HomeMy WebLinkAboutG110SCHEMATIC SECTION
LOWER PARKING
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
Roof Roof
G110
Roof
Roof
TOTAL
1.1 TRADITIONAL
1.1 DELUXE
20
TOTAL
1.1 DEN
2.2 TRADITIONAL
2.2 GRAND
2.2 DELUXE
SQ FT
30
34
24
21
9
SQ FT
20
12
2
44
UNIT TYPE
UNIT TYPE
TOTAL
PARKING
QUANITY
QUANITY
SURFACE
INDEPENDENT LIVING
746
851
1191
1351
1461
10
550
625
632
800
171
QUANITY
120
251
371
1463
1041
33
1625
UNDERGROUND
TOTAL
SQ FT
12
1
1
18
UNIT TYPE QUANITY
362
433
439
TOTAL
SQ FT
29
1
30
UNIT TYPE QUANITY
ASSISTED LIVING
MEMORY CARE
SKILLED NURSING
ONE BEDROOM
TWO BEDROOM
2.2 DELUXE ALT. w/DEN
2.2 CLASSIC w/DEN
0
ONE BEDROOM
TWO BEDROOM
TWO BEDROOM
TWO BEDROOM
TWO BEDROOM
TWO BEDROOM
2.2 DELUXE
1.1 TRADITIONAL
1.1 TRADITIONAL
1.1 STANDARD
UNIT ’A’
UNIT ’B’ 370 1
UNIT ’C’ 401 1
UNIT ’D’ 402 1
UNIT ’E’ 405 1
UNIT ’F’
UNIT ’G’
2 HOUR FIRE WALL
2 HOUR OCCUPANCY SEPARATION WALL
2 HOUR FIRE WALL
2 HOUR OCCUPANCY
SEPARATION WALL
STANDARD PRIVATE 305
ISOLATION 305
WING B
WING C
WING E
WING H
WING G
WING J
WING K
SKILLED NURSING
I.L. COMMONS
A.L. COMMONS
ASSISTED LIVING/
MEMORY CARE
INDEPENDENT LIVING
PARKING BELOW
COURTYARD
MAIN ENTRY
INDICATES HORIZONTAL
2 HOUR OCCUPANCY
SEPARATION AT
FIRST FLOOR CEILING
INDICATES HORIZONTAL
2 HOUR OCCUPANCY
SEPARATION AT
FIRST FLOOR CEILING
CODE COMPLIANCE & PLAN LAYOUT INFORMATION
2 HOUR FIRE WALL
2 HOUR OCCUPANCY
SEPARATION WALL
2 HOUR FIRE WALL
WING D
WING A
ABOVE
SQUARE FOOTAGES ARE BASED ON THE ABOVE AREAS
FIRST FLOOR
WINGS A and B
WINGS C and D WINGS C and D
WINGS A and B
SKILLED
NURSING
FACILITY
MEMORY
CARE
AL COMMONS
WING E IL COMMONS
WING H
WING F
WING G
WING J
WING K
WING F
ABOVE
SECOND AND THIRD FLOORS
Independent R-2
Independent R-2
Independent R-2
Parking S-2
Independent R-2
Independent R-2
Commons A-3
Assisted I-1
Assisted I-1
Memory Care I-2 Skilled Nursing I-2
2 Hour Horizontal
Occupancy Separation
1 HOUR SMOKE WALL -
EXTEND UP TIGHT TO
HIGHEST ROOF SHEATHING
1 HOUR SMOKE WALL -
EXTEND UP TIGHT TO
HIGHEST ROOF SHEATHING
1 HOUR SMOKE WALL -
EXTEND UP TIGHT TO
RATED SECOND FLOOR
ASSEMBLY
1 HOUR SMOKE WALL -
EXTEND UP TIGHT TO RATED
SECOND FLOOR ASSEMBLY
Commons : Accessory Occupancies
Per Section 508.3.1
AQUATIC CENTER
INDEPENDENT LIVING
21 Unit Alternate
Alternate
2-6 2-6
D
1414 UNDERWOOD AVE.
WAUWATOSA, WI 53213
414.431.3131
414.431.0531 FAX
TEL
WWW.AGARCH.COM
Architecture
Engineering
Planning
REVISIONS
DRN
THIS DRAWING, ITS DESIGN CONCEPT AND ITS DETAIL ARE
THE SOLE PROPERTY OF AG ARCHITECTURE, INC. AND SHALL
NOT BE COPIED IN ANY FORM OR MANNER WITHOUT
WRITTEN AUTHORIZATION OF ITS DESIGNER/CREATOR
SHEET NO.
DATE
PROJECT
DRAWN BY
Continuing Care Retirement
Carmel Indiana
071101
The Barrington of Carmel
NOT FOR
CONSTRUCTION
01 OCT 2008
2-6 2-6
3-0