR CERAMIC TILE SURFACES. FINISH CATALOG NUMBER SEE ACCESSORIES NOTE A1 A2 F1 G1 H1 J1 J2 K1 K2 S1 SUPPLY CLG. SQ. DIFFUSER SUPPLY CLG. SQ. DIFFUSER DOUBLE DEFLECTION SUPPLY REGISTER RETURN GRILLE RETURN/EXHAUST REGISTER RETURN CLG. GRILLE RETURN CLG. GRILLE RETURN CLG. REGISTER RETURN CLG. REGISTER ALUM. PRICE SCDA SCDA 5200 90 530D 80 80 80D 80D --- --- O.B.D. --- O.B.D. --- --- O.B.D. O.B.D. - - - - - - - - - SUPPLY DUCT DOWNSTREAM OF ROOFTOP UNITS (RTU-1,2,3,4,5) SUPPLY DUCT DOWNSTREAM OF VAV REHEAT BOXES RETURN AIR DUCTWORK TRANSFER AIR DUCTWORK GENERAL/TOILET EXHAUST ANY DUCTWORK NOT LISTED ABOVE +3.0" +1.0" -1.0" -1.0" -1.0" +1.0" B C 12/6 24/12 - - - - - - EF-1 EF-2 EF-3 EF-4 AUTOMATIC TEMP. CONTROLS SUBCONTRACTOR A.T.C. H HOT WATER SUPPLY PIPE H HOT WATER RETURN PIPE WATER MAKE-UP PIPE EXISTING PIPE TO REMAIN EXISTING PIPE TO BE REMOVED L REFRIGERANT - LIQUID S REFRIGERANT - SUCTION HG REFRIGERANT - HOT GAS "CONNECT TO EXISTING" SYMBOL - DUCTS OR PIPES A ALL DUCTS AND PIPES TO BE RUN ABOVE CEILING. WHERE NO CEILINGS ARE INSTALLED HOLD TIGHT TO STRUCTURE OR AS NOTED. B THIS CONTRACTOR SHALL COORDINATE THE LOCATION OF ALL THE PIPES, DUCTS, UNITS, ETC. WITH ALL OTHER TRADES. PROVIDE ADJUSTMENTS OR OFF-SETS WHERE NECESSARY. C COORDINATE THE LOCATION OF ALL AIR DEVICES LOCATED IN THE CEILING WITH THE ARCHITECTS REFLECTED CEILING PLAN AND ELECTRICAL LIGHTING PLAN. D SPACE ABOVE CEILING SHALL BE USED AS A RETURN AIR PLENUM. (RTU-4) E ALL EXPOSED DUCTWORK, PIPING, (VAV-REHEAT BOXES, AIR DEVICES SHALL BE GALVANNEALED OR BONDERIZED COATING (PAINT GRIP) IN ORDER TO ACCEPT PAINT. FINISH PAINTING WILL BE DONE BY OTHERS. F BRANCH DUCTS FROM VAV-REHEAT BOXES AND AIR DEVICES SHALL BE SAME SIZE INLET OF UNIT OR DEVICE UNLESS NOTED OTHERWISE. G BRANCH PIPING TO VAV-REHEAT BOXES SHALL BE SAME SIZE INDICATED ON AIR CONTROL UINIT SCHEDULE. H COORDINATE EXPOSED DUCT LOCATIONS WITH ARCHITECTURAL DRAWINGS IN ADDITION TO SPECIFIC HVAC PLAN NOTES. I ALL SQUARE CORNER DUCT FITTINGS, EXCEPT RETURN AIR TRANSFER BOOTS SHALL BE EQUIPPED WITH AIRFOIL TYPE TURNING VANES. J ALL PENETRATIONS FOR ATC DEVICES SHALL BE REPAIRED AND REINSULATED. K ATC COMPONENTS, POINTS, OR HARDWARE NOT SHOWN BUT REQUIRED TO ACHIEVE THE SPECIFIED SEQUENCE OF CONTROL SHALL BE INCLUDED. L THIS CONTRACTOR SHALL COORDINATE WITH AUDIO/VISUAL TECHNOLOGY DRAWINGS FOR ALL CABLE TRAY, CONDUITS, PROJECTORS, ETC. LOCATED ABOVE CEILINGS REQUIRING ACCESS SPACE. M THIS CONTRACTOR SHALL COORDINATE WITH ALL TRADES PRIOR TO TRENCHING, INSTALLATION OF UNDERFLOOR DUCTWORK, BACKFILL AND ALL RISERS THRU FLOOR SLAB. REFER TO DETAILS AND SPECIFICATIONS. N INSTALLATION OF DUCT SOX IN WORSHIP CENTER SHALL BE COORDINATED WITH ALL TRADES AND DUCT SUPPORTS SHALL MEET MF'RS. RECOMMENDATIONS. LEAV. AIR TEMP. (DB/WB) ENT. AIR TEMP. (DB/WB) DX-COOLING TOTAL (MBH) COOLANT SENSIBLE (MBH) ENTERING AIR TEMP. STAGES HEATING COOLING CAPACITIES BASED ON 95 DEG. AMBIENT TEMP. TOTAL S.P.- INCHES W.G. TYPE MOTOR (MIN. H.P.) UNIT CONFIGURATION SUPPLY FAN GAS (CFH) WHEEL TYPE WHEEL DIA. CFM (TOTAL) UNIT NUMBER AREA SERVED UNIT LOCATION GENERAL NOTES MOTOR - 208V - 3 PHASE UNLESS NOTED OTHERWISE. RTU-2 STAGE AREA ROOF SINGLE ZONE-VAV 8,750 4.9"/3.0" 27" PLENUM 15 HP YES BALCONIES ROOF SINGLE ZONE-VAV 4.9"/3.0" 2 @ 27" PLENUM 2 @ 15 HP YES RTU-1 PIT LEVEL ROOMS ROOF DISTRIBUTED-VAV 8,750 4.9"/3.0" 27" PLENUM 15 HP YES RTU-4 427.0 196.0 60.0 128.0 362.0 490.0 80.0 / 67.0 56.1 / 55.7 TOTAL S.P.- INCHES W.G./E.S.P. MOTOR (MIN. H.P.) CFM (MIN./MAX.) 3 NOTE SYMBOL - APPLIES ONLY TO SHEET ON WHICH NOTE IS SHOWN. MINIMUM OUTSIDE AIR CFM ISOLATOR ROOF CURB 4,000 POWER EXHAUST 4,000 / 14,000 2.5" / 1.5" 7.5 APPROX. CABINET DIMENSIONS DESCRIPTION NO. UNIT GENERAL NOTES CFM STAIRS SERVICE LENGTH 66" DEPTH 9" 1,2 RECESS - HEIGHT 750 15 25" NOTES CUH-1 UH-1 UNIT HEATER - HORIZONTAL CABINET UNIT HEATER COST FOR INCREASE OR CHANGE OF ELECTRICAL SERVICE MODEL NO. (OUTDOOR UNIT) BASIS OF DESIGN (MFR. & NO.) MOUNTING VOLTAGE & PHASE DESCRIPTION UNIT NUMBER MAX. FUSE SIZE (FLA / MOP) CAPACITY ENTERING AIR DB REFRIGERANT (LIQUID & SUCTION) REFRIGERANT LIQUID TYPE KW / VOLTAGE HUMIDIFIER TYPE SENSIBLE (MBH) COOLING REFRIGERANT PIPING - SIZES LISTED ARE APPROXIMATE DISCRIPTION FAN MOTOR HP TOTAL (MBH) UNIT CONFIGURATION EXTERNAL S.P. CFM INDOOR UNIT NUMBER AREA SERVED GENERAL NOTES: FOR EQUIPMENT SELECTED SHALL BE BORNE BY H.C. BE VERIFIED BY HVAC CONTRACTOR AND UNIT SUPPLIER. CONTRACTOR. ADEQUACY OF LISTED CIRCUIT SIZES MUST SINGLE POWER SERVICE TO EACH UNIT BY ELECTRICAL. ELECTRIC SERVICES FOR OUTDOOR AND INDOOR UNIT - AC-3 SIZES, NUMBER OF PIPES AND CIRCUITS, ARRANGEMENT, ETC. SHALL BE IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. INDOOR UNIT ENTERING AIR WB HTG. KW / VOLTAGE ELECTRIC REHEAT - (MBH) MODEL NO. (INDOOR UNIT) MAX. FUSE SIZE (FLA / MOP) NOMINAL TONS (APPROX. SIZES) OUTDOOR UNIT VOLTAGE 33.5 FLA / 45.0 MMD36E-A CU-3 CONDENSING UNIT 3.0 19.3 FLA / 40.0 208 / 1 ROOF PFC037A 3/8" & 7/8" R134A LIEBERT 37.2 28.5 80.0 67.0 16.0 4.7 / 208-1 208 / 1 AIR-COOLED HORIZ. CONCEALED 1200 0.4" SPLIT SYSTEM 1/2 A/V RACK EF-5 POWER ROOF VENTILATOR TOILET ROOMS 1095 POWER ROOF VENTILATOR TOILET ROOMS 700 POWER ROOF VENTILATOR STORAGE ROOM SIDEWALL EXHAUSTER POWER ROOF VENTILATOR TOILET ROOMS ELEVATOR EQUIP. ROOM 300 EF-6 POWER ROOF VENTILATOR MECHANICAL ROOM ALUM. E.C.L. 0.5 12" 10.0 1/4 115 1 14.5"x14.5" 1,3 0.5 10" 10.0 1/4 115 1 14.5"x14.5" 1,3 0.375 12" 10.0 1/4 115 1 14.5"x14.5" 1,4 0.25 12" 8.0 1/6 115 1 14.5"x14.5" 2,4 0.5 9" 8.0 1/4 115 1 14.5"x14.5" 1,3 0.5 12" 10.0 1/4 115 1 14.5"x14.5" 1,4 500 1000 1000 STAIRS 500 10 46" 9" 25" - CUH-2 CABINET UNIT HEATER CORRIDOR CUH-3 CABINET UNIT HEATER - UH-2 UNIT HEATER - HORIZONTAL DELIVERY FIRE PUMP ROOM 700 10 27.7 21" 6" 24" - - 700 7.5 20.8 - - TONS - COOLING 40 30 30 14,000 VFD MODULATING GAS HEAT 2 R-410A MISC. UNIT MOUNTED YES DISCONNECT SWITCH YES CONTROL PANEL WITH LON INTERFACE YES ELECTRICAL - (MCA / MOP) UNIT WEIGHTS BASIS OF DESIGN 231.0/250.0 8,000 LBS. YORK "SERIES 40" ELECTRIC SERVICES FOR OUTDOOR UNIT AND INDOOR UNIT - VERIFIED BY HVAC CONTRACTOR AND UNIT SUPPLIER. COST FOR DX-COOLING POWER CCT. (A.) ENTERING AIR TEMP. (WB) BASIS OF DESIGN (MFR.) HOT GAS BY-PASS (APPROXIMATE SIZES) REFRIG. LIQUID & SUCTION VOLTAGE & PHASE POWER CIRCUIT (FLA / MOP) ENTERING AIR TEMP. HEATING OUTPUT (MBH) KW VOLT. PIPE RUNOUT GPM ENTERING AIR TEMP. (DB) MOUNTING NOMINAL TONS DESCRIPTION OUTSIDE AIR LEAVING AIR TEMP. HEATING ELECTRIC COIL COIL WATER HOT WATER PHASE STAGES (MIN.) AUTO VALVE ENTERING IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. OF PIPES AND CIRCUITS, ARRANGEMENT, ETC. SHALL BE AND ARE BASED ON SINGLE CIRCUITING. SIZING, NUMBER REFRIGERANT PIPING - SIZES LISTED ARE APPROXIMATE SENSIBLE (MBH) VOLTAGE & PHASE EXTERNAL S.P./TOTAL UNIT CONFIGURATION DESCRIPTION FAN TOTAL (MBH) MOTOR HP CFM AREA SERVED SYSTEM NUMBER GENERAL NOTES: SINGLE POWER SERVICE TO EACH UNIT BY ELECTRICAL CONTRACTOR. ADEQUACY OF LISTED CIRCUIT SIZES MUST BE INCREASE OR CHANGE OF ELECTRICAL SERVICE FOR MENT SELECTED SHALL BE BORNE BY HVAC CONTRACTOR. EQUIP- AC-1 PROJECTION ROOM CABINET C 7.5 AIR HANDLING DRAW-THRU HORIZONTAL TONS - COOLING AC-2 PROJECTION ROOM CABINET C 7.5 AIR HANDLING DRAW-THRU HORIZONTAL 3,000 0.75" / 2.0" 2 HP 208/3 81.5 69.9 75.0 62.0 3,000 0.75" / 2.0" 2 HP 208/3 81.5 69.9 75.0 62.0 105.3 103 F INDOOR UNIT FAN-ELECTRIC 8.0 FLA / 15.0 MOP / 208-3 0 105.3 103 F 0 CU-1 CU-2 7.5 20.0 / 40.0 208/3 ROOF 7/8" & 3/8" YES AAON 7/8" & 3/8" YES AAON 7.5 20.0 / 40.0 208/3 ROOF 208 3 208 3 AC-4 33.5 FLA / 45.0 MMD36E-A CU-4 CONDENSING UNIT 3.0 19.3 FLA / 40.0 208 / 1 ROOF PFC037A 3/8" & 7/8" R134A LIEBERT 37.2 28.5 80.0 67.0 16.0 4.7 / 208-1 208 / 1 AIR-COOLED HORIZ. CONCEALED 1200 0.4" SPLIT SYSTEM 1/2 SERVER ROOM REFRIGERANT R-410A R-410A STAIRS/CORRIDOR CUH-4 CABINET UNIT HEATER - RTU-3 WORSHIP CENTER ROOF SINGLE ZONE-VAV 14,000 40 NO. SERVICE UNIT REMARKS L W H SIZE CFM S.P. MAX SA-1 RTU-3 SUPPLY CEILING SLOT DIFFUSER-48" LONG-1 SLOT S2 CEILING SLOT DIFFUSER-24" LONG-1 SLOT 60 40 26 8,900 0.25" SA-2 RTU-3 RETURN 60 44 28 8,900 0.25" 70 F 70 F LEAVING AIR TEMP. (DB / WB) 52.7 / 52.1 52.7 / 52.1 8.0 FLA / 15.0 MOP / 208-3 F2 SPIRAL DUCT GRILLE SDGE --- TBDI-2100 INSUL. PLENUM TBDI-2100 INSUL. PLENUM - - EF-7 SIDEWALL EXHAUSTER FIRE PUMP ROOM 500 0.25 12" 8.0 1/6 115 1 14.5"x14.5" 2,4 REMARKS 1 PROVIDE FAN WITH 12" HIGH ROOF CURB AND DISCONNECT SWITCH. 2 PROVIDE FAN WITH WALL COLLAR, MOTOR SIDE GUARD, DAMPER AND TERMINATE WITH WALL LOUVER. LOUVER EQUAL TO GREENHECK MODEL "EDJ-430". 3 FAN SHALL BE CONTROLLED BY DDC. PROVIDE OCCUPIED/UNOCCUPIED SCHEDULE. 4 FAN SHALL BE CONTROLLED BY LINE VOLTAGE THERMOSTAT, FURNISHED BY H.C. AND INSTALLED BY E.C. -- -- SA-3 RTU-1 SUPPLY 60 54 32 14,000 0.25" -- -- SA-4 RTU-1 RETURN 60 50 34 14,000 0.25" -- -- SA-5 RTU-2 SUPPLY 60 50 24 8,900 0.25" SA-6 RTU-2 RETURN 60 48 24 8,900 0.25" VFD'S FOR FANS ARE UNIT MOUNTED. TOTAL (MBH) 427.0 T THERMOMETER WITH THERMOWELL. GAS DELIVERY PRESSURE - 7" W.C. UH-3 UNIT HEATER - HORIZONTAL STORAGE AREA 700 10 27.7 208 3 - - INLET "C.V.R." CONSTANT VOLUME REHEAT. "V.V.R." VARIABLE VOLUME REHEAT; TYPES - "V.V." VARIABLE VOLUME; UNIT NO. TYPE DIA. GENERAL NOTES PHASE REHEAT COILS CAPACITY BASED ON WINTER MIN. CFM KW CFM MIN. WINTER MAX. MIN. SUMMER REHEAT COIL STAGES VOLT. SEE NOTE ELEC. SERVICE TO THREE-PHASE UNITS TO BE THREE-WIRE UNLESS NOTED VERIFY/COORDINATE CABINET DIMENSIONS, MOUNTING AND RECESS REQUIREMENTS WITH ARCHITECTURAL DWGS. PRIOR TO ORDERING. RECESSED UNITS TO HAVE FOUR(4) SIDE OVER LAP UNLESS OTHERWISE NOTED BY GEN. CONT'R. LINTELS IN MASONRY WALLS FOR FULL & SEMI-RECESSED UNIT WALL OPENING PROVIDED THREE(3) PHASE COIL LOADS SHALL BE DIVIDED EVENLY ACROSS EACH PHASE. KW ELEC. SERVICE AMP VOLT PHASE 21" 6" 24" 21" 6" 24" 52.6 208 3 NOTES 1 TOP SUPPLY GRILLE; FRONT BOTTOM RETURN GRILLE 1,2 1,2 1,2 35.1 208 3 750 15 52.6 208 3 66" 9" 25" 750 15 52.6 208 3 66" 9" 25" C 24/12 C 24/12 C 24/12 C 24/12 34.0 / SCR 208 / 3 34.0 / SCR 208 / 3 95.0 A. 95.0 A. SA-7 RTU-5 SUPPLY 60 40 26 10,100 0.25" SA-8 RTU-5 RETURN 60 44 28 10,100 0.25" RTU-5 WORSHIP CENTER ROOF SINGLE ZONE-VAV 14,000 40 S3 CEILING SLOT DIFFUSER-24" LONG, TBDI-2100 INSUL. PLENUM - 2-SLOT, 1.5" SLOT WIDTH -- -- 4.9"/3.0" 2 @ 27" PLENUM 2 @ 15 HP YES 4.9"/3.0" 2 @ 27" PLENUM 2 @ 15 HP YES UNIT DIMENSIONS 255"L x 92"W x 64"H DEMAND VENTILATION ON SPACE OR RET. AIR C02 LEVELS YES UNIT 60.0 MODULATING GAS HEAT 2 60.0 MODULATING GAS HEAT 2 60.0 MODULATING GAS HEAT 2 60.0 MODULATING GAS HEAT 2 196.0 128.0 427.0 427.0 427.0 427.0 362.0 490.0 80.0 / 67.0 56.1 / 55.7 R-410A 362.0 490.0 80.0 / 67.0 56.1 / 55.7 R-410A 80.0 / 67.0 56.1 / 55.7 R-410A 80.0 / 67.0 56.1 / 55.7 R-410A 285.0 350.0 285.0 350.0 2,200 / 8,750 2.2" / 1.5" 7.5 4,000 / 14,000 2.5" / 1.5" 7.5 2,200 / 8,750 2.2" / 1.5" 7.5 4,000 / 14,000 2.5" / 1.5" 7.5 2,200 YES YES YES 204.0/250.0 6,000 LBS. YORK "SERIES 40" YES 4,000 YES YES YES 231.0/250.0 8,000 LBS. YORK "SERIES 40" 255"L x 92"W x 64"H YES 2,200 YES YES YES 204.0/250.0 6,000 LBS. YORK "SERIES 40" YES 4,000 YES YES YES 231.0/250.0 8,000 LBS. YORK "SERIES 40" 255"L x 92"W x 64"H YES 2 INTEGRAL THERMOSTAT. H001 LEGEND, GENERAL NOTES, AND SCHEDULES DETAILS H201 PIT LEVEL FLOOR PLAN H211 FIRST LEVEL FLOOR PLAN H221 FIRST LEVEL BALCONY FLOOR PLAN H231 SECOND LEVEL BALCONY FLOOR PLAN H301 ROOFTOP EQUIPMENT SECTIONS H002 DETAILS H003 DETAILS H101 EXISTING FIRST LEVEL PLAN-DEMOLITION 4-1 V.V.R. 4-2 4-3 4-4 4-5 4-6 4-7 4-8 4-9 4-10 4-11 4-12 4-13 4-14 4-15 12" 1325 690 200 10 - V.V.R. 12" 1275 640 195 10 - V.V.R. 12" 1200 600 180 9 208 3 - V.V.R. 14" 1770 885 270 13 208 3 - V.V.R. 6" 350 175 55 3 3 - V.V.R. 10" 915 460 140 7 3 - V.V.R. 8" 450 300 70 6 3 - V.V.R. 10" 1000 700 150 14 3 - V.V.R. 6" 275 150 45 2 3 - V.V.R. 8" 535 280 85 4 3 - V.V.R. 6" 285 145 45 2 3 - V.V.R. 200 100 30 1.5 3 - V.V.R. 200 100 30 1.5 3 - V.V.R. 380 190 60 3 3 - V.V.R. 300 250 45 4 3 - 6" 6" 6" 6" 208 208 208 208 208 208 208 208 208 208 208 208 3 SCR 208 3 SCR SCR SCR SCR SCR SCR SCR SCR SCR SCR SCR SCR SCR SCR DATA PENDING RESUBMITTAL OF ROOFTOP SHOP DWGS RETURN TRANSFER DUCTWORK/SOUND BOOTS RETURN DUCT UPSTREAM OF ROOFTOP UNITS (RTU-1,2,3,4 & 5) INTERIOR DESIGN AREA SUPPLY DUCT DOWNSTREAM OF ROOFTOP UNITS (RTU-1,2,3,4 & 5) LINED EXTERNAL NOTES INSULATION SUPPLY DUCT DOWNSTREAM OF VAV REHEAT BOXES-RECTANGULAR DUCT GENERAL/TOILET EXHAUST SUPPLY DUCT DOWNSTREAM OF VAV REHEAT BOXES-ROUND RETURN DUCTWORK NOTES 1 REFER TO SPECIFICATIONS. 23 07 13 1 1 1 1 1 1 -3 DEG. DB WINTER 75 DEG. WB SUMMER 91 DEG. DB SUMMER OUTSIDE DESIGN TEMPERATURES DESIGN ALTITUDE 792 FT. ALL AREAS EXCEPT LISTED BELOW INTERIOR DESIGN AREA WINTER DB % HUMIDITY DB 75 50 SUMMER % HUMIDITY N/A ELEC./TECH. RM./IT CLOSETS 80 50 N/A N/A WORSHIP CENTER 75 50 N/A RECORDING STUDIO 75 50 N/A VIDEO/AUDIO CONTROL 75 50 N/A BALCONY 1&2 75 50 72 N/A 72 72 72 72 1 SUPPLY DUCTSOX 2 2 INSULATION FOR DUCTSOX TO MEET APPLICATION AND PER MF'R. RECOMMENDATION. LEGEND DUCT INSULATION SCHEDULE HVAC DESIGN DATA Date: Scale Drawn By Checked By Project Number ARCHITECTURE PLANNING INTERIOR DESIGN STRUCTURAL ENGINEERING 424 East Fourth Street Cincinnati, w w w . c h a r c h Ohio i t e c t s . 45202 c o m tel: 513/241/4474 fax: 513/241/0081 ISSUANCES COMPUTER FILE 1400 West Dorothy Lane Dayton, Ohio 45409-1310 Tel: (937) 224-0861 Fax: (937) 224-5777 3417 South Sherman Drive Beech Grove, IN 46107 Tel: (317) 780-1555 Fax: (317) 780-6525 750 North Orleans, Suite 400 Chicago, IL 60610 Tel: (312) 944-8230 Fax: (312) 944-8297 117 East Washington Street, Suite 200 Indianapolis, IN 46204 Tel: (317) 637-2222 Fax: (317) 637-2260 1137 West Taylor St. Suite 316 Chicago, IL 60607 Tel: (312) 224-8460 Fax: (312) 224-8961 1025 N.Watery Ln. Brigham City, UT 84302 TEL: (453) 723-5000 FAX: (453) 538-5506 6622 Kingspointe Parkway Orlando, FL 33819 Tel: (407) 816-9400 Fax: (407) 816-9300 10.18.07 No. Description Date 1 SCHEMATIC DESIGN 2 3 4 5 6 7 8 11 DESIGN DEVELOPMENT 01.18.08 CD 50% 03.14.08 PERMIT SET 04.25.08 ADDENDUM #2 05.16.08 ADDENDUM #3 05.22.08 ADDENDUM #5 06.04.08 PERMIT SET 06.10.08 CONSTRUCTION SET 08.01.08 12 ASI6 12.23.08 13 PERMIT RE-SUBMISSION 1.28.09 1/29/2009 11:44:41 AM C:\Drawings\revit\Northview\2007-06019-Central-local.rvt H001 LEGEND, GENERAL NOTES, AND SCHEDULES New Worship Center ARC CSR/GSS 05-22-08 2007-06019 B1 1.5" 1.5" 3" 1.5" 1.5" 2" 2" 3" 2" 1.5" 4" 4" 4" 4" 4" 4" 4" 4" B2 PIT WALL BUILDING CO 4" 4" 4" F2 FD2 FD2 D1 4" 4" 3" PIT PIT 2" 2" 2" 1.5" 2" MATCHLINE "A" MATCHLINE "A" 4" 4" 4" 2" PIT PIT PIT PIT PIT PIT PIT 2" HUB DRAIN B1 CO B2 A3 A4 B2 G1 F1 1.5" 1.5" 1.5" 1.5" 1.5" 1.5" 1.5" 1.5" 1.5" 1.5" 1.5" 1.5" 1.5" 2" 2" 3" 2" 3" 2" 2" 2" 3" 3" 3" 3" 2" 2" 2" 3" 4" 4" 2" PIT NOTE: PROVIDE P-TRAPS ON FIXTURES AND DRAINS AS SPECIFIED ON DRAWINGS AND AS REQUIRED BY CODE. 4" 4" CO 3" VTR FD2 4" 4" 4" 2" 2" 1ST CO CO CO FD2 FD2 FD2 4" 4" 4" 4" 4" FD1 3" FD1 3" C1 2" 1ST 1.5" G1 CO B2 B2 2" 2" 2" 2" 2" FD1 FD1 4" 4" 4" A1 A1 1.5" 1.5" 1.5" 1.5" 3" 3" 1ST 1ST CO 4" BUILDING WALL 4" 3" 2" 2" 2" 4" 4" 4" 4" 4" A2 A2 A2 A2 A2 A2 A2 4" 4" 4" 4" 1.5" 1.5" 2" 1.5" 1.5" 1.5" 1.5" 2" 2" A1 B1 B1 B1 B1 B1 1ST 3" 2" FD1 FD1 3" 3" 4" 4" A2 Date: Scale Drawn By Checked By Project Number ARCHITECTURE PLANNING INTERIOR DESIGN STRUCTURAL ENGINEERING 424 East Fourth Street Cincinnati, w w w . c h a r c h Ohio i t e c t s . 45202 c o m tel: 513/241/4474 fax: 513/241/0081 ISSUANCES COMPUTER FILE 1400 West Dorothy Lane Dayton, Ohio 45409-1310 Tel: (937) 224-0861 Fax: (937) 224-5777 3417 South Sherman Drive Beech Grove, IN 46107 Tel: (317) 780-1555 Fax: (317) 780-6525 750 North Orleans, Suite 400 Chicago, IL 60610 Tel: (312) 944-8230 Fax: (312) 944-8297 117 East Washington Street, Suite 200 Indianapolis, IN 46204 Tel: (317) 637-2222 Fax: (317) 637-2260 1137 West Taylor St. Suite 316 Chicago, IL 60607 Tel: (312) 224-8460 Fax: (312) 224-8961 1025 N.Watery Ln. Brigham City, UT 84302 TEL: (453) 723-5000 FAX: (453) 538-5506 6622 Kingspointe Parkway Orlando, FL 33819 Tel: (407) 816-9400 Fax: (407) 816-9300 10.18.07 No. Description Date 1 SCHEMATIC DESIGN 2 3 4 5 6 7 8 11 DESIGN DEVELOPMENT 01.18.08 CD 50% 03.14.08 PERMIT SET 04.25.08 ADDENDUM #2 05.16.08 ADDENDUM #3 05.22.08 ADDENDUM #5 06.04.08 PERMIT SET 06.10.08 CONSTRUCTION SET 08.01.08 12 ASI6 12.23.08 13 PERMIT RE-SUBMISSION 1.28.09 1/28/2009 8:40:12 AM C:\Drawings\revit\Northivew Church\2007-06019-Central-LOCAL.rvt P300 SOIL, WASTE AND VENT DIAGRAM New Worship Center TWN ATM 05-22-08 2007-06019 F.E.C. RD3 2,560 SQ.FT. RD2 1,790 SQ.FT. RD3 2,660 SQ.FT. RD3 3,075 SQ.FT. RD3 3,340 SQ.FT. RD1 1,030 SQ.FT. RD2 2,140 SQ.FT. RD2 2,190 SQ.FT. RD3 3,170 SQ.FT. RD4 4,615 SQ.FT. RD2 1,360 SQ.FT. RD2 1,530 SQ.FT. RD5 9,550 SQ.FT. RD5 8,965 SQ.FT. VTR VTR VTR VTR VTR VTR SCUPPER SCUPPER RD1 400 SQ.FT. RD1 500 SQ.FT. Date: Scale Drawn By Checked By Project Number ARCHITECTURE PLANNING INTERIOR DESIGN STRUCTURAL ENGINEERING 424 East Fourth Street Cincinnati, w w w . c h a r c h Ohio i t e c t s . 45202 c o m tel: 513/241/4474 fax: 513/241/0081 ISSUANCES COMPUTER FILE 1400 West Dorothy Lane Dayton, Ohio 45409-1310 Tel: (937) 224-0861 Fax: (937) 224-5777 3417 South Sherman Drive Beech Grove, IN 46107 Tel: (317) 780-1555 Fax: (317) 780-6525 750 North Orleans, Suite 400 Chicago, IL 60610 Tel: (312) 944-8230 Fax: (312) 944-8297 117 East Washington Street, Suite 200 Indianapolis, IN 46204 Tel: (317) 637-2222 Fax: (317) 637-2260 1137 West Taylor St. Suite 316 Chicago, IL 60607 Tel: (312) 224-8460 Fax: (312) 224-8961 1025 N.Watery Ln. Brigham City, UT 84302 TEL: (453) 723-5000 FAX: (453) 538-5506 6622 Kingspointe Parkway Orlando, FL 33819 Tel: (407) 816-9400 Fax: (407) 816-9300 10.18.07 No. Description Date 1 SCHEMATIC DESIGN 2 3 4 5 6 7 8 11 DESIGN DEVELOPMENT 01.18.08 CD 50% 03.14.08 PERMIT SET 04.25.08 ADDENDUM #2 05.16.08 ADDENDUM #3 05.22.08 ADDENDUM #5 06.04.08 PERMIT SET 06.10.08 CONSTRUCTION SET 08.01.08 12 ASI6 12.23.08 13 PERMIT RE-SUBMISSION 1.28.09 1/29/2009 10:58:15 AM C:\Drawings\revit\Northivew Church\2007-06019-Central-LOCAL.rvt P206 ROOF PLAN New Worship Center TWN ATM 05-22-08 2007-06019 GENERAL NOTES A REFER TO DETAILS, DIAGRAMS AND SCHEDULES FOR PIPING AND PIPE SIZES NOT SHOWN. B PC SHALL COORDINATE INSTALLATION CAREFULLY WITH ALL OTHER TRADES. NOTES 1 EXHAUST FAN BY HC. 2 ROOFTOP UNIT BY HC. 3 FLUES BY HC. 4 CONDENSING UNIT BY HC. 5 PROVIDE ROOF PENETRATION PIPE CURB. 6 PROVIDE VALVE, DIRT LEG, REGULATOR, UNION AND CONNECT TO UNIT. REGULATOR SHALL BE SIZED FOR 2 PSI INLET PRESSURE AND 7" W.C. DELIVERY. 1 ,035 S Q .TF . R 5D 9 ,055 S Q .TF . R 5D 8 ,569 S Q .TF . V RT V RT V RT V RT V RT V RT S UC PP RE S UC PP RE R 1D 4 00 QS .TF . R 1D 5 00 QS .TF . DN DN UP UP DN UP UP DN F.E.C. F.E.C. F.E.C. F.E.C. DN UP DN D N R O F R D A C EC SS H TA HC S UC PP RE S UC PP RE S UC PP RE S UC PP RE S UC PP RE S UC PP RE S UC PP RE S UC PP RE S UC PP RE S UC PP RE S UC PP RE S UC PP RE A C EC SS H TA HC S M O K H E CTA SEH S UC PP RE 1 1 1 2 2 1 4 4 1 1 2 2 3 4 R UT 53 2 HFC R UT 2 5 33 HFC 2 R UT 5 33 HFC 2 R UT 22 35 HFC F .E .C R 2 ,065 S 3D Q .TF . R 2D 1 ,097 S Q .TF . R 2 ,066 S 3D Q .TF . R 3D 3 ,570 S Q .TF . R 3D 3 ,043 S Q .TF . R 1D 1 ,030 S Q .TF . R 2D 2 ,041 S Q .TF . R 2D 2 ,091 S Q .TF . R 3D 3 ,071 S Q .TF . R 4D 4 ,516 S Q .TF . R 1 ,063 S 2D Q .TF . R 2D 1 ,035 S Q .TF . R 5D 9 ,055 S Q .TF . R 5D 8 ,569 S Q .TF . V RT V RT V RT V RT V RT V RT S UC PP RE S UC PP RE R 1D 4 00 QS .TF . R 1D 5 00 QS .TF . FDV FDV 4" FR 4" FR FCE1 4" FR UP 2.5" FR DN A2 A2 A2 A2 A2 A2 A2 B1 B1 B1 B2 B2 A1 A1 D1 B1 A2 B1 B1 C1 C2 C2 A2 4" FIRE 6" FR FCE2 FCE2 FCE1 4" FR VTR D2 C2 FD1 VR VR VR VR FD1 3" STORM 6" DS 7,945 SQ.FT. 2" GAS UP THRU ROOF FD1 A1 5" STORM VTR VR FIRE PUMP TEST HEADER FROM FDC CHECK VALVE 4" FDC RD1 1,030 SQ.FT. 8" DS 8" DS 11,735 SQ.FT. 11,105 SQ.FT. FD2 1 2 7 WH 3,075 SQ.FT. 6" STORM 3" STORM 0.75" DCW 6" FIRE 0.75" DCW 3,340 SQ.FT. 0.5" DCW & DHW 1" DCW 0.75" DHWR 0.75" DHW 1" DCW 6" FIRE 2" SPRINKLER DRAIN 5 WH 5" DS 4,350 SQ.FT. 0.75" DCW 4" FIRE 0.75" DHWR 0.75" DHW 1" DCW 6" FIRE 4" DS 1,790 SQ.FT. 2.5" DCW FROM BELOW 4 4" STORM RD3 5" STORM 5" DS 2,260 SQ.FT. RD3 2,660 SQ.FT. 5" STORM 1.25" 4 1" 3 1.5" 9 8 6 1.25" DCW 1.5" DCW 1.25" DHW 0.75" DHWR 4" FIRE 1.5" DCW 10 10 10 VTR VTR 13 2" 3 6 0.75" DCW WH 2.5" DCW 1" DHW 0.75" DHWR 4" FIRE 1.5" DCW 2.5" DCW 1.25" DHW 0.75" DHWR 2,560 SQ.FT. 11 S S 11 2" SD G1 C2 RD1 500 SQ.FT. 3" STORM B1 B1 FD1 CO RD3 RD3 5" STORM 2" GAS FROM BELOW 13 FD1 A1 Date: Scale Drawn By Checked By Project Number ARCHITECTURE PLANNING INTERIOR DESIGN STRUCTURAL ENGINEERING 424 East Fourth Street Cincinnati, w w w . c h a r c h Ohio i t e c t s . 45202 c o m tel: 513/241/4474 fax: 513/241/0081 ISSUANCES COMPUTER FILE 1400 West Dorothy Lane Dayton, Ohio 45409-1310 Tel: (937) 224-0861 Fax: (937) 224-5777 3417 South Sherman Drive Beech Grove, IN 46107 Tel: (317) 780-1555 Fax: (317) 780-6525 750 North Orleans, Suite 400 Chicago, IL 60610 Tel: (312) 944-8230 Fax: (312) 944-8297 117 East Washington Street, Suite 200 Indianapolis, IN 46204 Tel: (317) 637-2222 Fax: (317) 637-2260 1137 West Taylor St. Suite 316 Chicago, IL 60607 Tel: (312) 224-8460 Fax: (312) 224-8961 1025 N.Watery Ln. Brigham City, UT 84302 TEL: (453) 723-5000 FAX: (453) 538-5506 6622 Kingspointe Parkway Orlando, FL 33819 Tel: (407) 816-9400 Fax: (407) 816-9300 10.18.07 No. Description Date 1 SCHEMATIC DESIGN 2 3 4 5 6 7 8 11 DESIGN DEVELOPMENT 01.18.08 CD 50% 03.14.08 PERMIT SET 04.25.08 ADDENDUM #2 05.16.08 ADDENDUM #3 05.22.08 ADDENDUM #5 06.04.08 PERMIT SET 06.10.08 CONSTRUCTION SET 08.01.08 12 ASI6 12.23.08 13 PERMIT RE-SUBMISSION 1.28.09 1/8" = 1'-0" 1/28/2009 8:39:36 AM C:\Drawings\revit\Northivew Church\2007-06019-Central-LOCAL.rvt P203 FIRST LEVEL - NEW WORK New Worship Center TWN ATM 05-22-08 2007-06019 GENERAL NOTES A ALL PIPING SHOWN IS LOCATED ABOVE SUSPENDED CEILINGS (AT THE UNDERSIDE OF STRUCTURE IN EXPOSED STRUCTURAL AREAS) UNLESS INDICATED OTHERWISE. B REFER TO DETAILS, DIAGRAMS AND SCHEDULES FOR PIPING AND PIPE SIZES NOT SHOWN. C PC SHALL COORDINATE INSTALLATION CAREFULLY WITH ALL OTHER TRADES. D ANNULAR SPACE OF PIPE, CONDUIT AND OTHER SIMILAR PENETRATIONS OF FIRE RATED ASSEMBLIES SHALL BE FIRESTOPPED. IN ADDITION,PENETRATIONS THRU 0-HOUR RATED FLOORS SHALL ALSO BE FIRESTOPPED TO RETARD PASSAGE OF FIRE AND SMOKE. REFER TO ARCHITECTURAL DRAWINGS FOR CONSTRUCTION, LAYOUT AND FIRE RATINGS OF FLOORS, WALLS, PARTITIONS AND OTHER BUILDING ELEMENTS. E FINISHED FLOOR ELEVATION: FIRST LEVEL - 817.64' F PROVIDE INDIVIDUAL SHUT-OFF VALVES FOR EACH FIXTURE AND/OR FOR EACH PIPE DROPPING TO EACH GROUP OF FIXTURES AS REQURED. NOTES 1 SPRINKLER FLOOR CONTROL VALVE BY FSC. SEE DETAIL A ON SHEET P001. 2 TO SPRINKLERS SERVING FIRST FLOOR. COORDINATE LOCATIONS OF ALL SPRINKLER PIPING AND DEVICES CAREFULLY WITH ALL OTHER TRADES. 3 DCW PIPING TO DROP IN CHASE. PROVIDE FULL SIZE MANIFOLD AND SERVE EACH WATER CLOSET FLUSH VALVE INDIVIDUALLY FROM MANIFOLD. 4 DCW PIPING TO DROP IN CHASE. PROVIDE FULL SIZE MANIFOLD AND SERVE EACH URINAL FLUSH VALVE INDIVIDUALLY FROM MANIFOLD. 5 SPRINKLER DRAIN PIPING TO DROP TO NEAR FLOOR LEVEL. PIPING SHALL EXIT BUILDING 6" A.F.F. AND ELBOW DOWN. PROVIDE CONCRETE SPLASHBLOCK BELOW OUTLET. 6 0.75" DCW AND DHW TO DROP IN CHASE AND SERVE LAVATORIES. 7 PIPING TO DROP IN CHASE AND SERVE HOSE BIBB MOUNTED 36" A.F.F. PROVIDE TRAP PRIMER NEAR CEILING. DISCHARGE PIPING TO DROP IN CHASE TO BELOW FLOOR AND SERVE ADJACENT FLOOR DRAIN. 8 PROVIDE FLOW CONTROLLER IN PLUMBING HOT WATER RETURN PIPING. EACH FLOW CONTROLLER SHALL BE 0.75" SIZE AND FLOW 1 GPM EACH. 9 FIRST LEVEL DOMESTIC WATER HEATER. SEE DETAIL ON SHEET P002. 10 PROVIDE TRAP PRIMER FLUSH TUBE AS MANUFACTURED BY FLUSH VALVE MANUFACTURER. DISCHARGE PIPING SHALL DROP IN CHASE TO BELOW FLOOR AND SERVE ADJACENT FLOOR DRAIN. 11 RISER ISOLATION VALVE WITH SUPERVISORY ATTACHMENT BY FSC. 12 2" PUMPED DISCHAGE FROM ELEVATOR PIT SUMP PUMP TO RISE UP TIGHT TO WALL AND DISCHARGE OVER MOP BASIN. 13 1.25" DCW AND 0.5" DHW TO DROP IN CHASE AND SERVE WATER CLOSET AND LAVATORY. 0.5" DHW 1.5" DCW, 1" DHW & 0.75" DHWR FROM BELOW 0.5" DHW 0.5" DCW WH 0.75" DCW 0.75" DCW 1" DCW 1.25" DCW 1.5" DCW 0.75" DHW 0.75" DHWR 0.75" DHW 1" DHW 8" DS 11,105 SQ.FT. 8" STORM VTR 1,530 SQ.FT. RD2 4" STORM 4" STORM 8"DS 25,735 SQ.FT. 8" DS 11,735 SQ.FT. RD2 1,360 SQ.FT. 8" STORM 9 9 11 12 13 D3 13 8 FD2 FD2 FD2 6" FIRE 4" FIRE 6 7 S FS S FD1 FD1 14 RD1 400 SQ.FT. 3" STORM 3" DS 400 SQ.FT. 2" GAS UP 2" GAS 1.5" GAS UP THRU ROOF Date: Scale Drawn By Checked By Project Number ARCHITECTURE PLANNING INTERIOR DESIGN STRUCTURAL ENGINEERING 424 East Fourth Street Cincinnati, w w w . c h a r c h Ohio i t e c t s . 45202 c o m tel: 513/241/4474 fax: 513/241/0081 ISSUANCES COMPUTER FILE 1400 West Dorothy Lane Dayton, Ohio 45409-1310 Tel: (937) 224-0861 Fax: (937) 224-5777 3417 South Sherman Drive Beech Grove, IN 46107 Tel: (317) 780-1555 Fax: (317) 780-6525 750 North Orleans, Suite 400 Chicago, IL 60610 Tel: (312) 944-8230 Fax: (312) 944-8297 117 East Washington Street, Suite 200 Indianapolis, IN 46204 Tel: (317) 637-2222 Fax: (317) 637-2260 1137 West Taylor St. Suite 316 Chicago, IL 60607 Tel: (312) 224-8460 Fax: (312) 224-8961 1025 N.Watery Ln. Brigham City, UT 84302 TEL: (453) 723-5000 FAX: (453) 538-5506 6622 Kingspointe Parkway Orlando, FL 33819 Tel: (407) 816-9400 Fax: (407) 816-9300 10.18.07 No. Description Date 1 SCHEMATIC DESIGN 2 3 4 5 6 7 8 11 DESIGN DEVELOPMENT 01.18.08 CD 50% 03.14.08 PERMIT SET 04.25.08 ADDENDUM #2 05.16.08 ADDENDUM #3 05.22.08 ADDENDUM #5 06.04.08 PERMIT SET 06.10.08 CONSTRUCTION SET 08.01.08 12 ASI6 12.23.08 13 PERMIT RE-SUBMISSION 1.28.09 1/8" = 1'-0" 1/28/2009 8:39:10 AM C:\Drawings\revit\Northivew Church\2007-06019-Central-LOCAL.rvt P202 PIT LEVEL - NEW WORK New Worship Center TWN ATM 05-22-08 2007-06019 1/8" = 1'-0" 1 PIT LEVEL - NEW WORK GENERAL NOTES A ALL PIPING SHOWN IS LOCATED ABOVE SUSPENDED CEILINGS (AT THE UNDERSIDE OF STRUCTURE IN EXPOSED STRUCTURAL AREAS) UNLESS INDICATED OTHERWISE. B REFER TO DETAILS, DIAGRAMS AND SCHEDULES FOR PIPING AND PIPE SIZES NOT SHOWN. C PC SHALL COORDINATE INSTALLATION CAREFULLY WITH ALL OTHER TRADES. D ANNULAR SPACE OF PIPE, CONDUIT AND OTHER SIMILAR PENETRATIONS OF FIRE RATED ASSEMBLIES SHALL BE FIRESTOPPED. IN ADDITION, PENETRATIONS THRU 0-HOUR RATED FLOORS SHALL ALSO BE FIRESTOPPED TO RETARD PASSAGE OF FIRE AND SMOKE. REFER TO ARCHITECTURAL DRAWINGS FOR CONSTRUCTION, LAYOUT AND FIRE RATINGS OF FLOORS, WALLS, PARTITIONS AND OTHER BUILDING ELEMENTS. E FINISHED FLOOR ELEVATION: PIT LEVEL - 808.64' F PROVIDE INDIVIDUAL SHUT-OFF VALVES FOR ALL BASEMENT FIXTURES. NOTES 1 DOMESTIC WATER SERVICE. SEE DETAIL B ON SHEET P002 2 NOTE DELETED 3 PIT LEVEL DOMESTIC WATER HEATER. SEE DETAIL E ON SHEET P002 FOR EQUIPMENT, DEVICES AND PIPE SIZING. 4 PROVIDE OVERSIZED SLEEVE THRU WALL FOR GAS PIPING ENTERING BUILDING AND CAULK WEATHERTIGHT. SEE DETAIL B ON SHEET P001. 5 PROVIDE ISOLATION VALVE FOR SPRINKLER AT BOTTOM OF ELEVATOR PIT. 6 SPRINKLER FLOOR CONTROL VALVE BY FSC. SEE DETAIL A ON SHEET P001. 7 TO SPRINKLERS SERVING PIT LEVEL. COORDINATE LOCATIONS OF ALL SPRINKLER PIPING AND DEVICES CAREFULLY WITH ALL OTHER TRADES. 8 30 HP, 750 GPM VERTICAL INLINE FIRE PUMP PACKAGE. SEE DETAIL A ON SHEET P002. 9 RISER ISOLATION VALVE WITH SUPERVISORY SWITCH BY FSC. 10 PROVIDE VALVE, DIRT LEG, REGULATOR, UNION AND CONNECT TO HVAC BOILER PROVIDED BY HC. REGULATOR SHALL BE SIZED CAPABLE OF FLOWING 1,800 CFH WITH 2 PSI INLET PRESSURE AND 7" W.C. OUTLET PRESSURE. GAS REGULATORS TO VENT TO OUTSIDE. 11 PROVIDE STANDPIPE WITH 1.5" P-TRAP AND 6" OF 2" PIPING UNDER COUNTER FOR HVAC CONDENSATE PIPING. 12 2" PUMPED DISCHARGE FROM SUMP PUMP AT BOTTOM OF LIFT PIT TO RISE UP TIGHT TO WALL AND DISCHARGE OVER MOP BASIN. 13 PROVIDE TRAP PRIMER WITH DISTRIBUTION UNIT. DISCHAGE PIPING TO DROP TIGHT TO WALL TO UNDER FLOOR TO SERVE FLOOR DRAINS. 14 PROVIDE TRAP PRIMER WITH DISTRIBUTION UNIT ABOVE CEILING. DISCHARGE PIPIGN SHALL DROP CONCEALED IN WALL TO BELOW FLOOR AND SERVE TOIELT ROOM FLOOR DRAINS. 1 4" WATER SERVICE 6" FIRE SERVICE VR 1 CO 4" SANITARY INV. 805.14' VR 4 4" TO FDC 6" DS 4,615 SQ.FT. 6" ST 1 CO 8" ST 8,185 SQ.FT. INV. 806.97' 8" ST 1.5" DCW 1" DHW 1.DHWR5" DCW 0.75" 1.5" DCW UP 4" DOMESTIC WATER SERVICE UP 2.5" DCW 6" FIRE SERVICE UP 6" FROM FIRE PUMP TEST 6" DS 1 CO 8" STORM 7,945 SQ.FT. INV. 811.00' 1 CO 10" STORM 25,735 SQ.FT. INV. 806.64' INV. 815.00' FD2 VR 4" SS 8" DS 10" STORM VR UP TO FPTH CO CO CO CO 1.5" DCW 6 5 7 2" PUMPED DISCHARGE 2" PUMPED DISCHARGE FD2 G1 HD B1 CO FD2 FD2 D2 3" DS 400 SQ.FT. 3" STORM FD1 FD1 B1 C1 B2 A1 G1 A1 FD1 B2 A1 FD1 4" SS 2" PUMPED DISCHARGE UP TO MOP BASIN C2 C2 FD1 Date: Scale Drawn By Checked By Project Number ARCHITECTURE PLANNING INTERIOR DESIGN STRUCTURAL ENGINEERING 424 East Fourth Street Cincinnati, w w w . c h a r c h Ohio i t e c t s . 45202 c o m tel: 513/241/4474 fax: 513/241/0081 ISSUANCES COMPUTER FILE 1400 West Dorothy Lane Dayton, Ohio 45409-1310 Tel: (937) 224-0861 Fax: (937) 224-5777 3417 South Sherman Drive Beech Grove, IN 46107 Tel: (317) 780-1555 Fax: (317) 780-6525 750 North Orleans, Suite 400 Chicago, IL 60610 Tel: (312) 944-8230 Fax: (312) 944-8297 117 East Washington Street, Suite 200 Indianapolis, IN 46204 Tel: (317) 637-2222 Fax: (317) 637-2260 1137 West Taylor St. Suite 316 Chicago, IL 60607 Tel: (312) 224-8460 Fax: (312) 224-8961 1025 N.Watery Ln. Brigham City, UT 84302 TEL: (453) 723-5000 FAX: (453) 538-5506 6622 Kingspointe Parkway Orlando, FL 33819 Tel: (407) 816-9400 Fax: (407) 816-9300 10.18.07 No. Description Date 1 SCHEMATIC DESIGN 2 3 4 5 6 7 8 11 DESIGN DEVELOPMENT 01.18.08 CD 50% 03.14.08 PERMIT SET 04.25.08 ADDENDUM #2 05.16.08 ADDENDUM #3 05.22.08 ADDENDUM #5 06.04.08 PERMIT SET 06.10.08 CONSTRUCTION SET 08.01.08 12 ASI6 12.23.08 13 PERMIT RE-SUBMISSION 1.28.09 1/8" = 1'-0" 1/28/2009 8:38:46 AM C:\Drawings\revit\Northivew Church\2007-06019-Central-LOCAL.rvt P201 UNDERFLOOR PLAN New Worship Center TWN ATM 05-22-08 2007-06019 1/8" = 1'-0" 1 UNDERFLOOR PLAN GENERAL NOTES A ALL PIPING SHOWN IS LOCATED IN GRADE, BELOW FINISHED FLOOR UNLESS INDICATED OTHERWISE. B REFER TO DETAILS, DIAGRAMS AND SCHEDULES FOR PIPING AND PIPE SIZES NOT SHOWN. C PC SHALL COORDINATE INSTALLATION CAREFULLY WITH ALL OTHER TRADES. D FINSHED FLOOR ELEVATIONS: PIT LEVEL - 808.64' FIRST FLOOR - 817.64' NOTES 1 PIPING CONTINUED BY SITE UTILITY CONTRACTOR. 2 PIPING TO DROP IN THIS AREA. 3 COORDINATE CLOSELY WITH HC LOCATIONS AND ELEVATIONS OF BELOW FLOOR DUCTWORK AND PIPING. SANITARY AND DOMESTIC WATER PIPING TO BE LOCATED BELOW DUCTWORK. 4 PIPING CONTINUED ON SITE PLAN, SHEET P003. 5 LIFT PIT SUMP PUMP. SEE DETAIL D, SHEET P002. 6 SUMP PUMP DISCHARGE TO RISE UP TIGHT TO WALL NEXT TO MOP BASIN, ELBOW DOWN AND DISCHARGE INTO MOP BASIN. 7 ELEVATOR PIT SUMP PUMP. SEE DETAIL C, SHEET P002 WATER HEATER - 1ST LEVEL NOTES SCALE: NONE D P002 1 4 2 6 CO 2" MOTOR - 0.33 HP., 115V., 1-PHASE. 3 PD HEAVY DUTY STEEL COVER. TO RECEPTACLE PROVIDED BY E.C. SLEEVE PIPE THRU WALL AND PROVIDE EXTEND PUMPED DISCHARGE OVER MOP BASIN. INSTALL PIPING AS LOW AS POSSIBLE IN A MANNER TO NOT INTERFERE WITH LIFT EQUIPMENT CORD AND PLUG WITH UNIT. CONNECT BASIN - 18"x22" POLYETHYLENE WITH PERFORATED WATERTIGHT SEAL. UNIT - ZOELLER NO M57. LIFT PIT WALL. 5 4 2 3 PIT LEVEL SUBMERSIBLE SUMP PUMP PACKAGE CAPACITY - 34 GPM @ 10 FT. HD. 1 FS FPTH 6" 6" 6" F WS FLOOR DRAIN 0.75" 4" 1 4" WATER SERVICE. 2 STRAINER, WATTS #77F-D-FDA. PROVIDE BLOW-OFF PIPING WITH VALVE. RUN TO FLOOR DRAIN. 3 CHECK VALVE. 4 RP TYPE BACKFLOW PREVENTER, WATTS #009 SERIES 1 P 5 DRAIN VALVE 5 6 3" P 4" 2 4 3" 3 6 DOMESTIC WATER METER. SCALE: NONE 1 3 SUBMERSIBLE SUMP PUMP PACKAGE WITH OIL SENSOR HEAVY DUTY STEEL COVER. 2 3 MOTOR - 0.33 HP., 115V., 1-PHASE. CAPACITY - 30 GPM @ 10 FT. HD. TO RECEPTACLE PROVIDED BY EC. CORD AND PLUG WITH UNIT. CONNECT BASIN - 18" DIA x 30" DEEP POLYETHYLENE WITH PERFORATED UNIT - ZOELLER NO N57 OR EQUAL BY WEIL OR HYDR-O-MATIC 6 5 SLEEVE PIPE THRU WALL AND PROVIDE ELEVATOR PIT WALL. 2" TO MOP BASIN ON FIRST LEVEL. 4 1 6 4 WATERTIGHT SEAL. INSTALL PIPING IN A MANNER TO NOT INTERFERE WITH ELEVATOR CAR, RAILS, ETC. 2" 1.5" CO PD OIL SENSOR - ZOELLER NO 10-1527 PUMP SWITCH. 2 7 LOAD RELAY PROVIDED WITH OIL SENSOR. 7 5 5 6 B P002 A P002 C P002 5 1 FLOOR DRAIN 8 2 FLOOR DRAIN 8 THERMAL EXPANSION TANK 5 4" HIGH CONCRETE BASE BY P.C. AMTROL MODEL ST-5V 3 NOTE DELTED 6 VACUUM RELIEF VALVE. 7 ELECTRICAL CONNECTION BY E.C. RECOVERY: 27 GPH AT 90 DEGREES F. 1 ELECTRIC WATER HEATER 6 KW, 208V, 3 PH A.O. SMITH MODEL DSE-40 WITH GOLDENROD ELEMENTS, OR EQUAL 2 COMBINATION PRESSURE-TEMPERATURE STORAGE: 40 GALLONS RELIEF VALVE, AIR GAP DISCHARGE OVER TEMPERATURE RISE 4 DRAIN VALVE . EXTEND TO FLOOR DRAIN. 7 E SET THERMOSTAT AT 125 DEGREES. DCW DHWR DHW DCW 4 6 9 RECIRCULATION PUMP CAPACITY: 2 GPM @ 5 FT HD MOTOR: 0.4 AMP - 120 VOLT - 1 PHASE BASIS OF DESIGN: B&G BRONZE FOX NBF9U/LW WITH AQ-3/4 AQUASTAT. PROVIDE CORD AND PLUG AND PLUG INTO EC PROVIDED RECEPTACLE. 1.5" FROM WATER SERVICE 0.75" 1.5" 1" 0.75" 9 DCW DHW E P002 5 1 8 2 8 THERMAL EXPANSION TANK 5 4" HIGH CONCRETE BASE BY P.C. AMTROL MODEL ST-5V 6 VACUUM RELIEF VALVE. 7 ELECTRICAL CONNECTION BY E.C. 4 DRAIN VALVE . EXTEND TO MOP BASIN. 7 E 4 6 3 F P002 DCW DHW DHWR 2.5" 0.75" 1.25" DHW DCW DHWR DHWR DHWR FPTH FPTH 10 TRAP PRIMER WITH DISTRIBUTION UNIT. DISCHARGE PIPING TO DROP TIGHT TO WALL, UNDER FLOOR TO SERVE FLOOR DRAINS. 10 7 TRAP PRIMER WITH DISTRIBUTION UNIT. DISCHARGE PIPING TO DROP TIGHT TO WALL, UNDER FLOOR TO SERVE FLOOR DRAINS. 7 4" T T P WATER DEPARTMENT TO PROVIDE AND INSTALL WATER METER. PC TO PROVIDE WATER METER SPREAD. COORDINATE CLOSELY ALL RULES AND REGULATIONS WITH WATER DEPARTMENT. T T P MOP BASIN RECOVERY: 27 GPH AT 90 DEGREES F. 1 ELECTRIC WATER HEATER 6 KW, 208V, 3 PH A.O. SMITH MODEL DSE-40 WITH GOLDENROD ELEMENTS, OR EQUAL 2 COMBINATION PRESSURE-TEMPERATURE STORAGE: 40 GALLONS RELIEF VALVE, AIR GAP DISCHARGE OVER TEMPERATURE RISE SET THERMOSTAT AT 125 DEGREES. 3 RECIRCULATION PUMP CAPACITY: 2 GPM @ 5 FT HD MOTOR: 0.4 AMP - 120 VOLT - 1 PHASE BASIS OF DESIGN: B&G BRONZE FOX NBF9U/LW WITH AQ-3/4 AQUASTAT. PROVIDE CORD AND PLUG AND PLUG INTO EC PROVIDED RECEPTACLE. 9 FLOW CONTROLLER: PROVIDE UNIT SIZED FOR 1 GPM FLOW. 9 9 DCW DCW DHW DHW DCW Date: Scale Drawn By Checked By Project Number ARCHITECTURE PLANNING INTERIOR DESIGN STRUCTURAL ENGINEERING 424 East Fourth Street Cincinnati, w w w . c h a r c h Ohio i t e c t s . 45202 c o m tel: 513/241/4474 fax: 513/241/0081 ISSUANCES COMPUTER FILE 1400 West Dorothy Lane Dayton, Ohio 45409-1310 Tel: (937) 224-0861 Fax: (937) 224-5777 3417 South Sherman Drive Beech Grove, IN 46107 Tel: (317) 780-1555 Fax: (317) 780-6525 750 North Orleans, Suite 400 Chicago, IL 60610 Tel: (312) 944-8230 Fax: (312) 944-8297 117 East Washington Street, Suite 200 Indianapolis, IN 46204 Tel: (317) 637-2222 Fax: (317) 637-2260 1137 West Taylor St. Suite 316 Chicago, IL 60607 Tel: (312) 224-8460 Fax: (312) 224-8961 1025 N.Watery Ln. Brigham City, UT 84302 TEL: (453) 723-5000 FAX: (453) 538-5506 6622 Kingspointe Parkway Orlando, FL 33819 Tel: (407) 816-9400 Fax: (407) 816-9300 10.18.07 No. Description Date 1 SCHEMATIC DESIGN 2 3 4 5 6 7 8 11 DESIGN DEVELOPMENT 01.18.08 CD 50% 03.14.08 PERMIT SET 04.25.08 ADDENDUM #2 05.16.08 ADDENDUM #3 05.22.08 ADDENDUM #5 06.04.08 PERMIT SET 06.10.08 CONSTRUCTION SET 08.01.08 12 ASI6 12.23.08 13 PERMIT RE-SUBMISSION 1.28.09 1/28/2009 8:38:35 AM C:\Drawings\revit\Northivew Church\2007-06019-Central-LOCAL.rvt P002 DETAILS New Worship Center TWN ATM 05-22-08 2007-06019 8" GROUT GUARDRAIL POST 4'-0" DEEP MINIMUM FROM TOP OF RETAINING WALL, TYPICAL. FILL GAP BETWEEN POST AND FINISH TOP FINISH BLOCK OF WALL WITH COMPRESSIBLE FILLER AND SEALANT. RETAINING WALL EDGE 900145 E T T E L C O T T A B J . M . A R C H I T E C T . . NO STATE OF I N D I A N A D E R E T S I G E R Date: Scale Drawn By Checked By Project Number ARCHITECTURE PLANNING INTERIOR DESIGN STRUCTURAL ENGINEERING 424 East Fourth Street Cincinnati, Ohio 45202 w w w . c h a r c h i t e c t s . c o m tel: 513/241/4474 fax: 513/241/0081 ISSUANCES COMPUTER FILE 1400 West Dorothy Lane Dayton, Ohio 45409-1310 Tel: (937) 224-0861 Fax: (937) 224-5777 3417 South Sherman Drive Beech Grove, IN 46107 Tel: (317) 780-1555 Fax: (317) 780-6525 750 North Orleans, Suite 400 Chicago, IL 60610 Tel: (312) 944-8230 Fax: (312) 944-8297 117 East Washington Street, Suite 200 Indianapolis, IN 46204 Tel: (317) 637-2222 Fax: (317) 637-2260 1137 West Taylor St. Suite 316 Chicago, IL 60607 Tel: (312) 224-8460 Fax: (312) 224-8961 1025 N.Watery Ln. Brigham City, UT 84302 TEL: (453) 723-5000 FAX: (453) 538-5506 6622 Kingspointe Parkway Orlando, FL 33819 Tel: (407) 816-9400 Fax: (407) 816-9300 No. Description Date As indicated 2/9/2009 11:22:38 AM C:\!!!Bryan\Revit\NVCLC-bd.rvt A508 STAIR DETAILS NEW WORSHIP CENTER Checker Author 01-21-2009 535-3581 A508 3/4" = 1'-0" 4 ALTERNATING TREAD DEVICE 4 PERMIT SET 04.25.08 A508 1/2" = 1'-0" 1 PIT ROOF ACCESS LADDER 7 ADDENDUM #4 05.30.08 9 ADDENDUM # 6 06.10.08 10 PERMIT SET 06.10.08 11 CONSTRUCTION SET 08.01.08 A508 1/2" = 1'-0" 2 PIT LEVEL ENTRY GUARDRAIL ELEVATION 18 ASI 007 01.21.09 18 P9 1 A504 SECOND BALCONY LEVEL BELOW CATWALK LEVEL ALTERNATING TREAD DEVICE TO ROOF F4 F4 A3 1' - 11" 1' - 0" 7' - 0 1/16" 4' - 4" 1' - 2 3/4" 17 TREADS DN @ 11" = 14' - 8" A523 20 18 A523 19 1' - 11" 1' - 0" P M L C L4 L3 P12 P10 P9 1 A504 STAIR-3 S-23 F4 F4 A3 LEVEL 1 BELOW INTERMEDIATE LANDING ONE FIRST BALCONY LEVEL 15 TREADS UP @ 11" = 13' - 9" 1' - 0" 1' - 0" 1' - 11" 9' - 0" 14 TREADS UP @ 11" = 12' - 10" 15 TREADS DN @ 11" = 13' - 9" 4' - 6" 4" 4' - 6" A521 13 A12 P M L C L4 ND L3 P12 P10 M1 M2 P9 1 A504 STAIR-3 S-13 WOMENS' REST RM. 111 F4 F4 F6 A3 PIT LEVEL BELOW LEVEL 1 1' - 11" 1' - 0" 15 TREADS UP @ 11" = 13' - 9" 15 TREADS DN @ 11" = 13' - 9" 4' - 6" 4" M L C L4 ND P12 A302 4 P10 M1 M2 P9 1 A504 ? ? S03 4' - 4" PIT LEVEL 15 TREADS UP @ 11" = 13' - 9" C008 SEE C-SERIES DRWGS. FOR STAIR AND WALL 1' - 11" 1' - 0" 1' - 0" 1' - 0" 5' - 0" 9 TREADS @ 1'-8" = 15' - 0" 1' - 5 1/8" 1' - 0" 1' - 0 1/2" A508 2 AS-8 1 900145 E T T E L C O T T A B J . M . A R C H I T E C T . . NO STATE OF I N D I A N A D E R E T S I G E R Date: Scale Drawn By Checked By Project Number ARCHITECTURE PLANNING INTERIOR DESIGN STRUCTURAL ENGINEERING 424 East Fourth Street Cincinnati, Ohio 45202 w w w . c h a r c h i t e c t s . c o m tel: 513/241/4474 fax: 513/241/0081 ISSUANCES COMPUTER FILE 1400 West Dorothy Lane Dayton, Ohio 45409-1310 Tel: (937) 224-0861 Fax: (937) 224-5777 3417 South Sherman Drive Beech Grove, IN 46107 Tel: (317) 780-1555 Fax: (317) 780-6525 750 North Orleans, Suite 400 Chicago, IL 60610 Tel: (312) 944-8230 Fax: (312) 944-8297 117 East Washington Street, Suite 200 Indianapolis, IN 46204 Tel: (317) 637-2222 Fax: (317) 637-2260 1137 West Taylor St. Suite 316 Chicago, IL 60607 Tel: (312) 224-8460 Fax: (312) 224-8961 1025 N.Watery Ln. Brigham City, UT 84302 TEL: (453) 723-5000 FAX: (453) 538-5506 6622 Kingspointe Parkway Orlando, FL 33819 Tel: (407) 816-9400 Fax: (407) 816-9300 No. Description Date 1/4" = 1'-0" 2/9/2009 11:21:27 AM C:\!!!Bryan\Revit\NVCLC-bd.rvt A503 STAIR PLANS AND SECTIONS-STAIR 3 NEW WORSHIP CENTER Checker Author 01-21-2009 535-3581 A503 1/4" = 1'-0" 4 STAIR-3 SECOND BALCONY LEVEL A503 1/4" = 1'-0" 5 STAIR-3 CATWALK LEVEL A503 1/4" = 1'-0" 3 STAIR-3 FIRST BALCONY LEVEL A503 1/4" = 1'-0" 2 STAIR-3 LEVEL 1 A503 1/4" = 1'-0" 1 STAIR-3 PIT LEVEL 4 PERMIT SET 04.25.08 6 ADDENDUM #3 05.23.08 10 PERMIT SET 06.10.08 11 CONSTRUCTION SET 08.01.08 18 18 ASI 007 01.21.09 110A PLATFORM 119 SIDE PLATFORM 117 SIDE PLATFORM 120 PROJECTION ROOM STAIR-2 S-12 PIT LIFT Alternate A-1 CAPSTONE OFF. 121 A 2 A412 MAIN LEVEL - 21 ROWS - 1100 SEATS FIRST BALCONY - 8 ROWS - 530 SEATS SECOND BALCONY - 6 ROWS - 400 SEATS R 40' - 0" 1 A412 C101 1 5 H3 4 2.3 4 R 113' - 8 1/4" R 123' - 0" X9 X2 X3 X6 X7 X8 H2 4.6 4.6 H4 P 4.3 H5 4.8 M L L L4 S T ND U H1.5 1.5 9' - 9 1/4" MATCH LINE 2 3 S01C S101E S101F S11A S12A MATCH LINE 2 A413 2 A421 1 A421 8' - 3 3/4" 13' - 6 3/4" 11' - 8 3/8" R 123' - 0" 4' - 8 1/4" 31.01 R 105' - 0 1/4" 124.49 15' - 0" 3 A421 2 A423 1 A422 H3.2 CHAIR STORAGE/ CATERING 105 MENS' RESTROOM 108 ENTRANCE LOBBY 101 DIAPER CHANGE DIAPER CHANGE JAN. RM. 109 105 108 109 110A 111 X 2.0 3.8 3.8 H1 2.6 3.6 3.6 0.8 Y2 G Z 67' - 8 3/4" 48' - 2 3/4" L2 P12 R 112' - 9" P15 X10 X4 X5 CAPSTONE 114 A521 1 A521 2 A521 3 A302 2 3 A302 6 A302 4 A302 1 A302 7 X1 0.4 2.4 2.8 3.3 4.4 Y E F B Z2 Z3 Z1 Z4 P4 P5 P3 P2 P6 P7 P10 A502 2 A501 2 A511 4 STAIR-4 S-14 STAIR-3 S-13 N1 N2 N3 M1 M2 M3 N 1.3 2.1 W W3 W2 W1 P8 P9 SOUND BOOTH 104 CORR. C-101 116A 118C A532 2 A532 1 STAIR-5 S-15 2.2 4.2 N4 M4 A505 1 A503 2 4.1 4.1 P1 T4 T2 T3 T5 S1 S2 S3 S4 S5 S11B 1 A426 1 A423 3 A423 2 A427 118B CAPSTONE STO. 121 B 121B J J1 J2 LEVEL-1 103 115A 115B 3.1 R 49' - 9" 3 A424 2 A422 1 A424 4 A424 2 A424 2 A426 9 12 11 11 9 12 9 12 12 9 12 9 11 11 11 10 2 20 ROOF AREA SEE A251 21 17 22 TYP. 21 TYP. 21 11 21 TYP. 5 16 21 40' - 0" 13' - 2" 5' - 3 1/2" 3 1 12 4 1 21 TYP. 19 R 114' - 0 1/2" R 123' - 0" 16 20 20 10 3 A111 A111 4 3 A426 F6 F4 UP SLOPE 1:12 UP SLOPE 1:12 UP SLOPE 1:12 UP SLOPE 1:12 UP SLOPE 1:12 UP SLOPE 1:12 -3' - 0" -3' - 0" 0" 3' - 6" 0" 0" -3' - 0" 0" F4 F6 A3 F7 A3 A2 A3 A3 F3 F7 F3 F7 F3 F7 B2 F6 D1 F7 A3 A3 F6 A3 A2 D1 F6 F6 F6 A2 A1 F7 F7 F6 A3 F6 A3 A2 A3 A3 B2 F6 F4 F4 F2 B1 F2 F2 F4 F4 B1 B1 A1 F1 A2 F1 F1 A3 F1 F1 F1 F1 A2 B1 A3 A2 A2 A2 A2 D1 A1 A3 B1 A3 F3 DN SLOPE 1:12 DN SLOPE 1:12 DN SLOPE 1:12 DN SLOPE 1:12 DN SLOPE 1:12 DN SLOPE 1:12 17 17 82' - 5 13/16" 3' - 6" 8 15 A1 A3 F6 A2 A2 A2 TOILET TOILET F7 A3 A3 F6 9 A702 20 D1 F6 F6 F6 F6 6 Elevator Alternate A-2 LOBBY RENOVATION Alternate A-6 CAMERA PLATFORM 3 A427 817' - 7 5/8" 23 1' - 8 1/2" 8' - 0" 4" 28' - 10" 5' - 5" 4' - 9" 19' - 5" 18' - 9" 13 13 A533 8 1 A508 24 24 24 24 24 A611 11 A612 1 A612 2 A. A612 3 A612 8 16 A603 HOSE CABINET HOSE CABINET 5' - 0" 5' - 0" 5' - 0" 5' - 0" 5' - 3" DIAPER CHANGE DIAPER CHANGE SHELVES BENCH 110B WOMENS' REST RM. 110B 26 14 14 F4 F4 F3 A508 2 AS-8 1 5' - 8" 9' - 10" 4' - 0" ALIGN 11' - 0" 27 27 25 25 28 AS-10 1 1' - 5 1/16" 900145 E T T E L C O T T A B J . M . A R C H I T E C T . . NO STATE OF I N D I A N A D E R E T S I G E R Date: Scale Drawn By Checked By Project Number ARCHITECTURE PLANNING INTERIOR DESIGN STRUCTURAL ENGINEERING 424 East Fourth Street Cincinnati, Ohio 45202 w w w . c h a r c h i t e c t s . c o m tel: 513/241/4474 fax: 513/241/0081 ISSUANCES COMPUTER FILE 1400 West Dorothy Lane Dayton, Ohio 45409-1310 Tel: (937) 224-0861 Fax: (937) 224-5777 3417 South Sherman Drive Beech Grove, IN 46107 Tel: (317) 780-1555 Fax: (317) 780-6525 750 North Orleans, Suite 400 Chicago, IL 60610 Tel: (312) 944-8230 Fax: (312) 944-8297 117 East Washington Street, Suite 200 Indianapolis, IN 46204 Tel: (317) 637-2222 Fax: (317) 637-2260 1137 West Taylor St. Suite 316 Chicago, IL 60607 Tel: (312) 224-8460 Fax: (312) 224-8961 1025 N.Watery Ln. Brigham City, UT 84302 TEL: (453) 723-5000 FAX: (453) 538-5506 6622 Kingspointe Parkway Orlando, FL 33819 Tel: (407) 816-9400 Fax: (407) 816-9300 No. Description Date 1/8" = 1'-0" 2/9/2009 11:20:36 AM C:\!!!Bryan\Revit\NVCLC-bd.rvt A211-A FIRST FLOOR PLAN NEW WORSHIP CENTER Checker Author 01-21-2009 535-3581 1 SCHEMATIC DESIGN 10.18.07 2 DESIGN DEVELOPMENT 01.18.08 3 CD 50% 03.14.08 4 PERMIT SET 04.25.08 GENERAL NOTES KEYNOTES A. ALL DIMENSIONS ARE TO FINISH FACE OF CONSTRUCTION UNLESS NOTED OTHERWISE. B. SEE PARTITION SCHEDULE ON SHEET A702 FOR GRAPHIC AND NARRATIVE DESCRIPTION OF THE PARTITION TAGGED AND KEYNOTED ON THESE PLAN DRAWINGS. C. SEE SHEET A000 FOR ADDITIONAL GENERAL NOTES AND ABBREVIATED NOTES WHICH MAY APPEAR ON ALL CONSTRUCTION PLANS AND DRAWINGS. D. PARTITION TYPES INDICATED ARE CONTINUOUS TO A CORNER OR AN INTERSECTING PARTITION, UNLESS INDICATED OTHERWISE. WHERE PARTITIONS OF DIFFERENT THICKNESSES MEET, MAINTAIN A FLUSH SURFACE ON THE SIDE WHERE FACES ARE STRAIGHT AND CONTINUOUS, UNLESS NOTED OTHERWISE. E. METAL STUD GAUGES SCHEDULED ARE THE MINIMUM REQUIRED, AND MAY BE INCREASED BY SPECIFICATIONS TO ACCOMMODATE LOADS, FINISHES, OR UNBRACED CEILING HEIGHT LIMITS. DO NOT CONSIDER CEILING SYSTEM(S) AS A PARTITION BRACING ELEMENT. F. EDGES OF GYPSUM BOARD LEFT EXPOSED TO VIEW, OR ABUTTING DISSIMILAR MATERIAL, IS TO BE FINISHED WITH METAL "J" BEAD TRIM AND COMPOUND UNLESS NOTED OTHERWISE. G. PARTITION SCHEDULE IS BASED ON THE USE OF GYPSUM BOARD, BUT FACING BOARD MAY VARY, DEPENDENT ON FINAL FINISH SCHEDULED FOR THAT PARTITION: USE MOISTURE AND MOLD RESISTANT BOARD WHERE SINKS OR CERAMIC TILE ARE SCHEDULED. H. ALL DOOR OPENINGS SHALL BE 6" FROM A PERPENDICULAR PARTITION TO OUTSIDE FACE OF FRAME, UNLESS NOTED OR DETAILED OTHERWISE. PLATFORM. CONSTRUCTION: 1/2" x 4'-0" x 8'-0" PAINTED PLYRON FINISH FLOORING (STAGGERED JOINTS), SCREW ATTACHED OVER 1" T&G PLYWOOD OR OSB SUBSTRATE, GLUE ADHERE TO POURED CONCRETE DECK. FACE OF PLATFORM (36” ABOVE SEATING FLOOR) REF. # 9/A7.02 FOR SECTION DETAIL OF FACE OF STAGE. LIFT. ALTERNATE A-1. BASE BID WORK EXCLUDES THE MECHANICAL LIFT. THE LIFT PLAFORM AREA WILL BE FILLED WITH A PIT PLATFORM INFILL SYSTEM. SEE SHEET TP1.1 FOR SCOPE OF BASE BID WORK. ALTERNATE A-1 BID TO INCLUDE THE MECHANICAL LIFT IN LIEU OF THE INFILL SYSTEM. SEE SHEET TP1.0 FOR THE SCOPE OF THIS WORK. REAR PROJECTION SCREEN/CYC. SLAB ON GRADE CONCRETE. ACID STAIN BLACK. CAMERA PLATFORM. 1’ HIGH WOOD PLATFORM WITH INTEGRAL STEP. FULLY CARPETED. AISLE WAY, CARPETED. EDGE OF AISLEWAY INDICATED WITH SOLID LINE. THEATER SEATING SHALL NOT ENCROACH UPON THIS BOUNDARY LINE. AISLEWAY EGRESS LIGHTING PROVIDED BY DOWNLIGHTING INTEGRAL WITH THEATER SEATS. NOT USED FIXED SEATING AREA FLOORING FINISH: ACID STAINED CONCRETE. REFER TO FINISH LEGEND AND SPECIFICATIONS. REAR AND FRONT CROSSAISLES. CARPETED. EDGE OF CARPETING EXTENDED INTO SEATING ZONE BY 2’-0". PROVIDE RUBBER TRANSITION STRIP, COLOR AS SELECTED BY ARCHITECT. FIXED AUDITORIUM SEATING. SEATING MANUFACTURER TO PROVIDE LAYOUT WITH AVERAGE CHAIR WIDTH OF 22” AND ROW SPACING OF 36”. LAYOUT TO ACCOUNT FOR GOAL STATED ON DRAWINGS FOR EACH LEVEL FOR A TOTAL PROJECTED WORSHIP CENTER SEAT COUNT OF 2000 MIN. SEATING LAYOUT SHOWN IS FOR INFORMATIONAL AND CONCEPTUAL PURPOSES ONLY AND IS NOT INTENDED AS THE FINAL LAYOUT. SEATING SUPPLIER AND INSTALLERS SHALL COORDINATE EARLY IN THE PROJECT WITH THE MECHANICAL CONTRACTOR TO LOCATE THE UNDERFLOOR AIR DISTRIBUTION DEVICES. HANDRAILING. 1 1/2:” DIA. WOOD ON WALL BRACKETS. INSTALLED HEIGHT 36”. MAIN CURTAIN, SEE THEATER DRAWINGS TR1.0. OPENING IN PLATFORM TO PIT LEVEL BELOW. PROVIDE SAFETY NETTING FOR FALL PROTECTION TO FILL OPENING. NETTING TO BE INSTALLED IN MULTIPLE (4 TO 6) SECTIONS WITH MEANS FOR ATTACHMENT AT FULL PERIMETER OF OPENING. SUPPLIER TO ENGINEER NETTING TO MEET LOADING REQUIREMENTS. ANY STAIR DEVICES SHOWN ON ANY DRAWINGS IN THIS AREA ARE NOT TO BE INCLUDED IN THIS PROJECT AND WILL BE PORTABLE DEVICES PROVIDED BY THE OWNER. UTILITY SINK, SEE PLUMBING DRAWINGS. FLOOR SINKS IN JANITOR CLOSETS TO RECEIVE CERAMIC TILE ON TWO WALLS WITH S.S. MOP HOLDER. PROJECTOR SHELVING FOR REAR PROJECTORS. SEE STRUCTURAL DWGS. NOT USED. SIDE STAGE MONITOR POSITION. REFERENCE SHEET AV253 FOR ADDITIONAL INFORMATION. SYMBOL INDICATES ADA WHEELCHAIR ACCESSIBLE SEATING, TYP. FACILITY WILL COMPLY WITH 1% DESIGNATED SEATING TO COMPLY WITH IBC 1108.2.2. 21 SPACES FOR PROJECTED COUNT OF 2,030. STRUCTURAL TUBE STEEL MEMBERS, TYP. SEE STRUCTURAL DRAWINGS. STRUCTURAL MEMBERS (COLUMNS, BEAMS, TRUSSES AND BRACING) SHOWN EXPOSED TO VIEW ON PLANS TO BE PAINTED, FULL HEIGHT UNLESS OTHERWISE INDICATED. ALL WALLS, CEILINGS, STAIRS, STRUCTURE, CONDUITS, AND HVAC DEVICES IN THIS AREA TO BE PAINTED BLACK. FLOORS TO BE SEALED CONCRETE. SOUND MIXING BOOTH WITH LOW GYPSUM BOARD PARTITIONS. REF. SECTION 3/A5.10 AND AV253 FOR ADDITIONAL INFORMATION. AREA TO BE FULLY CARPETED. FINISH FLOOR ELEVATION = 2'-4" BELOW MAIN LEVEL. PROVIDE 1:12 RAMPED CONCRETE FLOOR TRANSITION AT BOOTH ENTRANCE FROM AISLE TO WEST OF BOOTH. 3/4" PAINTED PLYWOOD OVER GYB. BD., 4'-0" HIGH FROM FINISH FLOOR. TRAFFIC BOLLARDS, REFERENCE 15/A6.03 FOR DETAIL. FUTURE PODIUM OPENING. SEGMENTED BUMPER RAIL. 42" HIGH GUARDRAIL WITH 1-1/2" DIA PAINTED STEEL TUBE. MAXIMUM 21" BETWEEN HORIZONTAL AND VERTICAL TUBES. 1-1/2" DIA PAINTED STEEL TUBE HANDRAIL AT STAIR WITH 1'-0" EXTENSION AT TOP AND BOTTOM OF STAIR. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 ADD STAGE LIFT. STAGE PLATFORM TO FILL IN AREA OF THE STAGE LIFT IN BASE BID. ADD ELEVATOR SYSTEM (CAB, MACHINE, CONTROLS, RAILS, PISTON). HOISTWAY SHAFT, PIT, LOCKED HOISTWAY DOORS, CONDUITS AND PATHWAYS AND ALL ROUGH-IN AND BACK-BOXES TO INSTALL ELEVATOR AND HALL STATIONS AT A LATER DATE TO BE BASE BID. DEDUCT ALL WORK IN EXISTING WORSHIP SPACE BELOW MATCH LINE EXCEPT STAIR S-5 AND ANY CUTTING AND PATCHING REQUIRED FOR NEW ADDITION. Alternate A-2 Alternate A-6 Alternate A-1 5 ADDENDUM #2 05.16.08 23 6 ADDENDUM #3 05.23.08 A211-A 1/8" = 1'-0" 1 LEVEL-1 MAIN LEVEL-A 24 8 ADDENDUM #5 06.04.08 10 PERMIT SET 06.10.08 11 CONSTRUCTION SET 08.01.08 19 19 19 19 19 19 19 19 19 19 19 19 19 25 26 19 19 19 27 19 19 19 19 19 19 19 19 19 ASI 008 02.02.09 19 28 18 J J1 J2 7 (12) 5 (98) STAIR-1 S-01 CONF. RM. 003 STO. RM. 001 SERVER ROOM 002 WOMEN'S C.R. 019 BLUE SKY RM. 005 OFFICE 006 OFFICE 007 OFFICE 008 OFFICE 009 OFFICE 010 OFFICE 011 WORK STATIONS 015 WORK RM. 016 WAIT/LOBBY 014 RECE. 013 GREEN ROOM 021 VIDEO CONTROL 022 MECH. ROOM 020 FIRE PUMP ROOM 034 TRAP ROOM 033 AUDIO CONTROL 026 VIDEO EDIT 027 RECORDING STUDIO 029 DRUM 031 VOICE 030 VESTIBULE C008 OFFICE 004 CORR. C-001 C.R. WAITING AREA 017 MEN'S C.R. 018 GREEN RM. ENTRY 021A CORR. C-007 CORR. C-005 VEST. 025 CORR. C-009 ? ? 3.1 A. NUMBER OF CALCULATED OCCUPANTS PATH OF EGRESS RECESSED FEC HANDICAPPED ENTRY 1 HOUR RATED WALL 2 HOUR RATED WALL APPLIED FIREPROOFING MATERIAL ON STEEL STRUCTURE IN SHADED AREA UL#X772 (1 HR. FIRE RATING FOR WIDE FLANGE COLUMNS) UL#X771 (1 HR. FIRE RATING FOR TUBE COLUMNS) UL#N782 (1 HR. FIRE RATING FOR BEAMS & MISC. STEEL) 100 BD C2 CB 1 3 5 H3 2.3 4 X9 X2 X3 X6 X7 X8 H2 4.6 H4 P 4.3 H5 4.8 M L C L4 Q S ND U H1.5 1.5 H3.2 X 2.0 3.8 H1 0.8 2.6 3.6 Y2 G Z L2 L3 P12 P15 X10 X4 X5 X1 0.4 2.4 2.8 3.3 4.4 Y E F B Z2 Z3 Z1 Z4 P4 P5 P3 P2 P6 P7 P10 N1 N2 N3 M1 M2 M3 N 1.3 2.1 W W3 W2 W1 P8 P9 2.2 4.2 N4 4.1 P1 T4 T1 T2 T3 T5 S1 S2 S3 S4 S5 WORKSHOP 116 STORAGE 115 SIDE PLATFORM 117 DELIVERY 118 STAIR-1 S-11 CHAIR STORAGE/ CATERING 105 VEST. 107 CORR. C-101 SOUND BOOTH 104 VESTIBULE 102 VEST. 112 VEST. 113 VESTIBULE 106 J J1 J2 1 (1100) 6 (2) 4 (97) 5 (2) 4 (162) 2 (325) 2 (525) 3 (96) 2 (346) 6 (2) 5 (3) 2 (105) 7 (1) 6 (3) 7 (7) 4 (284) 7 (1) TWO HOUR SEPARATION BETWEEN EXISTING ASSEMBLY USE AND NEW A-3 ASSEMBLY USE PLATFORM 119 LEVEL-1 103 3.1 A. 2/9/2009 11:18:01 AM 900145 E T T E L C O T T A B J . M . A R C H I T E C T . . NO STATE OF I N D I A N A D E R E T S I G E R Date: Scale Drawn By Checked By Project Number ARCHITECTURE PLANNING INTERIOR DESIGN STRUCTURAL ENGINEERING 424 East Fourth Street Cincinnati, Ohio 45202 w w w . c h a r c h i t e c t s . c o m tel: 513/241/4474 fax: 513/241/0081 ISSUANCES COMPUTER FILE 1400 West Dorothy Lane Dayton, Ohio 45409-1310 Tel: (937) 224-0861 Fax: (937) 224-5777 3417 South Sherman Drive Beech Grove, IN 46107 Tel: (317) 780-1555 Fax: (317) 780-6525 750 North Orleans, Suite 400 Chicago, IL 60610 Tel: (312) 944-8230 Fax: (312) 944-8297 117 East Washington Street, Suite 200 Indianapolis, IN 46204 Tel: (317) 637-2222 Fax: (317) 637-2260 1137 West Taylor St. Suite 316 Chicago, IL 60607 Tel: (312) 224-8460 Fax: (312) 224-8961 1025 N.Watery Ln. Brigham City, UT 84302 TEL: (453) 723-5000 FAX: (453) 538-5506 6622 Kingspointe Parkway Orlando, FL 33819 Tel: (407) 816-9400 Fax: (407) 816-9300 No. Description Date As indicated 2/9/2009 11:18:13 AM C:\!!!Bryan\Revit\NVCLC-bd.rvt A001 LIFE SAFETY PIT LEVEL AND MAIN LEVEL NEW WORSHIP CENTER Checker Author 01-21-2009 535-3581 A. APPLICABLE CODES 1. INDIANA BUILDING CODE - 2003 (REFERENCES IBC 2000) B. BUILDING CLASSIFICATIONS 1. USE GROUP: (IBC 303.1) - ASSEMBLY GROUP, A-3 2. SEPARATION OF OCCUPANCIES: (IBC T302.3.3) - 2 HOURS BETWEEN NEW A-3, ASSEMBLY AND EXISTING A-3, ASSEMBLY 3. CONSTRUCTION CLASSIFICATION: (IBC 603) - 2B, NON-COMBUSTIBLE, UNPROTECTED C. HEIGHT AND AREA LIMITATIONS 1. ALLOWABLE HEIGHT: (IBC T503) - 2 STORIES/55'-0" 2. HEIGHT MODIFICATIONS: (IBC 504.2) - +2 STORIES/55'-0" +1 STORY/20'-0" (WITH AUTOMATIC SPRINKLERS) +3 STORIES/75'-0" 3. ALLOWABLE AREA: (IBC T503) - 9,500 GSF/STORY 4. AREA MODIFICATIONS (IBC 506) - +9,500 GSF ALLOWABLE AREA +23,000 GSF (WITH AUTOMATIC SPRINKLERS) +46,000 GSF/STORY 5. a. ACTUAL HEIGHT: 2 STORIES/65'-4" b. ACTUAL GSF: 25,600 SF MAIN LEVEL/ 13,200 SF PIT LEVEL D. FIRE RESISTANT RATINGS 1. STRUCTURAL FRAMING INCLUDING COLUMNS, GIRDERS, TRUSSES SUPPORTING MORE THAN 1 FLOOR - 0 HR. (T601) SUPPORTING ROOF ONLY - 0 HR. (T601) 2. EXTERIOR WALLS (LOADBEARING) - 0 HR. (T601) (NONLOADBEARING) - 0 HR. (T601) 3. INTERIOR WALLS (LOADBEARING) - 0 HR. (T601) (NONLOADBEARING) - 0 HR. (T601) 4. FLOORS - 0 HR. (T601) 5. ROOF - 0 HR. (T601) 6. SHAFTS/ELEVATOR HOISTWAY - 1 HR.< 4 STORIES (707.4) (INCLUDING STRUCTURE) UL NUMBERS FOR APPLIED FIREPROOFING UL#X772 (1 HR. FIRE RATING FOR WIDE FLANGE COLUMNS) UL#X771 (1 HR. FIRE RATING FOR TUBE COLUMNS) UL#N782 (1 HR. FIRE RATING FOR BEAMS & MISC. STEEL) - CLOSE OFF BOTTOM OF SHAFTS TO MAINTAIN SAME RATING AS WALLS AND SUPPORTING STRUCTURE 7. CORRIDORS - 0 HR. (T1004.3.2.1) 8. EXIT PASSAGEWAY - 1 HR. (1005.3.3.2) 9. PERIMETER FIRE SEPARATION - 10" GAP MAXIMUM, UL #CW-D-2001 - 2.5" GAP MAXIMUM, UL #CW-S-1001 CALCULATION OF OCCUPANT LOAD DETERMINED PER OBC 1003.2.2.2 (THE NUMBER IN "()" IDENTIFIES THE NUMBER OF OCCUPANTS): ACTUAL FIXED SEATING LAYOUT ROOM AREA (NET S.F.) DIVIDED BY 5 (ASSEMBLY STANDING) ROOM AREA (NET S.F.) DIVIDED BY 7 (ASSEMBLY CHAIRS) ROOM AREA (NET S.F.) DIVIDED BY 15 (ASSEMBLY WITH TABLES AND CHAIRS AND STAGES/PLATFORM AREAS) ROOM AREA (GROSS S.F.) DIVIDED BY 100 (BUSINESS AREA) ROOM AREA (GROSS S.F.) DIVIDED BY 200 (KITCHEN) ROOM AREA (GROSS S.F.) DIVIDED BY 300 (STORAGE AREA/MECHANICAL AREA) A001 1/16" = 1'-0" 2 LIFE SAFETY LEVEL-0 PIT LEVEL 1 2 3 4 5 6 7 E. MEANS OF EGRESS 1. OCCUPANT LOAD: PIT LEVEL - 110 OCCUPANTS (IBC T1003.2.2.2) MAIN LEVEL - 3,061 OCCUPANTS (IBC T1003.2.2.2) FIRST BALCONY - 543 OCCUPANTS (IBC T1003.2.2.2) SECOND BALCONY - 400 OCCUPANTS (IBC T1003.2.2.2) TOTAL - 4,114 OCCUPANTS 2. CAPACITY OF COMPONENTS: a. NUMBER OF PEOPLE PER STAIR: 543 PEOPLE (FIRST BALCONY OCCUPANTS)/ 3 STAIRS = 181 PEOPLE / STAIR b. REQUIRED WIDTH OF STAIR (44" MIN REQUIRED - IBC 1003.3.3.1): .2" x 181 (FIRST BALCONY OCCUPANTS) = 37" c. REQUIRED WIDTH OF DOORS (32" MIN REQUIRED - IBC 1003.3.1.1): .15" x 1,396 (NEW WORSHIP CENTER OCCUPANTS) = 210" (16 DOORS X 36" WIDE = 576" OUT OF WORSHIP CENTER) .15" x 1,665 (EXISTING SANCTUARY OCCUPANTS) = 250" .15" x 4,114 (TOTAL MAIN LEVEL OCCUPANTS) = 618" (19 DOORS X 36" WIDE = 684" OUT OF BUILDING) 3. LENGTH OF EXIT ACCESS TRAVEL: 250 L.F.. (IBC T1004.2.4) - FULLY SPRINKLERED 4. COMMON PATH OF TRAVEL: 75'-0" MAX. (IBC 1004.2.5) - FULLY SPRINKLERED 5. DEAD END LENGTH: 20'-0" MAX. (IBC 1004.3.2.3) - FULLY SPRINKLERED F. PLUMBING FIXTURES REQUIREMENTS (IBC T2902.1) 1. OCCUPANT LOAD (NEW WORSHIP CENTER & ALL EXISTING LEVELS): 2,909 MALE OCCUPANTS 2,909 FEMALE OCCUPANTS 2. WATER CLOSETS: 2,909/150 = 20 WATER CLOSETS, MALE REQUIRED (36 WATER CLOSETS PROVIDED) 2,909/75 = 39 WATER CLOSETS, FEMALE REQUIRED (39 WATER CLOSETS PROVIDED) 3. LAVATORIES: 2,909/200 = 15 LAVATORIES, MALE REQUIRED (20 LAVATORIES PROVIDED) 2,909/200 = 15 LAVATORIES, FEMALE REQUIRED (24 LAVATORIES PROVIDED) 4. DRINKING FOUNTAINS: 5,818/1000 = 6 DRINKING FOUNTAINS (6 DRINKING FOUNTAINS PROVIDED) 4 PERMIT SET 04.25.08 A001 1/16" = 1'-0" 1 LIFE SAFETY LEVEL-1 MAIN LEVEL 5 ADDENDUM #2 05.16.08 6 ADDENDUM #3 05.23.08 10 PERMIT SET 06.10.08 11 CONSTRUCTION SET 08.01.08 16 ASI #005 - VOIDED 12.03.08 19 ASI 008 02.02.09