Loading...
HomeMy WebLinkAbout09040017 Lowe's Garden Center Expansion Approved pg 9MASONRY WALL ANGLE OR FLANGE SUPPORT 1 9:14 4 114•010,. PADAlbeli 11101,004 Or 11 101 11111111111111 A 12 "X 12 "X 12" GRAVEL FILL I i k ka �s• 18' SCALE NOT TO SCALE THREADED ROD SLAB A CONSThUCflON NOmS WRITTEN DIMENSIONS WITHIN THESE DOCUMENTS HOLD PRECEDENCE OVER SCALED DIMENSIONS. ALL CONTRACTORS MUST VISIT JOB SITE TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO SUBMITTING BIDS. REPORT ANY DISCREPANCIES OF ANY CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION OF CONSTRUCTION TO LOWE'S PROJECT MANAGER. REPORT ANY DISCREPANCIES DURING BIDDING PROCESS AND BEFORE START OF CONSTRUCTION. EXTRAS WILL NOT BE ALLOWED FOR JOB OR CODE COMPLIANCE CONDITIONS AFTER COMMENCEMENT OF CONSTRUCTION. SUPPLY AND INSTALLATION RESPONSIBILITY: ALL NEW FIXTURES AND MATERIALS SPECIFIED IN THESE PLANS SHALL BE SUPPLIED BY AND INSTALLED BY THE GENERAL CONTRACTOR UNLESS NOTED OTHERWISE. LOCAL FROST LINE PLUS 18" 24" MINIMUM) 3/4" C.W. SUPPLY YARD HYDRANT DETAIL EXIST. YARD HYDRANT SHUTOFF EXIST. 1" C.W. (U.G.) EXIST. MAIN SHUTOFF I I WATER RISER SCALE NOT TO SCALE EXIST. 1-1/2" C.W. (OVERHEAD) EXIST. RPZ BACKFLOW EXIST. PRESSURE GAGE 0 -100 PSI CONTRACTOR SHALL REMOVE EXISTING YARD HYDRANT AND CAP EXISTING. 3/4" C.W. PIPING. FIELD VERIFY LOCATION. NEW 1" C.W. (U.G.) P.O.C. r I f 't 7 I NEW NEW HEAVY TRAFFIC RATED STEEL OR CAST IRON VALVE BOX WITH GATE VALVE. NEW WATER CONNECTION SHALL EXIST. 1" C.W. BE INSTALLED AFTER (U.G.) EXISTING NON— POTABLE RPZ. FIELD VERIFY LOCATION. NEW FROM 3/4" C.W. METER NEW 3/4" C.W. EXIST. 2" NON POTABLE WATER (U.G.) (U.G.) NEW YARD HYDRANT NEW 3/4" C. NEW 1" C.W. (U.G.) CONTRACTOR SHALL REMOVE EXISTING YARD HYDRANT AND CAP EXISTING. 3/4" C.W. PIPING. FIELD VERIFY LOCATION. NEW 3/4" C.W. NEW YARD HYDRANT NEW 3/4" C.W. (U.G.) NEW 3/4" C.W. /7 NEW YARD HYDRANT GROUND (TYP.) NEW YARD HYDRANT EXISTING WALL HYDRANT (TYP.) PLUMBING NOTES 1. PLUMBER SHALL REFER TO THE GENERAL CONSTRUCTION, HVAC, FIRE PROTECTION, AND ELECTRICAL DRAWINGS FOR BUILDING CONSTRUCTION AND COORDINATION WITH OTHER TRADES. 2. DO NOT INSULATE WATER PIPES IN SEASONAL DISPLAY AREA. WATER PIPING IN SHADE STRUCTURE AREA ABOVE FINISHED FLOOR AND WITHIN BUILDING WALLS SHALL BE INSULATED WITH 3/4" FOAM PLASTIC PIPE INSULATION. ALL PIPE INSULATION SHALL BE RATED 25 FLAME SPREAD 50 SMOKE DEVELOPED. 3. ALL WORK AND MATERIALS SHALL CONFORM TO STATE AND LOCAL CODES AND INSPECTIONS. 4. PRESSURE AT MOST REMOTE PLUMBING FIXTURE TO BE 25 PSI MINIMUM. 5. ALL YARD HYDRANTS SHALL BE PROVIDED WITH VACUUM BREAKER /BACKFLOW PREVENTERS. PROVIDE INDIVIDUAL CUT —OFFS TO YARD HYDRANTS AS REQUIRED BY LOCAL CODES. 6. ALL WATER LINES IN GARDEN CENTER AREA SHALL BE COPPER. 7. ALL COPPER PIPING BELOW SLAB SHALL BE CONTINUOUS RUNS. ALL JOINTS SHALL OCCUR ABOVE SLAB. FI SC YARD HYDRANT (NFYH) HOSE ASSEMBLY i" COLD WATER. YARD HYDRANT SHALL BE FREEZELESS TYPE AND SHALL BE PROTECTED BY AN APPROVED LABELED AS NON— POTABLE WATER. EQUAL TO: WOODFORD IOWA #Y34, JOSAM #71400, ZURN #Z1395, JAY PLUMBING CONTRACTOR TO FURNISH AND INSTALL HOSE ASSEMBLY WITH EACH HOSE BIBB /YARD HYDRANT. HOSE ASSEMBLY FROM ASHEVILLE HOSE EQUIPMENT, INC., 124 SWANNANOA RIVER ROAD, P.O. BOX 15366, 828 254 -8302. DOUBLE CHECK OR GREATER AND R. SMITH #5909 SEE DETAIL THIS SHEET. ORDER ASHEVILLE, NC, 28813. PHONE EXIST. 1 C.W. (U.G.) NEW HEAVY TRAFFIC RATED STEEL OR CAST IRON VALVE BOX WITH GATE VALVE. NEW WATER CONNECTION SHALL BE INSTALLED AFTER EXISTING NON— POTABLE RPZ. FIELD VERIFY LOCATION. EXIST. 3/4" C.W. (OVERHEAD) EXIST. 1-1/2" C.W. (OVERHEAD) EXIST. 1-1/2' C.W. (OVERHEAD) EXIST. 1 C.W. (OVERHEAD) EXIST. 1 C.W. (OVERHEAD) J EXIST. 3/4" C.W. (U.G.) CONTRACTOR SHALL REMOVE EXISTING YARD HYDRANT AT EXISTING LIGHT POLE AND CAP EXISTING 3/4" C.W. PIPING. FIELD VERIFY LOCATION. EXIST. 3/4" C.W. (OVERHEAD) CONTRACTOR SHALL REMOVE EXISTING YARD HYDRANT AND CAP EXISTING 3/4" C.W. PIPING. FIELD VERIFY LOCATION. NEW 3/4" C.W. (U.G.) 1 EXIST. 2" C.W. (U.G.) EXIST. 3/4 C.W. (U.G.) NEW 1" C.W. (U.G.) EXISTING LIGHT POLE NEW 1" C.W. (U.G.) EXIST. 3/4 C.W. (OVERHEAD) NEW 3/4" C.W. (U.G.) GARDEN CENTER PLUMBING PLAN 0 SCALE r NY-0' NORTH NEW 3/4" C.W. (U.G.) EXISTING 2" NON— POTABLE WATER SUPPLY WITH METER TO EXISTING HOSE ASSEMBLIES AND WALL HYDRANTS OF EXISTING GREEN HOUSE STRUCTURE. NEW 3/4" C.W. (U.G.) NEW YARD HYDRANT— LOCATE AT FENCE POST (VERIFY IN FIELD). SEE DETAIL AND SCHEDULE THIS SHEET (TYP. OF FOUR). NEW 3/4" C.W. (U.G.) HOME CENTERS, INC. P.O. BOX 1111 N. WILKESBORO, NC 28656 PRE -BID SET A POST BID SET ISSUE DATE L ISSUE DATE DATE 02/13/09 REVISIONS DESCRIPTION OWNER COMMENTS THIS DRAWING IS THE PROPERTY OF LOWE'S HOME CENTERS, INC. ANY USE OR REPRODUCTION IN WHOLE OR PART IS PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF LOWE'S HOME CENTERS, INC. COPYRIGHT 2008 ALL RIGHTS RESERVED z J w F- z w 0 z w 0 z Q 0 a. PERMIT SET ISSUE DATE: CONSTRUCTION SET ISSUE DATE: DRAWING NUMBER: P1 M co O N 5 0 z Sin IUZU EP4p4 Oz� zo U O N 6 IC ao CJ U c o w M M 0 0 w w e O Liu O E CD ca up 0 6 ce o O U CD ix) °U M r z o_ z w 11 X w Et Q w v z LL p W 0 rn v Z -J w W w CO 0 w w U U m z N o 0 0 Q ci oQo 0 a I ORIGINAL ISSUE DATE: 01/09/09