HomeMy WebLinkAbout09040009-10 Glick Indoor Self Storage Large Plan Pg 19Item Description 5/8" x 3/4" meters 1" meters 1 Meter Pit Cover with hole for touch read and plug Ford C3t Tyler 6150 A.Y. McDonald 74M3CTP Ford X43 —T Vestal 20X24r A.Y. McDonald 74-M43XTP 2 Yoke Ford Y502 Mueller HSO20 -203 A.Y. McDonald 14 -2 Ford Y504 Mueller HSO40 -330 A.Y. McDonald 14 -4 3 Street Side Angle Valve Ford AV94 -323WQ MUELLER b14273 A.Y. McDonald 4602Y— Q23/4X02 Ford AV94 -444WQ Mueller b24273 A.Y. McDonald 02- 4ye -44 4 H House Side Angle Check Valve g Ford HHA94 -323Q Mueller H14245 A.Y. McDonald 12 -3Y033 Ford HA91 -444 A.Y. McDonald 12- 3Ye -44 No Mueller for this part 5 Meter Pit Fratco HDPE Fiber 20 "w X 48 "d Mid State Soniloc Fiber 20 "w X 48 "d Mid State Soniloc Fiber 24 "w X 48 "d Fratco HDPE Fiber 24 "w X 48 "d 6 Service Line 3/4" K Copper 1 "K Copper 7 Corporation Stop Mueller H -15008 3/4" Ford F1000 -3Q A.Y. McDonald 47010 3/4" Mueller H -15008 1" Ford F1000 -4Q A.Y. McDonald 47010 1" 8 ALL METER PITS MUST HAVE 3/8" REBAR MOUNTING ROD PRESSURE PIPE JOINT RESTRAINT TABLE Length Of Pipe To Be Restrained In Each Direction From 1/4 Of Bend Based On 150 PSI Test Pressure Degree Of Bend 6" 8" 10" 17' 14" 16" 18" 20" 24" 30" 90 ",Tees Plugs 27' 35' 42' 50' 58' 65' 73' 80' 95' 115' 45" 7' 9' 11' 13' 15' 17' 19' 21' 24' 29' 22-1/2" 3' 4' 5' 6' 7' 8' 9' 10' 12' 14' 11-1/4" 2' 2' 3' 3' 4' 4' 4' 5' 6' 7' 0 U 0 0 U 5) E o 't I o a) 0 0 rn o N 0 0� 0 N D N C 0 z� o0 Li U8 9 G f2 10 10 9 Restrained Joints Shall Be Mechanical Joint With Retainer Glands, US Pipe TR Flex Joint System, US Pipe Field LOK Gasket System, Or Equal. NOTE: THE ABOVE RESTRAINED JOINT LENGTHS ARE MINIMUM LENGTHS THE DESIGN ENGINEER SHALL DETERMINE IF LONGER LENGTHS ARE REQUIRED. 9 CITY OF CARMEL STANDARD DETAILS 8 8 TITLE: JOINT RESTRAINT TABLE 7 Notes: 7 GRADE STANDARD METER PIT INSTALLATION FOR 5/8" X 3/4" AND 1" METERS Tapped Full -Cride Wrap Around Stainless Steel Service Clamp Water Main 0 HDPE Sleeve (Under Pavement) gS• d Tee M.J. *Service Saddle Must Be Omitted For Services 1" and Smaller and Direct Taps Made to Ductil Iron Pipe, Class 350 or Gretater. (Verify With Owner for Pressure Class DIP). *For all Service Lines Installed Under Pavement, Install HDPE Sleeve Under Pavement Section. 6 "Valve Box 0 U Length -Varies 6" Gate Valve 1. At High Points Along Main Water Line Where Indicated On Drawings, Anchoring Tee Shall Be Set At 45" Angle Upwards And Connected To 6" 45" Bend. Main Water Line Shall Be Lowered To Provide Sufficient Cover As Specified. 2. All Joints Shall Be Restrained Except In Run Of Tee. 3. Hydrants Shall Be Set At 500' Max. Horizontal Distance, Or Less As Specified By Fire Department 4. All valves must include Posi -Cap or equivalent 6 3/8" REBAR LENGTH WILL VARY HDPE Sleeve (Under Pavement) 2 Sn SERVICE LINE TO HOME NOT TO SCALE Copper Service Line Water Main Corporation Stop Copper Service Line NOTES: *Should meter pit need raised to grade, a Mid State Meter Box Extension should be used. No meter should be raised more than 6 without approval from Carmel Utilities. USING BRICKS OR CEMENT BLOCKS IS NOT AN APPROVED METHOD OF RAISING A METER PIT. *Should the meter lid need raised it should be done with a Ford Elevator Ring Part #ER15CX or ER3CX. *Service lines require compression fittings only. No Pack Joints Allowed. (No fittings should be made in the meter pit) Must have a continuous piece of copper from meter to at least 5' outside meter pit, on house side. *There shall be no buried joints or couplings, except for the corporation stop on the water main. *No pit shall be installed in a traffic area, such as a driveway or sidewalk. *The meter pit is to be installed just off the utility easement, on private property, in the middle of the lot 5' left or right of center, and as close to the easement line as possible. *THERE WILL BE A RE— INSPECTION FEE FOR EACH ADDITIONAL INSPECTION NEEDED. *METER PIT LID GRADE SHALL BE FLUSH WITH THE GROUND. (HOMEOWNER SHOULD BE ABLE TO MOW OVER LID) 6 5' 5' 3' -0" Hydrant Assembly Restrained Length And Fittings As Required Min. Lid Flush With Grade Block Riser DATE: MARCH 2007 CITY OF CARMEL STANDARD DETAILS SCALE: NOT TO SCALE Mueller Centurion A -423, Or Equal Painted "Safety Yellow" rn a) ca 5 1 -0" Min. One 8 "x8 "x16" Solid Conc. Block Or 6 "Min. Class "B" Concrete Base On Undisturbed ground. 5. Hydrant Valves must be restrained to the tee with either all thread, or an anchoring tee. CITY OF CARMEL STANDARD DETAILS 5 DRAWN BY: CROSSROAD ENGINEERS, PC TITLE: NOTE: 1) 1" or Smaller Service Line Shall be Direct Tap Unless Approved by Carmel Utilities. 2) Corporation Stop Shall be Brand and Model Approved by Carmel Utilities. 3) Service Line Tap Shall be Installed With a Minimum Horizontal Separation of 24" 4) 2" Taps and Smaller Shall not be Installed Within 18" of Mechanical Joints and Bells. TITLE: RESIDENTIAL WATER SERVICE (NO CURB STOP) DETAIL Bedding Material Conforming To INDOT 903.02, Size No. 8 DRAWING NAME: CW4 -3 FIRE HYDRANT ASSEMBLY 4 CITY OF CARMEL WATER UTILITY APPROVED LIST OF CONSTRUCTION MATERIALS 1) Water Main: Shall be Ductile Iron Pressure Class 350. 2) Blue Reflective Warning Tape: Shall be installed 18in above all water mains. 3) Tracing Wire (10 or 12 gauge): To be installed with all water mains. There must be access to the tracer wire at each valve box, with enough wire in the valve box to insure the proper connection to the locating machine. 4) Fire Hydrants: Shall be Mueller (Safety Yellow, M.A.B. 0433291, Sherwin Williams F75YP2) (Carmel Clay Spec. hydrants shall be open right and will have a safety blue stripe around hydrant bonnet from the factory). The hydrant pumper nozzle shall be of one —piece design, compatible with 5" Storz hose coupling. The nozzle shall be an integral part of the fire hydrant and must be furnished by the manufacturer or authorized distributor designated by the manufacturer. Mueller model 290220 for casting and 290221 for cap. Storz adapters will not be accepted. 5) Valves: Shall be resilient seat gate valve, Mueller only. (Carmel Clay Spec. valves shall be open right) Butterfly valves shall be used for sizes over 12in. 6) Fittings: Shall be Union, Tyler. 7) Mechanical Joints: Shall be made with Megalugs. 8) Valve Boxes: Shall be Union Tyler or East Jordan Iron Works. 9) Posi Caps or Box loks: Shall be installed, with each gate valve.* *not to be used on butterfly vavles. 10) Curb Boxes: Shall be Union, Tyler. 11) Tapping Sleeves: Shall be Smith Blair, Romac, or JCM 12) Repair Clamps: Shall be full circle stainless steel with ductile lugs. Smith Blair 226, Ford F -1, JCM or Mueller equal. 13) Tapped Repair Clamps: (For 3 /4,1 in, 11/2 in, and 2in taps on PVC, 11/2in and 2in on Ductile Iron and service repairs) shall be 12in long, full circle stainless steel with ductile lugs and tapered threads. Smith Blair, Ford, JCM, Mueller. 14) ample Stations: Shall be installed at the utilities request. (GIL Industries model EH 101). 15) Service Lines: 3 /4in, 1 in, 11/2in, 2in, Shall be K Copper. 16) Brass: Compression Fittings. Pack Joints not allowed (See Meter Pit Specs. For Make and Model 17) Joint Restrains' Shall be Field Lock Gaskets or Mechanical Bell Joint Restraints. 18) HDPE Sleeves: Shall be used for services that cross major city streets. 4 3 /4" Sc 1" lines will use 3" hdpe sleeve *1 1 /2" 2" lines will use 4" hdpe sleeve 19) Additional Kickers: Shall be solid block and brick. No poured concrete. WATER AND SEWER UNDER PAVEMENT, SIDEWALK, PAVED AREAS AND WITHIN RIGHT —OF —WAY BEDDING, HAUNCHING, INITIAL BACKFILL Bedding, Haunching and initial backfill requirements and compaction for water mains, water service laterals, sanitary mains and sanitary service laterals shall be in accordance with the standard practice of the utility that has jurisdiction over the installation. FINAL BACKFILL Final backfill for water mains, water service laterals, sanitary mains and sanitary service laterals under and within 5 —feet of pavement or sidewalk or other paved areas and for all installations within City right —of —way shall be B— Borrow for Structure Backfill meeting the material requirements of the INDOT. The material shall be approved by the City of Carmel Department of Engineering at time of installation. Final backfill shall be compacted in 6 —inch maximum lifts to not less than 95% Standard Proctor Density for the entire depth of the material placed. The backfill for the top 6— inches of the excavation below the start of the aggregate sub —base of the pavement shall be No. 53 Stone meeting the material requirement of the INDOT and shall be compacted to not less than 95% Standard Proctor Density. If the standard practice of the utility that has jurisdiction over the installation has a more stringent backfill requirement, the more stringent requirement shall govern. MINIMUM COVER FOR PIPE CROSSINGS WITHIN CITY RIGHT —OF —WAY For installation of Storm Mains, Water Mains, Sanitary Mains, Water Service Laterals, Sanitary Service Laterals under City streets, regardless of jurisdiction of the utility, the minimum cover from the top of the installed pavement to the top of the installed pipe shall be the pavement section thickness (all bituminous and aggregate material above the subgrade) plus 1 -0 but under no circumstances shall the cover along any part of the pipe from the final pavement elevation to the top of the pipe be less than 2.5 —feet. If the standard practice of the utility that has jurisdiction over the installation has a more stringent cover requirement, the more stringent requirement shall govern. Cove. heights for reinforced concrete pipe storm sewer that are less than those required will be evaluated on a case by case condition and approved only with written permission by the city engineer. DIGITAL AS —BUILT REQUIREMENTS City of Carmel Water Utilities requires two (2) sets of paper As— builts as well as two (2) digital copies drawn with AutoCAD Version 2004 or earlier. The As —built drawings must include streets, lots, water mains, and the measurements between all fittings, (valves, laterals, fittings, service lines). Water will not be turned on or approved until this requirement is fulfilled.' All valves, hydrants fittings, etc are REQUIRED to be captured using survey grade equipment as GPS points and submitted with As— builts. More information can be found in the City of Carmel Specs. TAC SUB HOLEY MOLEY SAYS "DIG SAFELY" "IT'S THE LAW" CALL 2 WORKING DAYS BEFORE YOU DIG 1 800 382 -5544 CALL TOLL FREE PER INDIANA STATE LAW IC 8 -1 -26. IT IS AGAINST THE LAW TO EXCAVATE WITHOUT NOTIFYING THE UNDERGROUND LOCATION SERVICE TWO (2) WORKING DAYS BEFORE COMMENCING WORK. 3 i CITY OF CARMEL UTILITY PIPE INSTALLATION All work shall be in the best practices of the water utility industry and the American Water Works Association, and in accordance with all applicable federal, state, and local codes and regulations. Furthermore: 1) Any damage done to the City of Carmel Water Utility's system by the contractor /developer or his affiliates shall immediately be repaired, to the satisfaction and direction of the City of Carmel Water Utility by the contractor /developer at his own expense. 2) Should the contractor /developer propose to depart from the specifications contained herein, he shall submit samples and /or specifications of such alternatives to the City of Carmel Water Utility before proceeding. 3) No work shall be performed under conditions which in the opinion of the City of Carmel Water Utility would adversely affect the quality of the finished job. 4) The contractor /developer shall conduct his work so as not to interfere with the present operation of the City of Carmel Water Utility's water /sanitary sewer system. If any work interference is encountered between the City of Carmel Water Utility and the contractor /developer, the City of Carmel Water Utility will receive priority in scheduling. CITY OF CARMEL WATER UTILITY DEVELOPER INSTALLED WATER MAINS 1) The developer will submit two (2) sets of preliminary plans for proposed development so the City of Carmel Water Utility can determine the main location and sizing, location of hydrants, service lines and valves to conform to the City of Carmel Water Utility's standards and specifications. 2) Developer will provide plans that conform to the City of Carmel Water Utility's standards for main extensions. In general, the City of Carmel Water Utility will respond within ten (10) business days. 3) Contractors shall call City of Carmel Water Utility for an on —site pre— construction meeting before work begins. Contractor must have approved plans on —site and all materials to be used must be approved by a City of Carmel Water Utility inspector. 4) Contractor will allow inspection by City of Carmel Water Utility inspectors during the construction of the water main extension and will honor the City of Carmel Water Utility's request for field changes in main extensions related to location, workmanship and materials as they relate to City of Carmel Water Utility standards and specifications. *AII Ductile Iron water mains shall be bedded in sand, from the bottom of the trench to 12" above the pipe. Blue Reflective Warning Tape must be installed 18" above all water mains. Tracer wire must be installed with all water main laid in Carmel. 5) The Contractor will have water main extensions pressure tested per City of Carmel Utility specifications and witnessed by City of Carmel Water Utility's inspector. The developer's contractor shall be billed for all bacteriological lab services. 6) The Contractor will conduct the disinfection of water main extension, with direct supervision by a City of Carmel Water Utility Operator. The Contractor will also be responsible for the de— chlorination of the water flushed off during disinfection process. 7) Only after the water main extension passes the City of Carmel Utility's laboratory testing, and two (2) sets of AS —BUILT plans and one (1) digital copy have been turned in to the City of Carmel Water Utility, will the water be turned on by the City of Carmel Water Utility. CITY OF CARMEL UTILITY GENERAL NOTES: 1) The contractor shall contact all applicable utilities and verify and and all fees associated with the installation of all utilities. 2) Provide thrust blocks for all water line bends and tees, including tab connection. 3) Contractor shall coordinate with water company for domestic and fire service. Connect to building domestic and fire line. Coordinate with plumbing drawings. 4) Coordinate location of electrical and telephone lines with local utilities. 5) Coordinate location and size of gas service connection and installation of service line and meter with gas company. 6) Coordinate locations and connections of building storm lines with mechanical /plumbing drawings. 7) Verify existing invert and location of sanitary sewer. Adjust inverts as required. Documem. any changes. 8) Maintain 10' horizontal and 18" vertical clearance between storm /sanitary sewer systems and domestic /fire line service. 9) Follow all local and state codes in reference to domestic /fire line installation and storm sewer /sanitary sewer installation. 10) Coordinate location of required conduits for light poles, telephone service and irrigation system. 11) Coordinate utility conduits with service providers. 12) Sanitary sewer laterals, water service, electrical /telephone conduits shall be B— borrow for structure backfill, meeting all current INDOT requirements. 13) There are to be no water valves or manholes placed within the pavement, curbs or sidewalks. 14) The developer shall verify the elevations of existing utilities and design plans accordingly. Existing infrastructure shall not be moved to accommodate new developments. TYPICAL WATER MAIN DEPTH 1. ALL PIPE SHALL HAVE A MINIMUM OF 54' COVER. JOINT 2 WATER MAIN LYING PARALLEL TO SEWER SECTION VIEW 1 /2 PIPE LENGTH WATER MAIN SAN ITAR OR STORM 10' MIN. FLOW i 18" MIN. 3' I I -I I- I III -I 11 -1 I I —II III -1 I 1/2 PIPE LENGTH WATER MAIN CROSSING SEWER SECTION VIEW WATER MAIN SANITARY OR STORM SEWER NOTE: WATER MAIN AND SANfFARY SEWERS SHALL BE PLACED IN SEPERATE TRENCHES. ANOTHER UTILITY FACILITY (TELEPHONE, GAS, ELECTRIC, CABLEVISION, ETC.) JOINT J WATER AND SEWER SEPERATION DETAIL ITTAL, DATED 6 /4 2009 1 DEPTH OF oc 07r- (1 o MI 0 vn 0 a; v)b• 3 O Q z U0 w 0 w 0 cn 0 z z 0 0 c) 0 W W w z 0 00 M 00 I- r GA CO Zm d 0 C) a) I` N cti cn J W JAMES E. SHIELDS JR. P.E. 10201333 ET NO. PROJECT NO. W09 -0041 col 0) 0 0 NI w 0