HomeMy WebLinkAbout09030013 Private Golf Course - Reed Property Pg 8DWN BY: EAG CHKD. BY: EAG SCALE: 1" 60' DATE: 03/16/09 EARTHWORK 1. SCOPE OF WORK A. Extent: The work required under this section consists of all excavating, filling, rough grading and related items necessary to complete the work indicated on the drawings and described in the specifications. The Contractor shall notify in writing the owners and the Engineer of any changes, errors or omissions found on the plans or in the field before work is started or resumed. 1. In general, the items of work to be performed under this section shall include: clearing and grubbing, removal of trees and stumps (where required), protection of trees to remain, stripping and storage of topsoil, fill compaction and rough grading of entire site. 2. Excavated material that is suitable may be used for fills. All unsuitable material and all surplus excavated material not required shall be removed from the site. The location of durpp and length of haul shall be the Contractor s responsibility. 3. Provide and place any additional fill material from off the site as may be necessary to roduce the grades required. Fill obtained from off site shall be of kind and quality as specified for fills herein and the source approved by the Owner. 4. The Contractor shall accept the site as he finds it and shall remove all trash, rubbish and debris from the site prior to starting excavation. B. Work not included: The following items of i related work are specified and included in other sections of these specifications: 1. Excavation, grading and backfilling for utility lines 2. Storm drainage systems 3. Sanitary sewer systems 4. Streets and paving 5. Water supply system 2. BENCH MARKS Maintain carefully all bench marks, monuments and other other reference points; if disturbed or destroyed, Contractor shall contact engineer. Replacement shall be at Contractor's expense. 3. REMOVAL OF TREES A. Remove all trees and stumps from area to be occupied by road and surfaced areas. Removal of trees outside these areas shall only be done as noted on drawings or approved by the Owner. B. All brush, stumps, wood and other refuse from the trees shall be removed to disposal areas off of the site. Disposal by burning shall not be permitted unless proper permits are obtained (where applicable). The location of on -site bury pits shall be approved by the owner and the i Engineer if permitted. 4. PROTECTION OF TREES A. General Protection: The Contractor shall be responsible for the protection of tops, trunks and roots of existing trees on the project site that are to remain. Existing trees subject to construction damage shall be boxed, fenced or otherwise protected before any work is started; do not stockpile within branch spread. Remove interfering branches without injury to trunks and cover scars with tree paint. 5. HANDLING OF TOPSOIL A. Remove all organic material from the areas to be occupied by buildings, roads, walks and parking areas. Pile and store topsoil at a location where it will not interfere with construction operations. Topsoil shall be reasonably free from subsoil, debris, weeds, grass, stones, etc.. B. After completion of site grading and subsurface utility installation, top soil shall be replaced in areas design9ted on the erosion control plan for seeding and /or sod. Any remaining topsoil shall be used for finished grading around structures and landscaping areas. 6. DISPOSITION OF UTILITIES: A. Rules and regulations governing the respective utilities shall be observed in executing all work under this section. B. If active utilities are encountered but not shown shown on the drawings, the Engineer shall be advised before work is continued. C. Inactive and abandoned utilities encountered in excavating and grading operations shall be reported to the Engineer. They shall be removed, plugged or capped as directed by the Utility Company or the Engineer. D. It shall be the responsibility of each contractor to verify all existing utilities and conditions pertaining to his phase of the work. It shall also be the contractors responsibility to contact the owners of the various utilities before work is started. 7. SITE GRADING: A. Grades: Contractor shall perform all cutting, filling, compacting of fills and rough grading required to bring entire project area to grade as shown on the drawings. B. Rough Grading: the tolerance for paved areas shall not exceed 0.10 feet plus or minus above the established subgrade. All other areas shall not exceed 0.10 feel plus or minus the established grade. All banks and other breaks in grade shall be rounded at top and bottom. C. Compaction Requirements: 1. All areas under building ads and paved areas shall be compacted to 100% standard proctor density. 2. All other fill areas shall be compacted to 90% standard proctor density. 3. All areas where cut is necessary to meet the design sub -grade are required to be scarified 12 inches below sub -grade and meet the above compaction requirements. 8. EARTH WORK BALANCE A. The Contractor shall confirm all earthwork quantities prior to start of construction. If an excess or shortage of earth is encountered, the Contractor shall confirm with the Owner and Engineer the requirements for stockpiling, removal or importing of earth. B. Minor adjustments to the grades may be required to earthwork balances when minor excess material or shortages are encountered. It is recognized by the parties hereto that the calculations of the the Engineer in determining earthwork quantities shall be accomplished in accordance with the American Society of Civil Engineers Standards for such calculations. Further, that these calculations are subject to the interpretations of soil borings as the physical limits of the various soil types, the allowable variation in finish grade and compaction permitted the contractor, and that all of these parameters may couse either an excess or shortage of actual earthwork materials to complete the project. If such an actual minor excess or shortage of materials occurs, the contractor shall contact the Engineer to determine if adjustment can be made to correct the imbalance of earth. 9. TESTING A. Contractor shall hire at Contractors expence an independent soil testing service to assure soil compaction with scope of testing to be approved by Engineer. Copies of test results shall be submitted no the Engineer. STORM SEWER SYSTEMS 1. SCOPE OF WORK The work under this section includes all storm sewers, storm water inlets, and related items, including excavating and backfilling, necessary to complete the work shown on the drawings. All work and materials shall meet local specifications. 2. MATERIALS A. Storm Sewers B. Manholes C. SUBDRAINS 3. APPLICATION 1. Reinforced concrete sewer pipe shall conform to ASTM C -76 latest revision, with joints conforming to ASTM C -443 latest revision when storm pipe is located within public right -of -way. 2. Aluminized type 2 corrugated steel pipe shall e manufactured ir) acco dance with AASHTO M36 ttpe I with,, 2 x 1/2 corrugation ,for T and 15 diameters; type IR with 3/4 x 3/4 x 7 1/2" corrugations for 18 diameter and larger). The pipe shall be formed from an aluminized steel type 2 coil that conforms to AASHTO M274. The minimum gage thickness of the pipe shall be as follows: Diameter Gage 12" 36" 42" 48" 14 54" 84" 12 3. High density pol th ene pipe shall perform to AASHTO M252 and m2 Type S specifications, latest revision, and shall have material specifications conforming to ASTM D1248 or D3350, latest revision. 1. Precast reinforced concrete manhole sections and steps shall conform to ASTM C -478 latest revision. 2. Casting shall be of uniform quality, free from blow holes porosity, hard spots, shrinkage distortion or other defects. They shall be smooth and well cleaned by shot blasting or by some other approved method. They shall be coated with asphalt paint which shall result in a smooth coating, tough and tenacious when cold, not tacky or brittle. They shall be gray iron meeting ASTM A -48 latest revision. 3. Joints Manhole sections shall be jointed with rubber type askets. The rubber type gaskets shall meet ASTM C -443 latest revision. When manhole and storm pipe are continuously in water. 4. Shop Drawings Contractor to submit storm sewer structure recast drawings to engineer for approval prior to installation. 1. Perforated plastic _pipe subdrains shah conform to ASTM F -405, AASHTO M -252 (4 to 10 pipe). A. Permits and Codes The intent of this section of the specifications is that the contractor's bid on the work covered herein shall be based upon the drawings and specifications but that the work shall comply with all applicable codes and regulations as amended by any waivers. Contractor shall furnish all bonds necessary to get permits for cuts and connections to existing sewers. Contractor shall notify the local governing jurisdiction a minimum of 72 hours prior to the commencement of storm sewer construction. B. Local Standards the term "Local Standards" as used herein means the standards of design and construction of the respective municipal department or utility company. C. Existing Improvements Maintain in operating condition all active utilities, sewers and other drains encountered in the sewer installation. Repair to the satisfaction of the owner any damage to existing active improvements. D. Workmanship To conform to all local, state and national codes and to be approved by all local and state agencies having jurisdiction. E. Trenching Lay all pipe in open trenches, except when the local authority gives written permission for tunneling. Open the trench sufficient ahead of pipe laying to reveal any obstructions. The width of the trench shall be the inside pipe diameter plus 24 inches for 12 inches above the pipe. Sheet and brace trench as necessary to protect workmen and adjacent structures. All trenching to comply with Occupational Safety and Health Administration Standards. Keep trenches free from water while construction is in progress. Under no circumstances lay pipe or appurtenances in standing water. Conduct the discharge from trench dewatering to drains or natural drainage channels. F. Special Supports Whenever in the opinion of the Engineer the soil at or below the pipe grade is unsuitable for supporting sewers and appurtenances specified in this section, such special support, in addition to those shown or specified, shall be provided as the Engineer may direct, and the contract will be adjusted. G. Backfilling for a depth of at least 12 inches above the top of the pipe, backfill with earth or granular material free from large stones, rock fragments, roots or sod. Tamp this backfill thoroughly, taking care not to disturb the pipe. For the remaining trench depth, backfill with earth or granular material containing stones or rocks not larger than 4 inches. Backfill under and within 5 feet of City pavement and City sidewalks to conform to City backfill standards. H. Manhole Inverts Construct manhole flow channels of concrete sewer pipe or brick, smoothly finished and of semicircular section conforming to the inside diameter of the connecting sewers. Make changes in size or grade gradually and changes in direction by true curves. Provide such channels for all connecting sewers at each manhole. I. Subdrains All subdrains shall be of the size shown on the plans and shall be constructed to the grades shown. All drains constructed off -site as part of the outlet drain will be located as shown. J. Utilities It shall be the responsibility of each contractor to verify all existing utilities and conditions pertaining to his phase of the work. It shall also be the contractors responsibility to contact the owners of the various utilities before work is started. The contractor shall notify in writing the owners or the engineer of any changes, errors or omissions found on these plans or in the field before work is started or resumed. STREETS AND PAVING 1. SCOPE OF WORK A. The work required under this section includes all concrete and bituminous paving and related items necessary to complete the work indicated on drawings and described in the specifications, including but not limited to: All streets, parking areas in contract limits Curbs and gutters. Sidewalks and concrete slabs, exterior steps. 2. MATERIALS A. Concrete Concrete shall be read mixed concrete and shall be a mix of proportioned fine and coarse aggregates with Portland cement and water. Minimum cement content shall be 6 bags per cubic yard of concrete and maximum water content shall be 5.5 U.S. gallons per sack of cement, including moisture in the aggregate. Slump for normal weight concrete shall be a maximum of 4 inches and a minimum of 2 inches. The slump of machine place concrete shall be no less than 1 -1/4 inches nor more than 3 inches. Standard test ASTM C -143 shall be used to measure slump. Compressive strength of concrete at 28 days shall be 4000 psi. All exterior concrete shall have air entrainment of 5% to 8% by volume per ASTM C -260. Retempering delivered concrete will not be allowed. Concrete shall be composed of: 1. Portland cement Conforming to ASTM C -150, Type IA or Type IIIA. 2. Aggregates: Conforming to ASTM C -33 3. Water Shall be clear and free from injurious amounts of oils, acids alkalis, organic materials or other deleterious substances. B. Welded Steel Wire Fabric Where required for concrete reinforcement shall conform to ASTM A185. C. Premoulded Joint Filler Shall be of non extruding type meeting ASTM D -544 except that premoulded joint filler used in concrete walk construction may be either non extruding or resilient. D. Bituminous Pavement Materials All materials proposed for the construction of bituminous pavements shall comply with the Indiana Department of Transportation specifications, per latest revision. E. Compacted Aggregate Subbase: Shall be crushed stone or gravel. Crushed gravel shall be a minimum of 35% crushed material. Chert shall be limited to a maximum of 8% of the total. Material shall be free from an excess of flat, elongated, thinly laminated, soft or disintegrated pieces; and shall be free from fragments coated with dirt. Compacted aggregate shall be graded as follows: 3. APPLICATION SIEVE SIZE 1" 1/2 1f2" 0 00 PASSING 100 80 -100 70 -90 55 -80 35 -60 25 -50 12 -30 5 -10 A. Grading Do any necessary grading in addition to that performed in accordance with Earthwork Section, to bring subgrades after final compaction, to the the grades and sections for site improvement. B. Preparation of Subgrade Remove spongy and otherwise unsuitable material and replace with stable material. No traffic will be allowed on prepared subgrade prior to paving. C. Compaction of Subgrade The first 12 inches below the subgrade shall be compacted to at least 100% of the maximum dry density as determined by the provisions of AASHTO T -99. Water shall be prevented from standing on the compacted subgrade. D. Compacted Aggregate Subbase the thickness shown on the drawings is the minimum thickness of the fully compacted subbase. Compaction shall be accomplished by rolling with a smooth wheeled roller weighing 8 to 10 tons. Compact to 95% standard proctor density (ASTM D698) Along curbs, headers and walls and at all placed not accessible to the roller, the aggregate material shall be tamped with mechanical tampers or with approved hand tampers. E. Bituminous Pavement Hot asphalt concrete pavement shall be as specified in Section 400 -410 of the Indiana Department of Transportation Specifications latest revisions. Paving will not be permitted during unfavorable weather or when the temperature is not in compliance with section 401.05 of the INDOT Specifications. F. Utility Structures Check for correct elevation of all manhole covers, valve boxes and similar structures located within areas to be paved, and make, or have made, any necessary adjustments in such structures. G. Placing Concrete 1. Subgrade Place concrete only on a moist, compacted subgrade or base free from loose material. Place no concrete on a muddy or frozen subgrade. 2. Forms All forms shall be free from warp, tight enough to prevent leakage and substantial enough to maintain their shape and position without i ringing or settling, when concrete is placed. Forms shall be clean and smooth and coated with form release before placement of concrete. 3. Placing Concrete Concrete shall be deposited so as to require as little rehandling as practicable. When concrete is to be placed at an atmospheric temperature of 35 degrees F. or less, paragraph 702.10 of the Indiana Department of Transportation Specifications latest revision shall be followed. REVISION RECORD REV DATE UTILITIES 1. 2. WATER GAS 3. OTHER UTILITIES DESCRIPTION H. Concrete Curb 1. Expansion Joints Shall be 1/2 inch thick premoulded at ends of all returns and at a maximum spacing of 100 feet. 2. Contraction Joints Unless otherwise provided, contraction joints shall be sawed joints spaced 20 feet on center. 3. Finish Tamp and screed concrete as soon as placed, and fill any honey coLnbed places. Finish square corners to 1/4 radius and other corners to radii shown. I. Concrete Walks and Exterior Steps 1. Slopes Provide 114 inch per foot cross slope. Make adjustments in slopes at walk intersections as necessary to provide proper drainage. 2. Dimensions Walks and steps shall be one course construction and of widths and details shown on the drawings. 3. Finish Screed concrete and trowel with a steel trowel to a hard dense surface after surface water has disappeared. Apply medium broom finish and scribe optrol joints at 5 foot spacing. Provide 1 2 expansion joints where sidewalks intersec and at a maximum spacing of 48 feet between expansion joints. J. Curing Concrete Except as otherwise specified, cure all concrete by one of the methods described in Section 501.17 of the Indiana Department of Transportation Specifications, latest revision. A. All water mains shall be installed and tested in accordance with local standards and requirements. Gas mains shown in the plans are for information only. The local gas utility is responsible for final design and installation of new gas mains. Electric, Telephone, and CAN lines shown in the plans are for information only. The local utility companies are responsible for final design and installation of their respective utility lines. DES BY 4. IDENTIFICATION LOCATION Furnish and install "Identification Tape" and "Location Wire" over the centerline of buried utilities. A. Identification Tape 1. Inert Polyethylene with minimum thickness of 4 -mils and shall have a 1 -mil thick metallic foil core. Tape width shall be a minimum of 3 inches and a maximum of 6- inches. Imprinted text shall be "Caution Caution Utility Buried Below" and should repeat itself once every 2 feet, for the entire pipe length. Install approximately 18 inches above the centerline of pipe. 2. "Terra Tape" as manufactured by Reef Industries, Inc., Houston, TX, or approved equal. B. Location Wire 1. Location wire shall be a 12 gauge insulated, solid copper wire. The wire shall be contiguous with no fabricated, or field constructed connections interrupting the wires continuity from end to end of pipe. 2. Location wire shall be installed no greater than 6- inches in height above the top of the buried pipe. II. Bentonite A. Materials and installation method to be reviewed by the testing engineer and approved by the Engineer. III. Synthetic Liner B. Materials and installation method to be reviewed by the testing engineer and approved by the Engineer APP BY LAKE LINER NOTE (SHOULD NOT BE REQUIRED FOR EXISTING PONDS) In order to minimize water level fluctuations within the lake area(s), it may be necessary to construct a liner to seal the more permeable sandy clays and sand seams which may be present on site. Acceptable liners are as follows: I. Natural Clay Liner A. Laboratory testing shall be performed on the designated liner material to determine the optimum liner compaction criteria. Subsequent to determining this compaction criteria, permeability testing shall be performed on remolded samples, compacted to this standard. Laboratory testing shall be performed at least one (1) month prior to initiating lining activities. B. The contractor shall identify and retain the engineer- approved liner material for use on sealing the side slopes and bottom of the lake(s). The optimum natural liner material shall not be used for other portions of site work prior to verification that adequate resources are available and have been stockpiled. It is important that the stockpiled soils be stored in as small an area as possible to retain natural moisture. The contractor should anticipate that additional soil work may be required to bring the liner material to required uniform moisture level. C. A representative of the testing engineer shall be present for inspection of the base and side slopes of the lake(s) prior to and during compaction of the liner materials. D. The clay lining material, approved by the testing engineer, shall be compacted to a minimum of 12 inches thick on the upper two thirds of the side slopes and 18 inches on the lower one third. A compacted minimum of 18 to 24 inches approved lining material shall be placed across the base of the lake. E. The clay liner material shall be regularly sampled and tested for conformance to the moisture and Atterberg limits established for the approved liner material(s). Field density and moisture testing shall also be performed frequently during construction to establish a correlation between density and field permeability. It is imperative that moisture levels be maintained over optimum as determined in laboratory testing. Only by maintaining this condition will it be possible to approach the zero voids condition and maximize natural liner capabilities. Off -site sources for day liner material may be used with approval by the Owner's representative and one -site testing engineer. F. Compaction of the natural liner shall be performed by equipment operating up and down the slope. Engineered natural clay liners shall not be compacted by equipment operating around the slopes on or near the same elevation. It is important that hydration of the clay liners takes place after installation is complete. This is typically accomplished by natural rainfall or by application of fresh water at the rate of one quarter gallon per square foot for at least 72 hours. This recommended rate of hydration will help prevent shrinkage and cracking of the clay liner and maintain its integrity. CID sor 1� C/3 1� 1� t) O CV Q? J 4. Nt CD a) LLi t` D (O 0 0 0 Z a 0 N 0 Li 0_ O 1 i ttg ll i.. ms s PE10403858 4. G P `S' a Y N� T STATE OF -o 111. i P o e o� OIANP:` F G s G L EIS SS /ONA1 ��ttt������� (Z DATE: 03/19/09 PROJECT NUMBER MSI.023 DRAWING NUMBER C11.0 SHEET 8 OF 8