Loading...
HomeMy WebLinkAboutPg 4 A1.2 First Floor: Equipment, Doors, Frame ElevationsWALLTYPE SCHEDULE 5/8" GWB (ONE SIDE) ON 3 5/8" STEEL STUDS 0 16" OC a 00 W11 5/8" GWB (EACH SIDE) ON 3 5/8" STEEL STUDS AT 16" OC WITH SOUND ATTENUATION FULL HEIGHT W28 WALL TO 4" MINIMUM ABOVE HIGHEST ADJACENT CEILING. W #A ONE LAYER GWB TO DECK ABOVE WITH SOUND ATTENUATION WHERE APPLICABLE. WtE W #H WINDOW TYPES F FLUSH DOOR DOOR TYPES DOOR NUMBER A101 -A A101 -B A103 -A A104 -A M 05 -A DOOR SIZE SIZE w N 0 0 3' -0" x 7' -2" 3' -0" x 7 -2" 3' -0" x 7' -2" 3' -0" x 7' -2" PR 3' -0" x 7' -2" STC RATING 45 -49 WALL CONSTRUCTION ABOVE CEILING SEE WALL CONSTRUCTION BELOW CEIUNG FOR WALL CONSTRUCTION EXTEND (1) LAYER GWB SIDE) TO DECK /STRUCTURE CMU TO STRUCTURE ABOVE, GWB TO 4" ABOVE FINISH CEIUNG. CMU BOND BEAM LAST FULL COURSE 9 -2 DOOR MAT. WD AL WD WD AL z =M al MI twol SEE WALL CONSTRUCTION BELOW CEILING FOR WALL CONSTRUCTION t a a 00 WI FRONT WI SIDE TYPE N FGAL2 F F FGAL2 EQ. FI F2 DOOR FRAMETYPES MAT. HM AL HM HM AL NARROW UTE DOOR TYPE F1 F1 F1 F1 SIZE 5/8" GWB (EACH SIDE) ON 3 5/8" STEEL STUDS 0 16" OC W12 4" FACEBRICK W48 i 2' 0" t EQ. w N 8 JAMB DEPTH 6" 4 1/2" 6" 6" 4 1/2" FINISH CEILING -SEE REFLECTED CEILING PLANS CMU BOND BEAM FRAME HEAD 10/A1.4 13/A1.4 10/A1.4 10/A1.4 WALL CONSTRUCTION BELOW CEILING STEEL STUD BRACING (4' -0" OC MAX) SOUND /ACOUSTICAL INSULATION FULL HEIGHT (IF APPLICABLE) I=== -FINISH CEILING SEE REFLECTED CEIUNG PLAN a N a 00 HOLD TOP OF CMU 2" FROM BOTTOM OF DECK /STRUCTURE. CUT CMU, WHERE APPLICABLE, TO ACCOMMODATE 2" DIMENSION. PACK 2" VOID W/ MINERAL WOOL (0 NON- RATED) AND FIRESTOPPING (0 RATED) DETAILS JAMB 11/A1.4 14/A1.4 11/A1.4 11/A1.4 a CV t FULL GLASS 2 SILL 12/A1.4 STC RATING 40 -44 \I\ STC RATING 41 STEEL STUD BRACING (4' -0" OC MAX) FIRE RATING IN MINS. 4' -0" t W2 HARDWARE KEYSIDE SET ROOM NO. NO. GENERAL NOTES W1A 1. WALL TYPE AS SHOWN: "1" REFERS TO WALL CONSTITJCTION BELOW CEILING "A" REFERS TO WALL CONSTRUCTION ABOVE CEILING. 2. REFER TO CODE PLANS FOR RATED AND NON -RATED WALLS EXTENDING TO DECK. 3. REFER TO ROOM FINISH SCHEDULE SCHEDULE FOR WALL FINISHES 4. REFER TO STRUCTURAL DRAWINGS FOR HORIZONTAL AND VERTICAL REINFORCING 0 MASONRY WALLS 5. PROVIDE DEEP LEG TRACK 0 ALL STEEL STUDS THAT EXTEND TO DECK /STRUCTURE ABOVE (UNO) PACK VOIDS 0 NON -RATED WALLS W/ MINERAL WOOL PACK VOIDS 0 RATED WALLS W/ FIRESTOPPING PROVIDE SOUND INSULATION 0 NON -RATED WALLS THAT REQUIRE SOUND ATTENUATION. REFER TO CODE PLANS FOR WALL RATING. PROVIDE ACOUSTICAL INSULATION 0 RATED WALLS THAT REQUIRE SOUND ATTENUATION. REFER TO CODE PLANS FOR WALL RATING. SCALE 1/4" 1' -0" SCALE 1/4" 1' -0" DOOR AND FRAME SCHEDULE 7/8" STEEL FURRING AND 5/8" GWB ON EXTERIOR WALL (SEE WALL SECTIONS) W18 a 00 1' REMARKS SEE SECTION 080050 6' -0" W3 SCALE 1/4" 1' -0" 1. THE BOTTOM OF GLASS UTES FOR ALL DOORS, EXCEPT FULL GLASS DOORS(I.E. FG, N2), MUST BE AT A MINIMUM OF 43" ABOVE FINISHED FLOOR TO ALLOW FOR EXIT DEVICE MOUNTING. THIS LOCATION WILL EUMINATE GLASS AND EXIT DEVICE INTERFERENCE. IT WILL ALSO ELIMINATE THE USE OF EXIT DEVICE SHIM KITS TO RAISE THE DEVICE OVER THE GLASS BEAD. 2. THE TOP DOOR RAIL DIMENSIONS, AS SHOWN ON THE DOOR TYPES, ARE REQUIRED FOR MOUNTING CLOSERS WITHOUT THE USE OF A DROP PLATE. THESE DIMENSIONS WILL ALSO PREVENT THE CLOSERS FROM BEING SEEN THROUGH THE GLASS ON THE OUTSIDE. 3. THE BOTTOM DOOR RAIL HEIGHT DIMENSION SHALL BE 10" TO CONFORM WITH VARIOUS STATE ADA BARRIER -FREE CODES. 4. THE STANDARD MOUNTING HEIGHT FOR EXIT DEVICES IS 40" TO CENTERUNE ABOVE FINISHED FLOOR. 5. GLASS UTE SIZE, AREA, AND LOCK -TO -CITE CUT -OUTS, AS SHOWN ON DOOR TYPES, CONFORM WITH MANUFACTURER'S LIFETIME WARRANTY AND FIRE RATED REQUIREMENTS. 6. FIRE RATING IN MINUTES 20 20 MINUTES GLASS ALLOWED IN DOOR -1296 SQ. INCHES 45 C LABEL 3/4 HOUR GLASS ALLOWED IN DOOR -1296 SQ. INCHES 60 B LABEL 1 HOUR GLASS ALLOWED IN DOOR -100 SQ. INCHES 90 B LABEL 1-1/2 HOUR GLASS ALLOWED IN DOOR -100 SQ. INCHES 180 A LABEL 3 HOUR GLASS ALLOWED IN DOOR -NONE 1111111111 111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111 1111111111111111111 I BO1B 7 ,IIIII111111111IIIIII 1111111" r11111uuIIIII11MIIIIu1I] 1. 1I11111111 1I111i ;au1 11 W12A EQ. 9" i1111111I■ 11111111111111111111111111111111111111I111111III IIU11111 1111111111111111111111111111111111111111 1111111111111111111111111 NI MI A105 12'TB a a 0) W12 A105 0 0 NMC 1 11111/111111111111111. 11111111111111111111111111111 11111111111111111111111M 111111111111111111111 )9 LAI gir 1 D EQUIPMENT PLAN 0 FLOOR PLAN 1/8" 1' -0" 25' -4" 1/8" 1' -0" ROOM LEGEND ROOM NO. A101 A102 A103 A104 A105 ROOM NAME KINDERGARTEN CLASSROOM RESTROOM RESTROOM OFFICE ENTRANCE AREA CLNG HT 1406 SF 9' -4" 161 SF 9' -4" 40 SF 9' -4" 76 SF 9' -4" 305 SF 9' -4" VERIFICATION NOTE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CLEARANCES AND ALL EXISTING FIELD CONDITIONS BEFORE STARTING CONSTRUCTION. COMMENCEMENT OF WORK CONSTITUTES ACCEPTANCE OF CONDITIONS. SHOULD DIFFERENT CONDI11ONS BE ENCOUNTERED, CONTACT THE ARCHITECT BEFORE PROCEEDING WITH WORK. EQUIPMENT GENERAL NOTES INDICATES SCHEDULED EDUCATIONAL CASEWORK. SEE A7S SHEETS. ALL COUNTERTOPS TO HAVE CONTINUOUS 4" HIGH BACKSPLASHES AND ENDSPLASHES UNLESS NOTED OTHERWISE. HIDDEN LINES INDICATE ITEMS TO BE PART OF LOOSE EQUIPMENT PACKAGE OR BY OWNER, NOT INCLUDED IN CONSTRUCTION CONTRACTS. DASHED ONES INDICATE OVERHEAD ITEMS (INCLUDED IN CONSTRUCTION CONTRACTS). ALL PROJECTION SCREENS (PS) AND VIDEO FORMAT PROJECTION SCREENS (VFPS) ARE TO BE CEILING MOUNTED AND MANUAL UNLESS NOTED OTHERWISE. -X REFERS TO MOUNTING HEIGHT, SEE SHEET A7. CONTRACTOR TO DETERMINE LOCATIONS AND AMOUNT OF EXTRA DROP REQUIRED ON CEIUNG MOUNTED SCREENS. (PSS) INDICATES PENCIL SHARPENER SUPPORT REFER TO DETAIL X -AX.X. (TB) INDICATES 4' HIGH TACK BOARD LENGTH AS INDICATED. REFER TO MOUNTING HEIGHT DRAWING. (CB) INDICATES 4' HIGH CHALK BOARD LENGTH AS INDICATED. REFER TO MOUNTING HEIGHT DRAWING. (MB) INDICATES 4' HIGH MARKER BOARD LENGTH AS INDICATED. REFER TO MOUNTING HEIGHT DRAWING. PROVIDE FILLER STRIPS BETWEEN CASEWORK UNITS AND WALL OR BETWEEN ANY UNIT AS REQUIRED. EXTEND COUNTER TO FACE OF WALL OR ADJACENT TALL CABINET. ALL CASEWORK DOORS AND DRAWERS SHALL BE LOCKABLE. J. ALL EXPOSED ENDS AND BACKS OF CASEWORK SHALL BE FINISHED. K. CASEWORK INSTALLER SHALL CUT CASEWORK AS REQUIRED FOR PLUMBING /ELECTRICAL UNES. L CASEWORK INSTALLER SHALL CAULK BETWEEN COUNTERS, BACKSPLASHES, AND WALLS. M. ALL WALL MOUNTED CASEWORK SHALL BE MOUNTED WITH THE TOP AT 7 -0" AFF UNLESS OTHERWISE NOTED. N PROVIDE SLOPE TOPS AT ALL WALL CABINETS AND TALL CABINETS, UNLESS OTHERWISE NOTED. SEE DETAIL X -A7.XX EQUIPMENT KEYNOTES 0 (ALL NOTES MAY NOT PERTAIN TO THIS SHEET) 1. CASEWORK FILLERS, AS REQUIRED, EXTEND WORK SURFACE TO FACE OF WALL OR ADJACENT TALL CASEWORK. 2. LOOSE FURNISHINGS BY SEPARATE CONTRACT 3. TOWEL DISPENSER BY OWNER 4. PROJECTION SCREEN MOUNTED TO CEILING REFER TO PROJECT MANUAL 5. SINK, REFER TO PLUMBING SPECIFICATIONS. 6. SEMI RECESSED FIRE EXTINGUISHER, REFER TO DETAIL X -AX.X. 7. FULLY RECESSED FIRE EXTINGUISHER, REFER TO DETAIL X -AX.X. 8. TOWEL DISPENSER BY OWNER. 9. WINDOW BLINDS REFER TO PROJECT MANUAL ARCHITECTURAL PLAN GENERAL NOTES A. ALL CMU WALLS THAT DO NOT LAY OUT IN FULL OR HALF LENGTHS SHOULD BE BALANCED SO AS NOT TO HAVE ANY PIECES LESS THAN 4" IN SIZE EXPOSED TO VIEW. WHERE DISSIMILAR FLOOR MATERIALS MEET, THEY SHALL DO SO UNDER THE CENTERUNE OF THE DOOR, UNLESS NOTED OTHERWISE. THERE SHALL BE PERIMETER INSULATION CONTINUOUS AROUND THE ENTIRE PERIMETER OF THE BUILDING EXTENDING 2' -0" MINIMUM BELOW GRADE. THE BASE FLOOR ELEVATION INDICATED FOR THE PROJECT IS 100' -0 REFER TO SITE PLAN FOR CORRELATION TO USGS DATUM. ALL INTERIOR MASONRY WALLS THAT RUN TO UNDERSIDE OF DECK ABOVE SHALL HAVE A 2" JOINT (U.N.O.) AT THE DECK TO BE FILLED WITH FIRE STOPPING AT RATED WALLS PER PROJECT MANUAL, AND MINERAL WOOL AT THE NON -RATED WALLS, TO ALLOW FOR DEFLECTION. FOR TYPICAL COMMON JOINT DETAILS AND CONSTRUCTION MOVEMENT JOINT DETAILS REFER TO DETAILS ON SHEET A1.2 ALL DIMENSIONS ON FLOOR PLANS ARE TO FINISH FACE OF CMU, CONCRETE, BRICK OR FINISH FACE OF GWB AT METAL STUD WALLS, UNLESS NOTED OTHERWISE. HINGE SIDE DOOR JAMB AT WALLS WILL TYPICALLY BE LOCATED 4" MINIMUM FROM ADJACENT WALL UNLESS NOTED OTHERWISE. ALL EXPOSED CONCRETE MASONRY UNITS (CMU) CORNERS ARE TO BE BULLNOSE, EXCEPT AT WINDOW JAMBS, BULKHEADS, WINDOW AND DOOR HEADS. SEE REFLECTED CEILING PLANS FOR BULKHEAD LOCATIONS AND DETAIL REFERENCES. REFER TO ROOM FINISH SCHEDULE AND EQUIPMENT PLANS FOR LOCATION AND EXTENT OF FINISH FLOOR MATERIALS. PROVIDE WOOD BLOCKING AS REQUIRED. WITHIN METAL STUD WALLS FOR WALL MOUNTED ITEMS. REFER TO MASTER /CODE PLANS FOR CODE INFORMATION, FIRE RATED WALLS, AND NON -RATED WALLS EXTENDING TO THE DECK ABOVE. PROVIDE BATT INSULATION CONTINUOUS AT INTERSECTION OF EXTERIOR WALLS AND DECK. ARCHITECTURAL PLAN NOTES 0 (ALL NOTES MAY NOT BE INDICATED ON THIS SHEET) w? INDICATES WALL TYPE REFER TO DRAWING AX.X FOR WALL THICKNESS, HEIGHT AND COMPOSITION. 1 1" EXPANSION JOINT, SEALANT AND BACKERS ROD TYPICAL 2. ROOF OVERHANG ABOVE REFER TO ROOF PLAN A2.1 3. GYPSUM WALL BOARD (GWB) BULKHEAD ABOVE, REFER TO REFLECTED CEIUNG PLAN A9.1 4. FLOOR MATERIAL TRANSITION CC CC Q co u_ -J zZo W D �N a J W o cc w J CO W J �U 0 C U O Z 0 O F- Z W J J aW Z W a 5 W Z z� O 0- O C 0 0-1 Li- W I co() CC co LL. 0 0 0 00 0 N Z 00 0 0) N W v 0 0 w N 0 V a_ 0 s 0 r H 0 CARMEL ELEMENTARY SCHOOL 208100.00