Loading...
HomeMy WebLinkAboutPg 5 Exterior ElevationsREMOVE EXISTING COPING FASCIA, REFER TO DETAIL SECTIONS 4" EXPANSION JOINT EXISTING COPING AND FASCIA TO REMAIN 5 O OFD 2" O RD ALUMINUM COPING TO MATCH EXISTING PROFILE AND COLOR 3 REMOVE EXISTING COPING FASCIA, REFER TO DETAIL SECTIONS 6.5" 0 39 -0" EXISTING COPING AND FASCIA TO REMAIN 14' -0" MOR ALUMINUM STOREFRONT TO MATCH EXISTING ROOF PLAN ALUMINUM FASCIA TO MATCH EXISTING PROFILE AND COLOR O RD —ALUMINUM WINDOW ALUMINUM COPING TO MATCH EXISTING PROFILE AND COLOR BRICK TO MATCH EXISTING WEST ELEVATION EXISTING BRICK TO REMAIN EXISTING DOOR TO REMAIN A1.5 4 ALUMINUM COPING TO MATCH EXISTING PROFILE AND COLOR ALUMINUM FASCIA TO MATCH EXISTING PROFILE AND COLOR ALUM. WINDOWS BRICK TO MATCH EXISTING ALUMINUM STOR ALUMINUM STOREFRONT TO MATCH EXISTING TO MATCH EXISTING ALUMINUM COPING TO MATCH EXISTING PROFILE AND COLOR EXISTING BRICK TO REMAIN 1 TO MATCH EXISTING PROFILE AND COLOR EFRONT CI ALUMINUM WINDOWS TO MATCH EXISTING PROFILE AND COLOR 1) 4. BRICK TO MATCH EXISTING B J ALUMINUM COPING 2 3 ALUMINUM WINDOW ALUMINUM FASCIA ALUMINUM FASCIA TO MATCH EXISTING PROFILE AND COLOR ALUMINUM STOREFRONT TO MATCH EXISTING ALUMINUM FASCIA TO MATCH EXISTING PROFILE AND COLOR BRICK TO MATCH EXISTING EXISTING A1.5 PLASTER ALUMINUM SILL NORTH ELEVATION EAST ELEVATION A1.5 ALUM. WINOWS SOUTH ELEVATION RICK TO REMAIN BRICK TO MATCH EXISTING EAST ELEVATION ALUMINUM COPING TO MATCH EXISTING PROFILE AND COLOR ALUMINUM WINDOW ROOF PLAN GENERAL NOTES A. ALL DETAILS SHOWN ARE FOR GENERAL INFORMATION. ALL FINAL FLASHING CONDMONS SHALL BE THE RESPONSIBILITY OF THE ROOF INSTALLER, AND SHALL MEET APPROVAL OF ROOF MANUFACTURER. B ALL DETAIL MODIFICATIONS MUST HAVE SHOP DRAWINGS APPROVAL CONTRACTOR SHALL INSPECT AND VERIFY ALL EXISTING FIELD CONDITIONS, CLEARANCES, AND DIMENSIONS BEFORE STARTING CONSTRUCTION. COMMENCEMENT OF WORK CONSTITUTES ACCEPTANCE OF EXISTING CONDITIONS. SHOULD DIFFERENT CONDITIONS BE ENCOUNTERED, CONTACT ARCHITECT BEFORE PROCEEDING WITH ANY FURTHER WORK. C OPENINGS IN ROOF WILL BE CUT BY ROOF CONTRACTOR. MECHANICAL CONTRACTOR TO COORDINATE LOCATION OF OPENING IN ROOF WITH ROOF CONTRACTOR. CURB TO BE PROVIDED BY MECHANICAL CONTRACTOR AND INSTALLED BY ROOF CONTRACTOR. D PROVIDE FLASHING AND SADDLES FOR ALL EQUIPMENT PROVIDED UNDER MECHANICAL E SADDLES AND TAPERED INSULATION SYMBOLS INDICATE DESIGN INTENT TO SLOPE TO DRAIN. CONTRACTOR SHALL PROVIDE SUBMITTAL DRAWIINGS FOR TAPERED INSULATION AND SADDLES TO INSURE POSITIVE SLOPE. F THE ROOF CONTRACTOR SHALL PROTECT ALL ROOF DRAINS, SCUPPERS, AND DOWNSPOUTS FROM DEBRIS CREATED DURING DEMOLITION AND CONSTRUCTION. THE ROOF CONTRACTOR SHALL INSPECT AND CLEAR ALL DRAINS, SCUPPERS, AND DOWNSPOUTS PRIOR TO COMPLETION OF WORK AND TO ENSURE THAT THEY ARE FREE OF DEBRIS AND ARE FUNCTIONING PROPERLY. ROOF PLAN SYMBOL LEGEND O RD INDICATES ROOF DRAIN SUMP PAN. (FLASH IN ACCORDANCE WITH ROOF MEMBRANE MANUFACTURER'S RECOMMENDATION.) REFER TO DETAILS X —AX.X. INDICATES ROOF OVERFLOW DRAIN. (FLASH IN ACCORDANCE WITH ROOF MEMBRANE MANUFACTURER'S RECOMMENDATION.) REFER TO DETAILS X —AX.X. INDICATES VENT STACK REFER TO DETAILS X —AX.X. INDICATES EXHAUST FAN REFER TO DETAILS X —AX.X. SLOPE 1/12p INDICATES ROOF SLOPE INDICATES ROOF SADDLE REFER TO PROJECT MANUAL INDICATES WALL UNE BELOW REFER TO ARCHITECTURAL FLOOR PLANS. VERIFICATION NOTE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CLEARANCES AND ALL EXISTING FIELD CONDITIONS BEFORE STARTING CONSTRUCTION. COMMENCEMENT OF WORK CONSTITUTES ACCEPTANCE OF CONDITIONS. SHOULD DIFFERENT CONDITIONS BE ENCOUNTERED, CONTACT THE ARCHITECT BEFORE PROCEEDING WITH WORK. o a co s W 0 z I m 0 0 1— a 0 0 1— W J w CC CC w 1— w w cc U x z 8 0 0 0 0 co N rn N o y z W 0< a in (1) 0 3 O V 0 s 0 03 00 M W 1- 0 M T CARMEL ELEMENTARY SCHOOL 208100.00