HomeMy WebLinkAbout09040024 Lowe's Outdoor Expansion Large Plan Pg 15REVISIONS
O PRE-BID SET A POST BID SET
ISSUE DATE L__. ISSUE DATE
DATE
DESCRIPTION
02/13/09
OWNER COMMENTS
W wwww W w..,�w
o `��L\ \Q,
s rift
W W
I ;41,
EXIST. MAIN
SHUTOFF
EXIST. YARD
HYDRANT SHUTOFF
3
EXIST. 1" C.W.
(U.G.)
EXIST. 1" C.W.
(U.G.)
WATER RISER
SCALE NOT TO SCALE
EXIST. RPZ
BACKFLOW
EXIST. PRESSURE
GAGE 0-100 PSI
EXIST. 1-1/2" C.W.
(OVERHEAD)
CONTRACTOR SHALL REMOVE
EXISTING YARD HYDRANT
AND CAP EXISTING. 3/4"
C.W. PIPING. FIELD VERIFY
LOCATION.
P.O.C.
(r
I
NEW HEAVY TRAFFIC RATED
STEEL OR CAST IRON VALVE
BOX WITH GATE VALVE. NEW
WATER CONNECTION SHALL
BE INSTALLED AFTER
EXISTING NON—POTABLE RPZ.
FIELD VERIFY LOCATION.
NEW 1" C.W.
NEW YARD
HYDRANT
NEW FROM
3/4" C.W. METER
2
NEW 3/4" C.W.
MASONRY WALL
ANGLE OR
FLANGE
SUPPORT
12"X 12"X 12"
GRAVEL FILL
EXIST. 2"
NON—POTABLE
WATER (U.G.)
(U.G.)
NEW
3/4" C.W.
NEW 1" C.W.
(U.G.)
1115:
ogi
11.411‘14.0.10 Eta
:440, 4.4$14 4■4001.,
Vir
4.404 OPEW0111.41
1 41. 014 4 gif el
40,101.4,4 &POO
rossiv.0040:04,101
011 ,trAllittral ib el %Mai
4 .P.4401.4 I
-AmPaavia,41111...., 4111■-.111110
THREADED ROD
iuii—
YARD HYDRANT DETAIL
CONTRACTOR SHALL REMOVE
EXISTING YARD HYDRANT
AND CAP EXISTING. 3/4"
C.W. PIPING. FIELD VERIFY
LOCATION.
SCALE NOT TO SCALE
NEW 3/4" C.W.
(U.G.)
NEW YARD
HYDRANT
NEW
3/4" C.W.
NEW YARD
HYDRANT
CONSTRUCTION NOTES
WRITTEN DIMENSIONS WITHIN THESE DOCUMENTS HOLD
PRECEDENCE OVER SCALED DIMENSIONS. ALL
CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL
EXISTING CONDITIONS AND DIMENSIONS PRIOR TO
SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY
CONDITIONS WHICH MAY INTERFERE WITH THE PROPER
EXECUTION OF CONSTRUCTION TO LOWE'S PROJECT
MANAGER. REPORT ANY DISCREPANCIES DURING BIDDING
PROCESS AND BEFORE START OF CONSTRUCTION. EXTRAS
WILL NOT BE ALLOWED FOR JOB OR CODE COMPLIANCE
CONDITIONS AFTER COMMENCEMENT OF CONSTRUCTION.
SUPPLY AND INSTALLATION RESPONSIBILITY:
ALL NEW FIXTURES AND MATERIALS SPECIFIED IN THESE
PLANS SHALL BE SUPPLIED BY AND INSTALLED BY THE
GENERAL CONTRACTOR UNLESS NOTED OTHERWISE.
3/4" C.W. SUPPLY
GROUND
(TYP.)
NEW YARD
HYDRANT
EXISTING WALL
HYDRANT (TYP.)
PLUMBER SHALL REFER TO THE GENERAL CONSTRUCTION, HVAC, FIRE PROTECTION, AND ELECTRICAL DRAWINGS FOR BUILDING CONSTRUCTION AND
COORDINATION WITH OTHER TRADES.
2. DO NOT INSULATE WATER PIPES IN SEASONAL DISPLAY AREA. WATER PIPING IN SHADE STRUCTURE AREA ABOVE FINISHED FLOOR AND WITHIN BUILDING
WALLS SHALL BE INSULATED WITH 3/4" FOAM PLASTIC PIPE INSULATION. ALL PIPE INSULATION SHALL BE RATED 25 FLAME SPREAD 50 SMOKE
DEVELOPED.
3. ALL WORK AND MATERIALS SHALL CONFORM TO STATE AND LOCAL CODES AND INSPECTIONS.
4. PRESSURE AT MOST REMOTE PLUMBING FIXTURE TO BE 25 PSI MINIMUM.
5. ALL YARD HYDRANTS SHALL BE PROVIDED WITH VACUUM BREAKER/BACKFLOW PREVENTERS. PROVIDE INDIVIDUAL CUT—OFFS
REQUIRED BY LOCAL CODES.
6. ALL WATER LINES IN GARDEN CENTER AREA SHALL BE COPPER.
7. ALL COPPER PIPING BELOW SLAB SHALL BE CONTINUOUS RUNS. ALL JOINTS SHALL OCCUR ABOVE SLAB.
YARD HYDRANT
(NFYH)
HOSE ASSEMBLY
i" COLD WATER. YARD HYDRANT SHALL BE FREEZELESS TYPE AND SHALL BE PROTECTED BY AN APPROVED
LABELED AS NON—POTABLE WATER. EQUAL TO: WOODFORD IOWA #Y34, JOSAM #71400, ZURN #Z1395, JAY
PLUMBING CONTRACTOR TO FURNISH AND INSTALL HOSE ASSEMBLY WITH EACH HOSE BIBB/YARD HYDRANT.
HOSE ASSEMBLY FROM ASHEVILLE HOSE EQUIPMENT, INC., 124 SWANNANOA RIVER ROAD, P.O. BOX 15366,
828-254-8302.
NEW HEAVY TRAFFIC RATED STE
OR CAST IRON VALVE BOX WITH
GATE VALVE. NEW WATER
CONNECTION SHALL BE INSTALLED
AFTER EXISTING NON—POTABLE RPZ.
FIELD VERIFY LOCATION.
EXIST. 1 C.W7/G.)
EXIST. 4"
(OVER
EXIST. 1-1
(OVERH
EXIST. 1-1 C.
(OVERHEA
EXI 1"
(OVERH
EXI 1" C.W.
(OVERHEAD)
EXIST. 3/4" C.W.
CONTRACTOR SHALL REMOVE
EXISTING YARD HYDRANT AT
EXISTING LIGHT POLE AND CAP
EXISTING 3/4" C.W. PIPING. FIELD
VERIFY LOCATION.
EXIST. —374" C.W.
(OVERHEA
FIXTURE SCHEDULE
PLUMBING NOTES
EXISTING
LIGHT POLE
NEW 1"
CONTRACTOR SHALL REMOVE
EXISTING YARD HYDRANT AND CAP
EXISTING 3/4" C.W. PIPING. FIELD
VERIFY LOCATION.
1
NEW 3/4" C.W.
EXIST. 2" C.W.
EXIST. 3/4 C.W. (U.G.
NEW 3/4" C.W.
NEW 1" C.W7
EXIST. 3/4 C.W.
(OVERHEAD) I
,VrlyMMIMM..■
TO YARD HYDRANTS AS
DOUBLE CHECK OR GREATER AND
R. SMITH #5909
SEE DETAIL THIS SHEET. ORDER
ASHEVILLE, NC, 28813. PHONE
3/4" C.W. (U.G.)
r EXISTING 2" NON—POTABLE WATER
SUPPLY WITH METER TO EXISTING HOSE
ASSEMBLIES AND WALL HYDRANTS OF
s EXISTING GREEN HOUSE STRUCTURE.
NEW 3/4" C.W. (U.G.)
NEW YARD HYDRANT— LOCATE AT
FENCE POST (VERIFY IN FIELD).
SEE DETAIL AND SCHEDULE THIS
SHEET (TYP. OF FOUR).
7---NEW 3/4" C.W. (U.G.)
GARDEN CENTER PLUMBING PLAN
SCALE: T 20'.-0°
NORTH
-III Al A ,111 ..41111.., 11".. AI,
HOME CENTERS, INC.
P.O. BOX 1111 N. WILKESBORO, NC 28658
11111111111111111111111111111111111111111=11.1.111111111.
11111111111:
cg
Le•
111211111111111111111111111111111111111111111111•111111111111111111•
PERMIT SET
ISSUE DATE:
CONSTRUCTION SET
ISSUE DATE:
DRAWING NUMBER:
P1
p- C"
c 00
0 1 7.
co
(O
4;6
0
w
c.)
1111111111111111111111111111111111111111111111111111111111111111111111111111
Ornwzz a. 0 0-1 f(f_
0 W o w 0
1: r: c'. 1 6
<_J <O<
Lu
Z 0 2 z
z u.,.. 7
w lil w 6
0 NIIIIIIIIIIIIIIIIIMIIIIIIIMIIIIIIMIIIIIMIII
ORIGINAL
ISSUE DATE: 01/09/09
�D