Loading...
HomeMy WebLinkAbout03090027 Development for Weston Park pg. JUTILITY BLOCKING FOR PLUGS AND BENDS BLOCKING FOR PLUGS AND BENDS PIP': SIZE OUTSIDE FACE AREA (SQ. FT.) CTORS ROW, SUITE E PHONE: 317-244-196E3 AS, INDIANA 46241 FAX: 317-244-1969 SIZE OF OUTSIDE FACE AREA (SQ. FT.) PLUG 90? I II 1/2:11 1 /4? 1 BRANCH SUITE 30 S. MERIDIAN DEVELOPMENT 16 25 14 NI 4 20" OR 16" mo 12 16" j I I I l Is co R Np i f PE880303 t STATE OF s �F G o, S S /ONA\ O� I "II I I I W I DATE: 1 1/24/03 9 5 3 12" 7 FE DE1 6 106th STREET MI CARMEL, I] 5 3 2 12 7 DWN BY: KR C CHKD. BY: RRH SCALE: NONE DATE: 1 1 /24/03 7 PROJECT NUMBER 03 -188 1 DESIGN PHASE DEVELOPMENT j 12" 7 PLAN NUMBER C7.2 SHEET OF UTILITY BLOCKING FOR PLUGS AND BENDS BLOCKING FOR PLUGS AND BENDS PIP': SIZE OUTSIDE FACE AREA (SQ. FT.) SIZE OF SIZE OF OUTSIDE FACE AREA (SQ. FT.) PLUG 90? 45? 22 1/2:11 1 /4? RUN BRANCH 20" 16 25 14 7 4 20" OR 16" 16" 12 16" 12 16 9 5 3 12" 7 10" 6 9 5 3 2 12 7 8" 5 IC" 4 7 4 2 1 12„ OR LESS 12" 7 8 3 5 3 2 1 18 4 6 2 3 2 1 1 6" 4" 2 2 4" 2 3 2 1 1 UTILITY MINIMUM COVER REQUIRED STORM SEWER 2.0 FT. (PAVEMENT AREAS) 1.5 FT. (LAWN AREAS) SANITARY SEWER 4.0 FT. WATER LINE 4.0 FT. GAS LINE 3.0 FT. TELEPHONE LINE 2.5 FT. ELECTRIC LINE 2.5 FT. CASING SPACERS RUNNER ULTRA H MOLECULAR WEIGHT POLYMER WITH HIGH RESISTANCE TO ABRASION AND SLIDE WEAR I SLIDE IS A CHEMICAL MODIFIED, FILLED, ULTRA HIGH MOLECULAR WEIGHT POLYMER. w z cc RECEIVE OR BORE PIT 12' MIN. ALL JOINTS IN CASING PIPE MUST E RESTRAINED PAVEMENT TRADE OR FINAL GROUND SURFACE N NON— PAVEMENT AREAS (ALLOW FOR MINIMUM 6" OF TOPSOIL) BACKFILL MATERIAL SHALL CONSIST OF APPROVED TRENCH SOIL PLACED IN MAXIMUM B" THICK, LOOSE LIFTS AND COMPACTED TO A MINIMUM OF 95% OF ITS MAXIMUM DRY DENSITY AND WITHIN ±3% OF ITS OPTIMUM MOISTURE CONTENT. STAINLESS STEEL RIBBED FLANGE LINER PVC .090 THICK WITH 85 -90 DUROMETER STEEL CASING SECTIONS SHALL BE CONNECTED BY WELDING. WELD SHALL CONFORM TO AWWA C206. PIPE BEDDING MATERIAL SHALL CONSIST OF SAND PLACED IN MAXIMUM 3" THICK LOOSE LIFTS D COMPACTED TO A POINT OF NON MOVEMENT BENEATH THE COMPACTING EQUIPMENT. TOP HALF BOTTOM HALF DISTANCE OF BORE PIPE CASING SPACER 3 SPACERS REQUIRED PER LENGTH OF PIPE PROTECTION AT ENDS ")F CASING CASING SHALL HAVE BOTH ENDS BLOCKED UP IN SUCH A WAY AS TOPREVENT THE ENTRANCE OF FOREIGN MATERIAL, BUT ALLOWING LEAKAGE TO PASS TYPICAL BORING CASTING PIPE NOT TO SCALE 2' -0" O.D. MIN. GAS SERVICE LINE ABBREVIATIONS D INSIDE DIAMETER O.D. OUTSIDE DIAMETER MIN. MINIMUM COVER REQUIREMENTS SPECIFY 0.0 OF CARRIER PIPE AND I.D. OF CASING PIPE AS MEASURED FROM TOP OF PIPE TO FINAL GROUND SURFACE RECEIVE OR BORE PIT w z WATER SERVICE LINE NOT TO SCALE PAVEMENT SUBGRADE OR FINAL GROUND SURFACE IN NON— PAVEMENT AREAS (ALLOW FOR MINIMUM 6" OF TOPSOIL) BACKFILL MATERIAL SHALL CONSIST OF APPROVED TRENCH SPOIL PLACED IN MAXIMUM 8" THICK, LOOSE LIFTS AND COMPACTED TO A MINIMUM OF 95% OF ITS MAXIMUM DRY DENSITY AND WITHIN ±3% OF ITS OPTIMUM MOISTURE CONTENT. WATER SERVICE LINE PIPE BEDDING MATERIAL SHALL CONSIST OF AASHTO NO. 57 STONE PLACED IN MAXIMUM 6" THICK LOOSE LIFTS AND COMPACTED TO AT LEAST 75% OF ITS RELATIVE DENSITY BELOW THE PIPE MID POINT. THE BEDDING MATERIAL PLACED ABOVE THE PIPE MID —POINT SHALL CONSIST OF AASHTO NO. 57 STONE (PLACED AND COMPACTED AS PREVIOUSLY DESCRIBED), OR SAND WHICH IS PLACED IN MAXIMUM 6" THICK LOOSE LIFTS AND COMPACTED TO A POINT OF NON— MOVEMENT BENEATH THE COMPACTING EQUIPMENT. 4" DIA. TELEPHONE DUCT C, PROVIDE A MINIMUM OF 2 CONDUITS FOR BUILDING SERVICE 5" DIA. ELECTRICAL CONDUIT, MINIMUM SCHEDULE 80 PVC PIPE NOTES; 1. ALL MATERIALS EXCAVATED FROM THE UTILITY TRENCH SHALL BE STOCKPILED A MINIMUM SUFFICIENT DISTANCE FROM ALL TRENCHES TO PREVENT SLIDES OR CAVE —INS. 2. ALL BACKFILL MATERIALS SHALL BE APPROVED BY THE OWNER OR HIS REPRESENTATIVE BEFORE BEING PLACED. 3. THE AASHTO #57 STONE SHALL SATISFY THE REQUIREMENTS OF ADOT CONSTRUCTION AND MATERIALS SPECIFICATIONS. 4. THE MAXIMUM DRY DENSITY AND OPTIMUM MOISTURE CONTENT FOR THE BACKFILL MATERIALS SHALL BE DETERMINED BY ASTM D1557, AND THE RELATIVE DENSITY OF THE AASHTO #57 STONE SHALL BE DETERMINED BY ASTM 04253 AND ASTM D4254. 5. THE CONTRACTOR SHALL CONSTRUCT THE UTILITY TRENCHES AND PROVIDE ADEQUATE SHORING (WHERE NECESSARY) IN CONFORMANCE WITH THE LATEST REQUIREMENTS FOR CONSTRUCTION STANDARD FOR EXCAVATIONS (29 CFR PART 1926.650 —.652 SUBPART P) PROMULGATED BY OSHA. 6. THE CONTRACTOR SHALL VERIFY THAT THE MINIMUM SPECIFIED PIPE COVER IS PROVIDED BETWEEN THE FINAL GROUND SURFACE AND TOP OF PIPE BEFORE LAYING PIPE. PROVIDE A MINIMUM OF 2 FT. OF COVER ABOVE PIPES DURING CONSTRUCTION. 7. THE TELEPHONE AND ELECTRIC CONDUIT WILL NOT SHARE THE SAME UTILITY TRENCH WHERE THEY ARE SEPARATED AT THE MANHOLE /VAULT LOCATIONS. 5" DIA. ELECTRICAL CONDUI MINIMUM SCHEDULE 80 PVC PIPE ELECTRIC TELEPHONE SERVICE LINE NOT TO SCALE UNDISTURBED EARTH 2,000 LB. MIN. CONCRETE STRAP IRON ANCHORS 2" WIDE x 1/2" THICK BEDDING FOR TELEPHONE CONDUIT SHALL CONSIST OF SAND PLACED IN MAXIMUM 6" THICK LOOSE LIFTS AND COMPACTED TO A POINT OF NON— MOVEMENT BENEATH THE COMPACTING EQUIPMENT ENCASE ELECTRICAL CONDUIT IN CONCRETE THAT SATISFIES THE REQUIREMENTS OF THE CITY OF HUNTSVILLE. "r. PLAN UNDISTURBED EARTH 5" DIA. WASHER, 1" THICK 3/4" x 18" ANCHOR BOLTS (4 REQ'D) DOWNWARD BEND 3 —PIECE ADJUSTABLE VALVE BOX SUPPORT VALVE BOX WITH BRICK OR BLOCK ON UNDISTURBED EARTH VALVE FLANGED TO FITTINGS GATE VALVE PER AWWA C500 TO OPEN COUNTER CLOCKWISE VALVE FLANGED TO FITTINGS NOT LESS THAN 0.6 x LAYING LENGTH 2,000 LB. MIN. CONCRETE OUTSIDE FACE AREA NOT LESS THAN VALUES GIVEN IN TABLE FOR 22 1/7 AND 11 1/4* BENDS SET TOP FLUSH WITH FINISHED GRADE TO BE MARKED "WATER GATE VALVE PER AWWA C500 TO OPEN COUNTER CLOCKWISE 2,000 LB. MIN. CONCRETE STANDARD HYDRANT SETTING: INSTALL HYDRANT 3' FROM RIGHT —OF —WAY LINE OR AS APPROVED BY WATER COMPANY. EARTH UNDISTURBED EARTH OUTSIDE FACE AREA NOT LESS THAN VALUES GIVEN IN TABLE. SECTION "C -C" WATER MAIN CONCRETE BLOCKING NOT TO SCALE 1' -6" MIN. TO 2' -0" MAX. HYDRANT DETAIL NOT TO SCALE NOTE: SUPPORT VALVE BOX WITH BRICK OR BLOCK ON UNDISTURBED EARTH A r GATE VALVE AND BOX NOT TO SCALE OUTSIDE FACE AREA NOT LESS THAN VALUES GIVEN IN TABLE FOR 90? AND 45? BENDS PLAN DI ANCHORING COUPLING CONCRETE THRUST BLOCK ON UNDISTURBED EARTH SET TOP FLUSH WITH FINISHED GRADE. TO BE MARKED "WATER" 3 —PIECE ADJUSTABLE VALVE BOX SLEEVE WATER MAIN CONCRETE THRUST BLOCK ON UNDISTURBED EARTH NOT LESS THAN 0.75 x LAYING LENGTH 2,000 LB. MIN. CONCRETE UNDISTURBED EARTH OUTSIDE FACE AREA NOT LESS THAN VALUES GIVEN IN TABLE FOR PLUGS. SECTION "D -D" PUMPER CONNECTION TO FACE TOWARD PAVEMENT FINISHED GRADE 2,000 LB. MIN. CONCRETE BREAK AWAY HYDRANT THREADS TO MATCH LOCAL FIRE DEPARTMENT EQUIPMENT 6" NOMINAL BARREL MIN. 1 CU YD. LOOSE STONE OR GRAVEL FOR DRAINAGE. (6" ABOVE PORTS) DO NOT USE CRUSHED LIMESTONE. O.D. 1' -0" Min. (Typ.) CONCRETE COLLAR CONCRETE THRUST BLOCK NOT TO COVER JOINTS OR DRIP HOLE REQUIRED ON 10" AND LARGER MAINS. OUTSIDE FACE AREA NOT LESS THAN VALUES GIVEN IN TABLE FOR 90? NOTES; 1. WATER MAIN SHALL NOT BE LOCATED IN THE SAME TRENCH AS SANITARY SEWERS. 2. SEPARATION OF 3 FEET MTh ANY UTILITY REQUIRED. UNDISTURBED EARTH 2,000 LB. MIN. CONCRETE OUTSIDE FACE AREA NOT LESS THAN VALUES GIVEN IN TABLE FOR TEES AND WYES PLAN GRADE MINIMUM ANGLE OF INTERSECTION 45? �I�Ir f PIPE OR BEND AS REQUIRED 10' NOTE: BENDS FITTINGS AS REQUIRED. SEE PLAN SHEETS FOR DETAILS. CONNECTION TO EXISTING WATER MAIN NOT TO SCALE 10' MIN. SANITARY OR STORM SEWER WAT ER MAIN LAYING PARALLEL TO SEWER WATER MAIN SEWER z NEW MAIN TAPPING SLEEVE VALVE BOX 3' 10' ANOTHER UTILITY FACILITY (TELEPHONE, GAS, ELECTRIC, CABLEVISION, ETC.) WATER MAIN. WATER MAIN TRENCHED IN PLACE TYPICAL DEPTH OF WATER MAIN 1/2" TO 8" PIPE SHOULD HAVE 4 6" OF COVER, 10" AND LARGER PIPE SHOULD HAVE 4' OF COVER. CLASS 150 MECH. JOINT FLEXIBLE COUPLING DUCTILE IRON PIPE OR ADAPTOR CONC. COLLAR WATER MAIN CROSSING SEWER SEWER /WATER LINE SEPARATION NOT TO SCALE EXISTING WATER MAIN FLEXIBLE COUPLING OR ADAPTOR AS SPECIFIED