HomeMy WebLinkAbout03090002 Cherry Creek Estates Subdivision Section 2 Large Plan pg. DEARTHWORK:
1. EXCAVATION
FORM \EARTHWRK
1848
870
<000
100
874.1
M.S.E.
LEGEND
EXISTING CONTOUR
EXISTING SANITARY SEWER
EXISTING STORM SEWER
PROPOSED GRADE
PROPOSED CONTOUR
PROPOSED SANITARY SEWER
PROPOSED STORM SEWER
PROPOSED SWALE
PROPOSED 5' SIDEWALK (BY HOME BUILDER)
(DEVELOPER SHALL INSTALL SIDEWALKS ALONG ALL COMMON AREAS)
LOT NUMBER
PAD ELEVATION
PAD SIZE 60'Wx40'D
(UNLESS OTHERWISE NOTED)
MINIMUM SUMP ELEVATION= 758.50
MFPG MINIMUM FLOOD PROTECTION GRADE 762.10
(NO BUILDING OPENING WINDOWS, WINDOW WELLS, DOORS, ETC)
(WILL BE ALLOWED BELOW THIS ELEVATION)
M.E. MATCH EXISTING
NP N-ROLL CURB
sD SPECIAL DRAINAGE
(FROM REAR OF LOT TO FRONT AROUND HOUSE.)
PROPOSED 6" UNDERDRAINS
EMERGENCY FLOOD ROUTING
WA 766.52 TYPICAL 100 YEAR ELEVATION
DENOTES 6" SUBSURFACE DRAIN SURVEYOR'S OFFICE STANDARDS)
S &A TBM #1:
PWP #056462 ON WEST SIDE CHERRY TREE 1400 CHERRY
TREE RD APPROX. 1'± ABOVE EXISTING GROUND EAST SIDE OF
POLE MINI RAILROAD SPIKE
ELEV.= 778.56
S &A #2:
NORTH BONNET NUT ON FIRE HYRDRANT LOCATED ON WEST
SIDE STUB OF KICKAPOO LN. JUST NORTH OF KICKAPOO LN.
AND ARAPCHO CT. INTERSECTION IN DELAWARE TRACE
SUBDIVISION
DENOTES 4" SUBSURFACE DRAIN TO LOT (PER HAMILTON COUNTY
ELEV.= 762.05
FLOODWAY ZONE AE AS SCALED FROM
THE FLOOD INSURANCE RATE MAP (FIRM) FOR
HAMILTON COUNTY, INDIANA, COMMUNITY NAME, CARMEL,
COMMUNITY NUMBER, 180081, PANEL NUMBER, 0227F,
MAP NUMBER 18057CO227F, DATED FEBRUARY 19, 2003.
(FFF)
FLOODWAY FRINGE ZONE AE AS SCALED FROM
THE FLOOD INSURANCE RATE MAP (FIRM) FOR
HAMILTON COUNTY, INDIANA, COMMUNITY NAME, CARMEL,
COMMUNITY NUMBER, 180081, PANEL NUMBER, 0227F,
MAP NUMBER 1805700227F, DATED FEBRUARY 19, 2003.
FLOODWAY PER HEC -RAS CALCULATIONS BY
(FWS) STOEPPELWERTH ASSOCIATES, INC. DATED
FEBRUARY 3, 2003.
S &A #3:
MANHOLE TC INTERSECTION OF STONE PINE TRAIL AND
THORN WOOD DR. 5806 STONE PINE TR. IN STONE
HAVERSTICK SUBDIVISION
A. Excavated material that is suitable may be used for fills. All unsuitable material and all surplus
excavated material not required shall be removed from the site.
2. REMOVAL OF TREES
A. All trees and stumps shall be removed from areas to
structure area. Trees and stumps shall not be buried
be occupied by a road surface or
on site.
ELEV.= 764.14
S &A #4:
TOP STEP ON STOOP SW COR. OF ENTRY TO WELL #17 SW
COR. OF STOOP ON PROPERTY EXCEPTION
ELEV.= 775.59
B. Provide and place any additional fill material from offsite as may be necessary to produce the grades
required on plans. Fill obtained from offsite shall be of quality as specified for fills herein and the
source approved by the Developer. It will be the responsibility of the Contractor for any costs for
fill needed.
3. PROTECTION OF TREES
A. The Contractor shall, at the direction of the Developer, endeavor to save and protect trees of value
and worth which do not impair construction of improvements as designed.
B. In the event cut or fill exceeds 0.5 foot over the root area, the Developer shall be consulted with
respect to protective measure to be taken, if any, to preserve such trees.
4. REMOVAL OF TOPSOIL
A. All topsoil shall be removed from all areas beneath future pavements or building. Topsoil removal shall
be to a minimum depth of 6 inches or to the depth indicated in the geotechmical report provided by the
Developer to be excavated or filled. Topsoil should be stored at a location where it will not interfere
with construction operations. The topsoil shall be free of debris and stones.
5. UTILITIES
A. Rules and regulation governing the respective utility shall be observed in executing all work under
this section.
B. It shall be the responsibility of the Contractor to determine the location of existing underground
utilities 2 working days prior to commencing work. For utility locations to be marked call Toll Free
1- 800 382 -5544 within Indiana or 1- 800 428 -5200 outside Indiana.
6. SITE GRADING
A. Do all cutting, filling, compacting of fills and rough grading required to bring entire project area
to subgrade as shown on the drawing.
B. The tolerance for paved areas shall not exceed 0.10 feet above established subgrade. All other areas
shall not exceed 0.10 feet plus or minus the established grade. Provide roundings at top and bottom
of banks and other breaks in grade.
C. The Engineer shall be notified when the Contractor has reached the tolerance as stated above, so
that field measurements and spot elevations can be verified by the Engineer. The Contractor shall
not remove his equipment from the site until the Engineer has verified that the job meets the above
tolerance.
C.A. #9
VAR. D.E.
1762.01
132.6
764.571
30 L.F.
30 F.
0.21%
15" R. .P.
86
767.1
M.S.E.
130.00'
MFPG
87
767.1 MFPG
M.S.E.
10' D. &U.S.E. 1
LA #3
N .P.= 55.50
2 YEARJLEV.= 759.88
10 `R ELEV.759.97
'T06 YEAR ELEV.= 760.10
BOTTOM ELEV. 747.50 MIN.
130.00'
85
764.8
M.S.E.
130.00'
767.11
1765.69
90.00:`
1766.861
7 +50 8 +00
1765.441
62.85'
761.91
1766.611
92.10'
15 7 1:37.E.
1764.41
1765.19
1766.421
83 25' B.L.
767.5
M.S.E.
90 :00'::
76 6.35
1764.941
rrarn
0.42% mime
T.P.E.
20' D. &U.E.
111.68'
1764.691
84
767.0
M.S.E.
o 0
20' D.E.
L.P.
9 +94.74
1764.52
8' SDR 35 PVC
20' D.U. &S.S.E.
F.
0%
R
6' PEDESTRIAN
ASPHALT PATH
V 5 a E;IL i 1Y EASEM
-G+TY OF CAfltvFEL
OF HAMILTON COUNTY
INST. #9502726
DELAWARE TRACE
SECTION.. 3
INST. #9909930367
1.34%
6' PEDESTRIAN
ASPHALT PATH
BFE 761`
ES
ij
15'.
J
0
0
0
M
D.E.
5+50
90.00'
109
768.0
M.S.E.
92.00'
'64.41
El l> 15' D.E.
92.00'
114
67.5
M.S.E.
1760.71
90.00'
20' D. &U.E.
1765.81
90.00' 21" R.C.P.
0
0
o'
r.'
15' D.E. 1762.71
(763.1
20' D. &U.E.
341 L.F.
20' D.U.&
82
767.5
M.S.E.
o 0 0 o 0 0
64.01 SWALE 2.78 SLOPE
1767.21
763.0
1762.6
1760.61
1764.41
110
767.7
M.S.E.
0
0
20
69.44'
762.0
92.00'
1762.01
CHERRY CREEK ESTATES
CT1ON 1B
tFwss
C am Ca
0
B.L.
STORM SEWER NOTE
THE STORM SEWER SYSTEM SHALL BE CONSTRUCTED PER
DESIGN SPECIFIED AND AS APPROVED BY THE CITY OF
CARMEL ON THE FINAL APPROVED CONSTRUCTION PLANS.
DEVIATIONS FROM THE APPROVED DESIGN SHALL ONLY BE
PERMITTED DUE TO SPECIAL CIRCUMSTANCES OR DIFFICULTY
DURING CONSTRUCTION AND WILL REQUIRE PRIOR FIELD
APPROVAL FROM A DESIGNATED REPRESENTATIVE OF THE
CITY OF CARMEL IN ADDITION TO SUPPLEMENTAL APPROVAL
BY THE DESIGN ENGINEER. AN EXPLANATION OF ANY SUCH
DEVIATION SHALL BE INCLUDED AS A REQUIREMENT ON
AS- BUILT /RECORD DRAWINGS SUBMITTED FOR RELEASE OF
PERFORMANCE GUARANTEES. APPROVED DESIGN SLOPES
IDENTIFIED AS GENERATING VELOCITIES OF 2.5 FPS OR LESS
(AT FULL FLOW CAPACITY) SHALL REQUIRE AS -BUILT
CERTIFICATION AT THE TIME OF CONSTRUCTION. THE
CONTRACTOR IS INSTRUCTED TO AS -BUILT EACH SECTION OF
STORM PIPE AS IT IS BEING INSTALLED TO ENSURE
COMPUANCE WITH THE DESIGN PLANS. AND AS APPROVED BY
THE CITY OF CARMEL
778.1
0
774.1
30 L.F.
1.o0%
12" R.C.P.
00
00
PAD DETAIL
H 40' H
COMPACTED FILL
7
EXISTING GRADE
TOE OF SLOPE
PROPOSED GRADE
SECTION "A
N.T.S.
0
LAKES WILL BE LINED WITH
A MINIMUM OF 18" OF CLAY
LINER.
M PX 0%
MAN
4" GARAGE SLAB
12" 1 BLOCK
4" SUMP
DRAIN
TYPICAL FOUNDATION
TOP OF WALL
18"
SUMP PIT
PAD GRADE
4" SLAB
WATER TABLE
"HOLEY MOLEY"
SAYS:
1 800 -382 -5544
CALL TOLL FREE
1 800 -428 -5200
FOR CALLS OUTSIDE OF INDIANA
761.5
CAUTION
5
SCALE: 1"= 50'
1 I
760.20 J
20' "I
E1V ERGENCY SPILLWAY
SECTION
N.T.S.
761.5
LOCATION OF ALL EXISTING UNDERGROUND
UTILITIES SHOWN ON THIS PLAN ARE BASED
UPON ABOVE GROUND EVIDENCE. (including,
but not limited to, manholes, inlets, valves,
marks made upon the ground by others.) AND
ARE SPECULATIVE IN NATURE. THERE MAY ALSO
BE OTHER EXISITING UNDERGROUND UTILIITIES
FOR WHICH THERE IS NO ABOVE GROUND
EVIDENCE OR FOR WHICH NO ABOVE GROUND
EVIDENCE WAS OBSERVED. THE EXACT LOCATIONS
OF SAID EXISTING UNDERGROUND UTILITIES
SHOULD BE VERIFIED BY THE CONTRACTOR
PRIOR TO ANY AND ALL CONSTRUCTION.
Z
J
W
J
m Q7
6
U
3 o
(7,
M
0)
O
J u
II
m
v7
z
0
w
ct
L.
I-
0
N)
O
H.< N
00
rr)
0
N
N
00
N)
z
0
z
w
L
ES
z
LJ
U
SHEET NO.
C201
JOB N0.4340552