Loading...
HomeMy WebLinkAbout09040009-10 Glick Indoor Self Storage Large Plan Pg 1810 PWPL w W Q W w a w EM Q w San MH T -C.- 810.24 N Inv -804.4 E Inv- 803.8 GA W Inv -803.9 8 "VCP 10 w w Ui w a W w W P Ar7.749 ice WAT R MAIN c v0 cs z_ w Q O z H- X WV W San MH S I- TPed. /0Nh4 9 Yard Light ign Yard Light Inv 809.60 eoI End Section Sigma li 11: 9 No aerial fi nes .PWPPv Stone Wall w w AUX. 6" FIRE LINE FD CONNECTION FIRE HYDRANT AND VALVE FIRE LINE (SIZED BY OTHERS) DOMESTIC LINE Light GIB 8 Light COOL CREEK BOULEVARD „-2' Rolled Curb with Gutter Bollard (tYP.) o 0 "NORTHSIDE TRAILER" One Story Brick Metal Sided Building on Slab 8 HVACt Mini -Barn on skids Xfm r PWP Block Wall Dumpster Pad X "Northern Parcel" A part of LANCASTER REALTY, LLC Inst. No. 2005 -41017 2.398 acres, E(A)- 7 7 E(A) z 1° L EM Ugh �HVAC Fuel Tank E(A) PPWPL o N 6 17 77 m outh re n Parcel" Apart of LANCASTER REALTY, LLC Inst. No. 2005 -41017 2.311 acres, 6 N 8" \I°' Timber Retaining Wail --Approx. Top of Bank Light 5 Wooded Area 805 7Flowline, Ditch 5 Approximate Edge of Woods (Drip Line) fj Wooded Area 4 Wooded Area Wooded Area Approximate ,Edge of Woods (Drip Line) San MH T. C.-804.17 N/S Inv -800.7 W Inv-801.3 15 0' 5' Water Sewer Easement per Deed Book 234, Page 179 C/L :5 Water Sewer Easement as referenced in inst. No. 2005 -41017 and as shown on prior surveys C/L 15' W er Sewer Easement as describe in Deed Book 234, Page 179 3 TAO SUB ITTAL MINIMUM COVER FOR PIPE CROSSINGS WITHIN CITY RIGHT —OF —WAY For installation of Storm Mains, Water Mains, Sanitary Mains, Water Service Laterals, Sanitary Service Laterals under City streets, regardless of jurisdiction of the utility, the minimum cover from the top of the installed pavement to the top of the installed pipe shall be the pavement section thickness (all bituminous and aggregate material above the subgrade) plus 1 —0 but under no circumstances shall the cover along any part of the pipe from the final pavement elevation to the top of the pipe be less than 2.5 —feet. If the standard practice of the utility that has jurisdiction over the installation has a more stringent cover requirement, the more stringent requirement shall govern. Cover heights for reinforced concrete pipe storm sewer that are less than those required will be evaluated on a case by case condition and approved only with written permission by the city engineer. WATER AND SEWER UNDER PAVEMENT, SIDEWALK, PAVED AREAS AND WITHIN RIGHT —OF —WAY BEDDING, HAUNCHING, INITIAL BACKFILL Bedding, Haunching and initial backfill requirements and compaction for water mains, water service laterals, sanitary mains and sanitary service laterals shall be in accordance with the standard practice of the utility that has jurisdiction over the installation. FINAL BACKFILL Final backfill for water mains, water service laterals, sanitary mains and sanitary service laterals under and within 5 —feet of pavement or sidewalk or other paved areas and for all installations within City right —of —way shall be B— Borrow for Structure Backfill meeting the material requirements of the INDOT. The material shall be approved by the City of Carmel Department of Engineering at time of installation. Final backfill shall be compacted in 6 —inch maximum lifts to not less than 95% Standard Proctor Density for the entire depth of the material placed. The backfill for the top 6— inches of the excavation below the start of the aggregate sub —base of the pavement shall be No. 53 Stone meeting the material requirement of the INDOT and shall be compacted to not less than 95% Standard Proctor Density. If the standard practice of the utility that has jurisdiction over the installation has a more stringent backfill requirement, the more stringent requirement shall govern. 0 O 15 LEGEND SCALE: 1" 30' 2 30 EXIST. FIRE HYDRANT EXIST. WATER METER EXIST. WATER VALVE EXIST. YARD SPIGOT EXIST. MONITOR WELL EXIST. GAS METER EXIST. GAS VALVE EXIST. STORM INLET EXIST. ELECTRIC METER EXIST. POWER POLE EXIST. POWER POLE W /LIGHT EXIST. POWER POLE W /TRANSFORMER EXIST. LIGHT POLE EXIST. GUY ANCHOR EXIST. TELEPHONE PEDESTAL EXIST. MANHOLE EXIST. SANITARY SEWER LINE EXIST. STORM SEWER LINE RIGHT -OF -WAY LINE SWALE PROPOSED SANITARY SEWER LINE PROPOSED STORM SEWER LINE PROPOSED MANHOLE PROPOSED FIRE HYDRANT PROPOSED BLOWOFF BLUE HYDRANT PAVEMENT MARKER PROPOSED WATER VALVE THERE SHALL BE NO FRAv1ES, CASTINGS, OR VALVE BOX EXTENSIONS IN THE STREET PAVEMENT, CURBS, SIDEWAL ASPHALT PATH FOR ANY UT L INSTALLATIONS IN THE RIGHT —OF —WAY WIT T E EXCEPTION OF CURB INLET CASTI <S, OR NGS. FIRE HYDRANT TO BE PRIVATE AR RED IN COLOR. 60 HOLEY MOLEY SAYS "DIG SAFELY" "IT'S THE LAW" CALL 2 WORKING DAYS BEFORE YOU DIG 1 -800- 382 -5544 CALL TOLL FREE PER INDIANA STATE LAW IC 8 -1 -26. IT IS AGAINST THE LAW TO EXCAVATE WITHOUT NOTIFYING THE UNDERGROUND LOCATION SERVICE TWO (2) WORKING DAYS BEFORE COMMENCING WORK. 1 00 N LO a.) cis C a) (1) O czt O ..7 O 0 z0 I E O) O 0 w ti 0 rx 0 d 0 0 z d Cn z 0 rx JAMES E. SHIELDS JR. P.E. 10201333 SHEET NO. 00 .--4 M 00 t 00 `!�DIA NP /ONAL ��iliilllllllll\ t M 00 0) CD CD L C U W U cm N C w 2 00 J c: J w d 0 rn 0 0 N C PROJECT NO DATED 6 4/2009 W09-0041 w V D