HomeMy WebLinkAbout03080001 Construction Plans for Ballantrae pg. 12Er-15"
18"&OVER
TOvIMY T. LUK
SHIRLEY vl. CAPPAS
Beginning Point
12 VALVE
TOP OF BANK
D. &U. E.
8
7104 SF
9
7911 SF
10' ASPHALT PATH
12" WATER LINE
7471 F TREE CONSERVATION
DRIVE ACCESS EASEMENT
(2295 SF)
6552 SF TOP of
RETAINING WALL
887.70
w.n...,ww 0.144.4.04
'LAKE AREA TO BE VER (CALL Y WALLED
•'(PER'DEVELOPER •SPECIFICATIONS)
N.P. AREA w. 5546 SF
N.P. ELEV 881.20
BOTTOM ELEV 876.00
100 YEAR FLOOD ELEV. 885.70
9338 SF
12" WATER LINE
9822 SF
9677 SF
4
9040 SF
86 725 SF
D. &U.E.
*EXISTING TREES IN
R/W TO BE REMOVED
FOR HCHD
WILLIAM M.
CAROLINE K. GODFREY
ADA RAMP
OSBORN LEGAL DRAIN
*EXISTING TREES IN
R/W TO BE REMOVED
FOR HCHD
KIM J. SANDRA L. REGAN
12" WATER LINE
CONNECT TO PONDS
WEST SUBDIVISION
WATER LINES
1. SCOPE OF WORK
A. THE WORK REQUIRED UNDER THIS SECTION INCLUDES ALL COLD WATER DISTRIBUTION
ONES, VALVES, METER pin, HYDRANTS, AND RELATED ITEMS INCLUDING EXCAVATING AND
BACKFILUNG NECESSARY TO COMPLETE THE WORK SHOWN ON THE DRAWINGS. THE END
OF WATER SERVICE LINES SHALL BE TIGHTLY PLUGGED OR CAPPED AT THE TERMINAL
POINTS PENDING THE CONNECTING TO ALL SUCH ONES OF THE BUILDING PIPING AS
SPECIFIED IN THE PLUMBING SPECIFICATIONS AND ARCHITECTURAL DRAWINGS.
2. MATERIALS
A. DUCTILE IRON PIPE: DUCTILE IRON PIPE SHALL MEET AWWA C -150 AND C -151
SPECIFICATIONS. PIPE SHALL BE CEMENT UNED PER AWWA C -104.
B. COPPER TUBING: SHALL BE SEAMLESS, ANNEALED COPPER TUBING COMPLYING WITH
FEDERAL SPECIFICATION WW -T799. FITTINGS SHALL BE WROUGHT COPPER OR CAST
BRONZE WITH SOLDER JOINTS. SOLDER SHALL BE OF A COMPOSITION RECOMMENDED BY
THE MANUFACTURER OF THE FITTINGS.
C. FIRE HYDRANTS: SHALL COMPLY WITH AWWA SPECIFICATION C -502 AND SHALL MEET
LOCAL STANDARDS AND REQUIREMENTS, PARTICULARLY AS TO NOZZLE DIAMETERS AND
THREADS, DIRECTION OF OPENING AND DIMENSIONS OF OPERATING AND CAP NUTS, FIRE
Sec HYDRANTS SHALL HAVE ONE PUMPER AND TWO HOSE NOZZLES. A VALVE OPENING NOT
Harrison LESS THAN 5 INCHES AND A 6 INCH INLET CONNECTION. THE LENGTH OF THE HYDRANT
BARREL SHALL BE DETERMINED BY THE SPECIFIED DEPTH OF COVER OVER THE PIPE.
A1. VALVES: All VALVES AND STOPS SHALL HAVE ENDS SUITED OR ADAPTERS SHALL BE
PROVIDED FOR THE PROPER INSTALLATION IN THE LINES IN WHICH THEY ARE LOCATED.
VALVES PROVIDED FOR THE PROPER INSTALLATION IN THE UNES IN WHICH THEY ARE
North line NE /4 Sec. 22- LOCATED, VALVES SHALL MEET LOCAL STANDARDS OR IN THE ABSENCE OF SUCH
N 90'00'00" E STANDARDS, THE FOLLOWING REQUIREMENTS.
2629.98' 1. VALVES IN CAST IRON PIPE SHALL BE IRON BODY, BRONZE MOUNTED, DISC GATE
VALVES CONFORMING TO AWWA SPECIFICATION C -500. THEY SHALL OPEN IN THE
SAME DIRECTION AS THOSE USED IN THE LOCAL WATERWORKS SYSTEM. VALVE STEMS
SHALL TERMINATE IN 2 INCH WRENCH NUTS. FURNISH TWO (2) KEYS.
2. VALVES IN COPPER PIPE SHALL BE STANDARD BRASS BODY, ROUND -WAY, GROUND
KEY STOPS, WITH T HEADS. FURNISH TWO (2) KEYS.
E. VALVE BOXES: SHALL MEET LOCAL STANDARDS OR IN THE ABSENCE OF SUCH, SHALL
COMPLY WITH THE FOLLOWING REQUIREMENTS:
1. FOR IRON BODY VALVES, BOXES SHALL BE APPROVED STANDARD BUFFALO -TYPE CAST.
IRON, ADJUSTABLE SHAFT BOXES, HAVING A MINIMUM SHAFT DIAMETER OF 5 -1/4
INCHES.
2. FOR BRASS BODY VALVES (STOPS) BOXES SHALL BE APPROVED STANDARD CAST IRON
EXTENSION SERVICE BOXES, HAVING A MINIMUM DIAMETER OF' 2 -1/2 INCHES AND
HAVING UD HELD IN PLACE BY A BRASS OR BRONZE BOLT. THE CASTINGS SHALL
BE COATED WITH TWO COATS OF COAL -TAR PITCH VARNISH. FURNISH TWO (2) KEYS
FOR BOLT IN LIDS,
F. JOINT RESTRIANT: MECHANICAL JOINT RESTRAINTS AS PROVIDED BY
EBAA IRON SALES, INC.
P.O. BOX 857
EASTLAND, TX 76448
800 -433 -1716
"MEGALUG" MECHANICAL RESTRAINT SYSTEM
INSTALL AS RECOMMENDED BY MANUFACTURER AND AS APPROVED BY CITY OR CARMEL UTIUTI
G. REACTION ANCHORS: JOINT HARNESSES SHALL BE STEEL STRAPS AND RODS ACROSS JOINTS
SECURELY ANCHORED ON PIPE OR OTHER ADEQUATE ANCHORAGE, TO RESIST HYDRAUUC THRU
AT MAXIMUM PRESSURE PIPE WILL BE SUBJECTED TO, 150 PSI MINIMUM.
1. COAL TAR COATING: KIPPERS BITUMASTIC NO. 50.
2. CLAMPS, STRAPS, AND WASHERS: STEEL, ASTM A506.
3. RODS: STEEL, ASTM A575.
4. ROD COUPUNGS: MALLEABLE IRON, ASTM A197.
5. BOLTS: STEEL, ASTM A307.
6. CAST IRON WASHERS: GRAY -IRON, ASTM Al26.
3. APPLICATION:
A. PERMITS AND CODES: THE INTENT OF THIS SECTION OF THE SPECIFICATIONS IS THAT
THE CONTRACTOR'S BID ON THE WORK COVERED HEREIN SHALL BE BASED UPON THE
DRAWINGS AND SPECIFICATIONS BUT THAT THE WORK SHALL COMPLY WITH ALL APPLICABLE'
CODES AND REGULATIONS. CONTRACTOR SHALL FURNISH ALL NECESSARY BONDS TO GET
PERMITS FOR CUTS AND CONNECTIONS.
B. EXISTING IMPROVEMENTS: MAINTAIN IN OPERATING CONDITION ALL ACTIVE UTILITIES AND
SEWERS AND OTHER PIPE SYSTEM THAT MAY BE ENCOUNTERED.
C. TRENCHING: LAY ALL PIPE IN OPEN TRENCHES, EXCEPT WHEN LOCAL AUTHORITY GIVES
WRITTEN PERMISSION FOR TUNNELING. PROVIDE SEPARATE TRENCH FOR THE WATER UNE
AT LEAST 10 FEET HORIZONTALLY FROM ANY SANITARY SEWER. IN LOCATIONS WHERE
SEPARATE TRENCHES FOR SEWER AND WATER ONES ARE IMPRACTICABLE, LAY THE WATER
PIPE ON A SOUD SHELF AT LEAST 18 INCHES ABOVE THE TOP OF THE SEWER.
D. WIDTH OF TRENCH: EXCAVATE TRENCHES 12 INCHES EACH SIDE OF THE PIPE FOR
PROPER INSTALLATION OF PIPE.
E, SHEETING AND BRACING: SHEET AND BRACE TRENCHES AS NECESSARY TO PROTECT
WORKMEN AND ADJACENT STRUCTURES. ALL TRENCHING SHALL COMPLY WITH THE
OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION STANDARDS.
F, WATER REMOVAL: KEEP TRENCHES FREE FROM WATER WHILE CONSTRUCTION THEREIN IS
IN PROGRESS, UNDER NO CIRCUMSTANCES LAY PIPE OR APPURTENANCES IN STANDING
WATER. CONDUCT THE DISCHARGE FROM TRENCH DEWATERING TO DRAINS, OR NATURAL
DRAINAGE CHANNELS.
G. GRADING TRENCH BOTTOMS: THE BOTTOM QUADRANT OF THE PIPE SHALL BE FULLY AND
UNIFORMLY SUPPORTED. THE FULL LOAD SHALL REST ON THE BARREL OF THE PIPE.
THE TRENCH MAY BE EXCAVATED TO A DEPTH OF 4 INCHES OR MORE BELOW FINAL
GRADE WITH NATURAL RIVER OR BANK SAND BACKFILL TO BRING IT BACK TO PIPE
LAYING GRADE. FOR A DEPTH OF AT LEAST 12 INCHES ABOVE THE TOP OF THE PIPE
BACKFILL WITH EARTH OR GRANULAR MATERIAL FREE FROM LARGE STONES, ROOTS OR
FROZEN CLOGS. TAMP THIS BACKFILL THOROUGHLY TAKING CARE NOT TO DISTURB THE
PIPE. BACKFILL UNDER WALKS, PARKING AREAS DRIVEWAYS AND STREETS WITH GRANULAR
MATERIAL ONLY AND TAMP THOROUGHLY, BY APPROVED METHODS. TRENCHES PARALLEL
TO AND WITHIN 10 FEET OF PAVED ROADWAYS SHALL ALSO BE CONSTRUCTED WITH
COMPACTED GRANULAR MATERIAL.
H. TESTS: BEFORE JOINTS ARE COVERED, FILL THE PIPING WITH WATER, OPENING HYDRANTS
OR OTHER OUTLETS TO EXPEL AIR. TEST THE PIPING FOR LEAKAGE AS REQUIRED BY THE
LOCAL UTILITY. INSPECT ALL JOINTS FOR LEAKAGE AND REMEDY ANY LEAKS. UPON
COMPLETION OF THE WATER ONES, FLUSH OUT THE SYSTEM UNTIL THE WATER RUNS
CLEAR. AS SOON AS THE SYSTEM HAS BEEN FLUSHED OUT, IT SHALL BE STERILIZED IN
ACCORDANCE WITH THE REQUIREMENTS OF THE LOCAL UTIUTY.
I. IF A HORIZONTAL DISTANCE OF 10 FEET CANNOT BE MAINTAINED BETWEEN THE WATER LINE
AND THE SANITARY SEWER UNE, THE SEWER MUST BE CONSTRUCTED OF WATER WORKS
GRADE DUCTILE IRON PIPE WITH MECHANICAL JOINTS WITHIN 10' OF EITHER SIDE THE
WATER LINE,
J. UTILITIES: IT SHALL BE THE RESPONSIBILITY OF EACH CONTRACTOR TO VERIFY ALL
EXISTING UTILITIES AND CONDITIONS PERTAINING TO HIS PHASE OF THE WORK. IT SHALL
ALSO BE THE CONTRACTOR'S RESPONSIBILITY TO CONTACT THE OWNERS OF THE VARIOUS
UTIUTIES BEFORE WORK IS STARTED. THE CONTRACTOR SHALL NOTIFY IN WRITING THE
OWNERS OR THE ENGINEER OF ANY CHANGES, ERRORS OR OMISSIONS FOUND ON THESE
PLANS OR IN THE FIELD BEFORE WORK IS STARTED OR RESUMED.
K. NEW WATER LINE CONSTRUCTION: CONTRACTOR TO RECORD DIMENSION OF EACH WATER
STUB AND VALVES FROM NEAREST FIRE HYDRANT MEASURED ALONG WATER MAIN. THE
LOCATIONS OF HYDRANTS AND WATER VALVES, ALONG WITH ANY OTHER CONSTRUCTION
CHANGES ARE TO BE INCORPORATED ON THE ORIGINAL CONSTRUCTION DRAWINGS AND
"RECORD DRAWING" PRINTS SHALL BE SUBMITTED TO THE LOCAL UTILITY AS SOON AFTER
CONSTRUCTION AS POSSIBLE.
1 VALVE REQ'D AT
CONNECTION TO
EXISTING WATER LINE
s LING OF POND
WEST
PRESSURE PIPE JOINT RESTRAINT TABLE
LENGTH OF PIPE TO BE RESTRAINED
IN EACH DIRECTION FROM CENTERLINE OF BEND
BASEDON 150 PSI TEST PRESSURE
DEGREE
OF BEND
90; TEES
PLUGS
22 -1/2'
RESTRAINED JOINTS SHALL BE MECHANICAL JOINT WITH RETAINER GLANDS,
US PIPE TR FLEX JOINT SYSTEM, US PIPE FIELD LOK GASKET SYSTEM,
OR EQUAL
NOTE:
THE ABOVE RESTRAINED JOINT LENGTHS ARE MINIMUM LENGTHS THE
DESIGN ENGINEER SHALL DETERMINE IF LONGER LENGTHS ARE REQUIRED.
EXISTING
WATER
MAW
TAPPING SLEEVE
GATE VALVE
FINISH GRADE
'POST -CAP
VALVE COVER
WATER SERVICE
TO BLDG. SITE
WATER MAIN CONNECTION
ES.
ST
PUMPER CONNECTION
IF REQUIRED BY
LOCAL FIRE DEPT.
FACING ROAD OR NEAREST
FIRE TRUCK ACCESS
UNDISTURBED GROUND
4'•. 1
v vv v v
I�i 77o
ADJUSTABLE
CAST IRON
VALVE BOX
EAST JORDON
NO. 6860
LEAVE HYDRANT DRAIN OPEN
LEGEND
EXIST. FIRE HYDRANT
EXIST. WATER METER
EXIST. WATER VALVE
EXIST. YARD SPIGOT
EXIST. MONITOR WELL
EXIST. GAS METER
EXIST. GAS VALVE
EXIST. STORM INLET
EXIST. ELECTRIC METER
EXIST. POWER POLE
EXIST. POWER POLE W /LIGHT
EXIST. POWER POLE W /TRANSFORMER
EXIST. LIGHT POLE
EXIST. GUY ANCHOR
EXIST. TELEPHONE PEDESTAL
EXIST. MANHOLE
EXIST. SANITARY SEWER LINE
EXIST. STORM SEWER LINE
RIGHT -OF -WAY LINE
SWALE
PROPOSED SANITARY SEWER LINE
PROPOSED STORM SEWER LINE
PROPOSED MANHOLE
PIPE SIZE
BEDDING BELOW
PIPE BARREL
vvr" rr�ynr
v v
v07P9- 7 9 7 77
'v P v v v'v v'v P'v v G
svv:97
_Iii ii► I �f�11I.
NATURAL RIVER OR
7 t5;
PROPOSED FIRE HYDRANT
PROPOSED FIRE HYDRANT W /VALVE
GRAVEL OR CRUSHED ROCK
DRAIN POCKET
THOROUGHLY COMPACTED
On
1/2 0.D.
vvvv
vvvy
0,11/4 0.014 vvv
v v)
vv
77 7v 1 7C7vv77v
I vvvvvvvvvvvvvvvvvvvvj
=1 v v v v v v v v v v v v v v v v v v
V V V v v V v v v v v v V V v' 7 v v
1 1 vv vv v c 1. 25 0 DD.+ 12' v v v v
c„�vvvv vvvvv v
V v 7 7vvvvvvvv
vvvvvvvvvvvvy�
vvvvvvvvvvvy
vvvvvvvvvvv
vvvvvvvvvvcv
vvvvvvvvvvV c
vvvvvvvvvv v
vvvvvvvvvvvy
vvvvvvvvvvvy
vvvvvvvvvvvy
vvvvvvvvvvvvv
v•vvv Op,,•v V
4.1 JV vvvv v
NATURAL RIVER OR .I 1 v
BANK UND ASA5TM CF36. v
TYPICAL
VALVE BOX INSTALLATION
COLLAR PER LOCAL
ARE DEPT. REQUIREMENTS
2 HOSE OUTLETS
-1' -6•
HOSE AND PUMPER CONNECTIONS SWILL HAVE THE
SAME TYPE AND NUMBER OF THREADS PER INCH TO
HATCH THOSE OF THE LOCAL FIRE DEPARTMENT
FIRE HYDRANT DETAIL
VALVE BOX COVER
FLUSH WITH GRADE
MECHANICAL
RESTRAINT
SYSTEM
Call L4onday thro$gh tirZOISi.1 °J 1-8. 382 :I` -5200
Within In Tr Oui.ld. Indiana
PER INDIANA STATE LAW IS -69 -1991, IT IS
AGAINST THE LAW TO EXCAVATE WITHOUT
NOTIFYING THE UNDERGROUND LOCATION SERVICE
TWO (2) WORKING DAYS BEFORE COMMENCING WORK.
PROJECT NO.
W02 --0950
vn
10 9 a
3
u
0
v