Loading...
HomeMy WebLinkAbout09040017 Lowe's Garden Center Expansion Approved pg 8"LP-1A" 277/480V., 30, 4W., S.N., 400A. M.L.O. USE (LABEL) LOAD DESCRIPTION II le li ::sEc Pti C I LOAD USE (LABEL) (KV) KW) KW) A B (KW) RECEIVING AREA LIGHTS 3.7 2.8 REC. AREA NT. LIGHTING E 20 10 1 me BE 10 1 60 �•MI a•III Mil E•0 10•• �•III 2 10 20 E 2.3 2.8 4.0 SALES AREA LIGHTING SALES AREA LIGHTING 4 10 20 E E 3.7 10 SALES AREA LIGHTING 3 RECEIVING AREA LIGHTS 4 3.7 20 E 20 10 3 SALES AREA LIGHTING 6 10 20 E E T 2.8 SALES AREA LIGHTING SALES AREA LIGHTING RECEIVING AREA LIGHTS SALES AREA LIGHTING 8 2.8 3.3 E 20 10 5 SALES AREA NT. LIGHTING 8 8 20 E 3.3 E 3.7 SALES AREA LIGHTING SALES AREA LIGHTING SALES AREA LIGHTING 3.3 T 2.9 E 20 10 7 r, 3.5 10 10 20 E 20 3.7 SALES AREA LIGHTING 10 SALES AREA LIGHTING SALES AREA LIGHTING 3.7 E 20 10 9 3.2 12 10 20 E 10 20 1.9 SALES AREA LIGHTING 20 3.3 SALES AREA LIGHTING SALES AREA LIGHTING 2.5 3.3 E 20 10 11 11 20 14 10 20 E 3.7 20 E SALES AREA LIGHTING SALES AREA LIGHTING 3.7 SALES AREA LIGHTING SALES AREA LIGHTING E 20 10 13 20 10 13 16 10 20 E 10 3.7 E SALES AREA LIGHTING SALES AREA LIGHTING 3.7 SALES AREA LIGHTING E 20 10 15 M ffin 161 10 15 18 8 30 E 10 30 1.9 SALES AREA /VEST. LIGHTING 1.9 SALES AREA LIGHTING COVERED AREA LIGHTS 3.7 E 20 10 17 17 20 10 20 E 3.3 20 10 SPARE (SWITCH) E SEASONAL AREA LIGHTS 2.3 SEASONAL AREA LIGHTS E 20 10 19 E 22 10 20 E 1.9 EXTERIOR WALL LIGHTS 10 20 GRDN CNTR POLE NT LTS 2.8 1.4 20 E 20 10 21 24 24 10 20 E 1.4 EXTERIOR WALL NT LTS GRDN CNTR POLE NT LTS E 0.9 E 20 10 23 AMIL r r 1.4 E 20 10 26 6 E 3.7 20 E ROAD SIGN GRDN CNTR SIGN 2.5 1.8 E 20 10 25 25 28 6 20 E T 3.7 BUILDING SIGN SPARE (SWITCH) 3.3 E 20 8 27 30 6 30 E 20 T 3.7 BUILDING SIGN SPARE (EMPTY) 2.2 E 20 8 29 20 32 10 32 E 2.4 E 1.4 RTU 21 GRDN CNTR POLE LTS BUILDING SIGN 3.6 E 20 8 31 34 10 20 E 20 2.4 EXTERIOR WALL LIGHTS 2.8 SITE LIGHTING E 20 8 33 36 10 33 E 2.4 EXTERIOR WALL NT LTS 8 20 3.0 E 20 8 35 SITE LIGHTING 38 4/0 2.2 X 35.8 8 35 SUB -FEED PANEL "LP-1B" RTU 20 6.7 38 X 8 37 40 4 0 200 X 33.5 E 6.7 37 X 30 8 39 40 8 20 E 42 4 0 X 2.2 30.4 E 20 6.7 X 8 41 42 8 PHASE A: 80.1 KVA PHASE B: 77.9 KVA PHASE C: 67.9 KVA TOTAL CONN. LOAD 225.9 KVA, 271.7 AMPERES 1.7 "LP-113" 277/480V., 30, 4W., S.N. 200A. M.L.O. USE (LABEL) LOAD DESCRIPTION II le li PHASE IU C I LOAD USE (LABEL) (KW) A B C KW) A B (KW) RECEIVING AREA LIGHTS 2.8 REC. AREA NT. LIGHTING 3.2 E 20 10 1 10 1 60 �•MI a•III Mil E•0 10•• �•III (Tl 2 10 20 E 2.8 4.0 SALES AREA LIGHTING RECEIVING AREA LIGHTS SALES AREA NT. LIGHTING 2.8 4.0 E 20 10 3 3 4 10 20 E T 3.7 3.1 SALES AREA LIGHTING SALES AREA NT. LIGHTING 6 10 20 E T 20 3.3 SALES AREA LIGHTING RECEIVING AREA LIGHTS 6 8 2.8 E 20 10 5 SALES AREA NT. LIGHTING SALES AREA NT. LIGHTING 3.6 8 10 20 E 3.7 SALES AREA LIGHTING SALES AREA LIGHTING 3.3 T 2.9 E 20 10 7 3.5 T 10 10 20 E 3.3 10 SALES AREA LIGHTING SALES AREA LIGHTING 3.7 E 20 10 g 3.2 T 20 10 12 10 20 E 10 20 3.3 SALES AREA LIGHTING SALES AREA LIGHTING 2.5 OVERSTOCK NT. LIGHTING 3.3 E 20 10 11 20 10 13 14 10 20 E 3.7 T 0.5 SALES AREA LIGHTING SALES AREA LIGHTING 3.7 SPACE ONLY E 20 10 13 15 16 10 20 E 3.7 SALES AREA LIGHTING SALES AREA LIGHTING 3.7 E 20 10 15 18 10 18 10 30 E 0.5 1.9 SEASONAL AREA LIGHTS COVERED AREA LIGHTS T 3.3 E 20 0 17 20 20 10 20 E 1.9 1.2 SEASONAL AREA LIGHTS COVERED AREA LIGHTS 3.7 21 E 20 10 19 22 10 20 E 2.8 1.4 20 GRDN CNTR FLOOD LTS COVERED AREA LIGHTS 3.7 24 E 20 10 21 24 10 20 E 2.8 SHADE STRUCTURE LIGHTS GRDN CNTR POLE LTS 1.4 E 20 10 23 26 10 20 E 2.8 SHADE STRUCTURE LIGHTS GRDN CNTR POLE LTS 1.8 E 20 10 25 28 20 T SPARE (SWITCH) SPARE T 20 27 30 20 T SPARE (EMPTY) SPARE T 20 29 32 10 20 E 1.4 GRDN CNTR POLE LTS SPACE ONLY 31 34 10 20 E 1.4 GRDN CNTR POLE LTS SITE LIGHTING 2.2 E 20 8 33 36 8 20 E 2.2 SITE NIGHT LIGHTING SITE LIGHTING 2.2 E 20 8 35 38 8 E 2.2 SITE NIGHT LIGHTING SITE LIGHTING 2.2 E 8 37 40 8 20 E 1.7 SITE NIGHT LIGHTING 2.2 E 20 8 39 42 8 E 1.7 SITE NIGHT LIGHTING 2.2 E 8 41 PHASE A: 35.8 KVA PHASE B: 33.5 KVA PHASE C: 30.4 KVA TOTAL CONN. LOAD 99.7 KVA, 120.0 AMPERES "ELS -1 277/480V., 30, 4W., S.N., 150A. M.L.O. (EMERGENCY LIFE SAFETY "ELS USE (LABEL) LOAD DESCRIPTION II 1 li 05/22/09/2\ PHASE C MU LOAD USE (LABEL) C") A B (KW) REC. AREA NT. LIGHTING 3.2 T 20 10 1 60 �•MI a•III Mil E•0 10•• �•III 2 10 20 T 4.0 THIS DRAWING IS THE PROPERTY OF LOWE'S HOME CENTERS, INC. ANY USE OR REPRODUCTION IN WHOLE OR PART IS PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF LOWE'S HOME CENTERS, INC. COPYRIGHT 2008 ALL RIGHTS RESERVED III 11111111111111111•111111111•111111111 i SALES AREA NT. LIGHTING SALES AREA NT. LIGHTING 4.0 T 20 10 3 4 10 20 T 3.1 SALES AREA NT. LIGHTING SALES AREA NT. LIGHTING 4.0 T 20 8 5 6 8 20 T 4.2 SALES AREA NT. LIGHTING SALES AREA NT. LIGHTING 3.6 T 20 8 7 8 8 20 T 2.9 SHADE STRUCTURE NT LTS SEASONAL AREA NT UGH11NG 3.5 T 20 8 g 10 10 20 T 4.2 COVERED AREA NT LTS OFFICE NIGHT LIGHTING 3.2 T 20 10 11 12 10 20 T 2.5 OVERSTOCK NT. LIGHTING LP OFFICE LIGHTING 1.0 T 20 10 13 14 10 T 0.5 SPACE ONLY 15 16 10 20 T 0.5 JOCKEY PUMP SPACE ONLY 17 18 10 T 0.5 OFFICE LIGHTS 1.2 T 20 10 1 9 20 SPACE ONLY OFFICE LIGHTS 1.2 T 20 10 21 22 SPACE ONLY OFFICE LIGHTS 2.8 T 20 10 23 24 SPACE ONLY TOTAL CONN. LOAD 50.1 KVA, 60.3 AMPERES PHASE A: 16.4 KVA PHASE B: 16.5 KVA PHASE C: 17.2 KVA REVISIONS P P ISSUE RE -BID DD A ISSUE OST DATE BID SET DATE DESCRIPTION 2/24/09 Q OWNER 05/22/09/2\ OWNER THIS DRAWING IS THE PROPERTY OF LOWE'S HOME CENTERS, INC. ANY USE OR REPRODUCTION IN WHOLE OR PART IS PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF LOWE'S HOME CENTERS, INC. COPYRIGHT 2008 ALL RIGHTS RESERVED III 11111111111111111•111111111•111111111 i EXISTING SWITCHGEAR CABINET O 0 O 0 0 0 0 I, V A 0 Iv A I EXISTING I 1 A V \A 0 F\ 0 0 0 0 0 0 0 0 0 0 CONSTRUCTION NOTES WRITTEN DIMENSIONS WITHIN THESE DOCUMENTS HOLD PRECEDENCE OVER SCALED DIMENSIONS. GENERAL CONTRACTOR MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF CONSTRUCTION TO LOWE'S PROJECT MANAGER. REPORT AND DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. EXTRAS WILL NOT BE ALLOWED FOR JOB OR CODE COMPLIANCE CONDITIONS AFTER COMMENCEMENT OF CONSTRUCTION. SUPPLY AND INSTALLATION RESPONSIBILITY: ALL NEW FIXTURES AND MATERIALS SPECIFIED IN THESE PLANS SHALL BE SUPPLIED BY AND INSTALLED BY THE GENERAL CONTRACTOR UNLESS NOTED OTHERWISE. 64 EXIST. '4 EXIST. /i 0 EXISTING 0 0 0 EXIST. F 0 0 0 EXI TING O EXISTING O POLE LIGHT TO BE REMOVED. 0 i EXIST. 0 0 0 0 0 EXISTING POLE LIGHT TO BE REMOVED. FL-1P 23 P -2 I RELOCATED EXIT SIGNAGE. REPLACE BATTERY AND VERIFY OPERATION FL -1 PD 23 0 0 GARDEN CENTER LIGHTING PLAN 0 SCALE: r saa SECURITY CONDUIT NOTES 1. INSTALL A 4 "X4 "X2" WEATHERPROOF JUNCTION BOX AT 4' -0" A.F.F. ON EITHER SIDE OF HINGE FOR SWING GATES. (LABEL AS S.S.) 2. PULL BOXES INDICATED ON THIS DRAWING ARE THE MINIMUM REQUIRED BY THE OWNER. THE ELECTRICAL SUB CONTRACTOR SHALL INSTALL ADDITIONAL PULL BOXES AS REQUIRED BY THE N.E.C. (ALSO, THE POS SYSTEM SHALL HAVE A PULL BOX EVERY 100 FEET MINIMUM WHETHER OR NOT INDICATED ON THE DRAWING). PROVIDE BLANK COVERS ON ALL PULL BOXES AND LABEL INSIDE OF COVER WITH A BOLD FELT TIP MARKER AS TO THE SYSTEM FOR WHICH THE BOX IS INSTALLED. 3. 1" SECURITY CIRCUIT (TYPICAL) TO BE ROUTED ALONG TOP OF THE FENCE AND SECURED PER THE NATIONAL ELECTRICAL CODE. 4. INSTALL A 4 "X4 "X2" WEATHERPROOF JUNCTION BOX AT PIPE RAIL AT APPROXIMATELY 12' -0" A.F.F. BESIDE THE SLIDING GATE ON THE LATCH SIDE AND EXTEND 1" CONDUIT DOWN TO 4' -0" A.F.F. 5. MOUNT A 4 "x4 "x2 -1/8" JUNCTION BOX ON PIPE RAIL APPROX. 1' -0" ABOVE THE CENTER OF GARDEN CENTER GATE. LABEL "SS NORTH EXISTING SWITCHGEAR CABINET INSTRUCTIONS FOR CIRCUIT ADDITIONS AND MODI 1. TIE NEW CIRCUIT IN SO THAT IT IS CONTROLLED WITH THE EXISTING GARDEN CENTER POLE LIGHT CIRCUITS LOCATED IN EXISTING PANEL 2H. LIGHTING KEYED NOTE 0 WIRE THROUGH EXISTING "ENERGY MANAGEMENT SYSTEM" CONTROLS. EXISTING NOTE 3 CONDUIT AND RACEWAY PLAN 40 SCALE: 1' aao NORTH ICATIONS BUILDING MANAGMENT SYSTEM INSTRUCTION SPECIAL NOTE: THE FOLLOWING INSTRUCTIONS FOR ADDING THE ABOVE MENTIONED CIRCUITS TO THE EXISTING ON -SITE "POWER DISTRIBUTATION CENTER" ARE BASED ON THE CONTROL DRAWINGS THAT THE SYSTEM WAS ORIGINALLY FABRICATED BY. SHOULD THESE INSTRUCTIONS NOT MATCH WHAT IS CURRENTLY ON -SITE THEN MODIFICATIONS WILL NEED TO BE MADE. SQUARE D SCHNEIDER ELECTRIC WILL NOT ACCEPT RESPONSIBILITY FOR EQUIPMENT THAT IS NOT WORKING PROPERLY DUE TO THE INSTRUCTIONS NOT BEING FOLLOWED OR DUE TO THE EXISTING ON -SITE SYSTEM NOT HAVING THE POINTS AVAILABLE AS LISTED BELOW. PANEL LP -1A: FOR CIRCUITS LP-1A-21 Sc 23 "GARDEN CENTER POLE NIGHT LIGHTS THESE CIRCUITS ARE CURRENTLY WIRED THROUGH CONTACTOR #9 THAT IS CONTROLED BY OUTPUT 6A. LP-1A Sc 23 CURRENTLY HAVE A 2 -POLE 20 AMP BREAKER INSTALLED. THIS BREAKER WILL NEED TO BE REMOVED AND (2) SINGLE POLE 20 AMP BREAKERS INSTALLED. ALSO, A SECOND NEUTRAL SHALL BE PULLED IF NOT USING THE 2 -POLE BREAKER AS A MULTI -WIRE BRANCH CIRCUIT. THESE TWO CIRCUITS ARE FOR THE PANEL LP-1B: FOR CIRCUITS LP-1A-23 25 "GARDEN CENTER POLE LIGHTS" THESE CIRCUITS ARE CURRENTLY WIRED THROUGH CONTACTOR #31 THAT IS CONTROLED BY OUTPUT 8. LP-1B 23 25 CURRENTLY HAVE A 2 -POLE 20 AMP BREAKER INSTALLED. THIS BREAKER WILL NEED TO BE REMOVED AND (2) SINGLE POLE 20 AMP BREAKERS INSTALLED. ALSO, A SECOND NEUTRAL SHALL BE PULLED IF NOT USING THE 2 -POLE BREAKER AS A MULTI -WIRE BRANCH CIRCUIT. FOR CIRCUITS LP-1B-32 34 "GARDEN CENTER POLE LIGHTS THESE ARE NEW CIRCUITS THAT WILL NEED TO BE WIRED THROUGH CONTACTOR #30 THAT IS CURRENTLY LISTED AS "SPARE" AND CONTROLLED BY OUTPUT 6B. CONTACTOR #30 MUST BE CONTROLLED BY OUTPUT 8 THE SAME AS CONTACTOR #31. THE COIL WIRE JUMPER FOR CONTACTOR #30 MUST BE MOVED TO OUTPUT 8 BY REMOVING IT FROM CONTACTOR #29 AND CONNNECTING IT TO CONTACTOR #31. CIRCUITS LP-1B-32 34 ARE "SPACE" THEREFORE (2) SINGLE POLE BREAKERS MUST BE INSTALLLED. PANEL ELS -1 CIRCUIT ELS -1 -9 IS A SINGLE POLE 20 AMP BREAKER LISTED AS "SEASONAL AREA NIGHT LIGHTING" UNDER SQUARE D'S RECORDS SAME AS WHAT IS SCHEDULE IN THESE PLANS, NO CHANGE ARE REQUIRED. CONTACT: KELLY MORRISON, ACCOUNT MANAGER SQUARE D /SCHNEIDER ELECTRIC SALISBURY NC AT 1- 800 868 -9662 MANUFACTURER OF SWITCH GEAR CABINETS FOR PROPER WIRING INFORMATION. HOME CENTERS, INC. P.O. BOX 1111 N. WILKESBORO, NC 28656 Z r -I U F- 0 w W ct w F- z w U z LU 0 Et 0 U) z 0 z (7) z a_ ct F- z LL1 0 z LL! 0 0 rn LL ca ao U Cr) O c o w I M CO 0 U-1 w o 5" (O 0 0 m co c o U "'M N N CO z I- LU O ORIGINAL ISSUE DATE: 01/09/09 PERMIT SET ISSUE DATE: CONSTRUCTION SET ISSUE DATE: DRAWING NUMBER: E2