HomeMy WebLinkAboutPg 4 A1.2 First Floor: Equipment, Doors, Frame ElevationsWALLTYPE SCHEDULE
5/8" GWB (ONE SIDE) ON
3 5/8" STEEL STUDS 0 16" OC
a
00
W11
5/8" GWB (EACH SIDE)
ON 3 5/8" STEEL STUDS
AT 16" OC WITH SOUND
ATTENUATION FULL HEIGHT
W28
WALL TO 4" MINIMUM ABOVE HIGHEST
ADJACENT CEILING.
W #A
ONE LAYER GWB TO DECK ABOVE WITH
SOUND ATTENUATION WHERE APPLICABLE.
WtE
W #H
WINDOW TYPES
F
FLUSH DOOR
DOOR TYPES
DOOR
NUMBER
A101 -A
A101 -B
A103 -A
A104 -A
M 05 -A
DOOR SIZE
SIZE
w
N
0
0
3' -0" x 7' -2"
3' -0" x 7 -2"
3' -0" x 7' -2"
3' -0" x 7' -2"
PR 3' -0" x 7' -2"
STC RATING 45 -49
WALL CONSTRUCTION ABOVE CEILING
SEE WALL CONSTRUCTION
BELOW CEIUNG FOR WALL
CONSTRUCTION
EXTEND (1) LAYER GWB
SIDE) TO DECK /STRUCTURE
CMU TO STRUCTURE ABOVE, GWB TO 4"
ABOVE FINISH CEIUNG. CMU BOND BEAM
LAST FULL COURSE
9 -2
DOOR
MAT.
WD
AL
WD
WD
AL
z =M
al MI
twol
SEE WALL CONSTRUCTION
BELOW CEILING FOR WALL
CONSTRUCTION
t
a
a
00
WI FRONT WI SIDE
TYPE
N
FGAL2
F
F
FGAL2
EQ.
FI F2
DOOR FRAMETYPES
MAT.
HM
AL
HM
HM
AL
NARROW UTE
DOOR
TYPE
F1
F1
F1
F1
SIZE
5/8" GWB (EACH SIDE) ON
3 5/8" STEEL STUDS 0 16" OC
W12
4" FACEBRICK
W48
i 2' 0" t
EQ.
w
N
8
JAMB DEPTH
6"
4 1/2"
6"
6"
4 1/2"
FINISH CEILING -SEE
REFLECTED CEILING PLANS
CMU BOND BEAM
FRAME
HEAD
10/A1.4
13/A1.4
10/A1.4
10/A1.4
WALL CONSTRUCTION BELOW CEILING
STEEL STUD BRACING
(4' -0" OC MAX)
SOUND /ACOUSTICAL INSULATION
FULL HEIGHT (IF APPLICABLE)
I===
-FINISH CEILING SEE
REFLECTED CEIUNG PLAN
a
N
a
00
HOLD TOP OF CMU 2" FROM
BOTTOM OF DECK /STRUCTURE.
CUT CMU, WHERE APPLICABLE,
TO ACCOMMODATE 2" DIMENSION.
PACK 2" VOID W/ MINERAL
WOOL (0 NON- RATED) AND
FIRESTOPPING (0 RATED)
DETAILS
JAMB
11/A1.4
14/A1.4
11/A1.4
11/A1.4
a
CV
t
FULL GLASS 2
SILL
12/A1.4
STC RATING 40 -44
\I\
STC RATING 41
STEEL STUD BRACING
(4' -0" OC MAX)
FIRE
RATING
IN
MINS.
4' -0"
t
W2
HARDWARE
KEYSIDE
SET ROOM
NO. NO.
GENERAL NOTES
W1A 1. WALL TYPE AS SHOWN: "1" REFERS TO WALL
CONSTITJCTION BELOW CEILING "A" REFERS TO WALL
CONSTRUCTION ABOVE CEILING.
2. REFER TO CODE PLANS FOR RATED AND NON -RATED
WALLS EXTENDING TO DECK.
3. REFER TO ROOM FINISH SCHEDULE SCHEDULE FOR
WALL FINISHES
4. REFER TO STRUCTURAL DRAWINGS FOR HORIZONTAL
AND VERTICAL REINFORCING 0 MASONRY WALLS
5. PROVIDE DEEP LEG TRACK 0 ALL STEEL STUDS THAT
EXTEND TO DECK /STRUCTURE ABOVE (UNO) PACK VOIDS
0 NON -RATED WALLS W/ MINERAL WOOL
PACK VOIDS 0 RATED WALLS W/ FIRESTOPPING PROVIDE
SOUND INSULATION 0 NON -RATED WALLS THAT
REQUIRE SOUND
ATTENUATION. REFER TO CODE PLANS FOR WALL RATING.
PROVIDE ACOUSTICAL INSULATION 0 RATED WALLS THAT
REQUIRE SOUND ATTENUATION. REFER TO CODE PLANS FOR
WALL RATING.
SCALE 1/4" 1' -0"
SCALE 1/4" 1' -0"
DOOR AND FRAME SCHEDULE
7/8" STEEL FURRING AND 5/8" GWB
ON EXTERIOR WALL (SEE WALL
SECTIONS)
W18
a
00
1'
REMARKS
SEE SECTION 080050
6' -0"
W3
SCALE 1/4" 1' -0"
1. THE BOTTOM OF GLASS UTES FOR ALL
DOORS, EXCEPT FULL GLASS DOORS(I.E. FG,
N2), MUST BE AT A MINIMUM OF 43" ABOVE
FINISHED FLOOR TO ALLOW FOR EXIT DEVICE
MOUNTING. THIS LOCATION WILL EUMINATE
GLASS AND EXIT DEVICE INTERFERENCE. IT
WILL ALSO ELIMINATE THE USE OF EXIT
DEVICE SHIM KITS TO RAISE THE DEVICE OVER
THE GLASS BEAD.
2. THE TOP DOOR RAIL DIMENSIONS, AS
SHOWN ON THE DOOR TYPES, ARE REQUIRED
FOR MOUNTING CLOSERS WITHOUT THE USE
OF A DROP PLATE. THESE DIMENSIONS WILL
ALSO PREVENT THE CLOSERS FROM BEING
SEEN THROUGH THE GLASS ON THE OUTSIDE.
3. THE BOTTOM DOOR RAIL HEIGHT
DIMENSION SHALL BE 10" TO CONFORM WITH
VARIOUS STATE ADA BARRIER -FREE CODES.
4. THE STANDARD MOUNTING HEIGHT FOR
EXIT DEVICES IS 40" TO CENTERUNE ABOVE
FINISHED FLOOR.
5. GLASS UTE SIZE, AREA, AND
LOCK -TO -CITE CUT -OUTS, AS SHOWN ON
DOOR TYPES, CONFORM WITH MANUFACTURER'S
LIFETIME WARRANTY AND FIRE RATED
REQUIREMENTS.
6. FIRE RATING IN MINUTES
20 20 MINUTES GLASS ALLOWED IN
DOOR -1296 SQ. INCHES
45 C LABEL 3/4 HOUR GLASS ALLOWED
IN DOOR -1296 SQ. INCHES
60 B LABEL 1 HOUR GLASS ALLOWED IN
DOOR -100 SQ. INCHES
90 B LABEL 1-1/2 HOUR GLASS
ALLOWED IN DOOR -100 SQ. INCHES
180 A LABEL 3 HOUR GLASS ALLOWED IN
DOOR -NONE
1111111111 111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111
1111111111111111111 I
BO1B
7
,IIIII111111111IIIIII 1111111" r11111uuIIIII11MIIIIu1I] 1. 1I11111111 1I111i ;au1
11
W12A
EQ.
9"
i1111111I■ 11111111111111111111111111111111111111I111111III IIU11111 1111111111111111111111111111111111111111 1111111111111111111111111
NI MI
A105
12'TB
a
a
0)
W12
A105 0
0
NMC
1 11111/111111111111111. 11111111111111111111111111111 11111111111111111111111M 111111111111111111111
)9 LAI
gir 1 D
EQUIPMENT PLAN
0
FLOOR PLAN
1/8" 1' -0"
25' -4"
1/8" 1' -0"
ROOM LEGEND
ROOM
NO.
A101
A102
A103
A104
A105
ROOM NAME
KINDERGARTEN
CLASSROOM
RESTROOM
RESTROOM
OFFICE
ENTRANCE
AREA CLNG HT
1406 SF 9' -4"
161 SF 9' -4"
40 SF 9' -4"
76 SF 9' -4"
305 SF 9' -4"
VERIFICATION NOTE
CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND
CLEARANCES AND ALL EXISTING FIELD CONDITIONS
BEFORE STARTING CONSTRUCTION. COMMENCEMENT
OF WORK CONSTITUTES ACCEPTANCE OF CONDITIONS.
SHOULD DIFFERENT CONDI11ONS BE ENCOUNTERED,
CONTACT THE ARCHITECT BEFORE PROCEEDING WITH
WORK.
EQUIPMENT GENERAL NOTES
INDICATES SCHEDULED EDUCATIONAL
CASEWORK. SEE A7S SHEETS.
ALL COUNTERTOPS TO HAVE CONTINUOUS 4"
HIGH BACKSPLASHES AND ENDSPLASHES UNLESS
NOTED OTHERWISE.
HIDDEN LINES INDICATE ITEMS
TO BE PART OF LOOSE EQUIPMENT PACKAGE OR
BY OWNER, NOT INCLUDED IN CONSTRUCTION
CONTRACTS. DASHED ONES
INDICATE OVERHEAD ITEMS (INCLUDED IN
CONSTRUCTION CONTRACTS).
ALL PROJECTION SCREENS (PS) AND VIDEO
FORMAT PROJECTION SCREENS (VFPS) ARE TO
BE CEILING MOUNTED AND MANUAL UNLESS
NOTED OTHERWISE. -X REFERS TO MOUNTING
HEIGHT, SEE SHEET A7. CONTRACTOR TO
DETERMINE LOCATIONS AND AMOUNT OF EXTRA
DROP REQUIRED ON CEIUNG MOUNTED
SCREENS.
(PSS) INDICATES PENCIL SHARPENER SUPPORT
REFER TO DETAIL X -AX.X.
(TB) INDICATES 4' HIGH TACK BOARD LENGTH
AS INDICATED. REFER TO MOUNTING HEIGHT
DRAWING.
(CB) INDICATES 4' HIGH CHALK BOARD LENGTH
AS INDICATED. REFER TO MOUNTING HEIGHT
DRAWING.
(MB) INDICATES 4' HIGH MARKER BOARD LENGTH
AS INDICATED. REFER TO MOUNTING HEIGHT
DRAWING.
PROVIDE FILLER STRIPS BETWEEN CASEWORK
UNITS AND WALL OR BETWEEN ANY UNIT AS
REQUIRED. EXTEND COUNTER TO FACE OF WALL
OR ADJACENT TALL CABINET.
ALL CASEWORK DOORS AND DRAWERS SHALL BE
LOCKABLE.
J. ALL EXPOSED ENDS AND BACKS OF CASEWORK
SHALL BE FINISHED.
K. CASEWORK INSTALLER SHALL CUT CASEWORK AS
REQUIRED FOR PLUMBING /ELECTRICAL UNES.
L CASEWORK INSTALLER SHALL CAULK BETWEEN
COUNTERS, BACKSPLASHES, AND WALLS.
M. ALL WALL MOUNTED CASEWORK SHALL BE
MOUNTED WITH THE TOP AT 7 -0" AFF UNLESS
OTHERWISE NOTED.
N PROVIDE SLOPE TOPS AT ALL WALL CABINETS
AND TALL CABINETS, UNLESS OTHERWISE NOTED.
SEE DETAIL X -A7.XX
EQUIPMENT KEYNOTES 0
(ALL NOTES MAY NOT PERTAIN TO THIS SHEET)
1. CASEWORK FILLERS, AS REQUIRED, EXTEND
WORK SURFACE TO FACE OF WALL OR
ADJACENT TALL CASEWORK.
2. LOOSE FURNISHINGS BY SEPARATE CONTRACT
3. TOWEL DISPENSER BY OWNER
4. PROJECTION SCREEN MOUNTED TO CEILING
REFER TO PROJECT MANUAL
5. SINK, REFER TO PLUMBING SPECIFICATIONS.
6. SEMI RECESSED FIRE EXTINGUISHER, REFER TO
DETAIL X -AX.X.
7. FULLY RECESSED FIRE EXTINGUISHER, REFER
TO DETAIL X -AX.X.
8. TOWEL DISPENSER BY OWNER.
9. WINDOW BLINDS REFER TO PROJECT MANUAL
ARCHITECTURAL PLAN GENERAL NOTES
A. ALL CMU WALLS THAT DO NOT LAY OUT IN
FULL OR HALF LENGTHS SHOULD BE BALANCED
SO AS NOT TO HAVE ANY PIECES LESS THAN
4" IN SIZE EXPOSED TO VIEW.
WHERE DISSIMILAR FLOOR MATERIALS MEET,
THEY SHALL DO SO UNDER THE CENTERUNE OF
THE DOOR, UNLESS NOTED OTHERWISE.
THERE SHALL BE PERIMETER INSULATION
CONTINUOUS AROUND THE ENTIRE PERIMETER
OF THE BUILDING EXTENDING 2' -0" MINIMUM
BELOW GRADE.
THE BASE FLOOR ELEVATION INDICATED FOR
THE PROJECT IS 100' -0 REFER TO SITE PLAN
FOR CORRELATION TO USGS DATUM.
ALL INTERIOR MASONRY WALLS THAT RUN TO
UNDERSIDE OF DECK ABOVE SHALL HAVE A 2"
JOINT (U.N.O.) AT THE DECK TO BE FILLED
WITH FIRE STOPPING AT RATED WALLS PER
PROJECT MANUAL, AND MINERAL WOOL AT THE
NON -RATED WALLS, TO ALLOW FOR DEFLECTION.
FOR TYPICAL COMMON JOINT DETAILS AND
CONSTRUCTION MOVEMENT JOINT DETAILS REFER
TO DETAILS ON SHEET A1.2
ALL DIMENSIONS ON FLOOR PLANS ARE TO
FINISH FACE OF CMU, CONCRETE, BRICK OR
FINISH FACE OF GWB AT METAL STUD WALLS,
UNLESS NOTED OTHERWISE.
HINGE SIDE DOOR JAMB AT WALLS WILL
TYPICALLY BE LOCATED 4" MINIMUM FROM
ADJACENT WALL UNLESS NOTED OTHERWISE.
ALL EXPOSED CONCRETE MASONRY UNITS (CMU)
CORNERS ARE TO BE BULLNOSE, EXCEPT AT
WINDOW JAMBS, BULKHEADS, WINDOW AND
DOOR HEADS.
SEE REFLECTED CEILING PLANS FOR BULKHEAD
LOCATIONS AND DETAIL REFERENCES.
REFER TO ROOM FINISH SCHEDULE AND
EQUIPMENT PLANS FOR LOCATION AND EXTENT
OF FINISH FLOOR MATERIALS.
PROVIDE WOOD BLOCKING AS REQUIRED. WITHIN
METAL STUD WALLS FOR WALL MOUNTED ITEMS.
REFER TO MASTER /CODE PLANS FOR CODE
INFORMATION, FIRE RATED WALLS, AND
NON -RATED WALLS EXTENDING TO THE DECK
ABOVE.
PROVIDE BATT INSULATION CONTINUOUS AT
INTERSECTION OF EXTERIOR WALLS AND DECK.
ARCHITECTURAL PLAN NOTES 0
(ALL NOTES MAY NOT BE INDICATED ON THIS SHEET)
w? INDICATES WALL TYPE REFER TO DRAWING AX.X
FOR WALL THICKNESS, HEIGHT AND
COMPOSITION.
1 1" EXPANSION JOINT, SEALANT AND BACKERS
ROD TYPICAL
2. ROOF OVERHANG ABOVE REFER TO ROOF PLAN
A2.1
3. GYPSUM WALL BOARD (GWB) BULKHEAD ABOVE,
REFER TO REFLECTED CEIUNG PLAN A9.1
4. FLOOR MATERIAL TRANSITION
CC
CC Q co
u_ -J
zZo
W
D �N
a
J
W
o
cc
w
J
CO W
J �U
0 C
U
O Z
0 O
F-
Z
W
J J
aW
Z W
a
5
W Z
z�
O
0- O
C 0
0-1
Li-
W
I
co()
CC co
LL.
0
0
0
00
0
N
Z
00
0
0)
N
W
v 0
0
w
N
0
V
a_
0
s
0
r
H
0
CARMEL ELEMENTARY SCHOOL
208100.00