HomeMy WebLinkAbout03080001 Construction Plans for Ballantrae pg. 1SHEET
NO.
DESCRIPTION
1
TITLE SHEET
2
EXISTING CONDITIONS /DEMOLITION PLAN
3
SITE DEVELOPMENT PLAN
4
SITE EROSION CONTROL PLAN
5
EROSION CONTROL DETAILS
6
LANDSCAPE PLAN AND DETAILS
7
TREE PRESERVATION PLAN
8
STREET PLAN AND PROFILE
9
SANITARY PLAN AND PROFILE
10
S'ORM PLAN AND PROFILE
11
TRAFFIC MAINTENANCE, ENTRANCE AND CUL -DE -SAC DETAILS
12
WATER DISTRIBUTION PLAN
13
SITE DETAILS
14
HAMILTON COUNTY HIGHWAY DEPT. DETAILS
SHEET
NO
DESCRIPTION
DATE
1,3,11,13
REV PER HAMILTON CO. HIGHWAY DEPT.
5/12/03
1,3,13
REV PER CTE ENGINEERS
5/20/03
ALL
REV PER HAMILTON CO. SURVEYORS OFFICE
5/20/03
ALL
REV LAKE, ADD RETAINING WALLS
6/18/03
ALL
I
REV WATER LOCATION, ADDITIONAL HYDRANTS
6/25/03
1,3,4,6,9,10
REV PER HAMILTON CO. SURVEYORS OFFICE
7/9/03
3,4,6
REV PER YARD SWALE 8c S.S.D. PER S. 3REWER
7/22/03
3,11,13
HAMILTON COUNTY HIGHWAY REVISION
PER LETTER 7/30/03
8/4/03
1 0
TYPICAL SANITARY SEWER SPECIFICATIONS
TO BE USED FOR PRIVATE SEWER DEVELOPMENT
WITHIN
CLAY TOWNSHIP REGIONAL WASTE DISTRICT
REVISED MAY 2002
1. Standard specifications of the District and Indiana Department of Transportotion shall apply
for all work and materials. Pipe sholl be installed in accordance with Section 715.
2. Sanitary sewer pipe shall be PVC in accordance with ASTM D -3034 (S.D.R. 35) and ASTM
2321. PVC pipe shop hove grooved bell and gasket. The pipe shall be mode of PVC plastic
having a cell classification of 12454B.
3. PVC sewer fittings shall conform to the requirements of ASTM 0- 3034 -89 specification.
Fittings in sizes through 8` shall be molded in one piece with elnstomeric joints and
minimum socket depths as specified in sections 6.2 and 7.3.2. Fittings 10 and larger shall
be molded or fabricated in accordonce with section 7.11 with manufacturers standard pipe
bells and gaskets. Wall thickness of fittings shall be SDR 26 as defined in section 7.4.1 of
specifications. Gaskets for elostomeric joints shall be molded with a minimum cross sectional
area of 0.20 square inches and conform to ASTM F -477 specification. Fittings
shall be manufactured by Harco or equal.
4. All sanitary manholes shall be precast concrete manholes in accordance with ASTM C -478
and Section 720. 0 -rings shall conform to C -443. Kent Seal or equivalent shall also be
applied to all joints and between riser rings and castings. Monhole step spacing shall be no
more than 16- inches. Manholes shall be air tested for leakage in accordance with ASTM
C1244 -93, Standard Test Method for Concrete Sewer Manholes by the Negative Air
Pressure (Vacuum) Test.
A. Installation and operation of vacuum equipment and indicating devices must be in
accordance with manufacturers recommendations and performance specifications
which have been provided by the manufacturer and accepted by the Engineer. The
vacuum equipment must be capable of testing the entire manhole, including the
costing and riser rings.
B. With the vacuum tester set in place:
1. Connect the vacuum pump to the outlet port with the valve open.
2. Draw a vacuum of ten (10) inches of Hg. and close the valve.
C. Accepted standards for leakage will be established from the elapsed time for a
negative pressure change from ten (10) inches to nine (9) inches of mercury. The
maximum allowable leokoge rote for a four (4) foot diameter manhole must be in
accordance with the following:
Minimum Elapsed Time for a
Manhole Depth Pressure Change of 1 Inch Hg
10 feet or less 60 seconds
>10 feet but <15 feet 75 seconds
>15 feet but <25 feet 90 seconds
For manholes five (5) feet in diameter, add on additional fifteen (15) seconds and for
manholes six (6) feet in diameter, odd an additional thirty (30) seconds to the time
requirements for four (4) foot diameter manholes. For all manholes deeper than
twenty -five (25) feet, the Engineer will determine the applicable minimum elapsed
time.
D. If the manhole fails the test, necessary repairs must be made and the vacuum test and
repairs must be repeated until the manhole posses the test.
E. If manhole joint sealants ore pulled out during the vacuum test, the manhole must be
disassembled and the joint sealants replaced.
F. Manholes will be subject to visual inspection with all visual leaks being repaired.
5. Butyl rubber coating shall be applied around each manhole joint from 6- inches above to 6-
inches below each joint. The appropriate primer shall be applied prior to applying the rubber
coating. Inside joints to be filled with precoot plug material.
6. The manhole chimneys, including all riser rings shall be sealed using Infi- Shield Uniband
or approved equal. Prior to plocement, the top 4- inches of the manhole cone and casting
frame shall be cleaned and primed. The Uniband shop extend from 3- inches below the top
of the cone section to 2- inches over the flange of the manhole casting frame.
7. The costing elevations are set by plan. However, the castings ore to be adjusted in the field
by the Engineers representative should a discrepancy occur between plan grade and existing
grade. New manhole ring and cover shall be installed to establish grade. Maximum height
of adjusting rings shall be 12- inches.
8. Backfill around all structures and all cuts under paved areas with granular material.
Trenches opening within 5 -feet of paved roadways shall be backfilled with granular material
in accordance with Section 211. Backfill under sidewalks shall be granular, unless the walks
are constructed a minimum of 6 months after backfill has been in place.
9. The Contractor shall be responsible for verifying that all state highways, city, and county
permits have been obtained by the developer prior to start of construction.
10. The Contractor shall be required to furnish the developer s Engineer with a set of prints,
marked in red pencil, showing actual sewer location and invert, to include lateral location,
depth and length. Such asbuilt prints must be received by the Engineer before the final
contract payment can be authorized. The sanitary sewer laterals and stubs termination shall
be indicated on the surface with a metal fence post set immediately above the said
termination point.
11. All sanitary sewer lines upon completion will be required to pass a low pressure air test.
Said test sholl be conducted according to ASTM 1417 -92, and shall be witnessed by an
Engineer and a representative of the District. The testing shall be in accordance with Toble
1. Add 0.5 psig for each foot of water above the sewer line (being tested.
12. Deflection tests shall be performed on all flexible* pipe after the final backfill has been in
place at least 30 days. No pipe shall exceed a vertical deflection of 5X deflection test
results. *The following are considered non flexible pipes: concrete pipe, ductile iron pipe,
and cast iron pipe). The deflection test shall be performed with a nine -point mandrel.
Proving rings shall be available.
13. All mandrel testing shall be observed by a professional engineer representative for
certification and a representative of the District.
14. The ends of laterals are to be plugged tight with a braced plastic disc or cap capable of
withstanding a low pressure air test without leakage.
15. Bedding for flexible pipe shall be No. 8 crushed stone from 6- inches below the pipe to 12-
inches above the pipe. Bedding for rigid pipe shall be No. 8 crushed stone from 6- inches
below the pipe to the spring line of the pipe and from this point to 12- inches above shall be
fill sand or equivalent. Manholes shall be ploced on no less thon 6- inches of No. 8 crushed
stone bedding.
16. Water and sewer line crossings and separations shall be in accordance with 327 IAC 3 -6 -9.
17. Trench sholl be opened sufficiently ahead of pipe laying to reveal obstruction, and shall be
properly protected and /or barricaded when left unattended.
18. No water shall be permitted to flow into the sanitary sewer system during construction.
Contractor shall utilize a pump to keep the water level below the pipe. Pump discharge shall
be directed to a storm outlet in accordance with state and federal laws and regulations (327
LAC 3- 6 -20). Any pipe entering existing sewers shall be plugged with screw type
mechanical, braced plug until such time as all tests on the sewers have been completed and
the lines have passed all punch lists.
19. AJI sewer laterals installed by the mainline Contractor shall be bedded the some as the main
line sewer.
20. Forty -eight (48) hours notice shall be given to the District prior to the stort of sewer
construction. Also, 48 hours notice shall be given prior to doing any testing on the sewer.
21. Manhole castings shall be stomped SANITARY SEWER (Neenah Casting R 1642A or
equal) and be self sealing type. The casting flange shall be 34 inches and the clear opening
sholl be 24 inches. Woterproof castings shall be Neenah R- 1916 -F1 and stamped
SANITARY SEWER.
22. The minimum slope for sewer acceptance by the Cloy Township Regional Waste District are:
Size of Pipe Minimum Constructed Slope
8 -inch 0.40%
10 -inch 0.28%
12 -inch 0.22%
15 -inch 0.15%
18 -inch 0.12%
23. The Contractor shall provide measurements of the slope of the sewer for each manhole
section os construction progresses. Such measurements shall be certified by a Registered
Land Surveyor or Engineer and be available on -site for observation by the District s
Inspector. No more than three manhole sections con be constructed in advance of such
measurements.
24. In the event the Contractor does not meet the minimum slopes, the sewer section and any
other affected sewer sections shall be reconstructed to meet such minimum slopes.
25. Laterals are to be troced with a minimum size of 14 gauge wire from the wye to the termin
The contractor for the building or home will extend the wire from this terminus to the
building cleanout adjacent to the building.
OPERATING AUTHORITIES.
INDIANA GAS COMPANY
POST OFFICE BOX 1700
NOBLESVILLE IN 46060
TELEPHONE: (317) 776 -5597
OFFICE OF FIRE CHIEF
2 CIVIC SQUARE
INDIANAPOLIS, INDIANA 46220
TELEPHONE: (317) 571 -2600
CARMEL POLICE DEPARTMENT
3 CIVIC SQUARE
'CARMEL, IN 46032
TELEPHONE: (317) 571 -2500
HAMILTON CO. SHERIFF DEPARTMENT
18100 CUMBERLAND ROAD
INDIANAPOLIS, IN 46206 -1595
TELEPHONE: (317) 773 -1872
CARMEL COMMUNICATIONS DEPARTMENT
31 FIRST AVE. N.W.
CARMEL, IN 46032
TELEPHONE: (317) 571 -2580
10
CLAY TOWNSHIP REGIONAL WASTE
POST OFFICE BOX 40638
INDIANAPOLIS, IN 46240
TELEPHONE: (317) 844 -9200
CARMEL /CLAY SCHOOLS
5201 EAST 131ST STREET
CARMEL, IN 46032
TELEPHONE: (317) 844 -9961
OFFICE OF CITY ENGINEER
1 CIVIC SQUARE
CARMEL, IN 46032
TELEPHONE: (317) 571 -2414
INDIANAPOLIS POWER LIGHT
POST OFFICE BOX 1595
INDIANAPOLIS, IN 46206 -1 595
TELEPHONE: (317) 261 -8222
CARMEL CLAY PARKS Sc RECREATION
1 CIVIC SQUARE
CARMEL, IN 46032
TELEPHONE: (317) 848 -7275
9
us.
CITY OF CARMEL UTILITY
PIPE INSTALLATION
All work shall be in the best practices of the water utility industry and the American Water
Works Association, and in accordance with all applicable Federal, State, and local codes and
regulations.
Furthermore:
1) Any damage done to the City of Carmel Utility's system by the Contractor /Developer of his
affiliates shall immediately be repaired, to the satisfaction and direction of the City of Carmel
Utility by the Contractor /Developer at his own expense.
2) Should the Contractor /Developer propose to depart from the specifications contained herein,
he 'shall submit samples and /or specifications of such alternatives to the City of Carmel Utility
before proceeding.
3) No work shall be performed under conditions which in the opinion of the City of Carmel
Utilities would adversely affect the quality of the finished job.
4) The Contractor /Developer shall conduct his work so cis not to interfere with the present
operation of the existing City of Carmel Utility's water /sanitary sewer system. If any work
interference is encountered between the City of Carmel Utility and the Contractor /Developer, the
City of Carmel Utility will receive priority in scheduling.
CITY OF CARMEL WATER UTILITY
Developer Installed Water Mains
1) Contractors shall call City of Carmel Utility for an on -site pre construction meeting before
work begins. Contractor must have approved plans on -site and all materials to be used must
be approved by a City of Carmel Utility inspector.
2) Contractor will allow inspection by City of Carmel Utility inspectors during the construction
of the water main extension and will honor the City of Carmel Utility's request for field changes
in main extensions related to location, workmanship and materials as they relate to City of
Carmel Utility standards and specifications.
3) The Contractor will have water main extensions pressure tested per City of Carmel Utility
specifications and witnessed by City of Carmel Utility's inspector.
4) The Contractor will conduct the disinfection of water main extension, with direct supervision
by a City of Carmel Utility Operator.
5) Only after the water main extension passes the City of Carmel Utility's laboratory testing,
and two (2) sets of AS -BUILT plans have been turned in to the City of Carmel Utility, will the
water be turned on by the City of Carmel Utility.
CITY OF CARMEL UTILITY STANDARDS
NOTES:
1) Absolutely no Kennedy Fire Hydrants or Valves are allowed.
2) Only Tyler Valve Boxes are allowed.
3) Ductile Iron Pipe in lengths of 20 feet is the only length allowed.
HAMILTON COUNTY SURVEYOR
ONE HAMILTON COUNTY SQUARE, SUITE 146
NOBLESVILLE IN 46060
TELEPHONE: (317) 776 -8495
HAMILTON COUNTY SOIL WATER CONSERVATION DISTRICT
925 DIVISION STREET, ROOM 301
NOBLESVILLE IN 46060
TELEPHONE: (317) 773 -1432
HAMILTON COUNTY HIGHWAY DEPARTMENT
1717 PLEASANT STREET
NOBLESVILLE IN 46060
TELEPHONE: (317) 773 -7770
CITY OF CARMEL
WATER 'UTILITIES
130 FIRST AVENUE S.W.
CARMEL, IN 46032
TELEPHONE: (317) 571 -2648
CONSTRUCTION PLANS FOR
SALLANTRAE
146TH STREET, WEST OF SPRINGMILL ROAD
CARMEL, INDIANA
BENCH
8
V
AR
ed.
Call 1- 800 --382 -5544
2 WORKING DAYS
BEFORE YOU DIG.
"IT'S T
INDIANA STATE DEPARTMENT OF TRANSPORTATION
STANDARD SPECIFICATIONS LATEST EDITION TO BE
USED WITH THESE PLANS,
I \FOR
INDIANA UNDERGROUND
V
ATI O N
PROTECTION SERVICE, INC.
TBM #1: TOP OF CASTING OF SANITARY SEWER MANHOLE ON WEST SIDE
OF WARNER TRAIL ON NORTH SIDE OF 146TH STREET (ENTRANCE TO
MERRIMAC SUBDIVISION)
ELEVATION: 898.88
7
PLANS PREPARED FOR:
ANDERSON CORPORATION
72900 NORTH MERIDIAN STREET
SUITE 380
CARMEL, INDIANA 96032
TELEPHONE: (377) 898 -5000
FAX: (377) 848-5001
CONTACT PERSON: JIM ANDERSON
146th STREET
LAW
AREA MAP
*PROJECT LOCATION
GENERAL NOTES:
1. All storm sewers shall be constructed with reinforced concrete pipe Class 111
or as noted and conform to A.S.T.M. C -76 or latest revision. All manholes
shall be precast concrete construction in accordance with State of Indiana
Specifications and shall have Type "A" cast iron ring and cover.
2. Joints in sewer pipe shall conform to A.S.T.M. Specification C -425 or latest
revision.
3. Sewer pipe shall be bedded in accordance with detail shown. Sewer trenches
shall be kept free of all water. Do not allow water or mud to enter the
sewer.
4. All pipe or drainage structures in trenches under paved surfaces and within 10
feet of the pavement shall be backfilled with granular material and compacted
by approved methods.
5. No roof drains, footing drains and or surface water drains may be connected
to the sanitary sewer system, including temporary connections during
construction.
6. Sewers crossing mains shall be laid to provide minimum distance of 18 inches
between the outside of the water main and the outside of the sewer. This shall
be the case where the water main is either above or below the sewer. The
crossing shall be arranged so that the sewer Joints will be equidistant and as
for as possible from the water main joints. Where a water main crosses under
a sewer, adequote structural support shall be provided for the sewer to
prevent damage to the water main. When it is impossible to obtain proper
horizontal and vertical separation as stipulated above, the sewer shall be
designed and constructed equal to water pipe and shall be pressure tested to
assure watertightness prior to backfilling.
8. All water mains to be pressure tested for leakage and sterilized in
accordance with directions from Carmel Water Department.
9. No traffic will be allowed on prepared subgrode prior to paving.
10. All street construction within the lines of dedicated right -of -way shall be
in accordance with the Specifications of Hamilton County Highway Deportment.
11. Property line corners of street intersections are rounded by an arc having
a 20' radius. Property lines drawn hereon ore carried to the P.I. of the
arc.
12. A temporary
graded shall
construction
seeding mixture In the areas where stripping of fills have been
be seeded for silt and erosion protection. After grading all
areas are to be seeded as follows:
A. Swale seeding Seed and fertilize within construction limits with 5# /acre
"Redtop" grass, 20# /acre "Rye Grass 20# /acre "Blue Gross 25# /acre
"Tall Fescue" gross, and 6600#/acre 12 -12 -12 fertilizer.
B. Cut /Fill Seeding Along Paved Areas: Seed and fertilize with 25# /acre "Tall
Fescue" grass, 20# /acre "Rye Grass 15# /acre "Blue Grass" and 600# /acre
12 -12 -12 fertilizer.
13. The location of houses (depicted by rectangles) show the pad elevation and /or
outside grade. The finished floor elevation is 8 inches higher, more or less
than the outside grade.
t
PLANS PREPARED BY:
W EI HE ENGINEERS, INC.
10505 N. COLLEGE AVE.
INDIANAPOLIS, IN 46280
TELEPHONE: (317) 846 -6611
FAX: (317) 843-0546
CONTACT PERSON: DAVE .BARNES
SITE LOCATION MAP
*PROJECT LOCATION
14. It shall be the responsibility of each contractor to verify all existing
utilities and conditions pertaining to his phase of the work. It shall also
be the contractors responsibility to contact the owners of the various
utilities before work is started. The contractor shall notify in writing the
owners and /or the engineers of any changes, errors, or omissions found on
these plans or in the field before work is started or resumed.
15. Contractor to record dimensions measured along sewer line from nearest
manhole to each sanitary sewer lateral.
16. Contractor to record dimension of each water stub from nearest fire hydrant
measured along the water main.
19. The above locations of laterals, along with any other construction changes
are to be Incorporated on the original construction drawings and record
drawings submitted to the City Engineer's Office as soon after completion of
construction as possible.
20. Contractor shall verify subsurface conditions prior to bidding.
21. "The engineer disclaims any role in the construction means and
methods associated with the project as set forth in these plans."
22. No sprinkler systems shall be ploced within the right of way without obtaining a
permit from the Hamilton County Highway Department. The Highway Department
reserve the right to deny a permit to install sprinkler systems within the right of
23. All electrical light posts must be set bock in the designated utility easement as
shown in the construction plans. Any lights which are installed within the dedicated
right of way shall be removed or relocated at the Developers expense.
24. All construction operations must be constructed as shown in the approved construction
drawings. Variances from the construction drawing must be approved by the
appropriate deportment before it is constructed in the field. All unauthorized
items which are not constructed as shown in the approved drawings may result in the
removal and reconstruction of the item(s).
25. No decorative signs, sprinkler systems, trees or other such amenities are permitted
in the right of way.
26. All drainage pipe and ditch outfalls to receiving streams shall be constructed in
accordance with drawings, subject however, to any modification required by the
County Drainage Board at the time installation is completed and to any
adjustments needed for field conditions that could not be anticipated on the
design drawings.
DESIGN SPEED 25
KPH
CYRREN T ZON/NO: 5-7
*SUBMITTAL UNDER OPEN SPACE
STANDARDS CARMEL /CLAY SUBDIVISION
CONTROL ORDINANCE.
way.
3
2
INDEX
RVISIONS
lJ
'21P'
011011g
w
uz
W
a.
M
N
1-a
SHEET NO.
v)
M
CO
ca
PROJECT NO.
1
z
(0
v7
w
0
v7
0
V)
0
a.
tal
U
r
0
0
Pr)
C?.
'Ga
c
1
a
Y
4 1 0398
STATE OF
r
A N
U SU R\i
ifff
Wog --0950
0
0
NJ
a
A o
w
(I)
0
U
.Q
Q