HomeMy WebLinkAbout09040017 Lowe's Garden Center Expansion Approved pg 9MASONRY WALL
ANGLE OR
FLANGE
SUPPORT
1 9:14 4
114•010,. PADAlbeli
11101,004 Or 11 101
11111111111111
A
12 "X 12 "X 12"
GRAVEL FILL
I i k
ka
�s•
18'
SCALE NOT TO SCALE
THREADED ROD
SLAB
A
CONSThUCflON NOmS
WRITTEN DIMENSIONS WITHIN THESE DOCUMENTS HOLD
PRECEDENCE OVER SCALED DIMENSIONS. ALL
CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL
EXISTING CONDITIONS AND DIMENSIONS PRIOR TO
SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY
CONDITIONS WHICH MAY INTERFERE WITH THE PROPER
EXECUTION OF CONSTRUCTION TO LOWE'S PROJECT
MANAGER. REPORT ANY DISCREPANCIES DURING BIDDING
PROCESS AND BEFORE START OF CONSTRUCTION. EXTRAS
WILL NOT BE ALLOWED FOR JOB OR CODE COMPLIANCE
CONDITIONS AFTER COMMENCEMENT OF CONSTRUCTION.
SUPPLY AND INSTALLATION RESPONSIBILITY:
ALL NEW FIXTURES AND MATERIALS SPECIFIED IN THESE
PLANS SHALL BE SUPPLIED BY AND INSTALLED BY THE
GENERAL CONTRACTOR UNLESS NOTED OTHERWISE.
LOCAL FROST LINE
PLUS 18" 24"
MINIMUM)
3/4" C.W. SUPPLY
YARD HYDRANT DETAIL
EXIST. YARD
HYDRANT SHUTOFF
EXIST. 1" C.W.
(U.G.)
EXIST. MAIN
SHUTOFF
I I
WATER RISER
SCALE NOT TO SCALE
EXIST. 1-1/2" C.W.
(OVERHEAD)
EXIST. RPZ
BACKFLOW
EXIST. PRESSURE
GAGE 0 -100 PSI
CONTRACTOR SHALL REMOVE
EXISTING YARD HYDRANT
AND CAP EXISTING. 3/4"
C.W. PIPING. FIELD VERIFY
LOCATION.
NEW 1" C.W.
(U.G.)
P.O.C.
r
I
f
't 7
I NEW NEW HEAVY TRAFFIC RATED
STEEL OR CAST IRON VALVE
BOX WITH GATE VALVE. NEW
WATER CONNECTION SHALL
EXIST. 1" C.W. BE INSTALLED AFTER
(U.G.) EXISTING NON— POTABLE RPZ.
FIELD VERIFY LOCATION.
NEW FROM
3/4" C.W. METER
NEW 3/4" C.W.
EXIST. 2"
NON POTABLE
WATER (U.G.)
(U.G.)
NEW YARD
HYDRANT
NEW
3/4" C.
NEW 1" C.W.
(U.G.)
CONTRACTOR SHALL REMOVE
EXISTING YARD HYDRANT
AND CAP EXISTING. 3/4"
C.W. PIPING. FIELD VERIFY
LOCATION.
NEW
3/4" C.W.
NEW YARD
HYDRANT
NEW 3/4" C.W.
(U.G.)
NEW
3/4" C.W.
/7
NEW YARD
HYDRANT
GROUND
(TYP.)
NEW YARD
HYDRANT
EXISTING WALL
HYDRANT (TYP.)
PLUMBING NOTES
1. PLUMBER SHALL REFER TO THE GENERAL CONSTRUCTION, HVAC, FIRE PROTECTION, AND ELECTRICAL DRAWINGS FOR BUILDING CONSTRUCTION AND
COORDINATION WITH OTHER TRADES.
2. DO NOT INSULATE WATER PIPES IN SEASONAL DISPLAY AREA. WATER PIPING IN SHADE STRUCTURE AREA ABOVE FINISHED FLOOR AND WITHIN BUILDING
WALLS SHALL BE INSULATED WITH 3/4" FOAM PLASTIC PIPE INSULATION. ALL PIPE INSULATION SHALL BE RATED 25 FLAME SPREAD 50 SMOKE
DEVELOPED.
3. ALL WORK AND MATERIALS SHALL CONFORM TO STATE AND LOCAL CODES AND INSPECTIONS.
4. PRESSURE AT MOST REMOTE PLUMBING FIXTURE TO BE 25 PSI MINIMUM.
5. ALL YARD HYDRANTS SHALL BE PROVIDED WITH VACUUM BREAKER /BACKFLOW PREVENTERS. PROVIDE INDIVIDUAL CUT —OFFS TO YARD HYDRANTS AS
REQUIRED BY LOCAL CODES.
6. ALL WATER LINES IN GARDEN CENTER AREA SHALL BE COPPER.
7. ALL COPPER PIPING BELOW SLAB SHALL BE CONTINUOUS RUNS. ALL JOINTS SHALL OCCUR ABOVE SLAB.
FI SC
YARD HYDRANT
(NFYH)
HOSE ASSEMBLY
i" COLD WATER. YARD HYDRANT SHALL BE FREEZELESS TYPE AND SHALL BE PROTECTED BY AN APPROVED
LABELED AS NON— POTABLE WATER. EQUAL TO: WOODFORD IOWA #Y34, JOSAM #71400, ZURN #Z1395, JAY
PLUMBING CONTRACTOR TO FURNISH AND INSTALL HOSE ASSEMBLY WITH EACH HOSE BIBB /YARD HYDRANT.
HOSE ASSEMBLY FROM ASHEVILLE HOSE EQUIPMENT, INC., 124 SWANNANOA RIVER ROAD, P.O. BOX 15366,
828 254 -8302.
DOUBLE CHECK OR GREATER AND
R. SMITH #5909
SEE DETAIL THIS SHEET. ORDER
ASHEVILLE, NC, 28813. PHONE
EXIST. 1 C.W. (U.G.)
NEW HEAVY TRAFFIC RATED STEEL
OR CAST IRON VALVE BOX WITH
GATE VALVE. NEW WATER
CONNECTION SHALL BE INSTALLED
AFTER EXISTING NON— POTABLE RPZ.
FIELD VERIFY LOCATION.
EXIST. 3/4" C.W.
(OVERHEAD)
EXIST. 1-1/2" C.W.
(OVERHEAD)
EXIST. 1-1/2' C.W.
(OVERHEAD)
EXIST. 1 C.W.
(OVERHEAD)
EXIST. 1 C.W.
(OVERHEAD)
J
EXIST. 3/4" C.W. (U.G.)
CONTRACTOR SHALL REMOVE
EXISTING YARD HYDRANT AT
EXISTING LIGHT POLE AND CAP
EXISTING 3/4" C.W. PIPING. FIELD
VERIFY LOCATION.
EXIST. 3/4" C.W.
(OVERHEAD)
CONTRACTOR SHALL REMOVE
EXISTING YARD HYDRANT AND CAP
EXISTING 3/4" C.W. PIPING. FIELD
VERIFY LOCATION.
NEW 3/4" C.W. (U.G.) 1
EXIST. 2" C.W. (U.G.)
EXIST. 3/4 C.W. (U.G.)
NEW 1" C.W. (U.G.)
EXISTING
LIGHT POLE
NEW 1" C.W. (U.G.)
EXIST. 3/4 C.W.
(OVERHEAD)
NEW 3/4" C.W. (U.G.)
GARDEN CENTER PLUMBING PLAN 0
SCALE r NY-0'
NORTH
NEW 3/4" C.W. (U.G.)
EXISTING 2" NON— POTABLE WATER
SUPPLY WITH METER TO EXISTING HOSE
ASSEMBLIES AND WALL HYDRANTS OF
EXISTING GREEN HOUSE STRUCTURE.
NEW 3/4" C.W. (U.G.)
NEW YARD HYDRANT— LOCATE AT
FENCE POST (VERIFY IN FIELD).
SEE DETAIL AND SCHEDULE THIS
SHEET (TYP. OF FOUR).
NEW 3/4" C.W. (U.G.)
HOME CENTERS, INC.
P.O. BOX 1111 N. WILKESBORO, NC 28656
PRE -BID SET A POST BID SET
ISSUE DATE L ISSUE DATE
DATE
02/13/09
REVISIONS
DESCRIPTION
OWNER COMMENTS
THIS DRAWING IS THE PROPERTY OF LOWE'S HOME
CENTERS, INC. ANY USE OR REPRODUCTION IN
WHOLE OR PART IS PROHIBITED WITHOUT THE
EXPRESSED WRITTEN CONSENT OF LOWE'S HOME
CENTERS, INC. COPYRIGHT 2008 ALL RIGHTS RESERVED
z
J
w
F-
z
w
0
z
w
0 z
Q
0 a.
PERMIT SET
ISSUE DATE:
CONSTRUCTION SET
ISSUE DATE:
DRAWING NUMBER:
P1
M
co
O
N
5
0
z
Sin
IUZU
EP4p4
Oz�
zo U
O
N
6 IC
ao
CJ
U
c o
w
M
M
0
0
w
w
e
O
Liu O
E CD
ca
up 0 6
ce
o O
U CD
ix) °U M
r
z
o_
z
w
11
X
w
Et Q
w v
z LL p
W 0
rn
v
Z -J
w W w
CO
0
w
w
U
U
m
z
N
o
0
0
Q ci
oQo
0
a
I ORIGINAL
ISSUE DATE: 01/09/09